The importance of CT imaging for detecting traumatic intraorbitar and maxillofacial foreign bodies

Similar documents
Original Research THE USE OF REFORMATTED CONE BEAM CT IMAGES IN ASSESSING MID-FACE TRAUMA, WITH A FOCUS ON THE ORBITAL FLOOR FRACTURES

Wooden foreign body in orbit: Endoscopic removal

Reza Javadrashid 1, Farzaneh Kaviany 2, Zahra Shahmorady 3, Mahdi Niknamy 2, Masoud Golamian 4, Shohreh Sadrarhami 4, Mohammad Taghi Niknejad 4

X-Ray & CT Physics / Clinical CT

ORIGINAL PAPERS. Revista Română de Anatomie funcţională şi clinică, macro- şi microscopică şi de Antropologie. Vol. XV Nr

Comparison of the sensitivity for detecting foreign bodies among conventional plain radiography, computed tomography and ultrasonography

2

Clinical management of metallic orbital. Helical and conventional CT in the imaging of metallic foreign bodies in the orbit. Material and Methods

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

The diagnostic value of Computed Tomography in evaluation of maxillofacial Trauma

International Journal of Research in Health Sciences ISSN: Available online at: Case Study

B. CT protocols for the spine

General Imaging. Imaging modalities. Incremental CT. Multislice CT Multislice CT [ MDCT ]

Managing Radiation Risk in Pediatric CT Imaging

Advances in Emergency Imaging

Hi RES Extremity - (04/18/2011) CTDI: ~13 mgy per acquisition Used for evaluation of: Ankle Elbow Hand Wrist Foot /Calcaneous Toes Fingers

Pediatric Isolated Trachea Rupture Treated with a Conservative Approach İ Akdulum 1, M Öztürk 2, N Dağ 1, A Sığırcı 1 ABSTRACT

Clues of a Ruptured Globe

UNIVERSITY OF MEDICINE AND PHARMACY GR. T. POPA - IASI FACULTY OF DENTAL MEDICINE

MRI masterfile Part 5 WM Heme Strokes.ppt 2

Practical CT and MRI Anthony J. Fischetti, DVM, MS, DACVR Department Head of Diagnostic Imaging The Animal Medical Center, New York OBJECTIVE:

Low-dose Three-dimensional CT of Paranasal Sinuses

CT Scanning Protocol For V2R Guided Surgery Solutions

Pattern of ocular trauma in the Western Region of Nepal

Computed Tomography (CT) - Head

PhD THESIS -SUMMARY-

HI-Res Extremity Sensation 16

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Survey of patients CT radiation dose in Jiangsu Province

CT of the Head, Spine, and Cerebral Vessels

Orbital blow-out fractures and race

Patient dose assessment of CT perfusion scanning at the RSCH

The Computed Tomography Examination

Traumatic Optic Neuropathy and Monocular Blindness following Transnasal Penetrating Optic Canal Injury by a Wooden Foreign Body

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

The latest developments - Automated Breast Volume Scanning. Dr. med. M. Golatta

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

INTRALUMINAL GAS IN NON-PERFORATED ACUTE APPENDICITIS: A predictor of gangrenous appendicitis

Cardiac Computed Tomography

Yi Zhang, MD, PhD, DDS,* Yang He, MD, PhD, DDS, Zhi Yong Zhang, MD, PhD, DDS, and Jin Gang An, MD, PhD, DDS

STRUCTURED EDUCATION REQUIREMENTS EFFECTIVE: JANUARY 1, 2016

CT staging in sigmoid diverticulitis

Why is CT Dose of Interest?

MRI masterfile Part 5 WM Heme Strokes.ppt 1

Proceeding of the SEVC Southern European Veterinary Conference

UC SF. g h. Eye Trauma. Martha Neighbor, MD Emergency Services San Francisco General Hospital University of California

Conventional radiograph verses CT for evaluation of sagittal fracture of mandibular condyle

Dual-Energy CT: The Technological Approaches

CT SCAN PROTOCOL. Shoulder

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

Injury. Contusion Lamellar Laceration Laceration Rupture. Penetrating IOFB. Perforating

Supratentorial multiple little meningiomas with transitory stroke symptoms like. MRI case presentation

Role of the Radiologist

FOR CMS (MEDICARE) MEMBERS ONLY NATIONAL COVERAGE DETERMINATION (NCD) FOR MAGNETIC RESONANCE IMAGING:

A SOFTWARE TOOL USED IN 3D EVALUATION OF THE ALVEOLAR BONE DEFECT IN BILATERAL CLEFT LIP AND PALATE PATIENTS

Pediatric CT Protocols (18 years old or less)

RADIATION DOSES FOR X-ray DIAGNOSIS TEETH IN DENTAL MEDICINE

Clinical Image Gallery Next Generation Volume 1

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

TORNIER. scan protocol V2.1. Tornier Upper Extremities

Facial Soft Tissue Thickness in North-West of Iran

Staywell FL Child Medicaid Plan Benefits

Keywords: Mandible, Maxilla, Teeth, Cone Beam CT, Implants, Tumor and tumor-like conditions

Computed Tomography (CT) - Sinuses

Chief Radiographer TEI Clinical Associate 2016

Introduction to Radiology

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SATURDAY CURRICULUM

CT angiography techniques. Boot camp

Underwater Acoustic Measurements in Megahertz Frequency Range.

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

RADIOLOGIC TECHNOLOGY (526)

A Radiographic technique for differentiating enamel and dentin in odontogenic tumors

Assessment of Bone Density Measurements Using Cone Beam Computed Tomography and Multislice Computed Tomography (Experimental Study)

Is Bedside Ultrasound a Reliable Method for Detecting Soft Tissue Foreign Bodies in Upper Extremity Penetrating Trauma Patients?

Threshold Selection for CT Angiography Shaded Surface Display of the Renal Arteries

Bone Densitometry Radiation dose: what you need to know

Low-Dose CT: Clinical Studies & the Radiologist Perspective

Case Report Delayed myelopathy secondary to stab wound with a retained blade tip within the laminae: case report

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

X-ray (Radiography) - Bone

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Management of specific eye problems in the ED

Unusual Posttraumatic Vascular and Cerebral Injuries in Young Patients

Breast Tomosynthesis. What is breast tomosynthesis?

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies

Metal Artifact Reduction by Dual Energy CT

PACS: ERGONOMIC CONSIDERATIONS 1

Ocular Urgencies and Emergencies

Impacted Foreign Body to the Anterior Orbit-A Case Report. ImpactedForeignBodytotheAnteriorOrbit-ACaseReport

DETAILING THE SOFTWARE AIDED DESIGNING OF 3-D MODEL FOR MANDIBULAR RECONSTRUCTION: A CASE REPORT

Where is the contre-coup? Atypical localization of occipital brain contusion

COMPUTED TOMOGRAPHY COURSE

Intraluminal gas in non-perforated acute appendicitis: a CT sign of gangrenous appendicitis

Postprint.

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

Traumatic Partial Optic Nerve Avulsion with Globe luxation. Presented by: Mostafa ElManhaly Resident in Alexandria Faculty Of Medicine

Conjunctival Foreign Body a Rare Presentation

Translating Protocols Across Patient Size: Babies to Bariatric

Transcription:

476 Roxana Popescu et al CT imaging in orbital and facial foreign bodies The importance of CT imaging for detecting traumatic intraorbitar and maxillofacial foreign bodies Roxana Popescu 1, B. Dobrovăţ 2, A. Nemţoi 2, Oana Lăduncă 2, Danisia Haba 3 1 PhD Student, Faculty of Medicine, University of Medicine and Pharmacy Gr. T. Popa Iaşi, Resident in Radiology and Medical Imaging 2 PhD studentdepartment of General and Dental Radiology, Faculty of Medicine, University of Medicine and Pharmacy Gr.T. Popa Iaşi 3 Department of General and Dental Radiology, Faculty of Medicine, University of Medicine and Pharmacy Gr. T. Popa Iaşi, Emergency Hospital N. Oblu Iasi Abstract The study represents an evaluation of the ability of spiral and conventional computer tomography in the diagnoseof intraorbitar and intraocular foreign bodies. The study includes 19 patients, aged between 15 and 52 years, 10 men and 9 women, presenting intraocular or intraorbitar foreign bodies or as a result of an traumatic injuries, who addressed the Emergency Hospital N. Oblu Iasi, between September 2010 - March 2011. The CT examination was the main imaging method of investigation in addition to conventional radiographs; it was conducted on a Philips Aura single-slice unit and a Siemens SOMATOM AR.C unit in the Department of Radiology and Medical Imaging in thehospital N. Oblu Iasi. One patient presents an CT image of carbonite IOFB, 5 patients present metallic IOFB, the images are obtained using used incremental CT (Somatom ARC, Siemens). 2 patients present spiral CT image of a metallic penetrating intraocular foreign body, 11 patients present spiral CT image of a metallic penetrating intraocular and maxillofacial foreign body. The classical computer tomography and spiral CT are among the most effective methods of examination and management of intraocular foreign bodies, maxillofacial or intraorbital. The spiral CT realise a continuous scanning of a volume of the patients body during table movement and reduces examination time and radiation exposure. Keywords: computertomography, IOFB, orbit Introduction Intraorbital foreign bodies (IOFBs) are a common occurrence worldwide and happen at a frequency of once in every six cases of orbital trauma. Metallic foreign bodies are more frecqent than organic, carbonite or glass IOFB (1, 2). Imaging and management should be tailored individually. The intraorbital foreign bodies represent a medical emergency due to major problems caused by complete/ partial loss of vision. The importance results also from the high price of the tratement and of the difficult rehabilitation of the patients. The purpose of the study is the comparative evaluation of the results of

Romanian Neurosurgery (2011) XVIII 4: 476-482 477 incremental CT scan comparing to spiral CT. CT is generally considered to be the gold standard for IOFBs. It is safe to use with metallic IOFBs, excludes orbitocranial extension, and is also able to diagnose orbital wall fractures and orbital sepsis with high accuracy. Abscess formation in the orbit, bone, and brain are other complications that CT may exclude. Spiral CT reduces artifacts from metallic intraorbital foreign bodies, also reduces patients irradiation and the images obtained are higher quality than those from the conventional CT. CT is also accurate for the detection and localization of glass, metal, and stone foreign bodies, and the nature of the IOFB may be deduced from the Hounsfield numbers. Metallic density is easily distinguished on CT, but size overestimation of metals on soft tissue window settings is a wellrecognized occurrence. The CT threshold size for the detection of metallic foreign bodies is 0.07 mm3 with thin slice CT, method is lower sensitivity in case of radiolucent foreign bodies, or where they are located near the sclera (1, 2, 3). CT is useful in case of complex orbital trauma, allowing visualization of soft tissue, bone structures and intraorbital foreign bodies. Advantages of CT examination for are important for complex trauma, in case we have an association of a head injury and orbital, intraocular foreign bodies and the possibility exam the vascular using the contrast substances. Material and method The study includes 19 patients, aged between 15 and 52 years, 10 men and 9 women, presenting intraocular or intraorbitar foreign bodies or as a result of an traumatic injuries, who addressed the Radiology and Ophthalmology departments of the Hospital N. Oblu Iasi, between September 2010 - March 2011. The CT examination was the main imaging method of investigation in addition to conventional radiographs; it was conducted on a Philips Aura single-slice unit and a Siemens SOMATOM AR.C unit in the Department of Radiology and Medical Imaging in the Hospital N. Oblu Iasi. The examination protocol was different depending on the apparatus used: the device Siemens have used sections with a thickness of 3 mm and reconstruction at 3 mm, and on the Philips it could have spiral acquisitions, usually with 2 mm sections, pitch of 3 mm (1.5) and reconstruction at 1 mm. The examination was native, depending on clinical indications and the native exam results, contrast was sometimes given intravenously (Iopamiro, Bracco - Ewopharma, Ultravist, Schering, Omnipaque, GE - Amersham). Routine were performed 2D reconstruction (MPR - "multiplanar reconstructions" or MIP - "maximum intensity projections") and sometimes 3D reconstruction (SSD - "Surface shaded display "DVR-" direct rendering volumes"). Were usually performed section in the axial plane, but for the pathological lesions that affect the orbital floor or ceiling were made direct coronal sections. The opportunity to evaluate fast and very precise the bone and soft tissue damage (orbit, superficial, endocranial) made this method to be preferred for cranio-facial trauma patients, making often in the first line.

478 Roxana Popescu et al CT imaging in orbital and facial foreign bodies Results One case revealed anincremental CT image of a carbonite intraocular and intraorbitar foreign body.in 5 cases we found out incremental CT images of a metalicintraorbitar foreign body. In 3 cases we havespiral CT images of glass intraorbitar foreign bodies. In 2 cases we discovered the spiral CT image of a metallic penetrating intraocular foreign body. The rest of the cases shows spiral CT image of a metallic penetrating intraocular and maxillofacial foreign body. Figures 1, 2, 3 Incremental CT image of a carboniteintraorbital and intraocular foreign

Romanian Neurosurgery (2011) XVIII 4: 476-482 479 Figures 7, 8, 9 Images of CT spiral Philips Aura glass intraorbital foreign body Figures 4, 5, 6 Incremental CT image of an intraorbital foreign body Figures 10, 11, 12 Spiral CT images of penetrant metallic intraocular foreign bodies

480 Roxana Popescu et al CT imaging in orbital and facial foreign bodies Discussion Computer tomography (CT) is an imaging technique that generates sectional images in the axial plan by scanning a beam of X-rays around the body to be examined. CT is based on the determination of attenuation coefficients ( linear absorption) in tissue density of an x-ray beam that passes through the body, the CT image is a "map" of the distribution of tissue densities in the volume of of the section examined (4, 5, 6). A collimate beam (narrow) X-ray beam passes through the patient body and the intensity is measured by an emergent crown of detectors, disposed diametrically opposite to the X-ray tube; for a given position of the radiogenic tube the measured value of the intensity of the emergent beam is called projection. Imagine the object beam is reconstructed by computer through the mathematical analysis of its multiple projections (8). An orbital foreign body may lead to variety of signs, symptoms and clinical findings according to its size, location, velocity and composition. The patients in this study suffered mostly traumatic injuries. Even if the study involved a small number of pacients, the results are similar with other studies on this theme, like the study of Nasr AM, Haik BG, Fleming JC, or study ofleal FAM, Silva e Filho AP. The patients in this study are 12 aged between 25-45 years old, 3 aged between 15-25 years old, 4 persons aged between 35-45 years old and 1 person in the interval between 45-52 years old. We can conclude that the incidence of intraorbital and intraocular foreign bodies from traumatic injuries ( which represents 63,16% from our cases) is increased at persons aged nearly thirteen. We observe that in five cases we have pacients with metallic intraorbital bodies which are the result of small fireworks, petards which expoded in their faces. In three cases the IOFB are made by glass as result of an traffic accidents. One case the IOFB is carbonite in ancasnic accidents. The rest of our cases are also from traffic accidents and the IOFB are metallic. We can see that 52,63% from IOFB at our pacients are from car accidents. 60,00% Metallic intraorbital, intraocular or intramaxillar - car accidents; 52,63% 50,00% 40,00% Carbonite - casnic accidents Metallic - petard, fireworks explosions 30,00% Metallic - petard, fireworks explosions; 26,32% Glass - car accidents 20,00% Glass - car accidents; 15,79% Metallic intraorbital, intraocular or intramaxillar - car accidents 10,00% Carbonite - casnic accidents; 5,26% 0,00% Foreign body type related to generating source

Romanian Neurosurgery (2011) XVIII 4: 476-482 481 70,00% 25-35 years; 63,16% 60,00% 50,00% 40,00% 30,00% 15-25 years 25-35 years 35-45 years 45-52 years 20,00% 35-45 years; 21,05% 10,00% 15-25 years; 10,53% 45-52 years; 5,26% 0,00% Patient age distribution (%) Intraorbital FBs can be associated with severe injuries leading to loss of vision or may lead to sight-threatening complications (8). A retained metallic intraorbital FB may cause a variety of signs, symptoms, and clinical findings, based on its size, location, and composition. Loss of vision is usually due to the initial trauma and is generally not influenced by surgical intervention. The best management of retained metallic intraorbital FBs remains a controversial subject. The decision regarding surgical removal depends mainly on the location and type of intraorbital FB (7). However, the removal of foreign body from the orbit, which is crowded with delicate structures, is not safe. Retained metallic IOFBs are well tolerated and should be managed conservatively in the absence of specific indications for removal (12). When the foreign body is impinging on neurological structures or causing mechanical restriction to ocular movements, one should consider removal of the FB after detailed and precise localization to minimize damage to the adjacent ocular structures (13). Conclusion The classical computer tomography and spiral CT are among the most effective methods of examination and management of intraocular foreign bodies, maxillofacial or intraorbital. The spiral CT realise a continuous scanning of a volume of the patients body during table movement (9, 10). The main advantages are related to the fact that there is no section "lost" due to uneven breathing of the patient from one section to another, it can be achieved quality reconstruction in different planes of space and last but not least we have reduced examination time and radiation dose to the patient that is exposed. CTexam is very important to establish the exact location of the foreign body, to see if the is also an asociated fracture of the

482 Roxana Popescu et al CT imaging in orbital and facial foreign bodies bones of orbit or other bones of the face, and for decide the specific surgical intervention. References 1. Adesania O, Dawkins D. Intraorbital wooden foreign body. EmergRadiolog 2007. 14: 45-49. 2. Betharia SM, Kumar H. Orbital wooden foreign bodies-a case report. Indian J Ophthalmol. 1989; 37:146 7. 3. Brock L, Tanenbaum HL. Retention of wooden foreign bodies in the orbit. Can J Ophthalmol. 1980;15(2):70-2. 4. Bullock JD, Warwar RE, Bartley GB, Waller RR, Henderson JW. Unusual orbital foreign bodies. OphthalPlastReconstr Surg. 1999;15(1):44-51. 5. Cartwright MJ, Kurumety UR, Frueh BR. Intraorbital wood foreign body. OphthalPlastReconstr Surg. 1995;11(1):44-8. 6. Cohen MA, Boyes-Varley G. Penetrating injuries to the maxillofacial region. J Oral Maxillofac Surg. 1986;44(3):197-202. 7. Espaillat A, Enzer I, Stephren L. Intraorbitalmaetallic foreign body. Arch. ophthalmology 1998; 116:824. 8. Figueira EC,Francis IC,Wilcsek GA. Intraorbitalglassforeignbody missed onctimaging. OphthalPlastReconstr Surg.2007; 23(1): 80-2. 9. Finkelstein M, Legmann A, Rubin PA. Projectile metallic foreign bodies in the orbit; A retrospective study of epidemiologic factors, management, and outcomes. Ophthalmology 1997; 104: 96-103. 10. Fulcher TP, McNab AA, Sullivan TJ. Clinical features and management of intraorbital foreign bodies. Ophthalmology 2002; 109: 494-500. 11. Harris AMP, Wood RE, Nortjé CJ, Grotepass F. Deliberately inflicted, penetrating injuries of the maxillofacial region (Jael's syndrome). Report of 4 cases. J Craniomaxillofac Surg. 1988; 16(2):60-3. 12. Hudson DA. Impacted knife injuries of the face. Br J Plast Surg. 1992;45(3):222-4. 13.Kuckelkorn R, Kottek A, Schrage N, Reim M. Poor prognosis of severe chemical and thermal eye burns: the need for adequate emergency care and primary prevention. Int Arch Occup Environ Health. 1995; 67:281 4. 14.Leal FAM, Silva e Filho AP, Neiva DM, Learth JCS, Silveira DB. Trauma ocular ocupacionalporcorpoestranho superficial. Arq Bras Oftalmol. 2003;66(1):57-60. 15.Macrae JA. Diagnosis and management of a wooden orbital foreign body: case report. Br J Ophthamol. 1979;63(12):845-51 16.Mauriello M, Lee H, Nguyen L. CT of soft tissue injuries and orbital fractures. Radiologic Clinics of North America 1999. 17.Motomura H, Taniguchi T, Harada T, Muraoka M. A combined flap reconstruction for full-thickness defects of the medial canthal region. J PlastReconstrAesthet Surg. 2006; 59:747 51. 18.Nasr AM, Haik BG, Fleming JC, Al-Hussain HM, Karcioglu ZA. Penetrating orbital injury with organic foreign bodies. Ophthalmology 1999;106(3):523-32 19.Paia C, Pinsard L, Bluestel C. Intraorbital foreign body.journalfrancaisd ophtalmology 2010; 33(9): 657-66. 20.Reim M, Redbrake C, Schrage Chemical and thermal injuries of the eyes. Surgical and medical treatment based on clinical and pathophysiological findings. Arch SocEspOftalmol. 2001; 76:79 124. 21.Singh V, Kaur A, Agrawal S. An unusual intraorbital foreign body. Indian J Ophthalmol. 2004;52:64 5. 22.Shinohara EH, Heringer L, de Carvalho JP. Impacted knife injuries in the maxillofacial region: report of 2 cases. J Oral Maxillofac Surg. 2001;59(10):1221-3. 23.Tian-lin X,Nileshkumar M, Zhi-han Y, Wei C, Xiao-qiang L, Zhen-quan Z, Ye-hui Z. Trochlear calcification and intraorbital foreign body in ocular trauma patients. Chinese Journal of Traumatology 2009. 210 213. 24.Tuppurainen K, Mantyjarvi M, Puranen M. Wooden foreign particles in the orbit - spontaneous recovery. ActaOphthamol Scand. 1997;75(1):109-11. 25.Zhu Y, Li ZG, Zhang YF. Problems in diagnosis and treatment of orbital foreign body--an analysis of 24 cases. ZhonguaYa Ken 2008. 44(8) 676-80.