Suitability of New Methods for Pulseoximetric Data Analysis in Screening Diagnostics of Respiratory Disorders During Sleep (RDDS)

Similar documents
(To be filled by the treating physician)

In 1994, the American Sleep Disorders Association

Arousal detection in sleep

Pulse Oximetry Test: Summary Report

Introducing the WatchPAT 200 # 1 Home Sleep Study Device

11/20/2015. Eighth Bi-Annual Pediatric Sleep Medicine Conference. November 12-15, 2015 Omni Amelia Island Plantation Resort Amelia Island, Florida

TABLE OF CONTENTS. Physician's Manual. I. Device Description 2. II. Intended Use 5. III. Contraindications 5. IV. Warnings and Precautions 5

Policy Specific Section: October 1, 2010 January 21, 2013

Edoardo Gronda UO cardiologia e Ricerca Dipartimento Cardiovascolare IRCCS MultiMedica

The Familial Occurrence of Obstructive Sleep Apnoea Syndrome (OSAS)

The Latest Technology from CareFusion

PEDIATRIC SLEEP GUIDELINES Version 1.0; Effective

SLEEP DISORDERED BREATHING The Clinical Conditions

POLICY All patients will be assessed for risk factors associated with OSA prior to any surgical procedures.

DECLARATION OF CONFLICT OF INTEREST

Polysomnography (PSG) (Sleep Studies), Sleep Center

Σύνδρομο σπνικής άπνοιας. Ποιός o ρόλος ηοσ ζηη γένεζη και ανηιμεηώπιζη ηων αρρσθμιών;

BiPAPS/TVAPSCPAPASV???? Lori Davis, B.Sc., R.C.P.T.(P), RPSGT

Sleep and Neuromuscular Disease. Sharon De Cruz, MD Tisha Wang, MD

Monitoring: gas exchange, poly(somno)graphy or device in-built software?

Obstructive sleep apnoea How to identify?

Hilbert Huang analysis of the breathing sounds of obstructive sleep apnea patients and normal subjects during wakefulness.

Pain Module. Opioid-RelatedRespiratory Depression (ORRD)

Non-contact Screening System with Two Microwave Radars in the Diagnosis of Sleep Apnea-Hypopnea Syndrome

OSA and COPD: What happens when the two OVERLAP?

The most accurate predictors of arterial hypertension in patients with Obstructive Sleep Apnea Syndrome

International Journal of Scientific & Engineering Research Volume 9, Issue 1, January ISSN

A Deadly Combination: Central Sleep Apnea & Heart Failure

General Outline. General Outline. Pathogenesis of Metabolic Dysfunction in Sleep Apnea: The Role of Sleep Fragmentation and Intermittent Hypoxemia

Dental Sleep Medicine Basics

A Sleeping Monitor for Snoring Detection

Treatment-related changes in sleep apnea syndrome in patients with acromegaly: a prospective study

Julie Zimmerman, MSN, RN, CCRN Clinical Nurse Specialist

Prediction of sleep-disordered breathing by unattended overnight oximetry

The use of overnight pulse oximetry for obstructive sleep apnoea in a resource poor setting in Sri Lanka

6/5/2017. Mellar P Davis MD FCCP FAAHPM Geisinger Medical Center Danville, PA

Pain patient with sleep-disordered breathing

Brian Palmer, D.D.S, Kansas City, Missouri, USA. April, 2001

ALCO Regulations. Protocol pg. 47

A 74-year-old man with severe ischemic cardiomyopathy and atrial fibrillation

Development of OSA Event Detection Using Threshold Based Automatic Classification

IJOART. A New Approach for The Prediction of Obstructive Sleep Apnea Using a Designed Device ABSTRACT 1 INTRODUCTION

In-Patient Sleep Testing/Management Boaz Markewitz, MD

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

Development of a portable device for home monitoring of. snoring. Abstract

The clinical trial information provided in this public disclosure synopsis is supplied for informational purposes only.

VPAP Auto Positive Airway Pressure Device Data Management Guide English

Transcutaneous Monitoring and Case Studies

Κλινικό Φροντιστήριο Αναγνώριση και καταγραφή αναπνευστικών επεισοδίων Λυκούργος Κολιλέκας Επιμελητής A ΕΣΥ 7η Πνευμονολογική Κλινική ΝΝΘΑ Η ΣΩΤΗΡΙΑ

RESPIRATION AND SLEEP AT HIGH ALTITUDE

About VirtuOx. Was marketed exclusively by Phillips Healthcare division, Respironics for 3 years

The Ignored Parameter in the Diagnosis of Obstructive Sleep Apnea Syndrome: The Oxygen Desaturation Index

Sleep Studies: Attended Polysomnography and Portable Polysomnography Tests, Multiple Sleep Latency Testing and Maintenance of Wakefulness Testing

ResScan Report Interpretation Guide. FOR CLINICAL USE ONLY V1.0 June, 2011

Case Report Resolution of Periodic Breathing in a Child with Idiopathic Pulmonary Arterial Hypertension

Auto Servo Ventilation Indications, Basics of Algorithm, and Titration

RESEARCH PACKET DENTAL SLEEP MEDICINE

Patricia Carter, PhD, RN, CNS UT Austin School of

Coding for Sleep Disorders Jennifer Rose V. Molano, MD

Identification and Treatment of the Patient with Sleep Related Hypoventilation

They are updated regularly as new NICE guidance is published. To view the latest version of this NICE Pathway see:

PORTABLE OR HOME SLEEP STUDIES FOR ADULT PATIENTS:

OSAS oxidative stress and atherosclerosis Who is the culprit: AHI or ODI

Day care adenotonsillectomy in sleep apnoea

Challenging Cases in Pediatric Polysomnography. Fauziya Hassan, MBBS, MS Assistant Professor Pediatric Pulmonary and Sleep

Bi-Level Therapy: Boosting Comfort & Compliance in Apnea Patients

SLEEP DISORDERED BREATHING AND CHRONIC LUNG DISEASE: UPDATE ON OVERLAP SYNDROMES

The Respiratory System

Up to 50% of continuous flow oxygen therapy patients experience clinically significant nocturnal desaturation. 1

Basics of Polysomnography. Chitra Lal, MD, FCCP, FAASM Assistant professor of Medicine, Pulmonary, Critical Care and Sleep, MUSC, Charleston, SC

Respiratory Assist Device E0470:

Web-Based Home Sleep Testing

Index SLEEP MEDICINE CLINICS. Note: Page numbers of article titles are in boldface type.

1/27/2017 RECOGNITION AND MANAGEMENT OF OBSTRUCTIVE SLEEP APNEA: STRATEGIES TO PREVENT POST-OPERATIVE RESPIRATORY FAILURE DEFINITION PATHOPHYSIOLOGY

Reasons Providers Use Bilevel

Ron Hosp, MS-HSA, RRT Regional Respiratory Specialist. This program has been approved for 1 hour of continuing education credit.

Factors Influencing Sleep Time With Oxygen Saturation Below 90% in Sleep-Disordered Breathing

Mario Kinsella MD FAASM 10/5/2016

MedStar Health considers Continuous Home Pulse Oximetry medically necessary for the following indications:

Patients with COPD run a risk of developing. Underestimation of Nocturnal Hypoxemia Due to Monitoring Conditions in Patients With COPD*

SLEEP STUDIES IN THE VERY, VERY YOUNG

Emergency Department Guideline. Procedural Sedation and Analgesia Policy for the Registered Nurse

Tired of being tired?

Diagnostic Accuracy of the Multivariable Apnea Prediction (MAP) Index as a Screening Tool for Obstructive Sleep Apnea

Polysomnography for Obstructive Sleep Apnea Should Include Arousal-Based Scoring: An American Academy of Sleep Medicine Position Statement

Cardiac Arrhythmias in Sleep

Prefabricated Oral Appliances for Obstructive Sleep Apnea

FAQ CODING & REIMBURSEMENT. WatchPAT TM Home Sleep Test

Influence of upper airways section area on oxygen blood saturation level in patients with obesity and sleep apnea syndrome

Circadian Variations Influential in Circulatory & Vascular Phenomena

An Early Warning Algorithm to Predict Obstructive Sleep Apnea (OSA) Episodes

Questions: What tests are available to diagnose sleep disordered breathing? How do you calculate overall AHI vs obstructive AHI?

The AASM Manual for the Scoring of Sleep and Associated Events

Home Video to Assess the Snoring Child

WRHA Surgery Program. Obstructive Sleep Apnea (OSA)

Stellar 100 Stellar 150

Assessment of a wrist-worn device in the detection of obstructive sleep apnea

Sleep and the Heart Reversing the Effects of Sleep Apnea to Better Manage Heart Disease

Computational Fluid Dynamics Modeling of Amsino OneMask Oxygen Mask

Transcription:

Biocybernetics and Biomedical Engineering 8, Volume 8, Number 3, pp. 7 33 Suitability of New Methods for Pulseoximetric Data Analysis in Screening Diagnostics of Respiratory Disorders During Sleep (RDDS) GRZEGORZ J. HATLIŃSKI*, JERZY K. KOWALSKI, ANDRZEJ KUKWA Otolaryngology Department, Stomatology Division, Medical University of Warsaw, Warsaw, Poland Pulseoximetry is the simplest and the most reliable screening test for diagnosing of Respiratory Disorders During Sleep. Assessment of blood saturation with oxygen is a basic parameter to determine the degree of SAS (Sleep Apnea Syndrome) progression. The authors describe the conventional, but also their own newly developed methods for pulseoximetric data analysis, tested for over 4 patients. The purpose of these new methods is to give physicians easier and more simple means for evaluating patients after all-night blood oxygen saturation monitoring. Inventiveness of this method lies in the possibility of examining of dynamics of blood oxygen saturation during patient s sleep. All received data are stored and can be reported in special 1-hour step intervals to facilitate comparative analysis of subsequent examinations and assess effectiveness of the treatment. Keywords: biomeasurement, pulseoximetry, Respiratory Disorders During Sleep, Sleep Apnea Syndrome 1. Introduction Diagnostics of Respiratory Disorders During Sleep (RDDS) is a relatively new and dynamically developing area of medical science. A characteristic feature of these disorders that are also referred to as unrecognized dyspnea is a significant impediment or even lack of air flow through the upper respiratory tract during patient s sleep due to obturation of the upper respiratory tract or disturbances of the central stimulation of the respiratory drive. The extreme and most severe form of the RDDR is the Sleep Apnea Syndrome (SAS) [1, ]. A direct consequence of these abnormalities result is hypoxia of the organism, which is the most evident in results of blood saturation measurements. The Respiratory Disorders During Sleep are a common phenomenon that affects over 5% of * Correspondence to: Grzegorz J. Hatliński, Otolaryngology Department, Stomatology Division, Medical University of Warsaw, ul. Stępińska 19/5, -739 Warsaw, Poland, e-mail: hatlinski.j@egonet.pl Received 3 January 8, Accepted 1 April 8

8 G.J. Hatliński, J.K. Kowalski, A. Kukwa total population. Due to high requirements with respect to medical personnel and a high cost of a polysomnographic (PSG) examination that involves an all-night recording of physiological signals in order to assess the sleep and breathing parameters, saturation of the blood with oxygen and the heart functions, it is not possible to apply the PSG for the RDDS diagnostics in large-scale screening tests [3, 4, 5]. At present, the most urgent issue is to initiate the RDDS screening examinations that would be characterized in general availability and simple equipment and that would allow for a reliable interpretation correlated with the RDDS. It seems that the nocturnal pulseoximetry fulfils all these requirements. Our experience shows that the pulseoximetry is the most simple and reliable screening test in the RDDS diagnostics. Blood saturation measurement is one of the basic tools to be used in assessing progression of the RDDS.. Purpose The purpose of this work was to assess suitability of our original methods of pulseoximetric data analysis in the screening diagnostics of RDDS. This paper presents conventional and novel methods for analyzing pulseoximetric data, based upon our own experiments as well as on over 4, clinical examinations. A reliable assessment of dynamics of blood saturation changes that are reflecting the progression of RDDS, is the key advantage of the novel methods. The conventional method of analyzing pulseoximetric data (Fig. 1) is based mainly upon statistical assessment of the fraction of the particular pulse and saturation values with respect to the entire examination. The method provides information about mean, maximum and minimum values and graphical representation of distribution of all the pulse and saturation parameters. However, the analysis does not allow for assessing of the dynamics of saturation changes or its morphology. It is not possible to determine whether abnormal test results are the RDDS related or rather a result of a pulmonary or bronchial disease. [BPM] 1 [%] Pulse [%] Pulse [BPM] 1 [%] SaO SaO [%] 5:15: 5:18: 5:1: time 75 Fig. 1. Conventional analysis time fluctuations and percentage distribution of pulse and saturation (SaO )

Suitability of New Methods... 9 Another conventional parameter is the oxygen desaturation index (ODI) that provides the number of episodes when the level of oxygen in blood drops down by 4% within 1 hour of sleep. Anyway, ODI does not account for entire dynamics and morphology of the saturation changes. The most important novel methods include measurement of distribution of saturation drops, the saturation change coefficient (SCC), a graphical presentation of the function F(SaO, Pulse), the desaturation coefficient (DC), and the desaturation vector (DV). 3. Methods and Comparative Analysis The RDDS is recognized if shallow breath or lack of airflow through the upper respiratory tract appear at least ten times (some authors recommend five times) per one hour of sleep with accompanying saturation drops by at least 4%. The novel methods are based upon assessment of the magnitude and frequency of blood saturation changes (Fig. ). Results are presented for the entire examination and in the form of 1-hour intervals. [%] SaO [%] SaO [%] SaO 9 8 7 6 Normal 9 8 7 6 Moderate RDDS 9 8 7 6 Severe RDDS 4 4 :1: :15: 3:1: 3:13: 4 3:15: 3:18: time Fig.. Characteristic 4.5-minute records of blood saturation changes in subjects with normal saturation and with various degrees of RDDS 3.1. Distribution of Saturation Changes Magnitude Disregarding the value of the desaturation index (ODI), magnitude of the saturation drops is the best measure of the RDDS severity (Fig. ). Changes of this parameter are presented as distribution of the number of episodes when the saturation decreases by a given factor ( 4%) during the entire examination and as the average saturation decrease in 1-hour intervals (Fig. 3). In the case when different patients have the same or similar average drop of allnight saturation, the distribution graphs allow for, e.g., differentiating between the RDDS and restrictive respiratory disorders.

3 G.J. Hatliński, J.K. Kowalski, A. Kukwa A B Fig. 3. Distribution of the number of episodes when saturation (dsao ) drops down by a given factor (A) and average saturation drops (AvgDSaO ) in 1-hour time intervals (B) in a RDDS patient 3.. Saturation Change Coefficient (SCC) The SCC is the most sensitive parameters for assessing the dynamics of blood saturation changes and, unlike any other methods discussed in this paper, accounts for one-percent variations. In brief, the SCC is a modified derivative of the blood saturation changes (1), and its magnitude is proportional to the magnitude and frequency of the saturation drops. (1) where: T duration of the examination, t i i-th time point of the examination, S i (t i ) saturation at the time point t i. The SCC is calculated as a single value for the entire examination and as a distribution for 1-hour intervals (Fig. 4). The SCC values that are determined experimentally and correlated with the health condition of the examined individual are as follows: normal from to, RDDS from 6 to, for the values from 3 to 5, a decision should be based upon a visual examination or upon the value of the desaturation index ODI. Fig. 4. SCC distribution in 1-hour time intervals in normal individuals and in various degrees of RDDS

Suitability of New Methods... 31 3.3. Graphical Representation of the Function F(SaO, Pulse) Graphical representation of the function F(SaO, Pulse) presents all interrelations between the pulse and saturation values that are possible in time and space (). The matrix is a convenient means for visual assessment of a pulseoximetric examination (Fig. 5); it allows for a general assessment of dispersion and, by manipulating a time lag slide, internal correlation between SaO and the pulse. F( S, P)= Τ i= ( )= ( )= ( ) ( )= ( )= 1: Si ti, Pi ti 1 : Si ti =, 1 1: Si ti, Pi ti... : Si( ti), : Si( ti), 1 : Si( ti), 1: Si( ti)= 1, 1: Si( ti)= 1, 1 1: Si( ti)= 1,... : Si( ti) 1, : Si( ti) 1, 1 : Si( ti) 1,............ 1: Si( ti)=, 1: Si ( ti)=, 1 1: Si( ti)=,... : Si( ti), : Si( ti), 1 : Si( ti), () where: S SaO, P pulse, T examination time, t i i-th time point of the examination, S i (t i ) SaO at the time point t i, P i (t i ) pulse at the time point t i. A 9 8 7 6 4 3 1 Fig. 5. Matrix F(SaO, Pulse) for individuals with severe RDDS (A) and normal (B) B SaO [%] Pulse [BPM] 4 6 8 1 14 16 18 3.4. Desaturation Coefficient (DC) and Desaturation Vector (DV) The desaturation coefficient (DC) is a bi-parametric quantity that is proportional both to square root of the product of the desaturation index (ODI) and the magnitude of saturation drops (AvgDSaO ) (3). It is calculated as a single value for the entire examination and as a distribution for 1-hour intervals (Fig. 6). The DC values that are determined experimentally and correlated with the health condition of the examined individual are as follows: normal from. to 5.49, RDDS from 5. to 4.. The desaturation vector (DV) is a two-dimensional vector, components of which are the desaturation index and the magnitude of saturation drops (4). The diagnostic decision area is marked within this space (Fig. 6). Aside from diagnostic assessment, DC and DV ensure substantial objectivity of the RDDS treatment results.

3 G.J. Hatliński, J.K. Kowalski, A. Kukwa DC = ODI AvgDSaO (3) DV = ( ODI) + ( AvgDSaO ) (4) A B Fig. 6. Desaturation coefficient DC (A) and desaturation vector DV (B) with a decision area for an individual with severe RDDS 4. Conclusion The novel data analysis methods, implemented in our pulseoximetric systems ensure quick detection of the RDDS and good assessment of the RDDS progression. The methods facilitate intra- and interpersonal comparative analysis, unlike the statistic method they account for morphologic assessment of changes in saturation (dyna mics) and allow for more reliable assessment of casual treatment results. Presentation of data in the form of 1-hour intervals ensures substantial objectivity of comparative analysis of subsequent examinations and assesment of the RDDS treatment results. On grounds of the pulseoximetric examinations, performed so far in over 4, individuals who have been also subject to other examinations with respect to the RDDS diagnostics, we conclude that pulseoximetry is sufficiently effective and the most reliable method for screening tests in the Respiratory Disorders During Sleep (RDDS) diagnostics. References 1. Thorpy M.J.: ICSD International classification of sleep disorders: Diagnostic and coding manual. American Sleep Disorders Association, Rochester, Minnesota. 199a.. Garay S.M., Rapoport D., Sorkin B. et al.: Regulation of Ventilation in the Obstructive Sleep Apnea Syndrome. Am. Re. Respir. Dis., 1981, 14, 451 457.

Suitability of New Methods... 33 3. Kukwa A., Hatliński G.J., Kowalski J.K.: The respi-pulsoxymetric system for the screening data in OSAS patients., Polish Acoustical Society, Waves Methods and Mechanics in Biomedical Engineering, 1999 [in Polish]. 4. Hatliński G.J., Bochenek W., Kukwa A.: The choice of screening or polysomnographic investigation method in patients with the Sleep Apnea Syndrome Polish Acoustical Society, Wave Methods and Mechanics in Biomedical Engineering,. 5. Hatliński G., Kornacki W., Kukwa A.: Multistage Monitoring Procedure for Diagnostic of Respiratory Disorders During a Sleep (RDDS)., Acta Bio- Optica et Informatica Medica, 1/6, vol. 1, 6 [in Polish].