Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Similar documents
Dosisverifikation mit Delta 4 Discover während der Behandlung

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Leila E. A. Nichol Royal Surrey County Hospital

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Realtime dose monitoring technologies: Luxury or Necessity

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Volumetric Modulated Arc Therapy - Patient Specific QA

Small field diode dosimetry

DELIVERED PATIENT DOSE

iviewdose Confidence and assurance in dose delivery

IMRT QA: Point Dose Measurements or 2D Array?

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

Use of Electronic Portal Image Detectors for Quality Assurance of Advanced Treatments

EORTC Member Facility Questionnaire

Limits of Precision and Accuracy of Radiation Delivery Systems

REPLACING PRETREATMENT VERIFICATION WITH IN VIVO EPID DOSIMETRY FOR PROSTATE IMRT

Effective and efficient radiotherapy dosimetry audit: Where to next?

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

SunCHECK Patient Comprehensive Patient QA

Measurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry

Evaluating Pre-Treatment IMRT & VMAT QA Techniques Using Receiver Operating. Characteristic (ROC) Analysis. Allison Lorraine Mitchell

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Eric E. Klein, Ph.D. Chair of TG-142

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

Quality Assurance in Radiation Therapy

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Elekta Synergy Digital accelerator for advanced IGRT

Quality assurance in external radiotherapy

Online Care, Online Control, Online Confidence

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

SRS Uncertainty: Linac and CyberKnife Uncertainties

7/16/2009. Cost-benefit, QALYs and the Value of a Statistical Life

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

The MapCHECK Measurement Uncertainty function and its effect on planar dose pass rates

SRS/SBRT Errors and Causes

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Dose rate response of Digital Megavolt Imager detector for flattening filter-free beams

EPID dosimetry for pretreatment quality assurance with two commercial systems

VMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

QA for Clinical Dosimetry with Emphasis on Clinical Trials

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

Patient and Linac QA - present and the future

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

IMRT Planning Basics AAMD Student Webinar

Pre-treatment and in-vivo dosimetry of Helical Tomotherapy treatment plans using the Dosimetry Check system

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

IMRT Implementation And Patient Specific Dose Verification With Film And Ion Chamber Array Detectors

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

PGY-1. Resident Review Session Schedule

Risk-based QM for Incorrect Isocenter at Day 1 Setup. TG 100 risk based QM development Process Mapping

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

Feasibility of portal dosimetry for flattening filter-free radiotherapy

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Verification of Advanced Radiotherapy Techniques

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

QUARTERLY REPORT PATIENT SAFETY WORK PRODUCT Q J A N UA RY 1, 2016 MA R C H 31, 2016

Independent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA

Unrivaled, End-to-End

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy

TomoTherapy Patient Quality Control With Dosimetry Check Version 5 Release 8. Math Resolutions, LLC 5975 Gales Lane Columbia, MD USA 21045

MEDICAL PHYSICS INTERNATIONAL Journal, vol.3, No.2, 2015 HOW TO

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Work partially supported by VisionRT

Amendment No. 2. Item No. 2 (Rfx/ Event number )

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Radiotherapy In-vivo Treatment Verification: Multi-center analysis for more than 6 million fractions delivered

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Efficient Dosimetry for Proton Therapy

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

A new geometric and mechanical verification device for medical LINACs

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Portal dosimetry in wedged beams

A review of RTTQA audit. Karen Venables

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

Reporting of Errors. Linda Harvey Quality Manager UCLH 28 th September 2012

Transcription:

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program? Can you currently use direct documentation and measurement of delivered dose to ensure you did not underdose or overdose a patient for any delivered fraction? If the answer is no, read on. Over the last couple of decades, radiation therapy planning and delivery techniques have evolved substantially, leading to IMRT, IGRT, VMAT, and SBRT/SRS, to name a few. The development of these new techniques, however, has led to an increasing amount of complexity during the radiation therapy treatment planning and delivery process. What is common sense isn t common practice. Stephen Covey When it comes to quality assurance for radiation therapy, the one aspect that matters above all else is the dose delivered to the patient. Equating time to dose (Co60) and MU (monitor units) to dose in the era of the Linac made sense, but since the advent of IMRT treatments, where the fluence is perturbed and modulated, there is no clear correlation between dose delivered with time and MUs. This means that there is no direct way of documenting the actual dose delivered to patients at every fraction. Moving to a hypofractionated treatment regime means the need for online dose verification becomes even more critical, yet we still cannot ensure accurate dose delivery by direct measurement for every fraction. Why? Because while progress was made in other areas of medical physics (namely delivery technology, imaging technology, etc.), the QA technology to measure actual dose in real time did not keep pace, and was not available when these complex delivery techniques were introduced. Q: I am doing a pretreatment patient specific QA, doesn t that ensure correct delivery? A: The pretreatment QA merely checks the machine s deliverability, and ensures the physics of the planning system s ability to model small field output. The pretreatment QA doesn t tell what is happening during the actual treatment at every fraction, with every beam and for every field. What will happen on the 10 th fraction of the 3 rd arc, for example, is still unknown. Q: I am doing weekly chart checks and making sure all the parameters are consistent & correct, doesn t that ensure correct delivery? A: The weekly chart checks ensure that all the delivery parameters on the machine are intact, but cannot guarantee the accuracy of the actual dose delivered during treatment. If you assume identical Linac behavior, it s possible to correlate the dose delivered with pretreatment QA parameters and the dose delivered with at treatment parameters. However, this is an assumption made without independent validation and is not an assurance of the actual dose delivered in real time because a) there is no direct measurement of dose delivered, and b) the

behavior of the Linac during pretreatment and actual treatment cannot be determined solely with chart review. Q: I have a rigorous machine QA program, doesn t the machine itself have interlocks? A: Machine QA is preventive maintenance, and ensures output consistency on a daily, weekly, or monthly basis. It does not guarantee patient treatment delivery accuracy of the specific treatment plan itself, or the machine parameters. Q: So, does that mean that our current treatments are not safe? A: Currently, we use the combination of pretreatment patient specific QA, machine QA and chart review to determine that a treatment is safe, and to prevent errors in future treatments. While these lead to the logical and solid assumption that the treatment we are delivering is safe, they are merely tests of the parameters of the machine and the plan itself, and can t identify actual errors that might occur. Q: What then, is the common sense approach to dose delivery verification for every fraction of every treatment? A: The common sense approach to real time dose delivery verification is to use a technology such as a transmission detector to measure the dose delivery error from the machine and combine it with set up errors and anatomy changes from IGRT. Combining these tools allows for the identification of the dosimetric impact of delivery set up errors and independent assurance or validation with real time direct dose measurement of the dose delivered to the patient. Once the source of delivery errors is identified, clinicians can make real time decisions and adjustments during the period of the treatment. Q: Isn t the machine log file a viable option for in vivo dosimetry? A: For in vivo dosimetry to truly be accurate, verification must be independent from the delivery system. Since the machine log information comes from the machine itself, it could report correct settings and results even if there are actual errors. If, for example, the dose rate is too low, the machine will make adjustments, but if the MU chamber reading is inaccurate, the machine s control system will adjust the dose rate for that dose and the log will then report correct data, even though the adjustment was made based on an incorrect measurement. Therefore, despite an accurate log file, the actual delivered dose could be inaccurate. This same situation can also happen with gantry and collimator angle settings. Since MLC miscalibration cannot be detected, incorrect MLC leaf motion paths are possible and will not show up in the log file. Log file based in vivo dosimetry can give a false sense of accuracy. Q: Isn t EPID based exit dosimetry an option? A: The idea of EPID exit dosimetry has been around for more than 20 years, but has some issues.

Issue #1 The source of potential error (patient or machine) cannot be determined since there are several scenarios that would yield the same exit dose. Also, without knowing the incident fluence, it is not possible to predict dose errors and the location of the errors in the patient. Issue #2 EPID is not primarily designed for dose measurement, although there have been several notable studies that have demonstrated its applicability for pretreatment QA. Additionally, in the presence of scatter, the behavior of the EPID will create false positives. While there are studies that have shown the effectiveness of machine log files [1] and EPID in detecting errors [2], it is not acceptable to have false positives when designing a dose monitoring system to ensure dose delivery accuracy for patients. EPID based exit dosimetry is not a common sense approach to dose delivery assurance for every fraction and every treatment. Errors should be measured separately and combined for dosimetric effect. Issue #3 Cost. A report from NKI, Amsterdam (who works closely with vendors in developing an EPID based in vivo solution and has used EPID frequently for the first three fractions of a treatment), reports that the average lifetime for the EPID in such use is 32 months [9]. Even under a service and maintenance agreement, this is an expensive replacement, which cannot be ignored, as such EPID use will result in image degradation [9], which is the main intended function of the EPID device. Qualitative analysis of QA technique effectiveness in catching potential discrepancies Table 1 shows different QA techniques and their effectiveness in catching errors. The first three columns are the extension of the table published in [5] for the purpose of this analysis. Highlighting has been added for clarity. Data Transfer, Delivery Error, Point Dose, Planning Error Type Transmission Detector + laser detection of pt position EPID Exit Dosimetry + Dynalog EPID Exit Dosimetry CT dose calc DynaLog QA d Point Dose Measurement a Field-by- Field Planar Dose QA b Composite Planar Dose QA c Independent Dose Calculation QA e Beam Parameters Discrepancy During Data Transfer or Machine Delivery Gantry Angle 1 1 2 1 3 5 4 5 Collimator Jaw Setting 1 1 3 1 3 3 3 5 Collimator Angle 1 1 3 1 3 3 3 5 MLC Positioning Error 1 1 3 1 4 3 3 5 MUs 1 3 3 5 1 1 3 5 Couch Angle Error 2 3 3 5 2 5 2 5 Machine Issues / Data Transfer Issues Dosimetry Characteristic Energy Change, Symmetry, and Flatness Off 1 3 3 5 4 4 4 5 Absolute Dose Output Calibration 1 3 3 5 5 5 5 5 Relative Dose Output Small Field Output Off 1 5 5 5 1 1 1 5 One Segment Dropped Out or Not Transferred Properly 1 1 4 1 4 3 4 5 One Field Not Transferred Correctly 1 1 2 1 4 2 3 5 Demanding MLC Sequence or MLC Positioning Issues Beam Hold Off 1 1 3 1 4 4 4 5

TPS Beam Modeling Issues Small Field Out Prediction Issue 1 3 3 5 2 2 2 1 Heterogeneity Correction Issues 1 3 3 5 5 5 5 1 Wrong CT to ED 1 2 3 5 5 5 5 2 DVH Calculation Discrepancy 1 3 3 5 5 5 5 1 In vivo Changes Beam Data Modification After Pretreatment QA and Other Machine Issues During Each Fraction IGRT Issues 1 3 3 5 5 5 5 5 Anatomy Changes, localization Issues, Set-up Issues 5 3 3 5 5 5 5 5 Treatment Planning Isocenter Placement, Prescription, Wrong CT Voxel Size, Plan Quality 5 5 5 5 5 5 5 5 28 46 60 67 70 71 71 80 Note: 1 is most effective, 4 is least effective, and 5 is not possible to find from QA test results. a Point dose measurement refers to ion chamber measurement with one or two points in a composite fashion (i.e., all beam delivered to a water equivalent phantom as it would be delivered to the patient). b Field-by-field planar dose measurement: all beams delivered from AP direction with gantry and could reset to default position. c Composite planar dose QA refers to measuring a plane using a 2D detector embedded in a phantom and the QA is performed with actual beam parameters as it will be delivered to the patients. d DynaLog QA: analysis of machine log file collected by delivering the actual plan to air or during composite point or planar dose measurement, as explained in a) and c). e Independent dose calculation is verifying the dose distribution of the planning system by recalculating in an independent dose calculation by exporting DICOM RT files (Plan, Dose, Images, Structure set) and any POIs. Q: How safe is radiation therapy? A: While radiation therapy is generally considered safe, over the last three decades, at least 3,000 patients have been affected by radiotherapy incidents, with medical radiation accidents accounting for more acute radiation deaths than any other source. In 2010, there was a series of New York Times articles that highlighted safety as a major weakness in our field [3]. Figure 1.1 from Radiotherapy Risk Profile report by the World Health Organization (2008) identifies commissioning, planning, treatment transfer and treatment delivery as the major contributors to errors in our field [4].

Since radiation therapy errors are not adequately reported, it is hard to accurately predict the error rate, and there is currently no way to know if a patient is over dosed, under dosed or even treated correctly. We have a moral obligation to our patients to monitor their treatment quality. Medical errors are the third largest cause of death in the U.S., following heart disease and cancer [6]. While powerful in its ability to treat cancer, radiation therapy has not yet achieved the overall quality control found in other areas of healthcare, such as anesthesia, or in other industries, such as aviation. More safety research and development of robust tools to ensure accurate QA and dosimetry are needed for the continued growth of radiation oncology. Delta 4 Discover: Effectiveness and Efficiency Delta 4 Discover is an ultra thin transmission detector, which enables accurate dose delivery verification at treatment, in the patient anatomy, and for every treatment fraction in real time. With Delta 4 Discover, you can ensure that your patients are treated according to the dose prescription while immediately detecting dosing errors in critical structures. Q: Is it FDA cleared? A: Yes, the Delta 4 Discover technology is FDA 510 (k) cleared. Q: How does Delta 4 Discover work? A: The Delta 4 Discover system measures the dose delivered by the accelerator, and automatically checks it against your user defined pass fail criteria. Combined with patient CT, you can see the dose that has been delivered to the patient.

Q: What information does Delta 4 Discover provide? A: Besides verification of the dose delivered to the patient, Discover s 4040 diodes can detect sub mm errors in MLC position [7, 8] and collimator and gantry angle differences during delivery. A distance indicator provides an extra check of patient set up. Q: How easy is it to use Delta 4 Discover? A: The Discover workflow is completely automated. It is placed on the head of the Linac and interfaced with the R&V, then automatically analyzes the predicted and actual delivered dose to the patient, providing real time feedback. Q: Do I need to correct attenuation in the planning system? A: Due to the ultra thin design of the detector, attenuation and beam hardening are minimal. At 10cm, attenuation is 1.2% for 6 MV and 0.1% for 18MV. Beam hardening at 10 cm depth for 6MV is 0.7% and 18 MV is 0.6% [7]. Q: Does Delta 4 Discover calculate CBCT dose? A: The current version of Delta 4 Discover calculates the dose delivered during the planning CT. We recommend calibrating Delta 4 Discover with a Delta 4 Phantom+. After calibration, dose data can be viewed immediately in 3D with time resolution, control point by control point. After combining measurements with CT data, the dose can be viewed in patient anatomy as dose distribution and DVH. For further analysis and to find causes of deviations, the time resolved measurements enable visualization of the 3D dose distribution per sub arc or control points. Q: What does Delta 4 Discover mean to the patient and the overall therapy program? A: Peace of mind. With independent verification, both you and your patient can now be confident of safe treatment and that the treatment dose is delivered as planned. Safety is an Investment, Not a Cost! A reliable organization will seek to utilize the latest technology in patient safety, and transmission detectors currently play a key role in this field. It is imperative that we continue to pursue the latest advancements in QA and develop programs that include the latest technology whenever possible. With the Delta 4 Discover transmission detector, common sense can become common practice. Being able to document the delivery quality for every treatment fraction, beam and control point is a major step towards increasing patient safety throughout the entire treatment process.

References [1] D Rangaraj, et.al., Catching errors with patient specific pretreatment machine log file analysis, Practical Rad.Onc. 3(2), 80 90 (2013) [2] A Mans, et.al., Catching errors with in vivo EPID dosimetry, Med. Phys., 37, 2638 (2010) [3] Walt Bogdanich, Radiation offers new ways to cure and ways to do harm http://www.nytimes.com/2010/01/24/health/24radiation.html, Jan 2010 [4] Radiotherapy Risk Profile report by the World Health Organization (2008) [5] Sun, Rangaraj, et al.: Independent dose calculation and DynaLog QA, JACMP Vol.13, No.5, 2012 [6] Martin A Makary, Michael Daniel, Medical error the third leading cause of death in the US BMJ 2016;353:i2139 doi: 10.1136/bmj.i2139 (Published 3 May 2016) [7] Saenz D, Gutierrez A, Characterization of the Clinically Released ScandiDos Discover Diode Array for In Vivo Dose Monitoring, Med Phys, Volume 43, (6) 2016 [8] Taoran Li et al, Diode based transmission detector for IMRT delivery monitoring: a validation study. JACMP. 17 (5) 2016. [9] Ben J. Mijnheer PhD, Patrick González PhD, Igor Olaciregui Ruiz MSc, Roel A. Rozendaal MSc, Marcel van Herk PhD, Anton Mans PhD, Overview of 3 year experience with large scale electronic portal imaging device based 3 dimensional transit dosimetry Department of Radiation Oncology, Practical Radiation Oncology5, e679 e687 (2015)