Depth of Central Venous Catheterization by Intracardiac ECG in Paediatric Patients

Similar documents
JMSCR Vol 05 Issue 10 Page October 2017

Research Article Can we predict the Position of Central Venous Catheter Tip Following Cannulation of Internal Jugular Vein?

Optimal positioning of right-sided internal jugular venous catheters: Comparison of intra-atrial electrocardiography versus Peres formula

Comparison of the bedside central venous catheter placement techniques: landmark vs electrocardiogram guidance

External Jugular Vein Catheterization Using Intra-Atrial Electrocardiogram

You have a what, inside you?

You have a what, inside you?

Peripherally Inserted Central Catheter & Midline Placement with ECG Confirmation of Tip Placement

TITLE: Electrocardiograms versus X-rays for Guided Placement of Central Venous Catheter Tips: A Review of Clinical and Cost-effectiveness

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

CATHETER MALPOSITION FOLLOWING SUPRACLAVICULAR APPROACH FOR SUBCLAVIAN VEIN CATHETERISATION

Correlation of Surface Landmarks Based Insertion Length of Right Subclavian Central Venous Catheter with Post Insertion Location of Catheter Tip

Peel-Apart Percutaneous Introducer Kits for

Caroline Polley, BSN, RN, VA-BC Clinical Specialist BD

Simple Formula to Place Central Venous Catheter Tip at T6 After Surgical Cutdown in Neonates

Comparison Between Novel Tip Positioning Technology using ECG and Doppler and 2-D Echocardiography for the Placement of Central Catheters

Mary Lou Garey MSN EMT-P MedFlight of Ohio

The use of ultrasound during and after central venous catheter insertion versus conventional chest X-ray after insertion of a central venous catheter

Advocate Christ Medical Center CVC Placement Certification Course

Central Venous Access Devices. Stephanie Cunningham Amy Waters

Girish M Nair, Seeger Shen, Pablo B Nery, Calum J Redpath, David H Birnie

Hydrocephalus: Electrocardiographic Localization of

Lines and tubes. 1 Nasogastric tubes Endotracheal tubes Central lines Permanent pacemakers Chest drains...

Figure 2. Normal ECG tracing. Table 1.

Dr. prakruthi Dept. of anaesthesiology, Rrmch, bangalore

Ultrasound-guided infraclavicular axillary vein cannulation for central venous access {

Ultrasound Guided Vascular Access. 7/25/2016

Kadlec Regional Medical Center Cardiac Electrophysiology

Interesting Cases - A Case Report: Renal Cell Carcinoma With Tumor Mass In IVC And Heart. O Wenker, L Chaloupka, R Joswiak, D Thakar, C Wood, G Walsh

The carina as a radiological landmark for central venous catheter tip position

Health Science 20 Circulatory System Notes

REVIEWED/REVISED 12/12 DATE) MEDICAL STAFF (if applicable) DATE OTHER DATE Special Procedures Committee 10/12 Nursing Leadership Team 08/12

Over the Wire Technique vs. Modified Seldinger Technique in Insertion of PICC

Kristin Wise, MD, FHM Division of General Internal Medicine and Geriatrics Hospital Medicine 2013

Ahsan Mustafa, Khaja Ali Hassan and Syed Abdur Rahman. Department of Anaesthesiology, Deccan College of Medical Sciences, Hyderabad, India

Persistent left superior vena cava with absent right superior vena cava detected during emergent coronary artery bypass grafting surgery

Transjugular liver access and biopsy

Understanding Atrial Fibrillation A guide for patients

The Mammalian Circulatory System

Transvenous Pacemaker Implantation 22 years after the Mustard Procedure

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

This presentation will deal with the basics of ECG description as well as the physiological basics of

4. The two inferior chambers of the heart are known as the atria. the superior and inferior vena cava, which empty into the left atrium.

Central Line Care and Management

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2

Min Hur, Eun-Hee Kim, In-Kyung Song, Ji-Hyun Lee, Hee-Soo Kim, and Jin Tae Kim INTRODUCTION. Clinical Research

Pediatric pacemakers & ICDs:

The Adolescent and Adult Congenital Heart Disease Program

Original Article Bedside prediction of peripherally inserted central catheter length: based on patient height combined with surface landmark

Children s Acute Transport Service

PICC, port e trombosi cateterecorrelata: la prevenzione è legata alla tecnica di impianto!

Supplementary Online Content

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Spontaneous Migration of a Central Line Catheter into the Heart. Saeed Al Hindi, MD, CABS, FRCSI* Khulood Al-Saad, MD**

Clinical Data Summary: Avoid FFS Study

Central Vascular Catheter Placement Evaluation Using Saline Flush and Bedside Echocardiography

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Tip navigation and tip location for PICCs. Mauro Pittiruti Catholic University, Rome - Italy

Implications of Precise PICC Tip Location: The New Gold Standard in Clinical Practice?

MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation

PARENTERAL NUTRITION: VASCUAR ACCESS DEVICE SELECTION

Electrocardiogram ECG. Hilal Al Saffar FRCP FACC College of medicine,baghdad University

Groshong* PICC and Catheters

anatomic relationship between the internal jugular vein and the carotid artery in children after laryngeal mask insertion. An ultrasonographic study.

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Gamma3 TM Fragment Control Clip

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

UNDERSTANDING ELECTROPHYSIOLOGY STUDIES

Research Article Comparison of Ultrasound Guided Radial Artery Cannulation with Conventional Palpation Technique

The University of Toledo Medical Center and its Medical Staff

About atrial fibrillation (AFib) Atrial Fibrillation (AFib) What is AFib? What s the danger? Who gets AFib?

Diploma in Electrocardiography

Electrocardiography for Healthcare Professionals

BACHELOR OF SCIENCE IN CARDIO VASCULAR TECHNOLOGY

Pearson's Comprehensive Medical Assisting Administrative and Clinical Competencies

Finally, a pacemaker may be either permanent or temporary, which will also factor into your code selections.

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

Understanding Atrial Fibrillation

Is finder needle necessary for internal jugular vein catheterization?

Central Venous Line Insertion

A novel suture-traction method for right internal jugular vein catheterization in left-lateral position in anesthetized patients.

Cardiovascular System Notes: Heart Disease & Disorders

Interesting ECG Right bundle branch block pattern during right ventricular permanent pacing: Is it safe or not?

CORONARY ARTERIES HEART

Case #1. Case #1- Possible codes. Unraveling the -59 modifier. Principles of Interventional. CASE 1: Simple angioplasty

Positive Results with a New Screw-in Electrode with Isolated Screw and Fractal Coating of the Ring: the RETROX Electrode in the Atrial Position

Implantation of a Permanent Tined Endocardial Electrode into Right Atrium during Open-heart Surgery: Report of 3 Cases

Overview of CVADs. Type of device commonly used. Dwell time Flushing requirement Associated complications. lumens

Prevention of thrombosis

A PATIENT S GUIDE TO THE LEFT ATRIAL APPENDAGE CLOSURE. Reducing the risk of stroke in atrial fibrillation

Research Article Predictions of the Length of Lumbar Puncture Needles

Ultrasound-Guided Infraclavicular Axillary Vein Cannulation

Question Expected Answers Marks Additional Guidance two marks for correct answer 1 (a) a single value between 67 and 80 ; ; max 2

Transcription:

Original Article Elmer Press Depth of Central Venous Catheterization by Intracardiac ECG in Paediatric Patients Prerana N. Shah a, b, Jithesh Appukutty a, Deepa Kane a Abstract Background: Central venous catheterization is a frequent procedure in cardiac surgery and intensive care setting. Its faulty positioning can cause severe complications, which can be fatal and erroneous central venous pressure measurement. Methods: In this prospective study, the right internal jugular vein (IJV) was cannulated in cardiac surgery patients over a period of four months and catheter tip positioning was guided by means of intracardiac ECG. The insertion depth was registered at the position of maximum P-wave amplitude and the catheter was fixed after withdrawing a further two cm. Pearson s correlation coefficient was calculated to categorize any relation between height, body weight or body surface area (BSA) and the depth of insertion required to locate correct positioning. Plots of distance versus patient s height were made, and regression lines and equations were calculated. Bland-Altman analysis of data was done to compare the old formulae with our derived formulae. 155 adult patients were studied. Results: Distances measured were found to be highly correlating with patient s height, followed by body surface area (BSA) and weight. For right IJV cannulation in valvular surgeries in adults, the depth of insertion (cm) was (Height in cm / 15) + 2 and in nonvalvular surgeries in adults, it was (Height in cm / 15) + 1.4. Conclusions: The devised formulae accurately predicted the required depth of catheters thereby reducing the possibility of complications and need for radiographic confirmation. Introduction Placement of a central venous catheter or central venous catheterization (CVC) is a frequent procedure during cardiac anaesthesia and intensive care. Its malposition can cause faulty and erroneous central venous pressure measurement along with several fatal complications such as thrombosis of the great vessels, arrhythmias, cardiac perforation and cardiac tamponade. To avoid these fatal complications, the CVC is recommended to be placed in the distal superior vena cava (SVC) i.e., outside of the cardiac chamber. Malposition related complications could be serious. Thus, to suggest a guideline for the proper length of a CVC inserted through the internal jugular vein (IJV), we measured the distance from the skin puncture site to the SVC-right atrium (RA) junction by using intracardiac lead ECG monitoring. The formulae available for the depth in pediatric patients as by Andropoulos is that when height of the patient up to height (H) of 100 cm, the formula is H/10-1, and when the height is more than 100 cm it is H/10-2 [1]. However, we did not get at those values. Hence, the need for the study was decided over a period of four months so that after the analysis of our data, we could co-relate and decide whether the available formulae were acceptable. The aim of our study was to study the average depth of insertion of central venous catheter and to try to formulate a general guideline for depth of CVC through the right IJV. Keywords: Heart; Catheterization; Monitoring; Intracardiac electrocardiography; Veins; Jugular Manuscript accepted for publication September 1, 2011 a Department of Anaesthesiology, Seth GSMC & KEM Hospital, Parel, Mumbai 400012, India b Corresponding author: Prerana N. Shah. 73 B, Varma Villa, Vitthalbhai Road, Vile Parle West, Mumbai 400056, Maharashtra, India. Email: pps@kem.edu doi:10.4021/ijcp17e Methods Ethical approval for this study was taken. A valid informed consent was obtained. The patients up to 12 years of age were selected according to the inclusion criteria, those undergoing cardiac surgery and requiring central venous catheterization and the exclusion criteria being consent refusal or any abnormal ECG rhythm respectively. The technique used for CVC was the Seldinger technique in all patients. Constant and standard approach used for IJV catheterization was anterior approach (skin puncture at the apex of the triangle formed by the two heads of sternocleidomastoid muscle). CVC was 70 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited

Shah et al Table 1. Demographic Data Male Female Total Paediatric Height < 100 28 16 44 Height > 100 19 6 25 Total 47 22 69 performed after the induction of general anesthesia using standard institutional protocol for general anaesthesia. The CVC set included the standard multi lumen central venous catheter and a connection cable with a clip for connecting the guide wire to Certodyn universal adaptor (B. Braun, Melsungen, Germany). Once the IJV was identified, the sterile connection cable was clamped to the guide wire in order to connect it to the Certodyn universal adaptor, which allowed the operator to switch from a surface to an intracardiac ECG, the guide wire acting as a unipolar electrode by using a switch. The CVC was advanced together with the guide wire until the rise in P wave amplitude remained the same. The lead cable coming from the monitor has to be fixed to the Universal adaptor, which has a cable with clamp and has to be fixed to the red skin electrode. During advancement of the catheter with guide wire, the disposable lead cable has to be clamped to the wire and the Universal adaptor. Depth of insertion can be known from the markings on the catheter. The guide wire was removed and the central venous catheter was withdrawn by 2 cm. The catheter was then fixed to the skin. Intraoperatively, the position of the tip of central venous catheter was confirmed by the operating surgeon, either by palpation of the tip or by visualization when right atrium was opened. All data were tabulated and analyzed systematically. The patients, were divided according to the height (H) into two groups of < 100 cm and > 100 cm. All data were expressed as Mean ± SD. The demographic data were analyzed using Chi square test. A P-value < 0.05 was considered significant. Pearson s correlation coefficient was calculated to categorize any relation between height, weight or body surface area (BSA) and the depth of insertion required to locate correct positioning of central venous catheter. Plots of Table 2. Depth of Central venous catheterization Weight (kg) Height (cm) BSA Depth (cm) Mean ± SD 7.34 ± 3.29 72.08 ± 13.75 0.38 ± 0.12 6.0 ± 1.1 Height < 100 N = 44 R 0.37* 0.51** 0.45* Significance 0.021 0.001 0.017 Range 3-19 49-97 0.2-0.64 Mean ± SD 17.56 ± 6.99 115.92 ± 13.96 0.75 ± 0.19 7.52 ± 1.64 Height > 100 N = 25 R 0.70** 0.54** 0.63** Significance 0.000 0.008 0.001 Range 12-46 100-151 0.5-1.41 ** Correlation is significant at 0.01 level (2-tailed) * Correlation is significant at 0.05 level (2-tailed) r Pearson correlation coefficient of Depth with Weight, Height and BSA 71

Depth of Central Venous Catheterization Figure 1. Depth versus height in Paediatric < 100 cm (r 2 = 0.270 P = 0.001) distance were made and regression lines and equations were calculated by using SPSS 14.0 (SPSS, Chicago, IL). Blant- Altman analysis of data was done to compare the old existing formulae with our derived formulae. Results A total of 69 patients were included in the study. There was no significant gender based differences among different groups (P = 0.087) (Table 1). As height had significant correlation at 0.05 level, further analysis was restricted to height (Table 2). Simple formulae were developed to predict placement of CVC through the right IJV. These were developed by plotting a straight line on the graph of patient s height versus depth and then deriving a simple formula describing that line. (Fig. 1, 2) For right IJV cannulation: Paediatric patients < 100 cm: Depth of insertion (cm) = (Height in cm/25) + 2.5 Figure 2. Bland Altman for paediatric < 100 cm group 72

Shah et al Figure 3. Depth versus height in Paediatric > 100cm Paediatric patients > 100 cm: Depth of insertion (cm) = (Height in cm/10) 4 After applying Blant Altman (Fig. 3, 4) for the data in paediatric patients > 100cm, the bias i.e. average difference between the two sets of readings) was very small with new formula (-0.072; the depth measured with new formula was 0.07 cm more as compared with existing) as compared with existing formula (bias was -2.07; the formula measures 2.07 cm more than existing). Similarly, the width of 95% Confidence interval with new formula was less as compared with the width of 95% Confidence interval with existing formula. However, in paediatric patients < 100 cm group, the bias was small with existing formula (-0.16; the depth measured with existing formula is 0.16 cm more as compared with original) as compared with new formula (bias is 0.66; the formula measures 0.66 cm less than existing). Similarly, the width of 95% Confidence interval with new formula is less as compared with the width of 95% CI with existing formula. Discussion The CVC is recommended to be placed in the distal superior vena cava (SVC) i.e., outside of the cardiac chamber. Figure 4. Bland Altman for paediatric > 100 cm group 73

Depth of Central Venous Catheterization Incorrect positioning in the RA or ventricle and misplacement in the lateral branches of the superior vena cava are the most common types of catheter misplacement. They can be avoided by correctly judging catheter length, using a gentle technique when advancing the catheter and positioning the patient in a way that facilitates access to the vein. Studies conducted over the past several years have proven that the use of an intracardiac ECG may obviate the need for routine x-rays to verify CVC placement. In 1949, Hellerstein took his previous experience with ECG leads and applied them in a unique way for directly recording atrial potentials Hellerstein s method differed from that of his colleagues who used metal wires for recording the signals, whilst he used a CVC filled with saline solution. The signal was captured at the catheter hub through a self-made adaptor and transferred to an ECG monitor. In his landmark publication, he examined the recording of both the saline solution and through a metal wire. As soon as the catheter tip reaches the sinoatrial node, there is an abrupt increase in height of the P wave [1, 2]. When the tip enters into the RA, a height of the P wave potential is reached. The intracardiac ECG should be recorded when the wire and catheter are in this position. A disposable electrode cable is available in the catheter sets, so that the signal can be recorded directly from the metallic guide wire. This electrode cable is connected to a universal adaptor that allows the user to continuously switch back and forth between skin and intra-arterial lead. An electrical switching device for alternating between the skin lead and intracardiac lead is required for both the electrolyte-filled and stylet guided lead connected. Each set contains a disposable lead cable with alligator clip, which can be attached to the free end of the wire. Both the stylet and the Seldinger wire conduct the potential from the atrium and onwards through the lead cable to the ECG monitor without risk of interference. Recording the atrial ECG through the metallic guide stylet greatly simplifies handling, since all the components are present in sterile versions and are easy to connect. A maximum P-wave is derived even at the entrance to the right atrium. This explains why ECG guided CVC placement based on the largest P wave amplitude consistently resulted in correct positioning of the CVC tip at the transition from the superior vena cava to the right atrium. The intracardiac ECG lead produces clear and reliable information about catheter tip position for all but patients with pre-existing abnormal cardiac rhythms. Numerous clinical studies have demonstrated a high accuracy rate of over 90% for this control method. However, in our experience, the distance did not correspond according to any of the published formulae like right subclavian or jugular vein: 13-16 cm Left subclavian or jugular vein: 15-20 cm [3]. Peres and coworkers published catheterization guidelines for adult patients [4] and the working group of Andropoulos designed a formula for predicting correct CVC positioning in paediatric patients [1]. Peres devised the formula for access through the subclavian and jugular vein, while there was insufficient data available for other puncture sites. According to Peres, through Right side: External and internal jugular vein: depth is H/10 [4]. Andropoulos and coworkers performed a similar study in children and juveniles, but considered only access through the right subclavian and internal jugular vein. When H = 100 cm, it is H/10-1 and when H > 100 cm, it is H/10-2 [1]. The values obtained using the Andropoulos formula contradicts those of the Peres formula in patients taller than 100 cm and when access through the jugular vein is used. This discrepancy merits further investigation. Hence, our study was designed over a period of four months to decide on the formulae to be used for daily use. In patients with dysrhythmia, atrial fibrillation or implanted pacemakers, the P wave remains unchanged in the intra-arterial ECG lead; even if the catheter is correctly withdrawn from the atrium into the vena cava [5]. There is only one single report of catheterization of the carotid artery with advancement into the right atrium, which resulted in the induction of P wave elevation. In this case, the ECG signal was interpreted as confirming correct placement although the catheter had been seriously misplaced [6]. Obligatory radiographic monitoring does not produce a clinical advantage, whereas it does increase costs unnecessarily. Constant position monitoring is required to instantly identify problems that might arise during puncture or advancement. The atrial ECG recording is therefore recommendable not only for economical reasons, but because of its high success rate [7]. The use of intracardiac ECG is a reliable, easy to learn method and can be conducted at minimal cost. The use of the ECG lead to verify CVC position has now become a standard technique in anaesthesia and intensive care medicine [8]. Physicians who have mastered this technique therefore no longer need to perform chest x-rays to monitor catheter position, since the ECG lead provides sufficiently accurate verification [8]. Routine chest x-ray after catheter placement is thereby obviated. Our formulae gave better precision as compared to previous formulae. Although this easy method is available since long, it is not utilized optimally. Conclusion The devised formulae can accurately predict the required depth of catheters, thereby possibly reduce the possibility of complications and need for radiographic confirmation. Acknowledgements Assistance with the study: None except the authors. Financial Support and Sponsorship None. 74

Shah et al Conflict of Interest None. References 1. Andropoulos DB, Bent ST, Skjonsby B, Stayer SA. The optimal length of insertion of central venous catheters for pediatric patients. Anesth Analg. 2001;93(4):883-886. 2. Hellerstein HK, Pritchard WH, Lewis RL. Recording of intracavity potentials through a single lumen, saline filled cardiac catheter. Proc Soc Exp Biol Med. 1949;71(1):58-60. 3. Kirby, R. R. et al.: Clinical Anesthesia Practice. 2nd: 531-540W. B. Saunders Philadelphia 2002, 2 4. Peres PW. Positioning central venous catheters--a prospective survey. Anaesth Intensive Care. 1990;18(4):536-539. 5. Salmela L, Aromaa U. Verification of the position of a central venous catheter by intra-atrial ECG. When does this method fail? Acta Anaesthesiol Scand. 1993;37(1):26-28. 6. Schafer M, Ciesielski K, Kuss B, Link J. [Incorrect placement of a vena cava catheter and its prevention by intra-atrial ECG]. Anaesthesist. 1988;37(1):49-51. 7. Schuster M, Panning B. Electrocardiographic guidance in placing central venous catheters. Crit Care Med. 2000;28(10):3577-3578. 8. WeiBlauer, W.: Der Cava-Katheter aus medico-legaler Sicht. Anaesthesiol. Intensivmed. Notfallmed. Schmerzther. 1998, 33: 117-118 75