Standardisation: History, Science and Politics

Similar documents
REVIEW Global standardisation of HbA 1c

Defining HbA1c: the indispensable decision to approach measurement standardization

Clinical Chemistry 54: (2008)

HbA1c and Diabetes. Steven Weier Senior Lecturer School of Biomedical Sciences Faculty of Health QUT. CRICOS No J

assay Introduction Conclusions: The D-100 TM system proved to be a robust and reliable method for HbA 1c

State of the Art of HbA1c Measurement

Hemoglobin A1c: Comparison of Pointe Scientific s 2-Part Direct Hemoglobin A1c with the Bio-Rad Variant II and the Tosoh G8

Maintaining Quality in Laboratory Medicine. Glycated Haemoglobin Scheme Guide

HbA1c: A Review of Analytical and Clinical Aspects

Implementation of HbA1c as a Diagnostic Test in New Zealand

ADAG Study Group Data Links A1C Levels with Empirically Measured Blood Glucose Values - New Treatment Guidelines Will Now be Needed

Evaluation of haemoglobin A1c measurement by an enzymatic method using an automated analyser that has an on-board haemolysis system

COMPARISON OF CATION EXCHAGE HPLC AND IMMUNOTURBIDIMETRIC METHOD FOR DETERMINATION OF HbA1c

Tosoh Automated Glycohemoglobin Analyzer HLC-723GX

In normal human erythrocytes,

HbA1c enzymatic assay evaluation at AN academic

Towards a Certified Reference Material for HbA 2

HbA 1c Measurement by IDMS Current Situation and Future Development

Sandra Božičević dipl. ing. med. biochem, Marijana Vučić Lovrenčić, PhD Vuk Vrhovac University Clinic, Zagreb, Croatia

BIOLOGICAL VARIABILITY: THE CIRME CONTRIBUTION. F. Braga Centre for Metrological Traceability in Laboratory Medicine (CIRME)

Monitoring Diabetes Mellitus with HBA 1 C: The Abakaliki, Nigeria Experience

Biomedical Research 2017; 28 (4):

Effects of hemoglobin C, D, E and S traits on measurements of hemoglobin A1c by twelve methods

Evidence Based HbA1c Accuracy. Sabrina Koetsier Medical Scientist RCPAQAP Chemical Pathology

New Guidelines for the Diagnosis of Diabetes Mellitus

DIRECT ENZYMATIC HbA1c ASSAY

Analysis of Hemoglobin A1c from Dried Blood Spot Samples with the Tina-quant II Immunoturbidimetric Method

Clinica Chimica Acta

Calibration of ion-exchange HPLC measurements of glycohemoglobin: effect on interassay precision

Direct HbA1c testing capabilities on the RX modena

Improving the Accuracy of Hemoglobin A 1c. : Your Help Is Needed

Glycated haemoglobin; past, present, and future are we ready for the change Iftikhar Ahmad Asim Syed Whitfield Clinic, Cork Road, Waterford, Ireland.

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser

IFCC Scientific Division Report to Council, Istanbul, June Ian S.Young Queen s University Belfast Chair, IFCC-SD

Electrolyte Analyzer with Ion-Selective Electrode and Blood Gas analyzer

Selecting a Hemoglobin A1C Point of Care Instrument. Objectives. Disclosure / Conflict of Interest 3/11/2015

Clinical outcomes of HbA1c standardisation

Long-Term Evaluation of Electrospray Ionization Mass Spectrometric Analysis of Glycated Hemoglobin

College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey

Certification of the amount-of-substance fraction of HbA1c versus the sum of all Hb isoforms forming the glycated or non-glycated

Correlation between eag Values Calculated from HbA1C Values and Fasting Plasma Glucose Levels for Diagnosis and Prognosis of Diabetes

Accuracy of Filter Paper Method for Measuring Glycated Hemoglobin

GUIDE TO THE EVALUATION OF COMMUTABILITY OF CONTROL MATERIALS

Bias in clinical chemistry. Elvar Theodorsson EFLM and Linköping University

MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels

The influence of sample freezing at 80 C for 2 12 weeks on glycated haemoglobin (HbA 1c

CCQM-K6: Key Comparison on the Determination of Cholesterol In Serum* Final Report December 2001

HbA 1c will remain the preferred marker for assessing glycaemic control

EXTERNAL QUALITY ASSESSMENT FOR HAEMOGLOBIN A 2

Measurand characteristics & reference materials for hcg

HbA1c: what the GP needs to know

Use of Fructosyl Peptide Oxidase for HbA1c Assay

: EQA in Germany, Belgium and the Netherlands using fresh whole blood samples with target values assigned with the IFCC reference system

Software Version 1.0. User s Manual

A COMPARATIVE EVALUATION OF HBA1C MEASUREMENT IN DIFFERENT ANTICOAGULANT VIALS AND ITS STABILITY ON STORAGE

Can glycated albumin assist in management of diabetes mellitus? Jasna Lenicek Krleza, PhD. Children s Hospital Zagreb, Croatia

Should HbA1C measured by POC instruments be used for diagnosis of diabetes? Sverre Sandberg, Norwegian Quality Improvement of Primary Care

Auto HbA1C ANALYZER HbA1LC HPLC 3660

IFCC in its 60 th YEAR Achievements and Future Opportunities. Mathias M. Müller

Journal of Diabetes and Metabolic Disorders; 2011; Vol 10, pp 1-6. Keywords: Glycated hemoglobin, Paper filter, Diabetes, Dried blood spot.

Moving to an A1C-Based Screening & Diagnosis of Diabetes. By Prof.M.Assy Diabetes&Endocrinology unit

Standardization efforts for Alzheimer CSF biomarkers, and Plasma neurofilament light (NFL) as a biomarker for AD

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

External Quality Assessment of HbA 1c for Point of Care Testing

Postanalytical External Quality Assessment of Blood Glucose and Hemoglobin A 1c : An International Survey

Dubrovnik 2014 Sverre Sandberg, Norwegian Quality Improvement of Primary Care Laboratories Noklus, Bergen, Norway

The Integrated Cardiovascular Clinical Network CHSA

Sample Pages. Glycated Haemoglobin (HbA1c) Testing Market,

Understanding Diabetes Jesse Omamogho

2015 SATELLITE MEETING

Research Article Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

Haemoglobin A 1c in the diagnosis and monitoring of diabetes mellitus

Quick Reference Guide. on Turbodyne SC

Rat Hemoglobin A1c (HbA1c) Kit Instructions

Monitoring of glycemic status, as

HbA1c3 PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee

HbF<2% 95-98% H b A %

References Required document for Laboratory Accreditation by the College of American Pathologists.

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

HbA1c HbA1c (Hemoglobin A1c)

Harmonization of Clinical Laboratory Results is Essential for Quality Patient Care

Comparative study of glycated hemoglobin by ion exchange chromatography and affinity binding nycocard reader in type 2 diabetes mellitus

Possible discrepancy of HbA1c values and its assessment among patients with chronic renal failure, hemodialysis and other diseases

on Venous and Capillary Blood Samples

Combined measurement of fasting plasma glucose and HbA1c is effective for the prediction of type 2 diabetes: The Kansai Healthcare Study

Rapid Hemoglobin A1c Testing for Evaluation of Glucose Control

Selecting a Risk-Based SQC Procedure for a HbA1c Total QC Plan

HEMOGLOBIN ELECTROPHORESIS DR ARASH ALGHASI SHAFA HOSPITAL-AHWAZ

IFCC Committee for Standardization of Thyroid Function Tests C-STFT- Update on the project

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing

HbA1c PRINCIPLE REF ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Professional Procedure Guide (90821B 04/2008)

Keywords: albuminuria; albumin/creatinine ratio (ACR); measurements. Introduction

Agenda. 15 Dec

Detection and quantitation of hemoglobin (Hb) fractions

for simultaneous management of diabetes and screening for thalassemia HbA 1c . We used Capillarys 2 Flex Piercing (Capillarys 2FP) HbA 1c

About the Project Education Play Community Games Publications News Help Home

Transcription:

Commentary Standardisation: History, Science and Politics *W Garry John, 1 Andrea Mosca, 2 Cas Weykamp, 3 Ian Goodall 4 1 Norfolk and Norwich University Hospital, and School of Medicine, Heath Policy and Practice, UEA, Norwich, UK, 2 Centro Interdipartimentale per la Riferibilità Metrologica in Medicina di Laboratorio (CIRME), Dip. di Scienze e Tecnologie Biomediche, Università degli Studi di Milano, Via Fratelli Cervi 93, 20090 Segrate, Milano, Italy, 3 Queen Beatrix Hospital, Winterswijk, The Netherlands, 4 Austin Health, Heidelberg, Victoria, Australia *For correspondence: Dr Garry John e-mail: g.john@nnuh.nhs.uk Abstract Significant analytical improvements have occurred since glycated haemoglobin (GHb), measured as total HbA 1, was first used in routine clinical laboratories around 1977. Following the publication of the Diabetes Control and Complications Trial (DCCT) study in 1993 the issue of international standardisation became an important objective for scientists and clinicians. The lack of international standardisation led several countries to develop national standardisation programs. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Working Group on Standardisation of established a true international reference measurement system for and the successful preparation of pure calibration material that should lead to further improvements in inter-method and inter-laboratory variability. Reporting of has been agreed using the units of mmol/mol (IFCC) and percent (National Glycohemoglobin Standardization Program, NGSP). History It is fascinating to consider the analytical improvements that have occurred since glycated haemoglobin (GHb), measured as total HbA 1, was first introduced into clinical laboratories for diabetes monitoring around 1977; at that time methods displayed poor precision, there were no calibrators or material with assayed values for quality control purposes. Many methods for the measurement of GHb have been developed; these mainly make use of charge or structural differences between the glycated and non-glycated species of haemoglobin. Methods based on charge difference From the late 1970s to the mid 1980s the major assays were either electrophoretic or mini-column assays for the chromatographic fraction HbA 1 and later the more specific subfraction. The mini-column assays were rapid short column variations of the original 1971 Trivelli macro-column procedure that took several days to perform. 1 Fractions were eluted in the order HbA 1a, HbA 1b, HbF,, HbA 0 and HbA 2 with buffers of varying ionic strength. To improve laboratory comparability the use of multilevel lyophilised bloods with values assigned by manufacturers using their own kit methods to determine the values became common. The use of temperature control was shown to achieve better precision than the use of calibrators for correcting temperature variation. Later developments and current HPLC assays based on cation exchange incorporate both thermostatted temperature control and the use of calibrators. Other assays based on charge differences are: agar gel electroendosmosis, agarose gel electrophoresis, isoelectric focusing, and capillary electrophoresis. These methods have been largely discontinued in the clinical laboratory. Methods based on structural difference Affinity Separation In 1981 Mallia et al. described a method that separated GHb based on the binding of the cis-diol groups of the glucose to m-amino phenylboronic acid cross-linked on agarose. 2 GHb binds to the affinity resin, whilst non-glycated haemoglobin does not bind. Quantitation is by spectrophotometry at 415 nm of the glycated and non-glycated fractions. This method is much less temperature sensitive and does not suffer from analytical interference from HbF and carbamylated haemoglobin, and has long been recognised as the method of choice in patients with haemoglobin variants. Calibration did not exist. Clin Biochem Rev Vol 28 November 2007 I 163

John WG et al. Affinity methods have now been adapted for use on automated chemistry analysers, and affinity gel HPLC is now widely used worldwide. Both adaptations are calibrated using the manufacturers material. Immunoassays In 1991 Dako Diagnostics Ltd. (Ely, UK) marketed the first commercial immunoassay, Novoclone, which used enzyme-linked microtitre plates with an antibody specific to the N-terminal eight amino acids of ketoamine. The assay was discontinued within a few years. In 1992 the DCA 2000 Point of Care analyser was introduced. This manual immunoassay analyser was originally marketed with an eight minute assay programme, and subsequently converted to a six minute assay. 3 Immunological based assays for became more widely used in the mid 1990s and many commercial assays are now available and are targeted against the β N-terminal glycated tetrapeptide or hexapeptide group. Assay design is variable, ranging from immunoturbidimetry to latex enhanced competitive immunoturbidimetry, and operating instructions are available for a large number of chemistry analysers. Science Following the introduction of methods into routine use, it quickly become apparent that there was a significant difference in the results produced by different laboratories. 4 It was evident that the disparate results obtained were due to the range of methods being used by laboratories and the lack of a primary reference material. Even though the new generation of methods now demonstrate a degree of precision that could not be imagined in the mid 1970s, comparison of results from different laboratories would still be at best difficult or more likely impossible if not for standardisation schemes. Standardisation with common calibration was first proposed in 1984 by Peterson et al., who examined factors such as intermethod correlation and reproducibility between laboratories. 5 However, it was only after the publication of the DCCT study in 1993 that the issue of international standardisation of glycated haemoglobin measurements became an important objective for scientists and clinicians. 6 The lack of international standardisation resulted in several countries developing national standardisation programs. USA: National Glycohemoglobin Standardization Program (NGSP) 7-9 The NGSP was formed in July 1996 to implement the plan developed by the American Association for Clinical Chemistry Glycohemoglobin Standardisation Subcommittee. The plan was to establish a system of reference laboratories that would support each other in a network that would be used to calibrate and standardise commercial methods and analytical systems. The BioRex 70 HPLC System, established in the DCCT Central Laboratory, was chosen as the NGSP reference standard method. The Missouri DCCT laboratory was established as the Central Primary Reference Laboratory (CPRL) for the NGSP. This laboratory sets the initial calibration for the NGSP Certification Programme as the set point as used in the DCCT. Primary Reference Laboratories (PRLs) were established to support the CPRL, the PRLs using the CPRL BioRex 70 HPLC method and a single haemolysate calibrator prepared by the CPRL with an established target value based on the mean of at least 50 CPRL runs. A number of Secondary Reference Laboratories (SRLs) were established to work directly with manufacturers to assist them in standardising commercial methods for Certification of Traceability to the CPRL BioRex 70 assay. The SRLs use established precise routine automated assays but must have these calibrated against the CPRL calibrator. The NGSP is responsible for the calibration of methods in many parts of the world enabling direct comparison to the DCCT targets. The NGSP has an excellent website and provides up-to-date information on the precision and accuracy of validated commercial methods for. 10 Japanese Standardisation Scheme 11,12 In 1995 the Japanese Diabetes Society (JDS) in collaboration with the Japan Society of Clinical Chemistry (JSCC) developed a National Standardisation Scheme. Two calibrators (JDS Calibrator Lot 1) were prepared as lyophilised haemolysates. The values were assigned as the mean of the two most common high-pressure liquid chromatography (HPLC) analysers, Tosoh (Tokyo, Japan) and Kyoto Daiichi (Kyoto, Japan), both very precise cation exchange methods. At the time, most Japanese laboratories were using one of these methods. These two point calibrators are used for the calibration of all routine assays in Japan. In 2000 a more specific high resolution cation exchange HPLC analyser KO500, developed by the JSCC, was adopted as the calibration method and a second set of National Calibrators (deep frozen blood) called JDS/ JSCC Calibrator Lot 2 were prepared. The values of these new calibrators were assigned using the KO500 analyser in four reference laboratories of the JDS /JSCC. To keep consistency with the Japanese Calibrator Lot 1 values, the Calibrator Lot 2 values were adjusted to those of the Calibrator Lot 1. 164 I Clin Biochem Rev Vol 28 November 2007

Standardisation - History, Science and Politics The JDS/JSCC calibrators are used by approximately 1800 laboratories in Japan. The effect of the calibrators has been a significant improvement in results between laboratories and a progressive decrease of mean inter-laboratory variation from values of more than 12% coefficient of variation (CV) to approximately 5%. Three Japanese reference laboratories are included in the IFCC Reference Laboratory Network. For all IFCC comparative studies that were used to establish the IFCC JDS Master Equations the KO500 method was calibrated with JDS Calibrator Lot 2. Swedish Standardisation Scheme 13,14 The Swedish standardisation scheme uses as its reference method the analysis of using Mono S HPLC (a strong methylsulfonate cation exchanger on monobeads, Pharmacia LKB Biotechnology, Uppsala, Sweden). Mono S is a relatively specific assay separating from all known minor endogenous components except carbamylated haemoglobin and α-chains. The HbF fraction is well separated. In 1998 common standardisation throughout Sweden was introduced. Five selected Swedish reference laboratories using Mono S HPLC assays assign values to pooled whole blood samples. These laboratories are used for the calibration of all hospital and point of care instruments in Sweden. Global Standardisation A common feature of these national programs is the absence of internationally recognised and accepted reference materials and measurement procedures to assure the accuracy and comparability of measurements at a global level. To address these shortcomings, and to achieve a uniform international standardisation of measurements, the IFCC established a Working Group on Standardisation (WG- ) with the aim to develop a complete reference measurement system based on the concepts of metrological traceability. In addition to reference methods and materials, essential elements of a comprehensive reference measurement system include the definition of the measurand (including the unit) in regards to the intended clinical use and the individuation of reference laboratories that possibly collaborate in a network. 15,16 For this project, the decision was made to define as haemoglobin molecules having a stable adduct of glucose to the N-terminal valine of the haemoglobin β chain (βn-1-deoxyfructosyl-haemoglobin). The rationale was that this quantity is biochemically well characterised, is the major form of in human blood, and most of the commercial tests claim to measure only this form. Two equivalent reference methods specifically measuring this hexapeptide were then developed, with a combination of HPLC and electron-spray mass spectrometry (MS) or, alternatively, a two dimensional approach using HPLC and capillary electrophoresis (CE) with UV detection. 17 The WG- was also successful in preparing primary reference materials (purified HbA 0 and ) to calibrate the reference procedures. 18 In 2001, the IFCC reference methods were unanimously accepted by the National Societies of Clinical Chemistry following a ballot and published as approved IFCC reference methods. 17 In the meantime, a network of laboratories was established, using either the HPLC-MS or the HPLC-CE option. Politics It soon became apparent that there were significant differences between the values of the IFCC Network laboratories and each of the three national networks designated comparison methods (DCMs), and also significant differences between each of the DCMs. But, in each individual case the relationship between each DCM and the IFCC was linear. The relationships of each DCM with the IFCC method have been stable and reproducible over several years, and are described by the following master equations: 19 NGSP = 0.915 (IFCC ) + 2.15 JDS/JSCC = 0.927 (IFCC ) + 1.73 Swedish = 0.989 (IFCC ) + 0.88 Table. Suggested units and target values for when measured with methods traceable to the IFCC reference system. 23 A comparison with the current figures is also given. Reprinted with permission from Walter de Gruyter. Current a IFCC traceable methods Reference interval (non-diabetics) 4 6% 20 42 mmol/mol Target for treatment in diabetics b <7% <53 mmol/mol Change of therapy in diabetics b >8% >64 mmol/mol a refer to methods aligned to the U.S. National Glycohemoglobin Standardization Program. b as recommended by American Diabetes Association. Clin Biochem Rev Vol 28 November 2007 I 165

John WG et al. The joint IFCC Committee on Nomenclature, Properties and Units and IUPAC (International Union of Pure and Applied Chemistry) Subcommittee on Nomenclature, Properties and Units (C-NPU) proposes mmol/mol be used as the unit of measurement for ; this represents the SI unit for this analyte. 20 This option, i.e. the use of a completely different unit (mmol/mol instead of percentage), will avoid confusion when recalculating old targets to the new IFCC standardised values if clinical laboratories wish to implement results traceable to the IFCC reference system (Table). Other advantages of this approach may include a positive impact of changing of scale of reported results allowing clinicians and diabetic patients to better understand the analyte changes and increased potential for future use of as a diagnostic tool. 21 Currently clinicians and patients may perceive small changes as unimportant, although they are linked to large health effects. The impact of both changes proposed by IFCC would be to significantly change the numeric results provided to clinicians. To discuss a joint approach an initial meeting was held in London in January 2004 between the International Diabetes Federation (IDF), European Association for the Study of Diabetes (EASD), the American Diabetes Association (ADA), the IFCC WG- and a representative of the NGSP. 22 This meeting suggested a way forward was to report in terms of average plasma glucose, and a study (Mean Blood Glucose Study) was organised to investigate this relationship. To progress discussion relating to the new reference method to standardise the results, along with the anticipated documentation that the assay does indeed indicate average blood glucose, a further meeting was held in Milan, Italy on 4 May 2007, at which a consensus agreement emerged. The following statements have been approved by the ADA, EASD, IDF and IFCC: 23 1. test results should be standardised worldwide, including the reference system and results reporting. 2. The new IFCC reference system for represents the only valid anchor to implement standardisation of the measurement. 3. results are to be reported worldwide in IFCC units (mmol/mol) and derived NGSP units (%), using the IFCC-NGSP master equation. 4. If the ongoing average plasma glucose study fulfils its a priori specified criteria, an derived average glucose (ADAG) value calculated from the result will also be reported as an interpretation of the results. 5. Glycaemic goals appearing in clinical guidelines should be expressed in IFCC units, derived NGSP units and as ADAG. The committee states that all the organisations agreeing with this consensus statement propose that these recommendations be implemented globally as soon as possible. Figure. Example of a patient chart showing IFCC, NGSP and estimated average glucose (eag).* Data taken from DCCT outcome while ongoing study results are awaited. 166 I Clin Biochem Rev Vol 28 November 2007

Standardisation - History, Science and Politics We now have full agreement that the IFCC reference measurement system is the anchor for global standardisation of measurements and the values should be reported in mmol/mol and NGSP values (%) should be derived and also reported. In September this year the results of the Mean Blood Glucose Study were presented during the EASD meeting and several clinical societies supported the reporting of an estimated average glucose (eag). One approach to the reporting of eag is as a comment to the results. An example of how these results can be combined is shown in the Figure. This new initiative to express test results in scientifically correct units along with a clinically relevant interpretation of those results is not an uncommon practice (e.g. creatinine and estimated GFR). Consequently, clinicians will have the opportunity to convey the concept of chronic glycaemia in terms and units most suitable to the patients under their care. The challenge now is to implement these recommendations globally; this will involve clinicians, biochemists, external quality assessment organisers, patient groups and manufacturers undertaking a large scale educational program. It is vital that all relevant parties are aware of the implications and benefits of these changes. When adopted we can be sure of true global standardisation of. Acknowledgements Members of the IFCC WG- : Garry John (UK; Chairman), Andrea Mosca (Italy; Secretary), Cas Weykamp (Netherlands; Network Coordinator), Ian Goodall (Australia), Tadao Hoshino (Japan), Jan-Olof Jeppsson (Sweden), Patricia Kaiser (Germany), Randie Little (USA), Gary Myers (USA) Hans Reinauer (Germany), David Sacks (USA) and Robbert Slingerland (Netherlands). Competing Interests: None declared. References 1. Trivelli LA, Ranney HM, Lai HT. Hemoglobin components in patients with diabetes mellitus. N Engl J Med 1971;284:353-7. 2. Mallia AK, Hermanson GT, Krohn RI, Fujimoto EK, Smith PK. Preparation and use of a boronic acid affinity support for separation and quantitation of glycosylated hemoglobins. Anal Lett 1981;14:649-61. 3. John WG, Edwards R, Price CP. Laboratory evaluation of the DCA 2000 clinic HbA1c immunoassay analyser. Ann Clin Biochem 1994;31:367-70. 4. Boucher BJ, Burrin JM, Gould BJ, John PN, Lewis G, Owens C, et al. A collaborative study of the measurement of glycosylated haemoglobin by several methods in seven laboratories in the United Kingdom. Diabetologia 1983;24:265-71. 5. Peterson CM, Jovanovic L, Raskin P, Goldstein DE. A comparative evaluation of glycosylated haemoglobin assays: feasibility of references and standards. Diabetologia 1984;26:214-7. 6. The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977-86. 7. Little RR. The National Glycohemoglobin Standardization program (NGSP). In: WG John, editor. Monitoring Glycaemic Control in the Diabetic Patient. London: Hartcourt Health Communication, Mosby International Limited; 2001. p 123-36. 8. American Diabetes Association. Position statement: Tests of glycemia in diabetes. Diabetes Care 1998;21: S69-71. 9. Little RR, Rohlfing CL, Wiedmeyer HM, Myers GL, Sacks DB, Goldstein DE. The National Glycohemoglobin Standardization Program: a fiveyear progress report. Clin Chem 2001;47:1985-92. 10. National Glycohemoglobin Standardization Program (NGSP). www.ngsp.org (Accessed 25 October 2007) 11. Shima K, Endo J, Oimomi M, Oshima I, Omori Y, Katayama Y, et al. Interlaboratory differences in HbA1c measurement in Japan, an interim report of the committee on an interlaboratory standardization of HbA1c determination, the Japan Diabetes Society. J Japan Diab Soc 1994;37:233-43. 12. Shima K, Endo J, Oimomi M, Omori Y, Katayama Y, Kanazawa Y, et al. Interlaboratory differences in GHb measurement in Japan, the fifth report of the GHb standardization committee, the Japan Diabetes Society. J Japan Diab Soc 1998;41:317-23. 13. Eckerbom S, Bergqvist Y, Jeppsson JO. Improved method for analysis of glycated haemoglobin by ion exchange chromatography. Ann Clin Biochem 1994;31:355-60. 14. Mosca A, Paleari R. Standardization schemes for hemoglobin A1c determination. In: WG John, editor. Monitoring Glycaemic Control in the Diabetic Patient. London: Hartcourt Health Communication, Mosby International Limited; 2001. p 137-50. 15. Hoelzel W, Miedema K. Development of a reference system for the international standardization of HbA1c/ glycohemoglobin determinations. J Int Fed Clin Chem 1996;9:62-7. Clin Biochem Rev Vol 28 November 2007 I 167

John WG et al. 16. Panteghini M, Forest JC. Standardization in laboratory medicine: new challenges. Clin Chim Acta 2005; 355:1-12. 17. Jeppsson JO, Kobold U, Barr J, Finke A, Hoelzel W, Hoshino T, et al. Approved IFCC reference method for the measurement of HbA1c in human blood. Clin Chem Lab Med 2002;40:78-89. 18. Finke A, Kobold U, Hoelzel W, Weykamp C, Miedema K, Jeppsson JO. Preparation of a candidate primary reference material for the international standardisation of HbA1c determinations. Clin Chem Lab Med 1998;36:299-308. 19. Hoelzel W, Weykamp C, Jeppsson JO, Miedema K, Barr J, Goodall I, et al. IFCC reference system for measurement of haemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. Clin Chem 2004;50:166-74. 20. Nordin G, Dybkær R. Recommendation for term and measurement unit for HbA1c. Clin Chem Lab Med 2007;45:1081-2. 21. Kilpatrick ES. HbA1c or glucose for diabetes diagnosis? Ann Clin Biochem 2005; 42:165-6. 22. Sacks DB, ADA/EASD/IDF Working Group of the HbA1c Assay. Global harmonization of hemoglobin A1c. Clin Chem 2005;51:681-3. 23. Panteghini M, John WG. Implementation of haemoglobin A1c results traceable to the IFCC reference system: the way forward. Clin Chem Lab Med 2007;45:942-4. 168 I Clin Biochem Rev Vol 28 November 2007