Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Similar documents
Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

CT Dose Reduction in Pediatric Patients

People Exposed to More Radiation from Medical Exams

CT Quality Control Manual FAQs

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

How to Develop CT Protocols for Children

CT Radiation Risks and Dose Reduction

Justification, Optimization and Communication in Pediatric CT Imaging: Recent Improvements and Persistent Challenges Designated Emphasis in Nuclear

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Low Dose Era in Cardiac CT

Automatic Patient Centering for MDCT: Effect on Radiation Dose

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

Seattle Children s Hospital Radiology Department. Statement regarding radiation exposure related to computed. tomography (CT) exams

The Increasing Use of CT and Its Risks

Introduction Pediatric malignancies Changing trends & Radiation burden Radiation exposure from PET/CT Image gently PET & CT modification - PET/CT

THE UTILIZATION OF A DOSE MANAGEMENT SOLUTION TO LOWER RADIATION DOSES IN MEDICAL IMAGING

Optimizing radiation dose by varying age at pediatric temporal bone CT

Staging Colorectal Cancer


Regional diagnostic reference levels and collective effective doses from CT scanners in India

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Managing Radiation Risk in Pediatric CT Imaging

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Managing Patient Dose in Computed Tomography (CT)

Cardiac CT Techniques in Neonates (and infants)

BENEFITS OF CT AND HOW LEADING ACADEMIC INSTITUTIONS ARE COMMUNICATING RISK TO PATIENTS. James A. Brink, MD Massachusetts General Hospital

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

IMAGE GENTLY HOW CAN YOU HELP?

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Why is CT Dose of Interest?

Fetal Dose Calculations and Impact on Patient Care

Radiation Dose in Pediatric Imaging

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

Radiation Dose Reduction Strategies in Coronary CT Angiography

Radiation dose of cardiac CT what is the evidence?

CT Screening for Lung Cancer for High Risk Patients

Radiation Exposure 1980 to 2006

Introduction and Background

Dual-Energy CT: The Technological Approaches

TITLE: Computed Tomography: A Review of the Risk of Cancer Associated with Radiation Exposure

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

IOWA RADIOLOGY 1. Guide to CT Scans Clive Downtown Des Moines

Aquilion ONE: Pediatric Imaging. Richard Mather, PhD. Senior Manager, CT Clinical Science Toshiba America Medical Systems, Inc.

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Current status of diagnostic imaging in dental university hospitals in Japan

Preparing for Medical Physics Components of the ABR Core Examination

Accounting for Imaging Dose

A Snapshot on Nuclear Cardiac Imaging

With increasing use of computed tomography (CT) in modern medicine, concerns have arisen regarding increasing radiation dose to the community from med

Radiation Dose in X-Ray and CT Exams

Outline. NCRP Scientific Committee 6-2

RADIATION SAFETY. Junior Radiology Course

Translating Protocols Across Patient Size: Babies to Bariatric

EXPERIMENTAL AND THERAPEUTIC MEDICINE 9: , 2015

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

Comparison of 64 slice multi detector CT vs 128 slice multi detector CT for acute chest pain evaluation in the chest pain unit

Justification of the use of CT for individual health assessment of asymptomatic people: the Chinese experience

Purpose. Methods and Materials

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

Radiation Units and Dosimetry 15 August Kalpana M. Kanal, Ph.D., DABR 1

Ionizing Radiation Exposure from Radiologic Imaging: The Issue and What Can We Do?

Cancer Risks from CT Scans: Now We Have Data What Next?

The radiation dose in retrospective

Optimization of kvp and mas for Pediatric Low-Dose Simulated Abdominal CT: Is It Best to Base Parameter Selection on Object Circumference?

CT Imaging at the Point-of-Care

Medical Physicists Bring New Value to Patient-Centered Care

CT Dose Optimization for Whole- Body PET/CT Examinations

Ask EuroSafe Imaging Tips & Tricks. CT Working Group. On the use of Diagnostic Reference Levels in CT

7/31/2017. Image Gently is. The Pediatric Radiologist Tailoring CT Protocols to the Patient's Age, Size, and Clinical Scenario.

CT Low Dose Lung Cancer Screening. Part I. Journey to LDCT LCS Program

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Radiation dose reduction in computed tomography: techniques and future perspective

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Commentary ISSUES TO BE CONSIDERED

Ultralow Dose Chest CT with MBIR

Why radiation protection matters?

MDCT and Obesity. Introduction. Incidence of Obesity. Definition of Obesity. Raul N. Uppot

Radiation Safety For Anesthesiologists. R2 Pinyada Pisutchareonpong R2 Nawaporn Sateantantikul Supervised by Aj Chaowanan Khamtuicrua

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

BODY TOMOSYNTHESIS A. INTRODUCTION/CURRENT PRACTICE. Conventional radiography (X-ray)

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

X-Ray & CT Physics / Clinical CT

Combined Anatomical and Functional Imaging with Revolution * CT

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

MEDICAL IMAGING MEDICAL IMAGING MEDICAL IMAGING

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)

Medical Diagnostic Imaging

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

Electronic collimation and radiation protection in paediatric digital radiography: revival of the silver lining

Session 83X Dose Management: Patient and Staff Radiation Safety in Radiology

Radiology. General radiology department. X-ray

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Positron Emission Tomography Computed Tomography (PET/CT)

8/1/2017. Financial Disclosures. Dose Tracking at MGH. How Dose Tracking Affected Protocol Optimization in a Tertiary Quaternary Healthcare Center

Estimating Risks from CT Scans - in the Context of CT Scan Benefits

Transcription:

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology Minimizing CT Radiation Dose CT examinations improve health care and are an essential part of diagnosis and treatment planning Radiation exposure from CT is higher (2-15 msv) than plain film radiography (0.05-2 msv) No direct data have shown that CT examinations are associated with an increased risk of cancer; extrapolations from studies of radiation exposure suggest there is a very small incremental risk The risk for pediatric patients is likely to be greater than that for adults, dedicated CT protocols are in place at MGH to minimize their exposure Other strategies for minimizing radiation dose from CT include avoiding unnecessary CT examinations, utilizing alternate imaging modalities when appropriate, and using state-of-the-art CT dose reduction technologies The fine anatomical detail visible in computed tomography (CT) images has revolutionized diagnosis of both acute and chronic diseases and often provides information critical to the management and planning of treatment for both adults and children. As technological advances have increased, the range of examinations CT utilization has steadily increased and has recently been reported to be as high as 17% of the total radiology workload. However, the x-ray exposure from each CT scan is substantially higher (2-15 msv) than plain film radiography (0.05-2 msv) and, therefore, CT accounts for about 70-75% of the total ionizing radiation from diagnostic imaging. While these levels of radiation are well below those that cause deterministic effects (for example, cell death), there is concern that they may be associated with a risk of stochastic effects (such as cancer), albeit small. No direct study has shown that CT increases the risk of cancer. Radiation scientists extrapolate the risks of x- ray radiation encountered during CT examinations from studies of the long-term outcome of people exposed to the atomic explosions in Japan and workers in the nuclear industry. According to these extrapolations, the projected lifetime risk of developing cancer from a single CT examination is one in 1,000-2,000 per 10 msv. It should be noted that this projected risk is very small compared to the overall lifetime risk of developing cancer, which is about one in three. Furthermore, the majority of patients who receive CT scans already have cancer and/or life span limiting conditions. Nevertheless, there is an incremental risk with each additional scan and with higher radiation doses and, considering the large numbers of patients who receive CT examinations, a small individual risk translates into a larger risk from the public health Table 1. Scanning Parameters that Affect Radiation Dose Tube current (ma) Tube potential (kvp) Gantry rotation time Range of scan (length of body region scanned) Pitch (slice overlap), table speed, and detector configuration Number of image acquisition phases perspective. In addition, there is greater concern for pediatric patients and pregnant women both because children and fetuses are more vulnerable to radiation and because they have more years to live. These potential risks must be weighed against the benefits of the CT examination. (For more information on radiation risks in pregnancy, see the February 2004 issue of Radiology Rounds). Even though the radiation exposure from a CT scan carries, at most, a very small risk of developing cancer, it is prudent to minimize patients exposure to radiation. Recognizing this, radiologists have adopted the principle of as low as reasonably achievable (ALARA) and manufacturers have been pro-active in developing dose reduction techniques. In CT scanning, a number of different parameters can be adjusted that affect radiation dose (Table 1) and several strategies are in use at MGH to minimize radiation dose while maintaining diagnostic quality (Table 2). In addition, the MGH continually explores new ways to achieve lower radiation exposure consistent with acceptable diagnostic image quality.

Figure 1. Abdomen and pelvic CT of a 15 year-old girl who had a perforated appendix. A. CT scan performed using standard setting (radiation dose, 10.9 mgy) B. A follow-up CT scan was performed 8 days later using pediatric dose reduction settings (radiation dose, 4.8 mgy). B is noisier than A but still of diagnostic quality. Scans show resolving inflammatory changes and a pigtail drainage catheter (solid arrows) with an appendicolith (dotted arrows) in the mid abdomen. Avoiding Unnecessary CT Scans There are several clinical scenarios in which unnecessary CT examinations may be performed, including cases in which CT is not the most suitable imaging modality for the presenting symptoms, duplicate examinations are ordered because of poor communication, the radiological findings are unlikely to affect treatment decisions, or follow-up examinations are not clinically justified. Computerized Radiology Order Entry (ROE) with decision support informs the referring physician if the CT examination is not likely to be diagnostic, given the symptoms entered in the system, and suggests alternate imaging examinations. At the MGH, this strategy has decreased low yield CT examinations from 6% to 2% and has increased the percentage of CT examinations that have yielded clinically important findings. In some cases, such as in situations where a patient is transferred from the care of one physician to another, a duplicate CT scan may be ordered unknowingly. If the order is made on ROE, there is an automatic alert if the patient has had a recent CT examination. If the order is made by other means, it is routine practice at MGH to check for prior radiology examinations and, if the new order is a repeat examination (not a follow up examination), a radiologist will contact the referring physician to confirm that a second scan is warranted. Pediatric CT Every request for a pediatric CT examination is prescreened by a radiologist. If there is any doubt as to the appropriateness of the examination in any patient, radiologists may discuss alternatives with the referring physician. Smaller patients require less radiation for the same image quality. For this reason, weighing machines are in place in most CT examination rooms at the MGH and scanning parameters, including both ma and kvp, are set according to the patient s height and weight, the clinical indication for the scan, and the number of previous scans for this indication. Implementation of this strategy to minimize radiation dose for pediatric patients while ensuring diagnostic image quality is aided by color-coded posters and memory cards, which have been developed to help the radiologists and technologists identify the lowest radiation dose and most suitable technique to answer specific problems on an individual patient basis. As a result of these adjustments in protocol, pediatric patients are exposed to 44-70% less radiation than if standard settings were used (Figure 1). When patients have had a previous scan for the same clinical indication, it is often possible to reduce the radiation dose. For example, if a second scan is performed for renal stones, it is possible to reduce the radiation dose by 50% and still obtain diagnostic information because of the high attenuation of renal stones. Radiation exposure in subsequent scans may be cut down even further. However, if the image contrast is expected to be low, as in lesions in the liver, it may not be possible to lower the radiation dose in follow-up scans. Automatic Exposure Control For most adult CT examinations, automatic exposure control techniques are used rather than manual adjustment of ma and kvp. Automatic exposure control software, installed on all CT scanners at MGH, automatically adapts radiation dose to patient size, including anatomical variation within the patient, while maintaining a specified level of image noise (Figure 2). Use of automated exposure control in, for example, the abdomen and pelvis in adult patients has been shown to decrease exposure by an average of 43%. The decreases are greater than average in slim patients; the radiation dose in obese patients may be higher but result in better image quality than if standard fixed current settings are used. 2

Figure 2. Automatic Exposure Control for CT examinations. The attenuation through one region of the body, A, is less than another, B, and is less in the anterior-posterior projection than the lateral. With automatic exposure control, the average x-ray tube current is lower at A than in B. In both A and B, the tube current is lower in the anterior-posterior projection than in the lateral projection. Table 2. Strategies for Minimizing Radiation Dose Eliminate inappropriate CT examinations Avoid duplicate examinations Perform follow-up scans only when clinically justified and limit to area of pathological findings Use dedicated protocol chart for pediatric patients that optimizes dose to age, size, and clinical indications Optimize radiation dose to patient size and clinical indications in adults patients with automated tube modulation Use EKG gating to minimize dose during coronary CT angiography Coronary CT Angiography Without dose reduction techniques, coronary CT angiography requires a relatively high radiation exposure because images of the coronary arteries are acquired in multiple phases of the cardiac cycle. In order to minimize the dose while maintaining image quality, a physician technologist team tailors both the kvp and ma to each patient in order to optimize the risk: benefit ratio. In addition, when the heart rate is low and steady, ECG-gating is used to modulate the current, lowering the current to 4-25% of the nominal value during the systolic phase, which allows to reconstruct high quality images of the coronary arteries in one phase at the cost of noisier images at other phases (Figure 3). Quality Control The Department employs a certified medical physicist, who ensures proper calibration and quality control of all CT scan systems. All MGH Radiology technologists and staff are educated on the potential risks involved in radiation exposure from CT imaging. Additionally, MGH CT protocols and practices meet the American College of Radiology (ACR) Practice Guidelines and Technical Standards, which are evidence-based guidelines to assist medical providers in the safe and appropriate use of diagnostic imaging (including CT). Using our customized scanning approaches, radiation dose reduction can be achieved without compromising image quality and therefore interpretation accuracy is not impacted by the lower amounts of radiation used with optimized protocols. The Department also employs a lock-in security system for its scanners whereby only designated radiologists and/or CT operation managers can set the scanning techniques in order to maintain consistent scanning techniques and minimize possibility of higher than required radiation dose. 3

Figure 3. ECG-Gated Cardiac CT Angiography. A. The x-ray tube current is lowered prospectively during part of the cardiac cycle and increased during the phase at which the heart has least motion. High signal-to-noise images (B), reconstructed from the data acquired at standard tube current, show detailed anatomy including the coronary arteries (arrows). Images with lower signal-to-noise (C) are reconstructed from data acquired at low tube current. Scheduling Radiology examinations may be ordered online via the Radiology Order Entry (http://mghroe) or by telephone 617-724-XRAY (9729) for all locations. CT is performed at the main campus as well as Mass General West Imaging, Waltham and Mass General Imaging, Chelsea. Further Information An informational handout suitable for patients who have concerns about radiation dose is available on the Department of Radiology, CT Division website. CT Scans and Radiation Risk. For further questions, please contact Hani H. Abujudeh, M.D., Director of Quality Assurance, MGH Department of Radiology at 617-726-8366 or Dushyant Sahani, M.D., Director of CT, MGH Department of Radiology at 617-726-3937. We would like to thank radiologists Hani H. Abujudeh, M.D., Dushyant Sahani, M.D., Suhny Abbara, M.D., Manudeep Kalra, M.D., Sjirk Westra, M.D., medical physicist Bob Liu, Ph.D., and CT Operations Manager Joseph Fay, from the MGH Department of Radiology, for their assistance and advice for this issue. 4

References Amis, ES, Butler, PF, Applegate, KE, Birnbaum, SB, Brateman, LF, Hevezi, JM, Mettler, FA, Morin, RL, Pentecost, MJ, Smith, GS, Strauss, KJ and Zeman, RK. (2007) American College of Radiology White Paper on Radiation Dose in Medicine. J Am Coll Radiol 4: 272-284 Frush, DP and Applegate, K. (2004) Computed tomography and radiation: understanding the issues. J Am Coll Radiol 1: 113-9 Paterson, A and Frush, DP. (2007) Dose reduction in paediatric MDCT: general principles. Clin Radiol 62: 507-17 Paul, JF and Abada, HT. (2007) Strategies for reduction of radiation dose in cardiac multislice CT. Eur Radiol 17: 2028-37 Rizzo, S, Kalra, M, Schmidt, B, Dalal, T, Suess, C, Flohr, T, Blake, M and Saini, S. (2006) Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. AJR Am J Roentgenol 186: 673-9 Semelka, RC, Armao, DM, Elias, J, Jr. and Huda, W. (2007) Imaging strategies to reduce the risk of radiation in CT studies, including selective substitution with MRI. J Magn Reson Imaging 25: 900-9 2008 MGH Department of Radiology Janet Cochrane Miller, D. Phil., Author Raul N. Uppot, M.D., Editor 5