Junctional Emergency Treatment Tool Item#: NSN#:

Similar documents
Combat Ready Clamp. Medic/Corpsman carried device Aidbag-based. Partially broken down 1.5 lbs

Abdominal Aortic and Junctional Tourniquet AAJT

LESSON ASSIGNMENT. After completing this lesson, you should be able to:

weight.detach/bench ITEM NO: 76310

Speed, Control & Targeted Compression without Complexity. Lorem Ipsum 2

EndoRelease ENDOSCOPIC CUBITAL TUNNEL RELEASE SYSTEM

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

SelectTech 3.1 Bench Assembly / Owner s Manual

TM TM Surgical Technique

Single-Thread Screw Available in 25-45mm lengths (5mm Increments) Dual-Thread Screw Available in 30-45mm lengths (5mm Increments)

DFS STANDARD FIXATOR DFS ANKLE CLAMP DFS T-CLAMP

InSWing. Unilateral, Minimal Invasive Interspinous Spacer INTERNATIONAL EDITION

Important Safety Instructions 1-2. Maintenance 3. Features 4. Assembly Parts List 5. Assembly Instructions 6-9. Console Operation 10

AcUMEDr. Arc Wrist Tower. For Wrist Arthroscopy And Fracture Reduction

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

Cardiva Catalyst III INSTRUCTIONS FOR USE

BAK/C Cervical Anterior Interbody Fusion System

LESSON ASSIGNMENT. After completing this lesson, you should be able to: be able to:

Cybex Leg Extension. Legs

FLx. USER INSTRUCTIONS Version. 01 STRONGARM ERGOSKELETON. Postural Support Device FLx

The specifications of this product may vary from this photo and are subject to change without notice. For Customer Service, please contact:

Surgical Technique. CONQUEST FN Femoral Neck Fracture System


Sunny Magnetic Exercise SF-B910

IMPORTANT INFORMATION - PLEASE READ. Table of Contents. Introduction. General Information

NewBridge. Laminoplasty Fixation INTERNATIONAL EDITION

User Guide. Rev 2, 10/27/2015

KneeAlign System Surgical Technique Guide

Title: EZ-IO. Effective Date: January SOG Number: EMS Rescinds:

CLARIVEIN INFUSION CATHETER

QUICK REFERENCE GUIDE. The XCaliber Meta-Diaphyseal Fixator

Skin is the largest, most important organ % of total body weight Functions: - -Sensation - Regulation AKA: System

USER MANUAL Rev. 1.15

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

EXERCISE INSTRUCTIONS

Trilogy Acetabular System

V22 V22. USER INSTRUCTIONS Version. 01 STRONGARM ERGOSKELETON. Lift Assist Device

Large Distractor Femur

InCoreTM Lapidus System

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

Mini External Fixator.

Sacral, ilioinguinal, and vasal nerve stimulation for treatment of pelvic, sacral, inguinal and testicular Pain.

Back Safety Healthcare #09-066

PAL Pelvic Alignment Level

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

PediLoc Tibia Surgical Technique

SPINAL IMMOBILIZATION

GAMMA LOCKING NAIL INSTRUMENTS OPERATIVE TECHNIQUE

LCP Distal Humerus Plates

Pre-Operative Planning. Positioning of the Patient

Access Pelvic Fixator

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

designed to advance the treatment of hip fractures.

Axi+LineTM Proximal Bunion CorrectionSystem. Surgical Technique

- 1 - INSTRUCTION MANUAL

Biomet Large Cannulated Screw System

Bledsoe Extender Brace Application Instructions CP Rev D 03/07

Zimmer Small Fragment Universal Locking System. Surgical Technique

SelectTech 4.1 Bench Assembly / Owner s Manual

Extracapsular Repair Monofilament Nylon Suture

T-PODResponder Pelvic Stabilization Device

Operating Instructions. Stryker Rugged Stair-PRO Stair Chair Model 6252 (SWL 35 stone 227 kg 500 lb)

Dedication to Quality

MX SELECT OWNER S MANUAL. Revolutionising Strength Training REGISTER YOUR PRODUCT AT MXSelect. MX_Select.

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Surgical Technique Guide

ANJON BREMER LIGHT VEST

Multipower. User Guide E S S E N T I A L S T R E N G T H

Patient Lifter (Hydraulic Lift) Information for the Patient A Guide for Patients in the Home

Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

LESSON ASSIGNMENT. After completing this lesson, you should be able to:

System. Humeral Nail. Surgical Technique

Hip arthroscopy using the Smith & Nephew Hip Access System

HP KNEE EXTRACTION Instrumentation. Product Overview

PROFESSIONAL GRADE FITNESS CABLES INSTRUCTION MANUAL AND EXERCISE GUIDE. Engineered by

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

How to use the Control-Cric to perform a surgical cricothyrotomy

Technique Guide KISSloc Suture System

ULTR A SERIES G7-S75

O W N E R S M A N U A L

CHAPTER 28 Musculoskeletal Injuries

Musculoskeletal System

TECHNICAL BROCHURE. Capture Facet Fixation System

TABLE OF CONTENTS. Warning Label...1. Important Safety Instructions...2. Parts List...5. Assembly Instructions...6. Additional DVD Workouts...

JUNCTIONAL TOURNIQUET EFFECTOR HEAD: MINIMAL FORCES AND PRESSURES PRODUCING OCCLUSION.

INGUINAL HERNIA REPAIR PROCEDURE GUIDE

DISTRACTION PRODUCT OVERVIEW. For a wide variety of facial applications

Lumbar/Core Strength and Stability Exercises

Bone Graft Harvesting System. Surgical Technique

LEVEL 1 Full-Body Resistance Band Workout

Monolateral External Fixation System for Trauma and Orthopaedics

Cervical Solutions. Optio-C Anterior Cervical Plate. with Allograft/Autograft. Surgical Technique Guide

Multiplane Stabilizer

Transcription:

Junctional Emergency Treatment Tool Item#: 30-0088 NSN#: 6515-01-616-5841 35 Tedwall Ct. Greer, SC 29650

Anatomy of the JETT (Junctional Emergency Treatment Tool)

Instructions Overview The Junctional Emergency Treatment Tool (JETT ) includes two individually adjustable compression pads in a single tool, allowing for simultaneous occlusion of blood flow to both lower limbs (bilateral) with an easy to apply, pre-assembled, ready-to-use belt solution. The unique design of the JETT allows for patient transport while the device is in place and includes a lanyard and toggle solution to ensure that the Threaded T- Handle (windlass axle) does not loosen due to vibration or bumps during transport. In cases where there are bilateral injuries, the JETT offers a simple, safe solution for occluding blood flow to both lower extremities. This expanded capability is built into every JETT, meaning that with standardized training the device will be prepositioned for rapid bilateral application whether the casualty requires a unilateral or bilateral treatment. High extremity wounds in the thigh/groin region where tourniquets cannot be placed or are less effective require equipment such as the JETT to stop the bleeding and potentially save the life of a casualty that would otherwise bleed out in minutes. Penetrating trauma, blast injuries and amputation are examples of injuries that may require treatment with this device.

Inguinal Anatomy

STEP 1: PATIENT ASSESSMENT 1.1 Determine that the injury is not amenable to treatment with a standard tourniquet (ie: high in the thigh and/or groin region) 1.2 Determine if a bilateral or unilateral application is required

STEP 2: PATIENT PREPARATION 2.1 Remove any gear, items in pockets or debris that might interfere with the placement of the JETT or cause additional trauma.

STEP 3: DEVICE DEPLOYMENT 3.1 Unroll the device in preparation for application

STEP 3.2: PLACEMENT of the JETT 3.2.A Slide the belt with This Side Toward Casualty facing up under the body at the lower back 3.2.B Locate the Superior Iliac Crest and Pubic Bone, which are connected by the Inguinal Ligament 3.2.A 3.2.B

STEP 3.2: PLACEMENT of the JETT 3.2.C Lifting the hips, position the belt under the buttocks so that the buttocks pad is centered behind the casualty and the pressure pads are immediately below (inferior to) the Inguinal Ligament

STEP 3.3: PLACEMENT of PRESSURE PADS 3.3.A 3.3.B 3.3.C Palpate to determine the location of the Inguinal Ligament Angle the pressure pads parallel to the Inguinal Ligament (approximately 30 ) pointing midline toward the feet making sure that both pads are correctly positioned Ensure that casualty s genitals are clear of the area where the pads will be positioned 3.3.B

STEP 3.4: BUCKLE & TIGHTEN 3.4 Buckle the belt, then firmly tighten by pulling the loop handle while stabilizing the belt with your other hand on top of the belt on the casualty (remove ALL slack)

STEP 3.5: REASSESS PAD PLACEMENT 3.5 Reassess the pad placement to ensure that they are still in the correct location below the inguinal ligament

STEP 3.6: TIGHTEN 3.6 With one hand on the base plate, grip the threaded T-handle and rotate it clockwise to tighten

STEP 3.7: HEMOSTASIS 3.7 Increase pressure until bright red bleeding stops (hemostasis is achieved) and If the extremity is intact, check to confirm that distal pulse has been occluded

STEP 3.8: LOCK 3.8 Insert the toggle into the opening on the threaded T-handle (pulling the handle in clockwise rotation) and cinch it tight at the base plate in order to secure the device

STEP 3.10: RECORD TIME 3.9 Repeat as necessary with the other threaded T-handle for bilateral injuries 3.10 Note time of application on Writeable Area

STEP 4: MONITOR 4.1 Assess frequently (every 5 minutes) to ensure that bleeding is still controlled (or based on your medical protocols) 4.2 Assess after any movement to ensure that pressure pads are in correct location and that pressure was not reduced during movement (hemostasis is maintained) 4.3 Device should only be removed under physician supervision (or based on your medical protocols) 4.4 Device application should not exceed 4 hours

Warning: Warnings & Cautions Do not leave applied for longer than 4 hours Inguinal use only Caution: For use by trained personnel Tighten until hemostasis is achieved Reassess casualty condition after movement or every 5 minutes (or based on your medical protocols) Caution: Federal law restricts this device to sale by or on the order of a physician