Chapter. Victoria Delgado, Claudia Ypenburg, Qing Zhang, Sjoerd A. Mollema, Jeffrey Wing-Hong Fung, Martin J. Schalij, Cheuk-Man Yu, Jeroen J. Bax.

Similar documents
Cover Page. The handle holds various files of this Leiden University dissertation.

Cover Page. The handle holds various files of this Leiden University dissertation.

Long-Term Prognosis After Cardiac Resynchronization Therapy Is Related to the Extent of Left Ventricular Reverse Remodeling at Midterm Follow-Up

Three-dimensional Wall Motion Tracking:

Chapter 25. N Ajmone Marsan, G B Bleeker, R J van Bommel, C JW Borleffs, M Bertini, E R Holman, E E van der Wall, M J Schalij, and J J Bax

Assessment of Left Ventricular Dyssynchrony by Speckle Tracking Strain Imaging

Improvement of Atrial Function and Atrial Reverse Remodeling After Cardiac Resynchronization Therapy for Heart Failure

The Management of Heart Failure after Biventricular Pacing

Cardiac Resynchronization Therapy: Improving Patient Selection and Outcomes

Analysis of LV Lead Position in Cardiac Resynchronization Therapy Using Different Imaging Modalities

Advanced Multi-Layer Speckle Strain Permits Transmural Myocardial Function Analysis in Health and Disease:

Original Article Ventricular Dyssynchrony Patterns in Left Bundle Branch Block, With and Without Heart Failure

Chapter 3. N Ajmone Marsan, G B Bleeker, C Ypenburg, S Ghio, N R van de Veire, E R Holman, E E Van der Wall, L Tavazzi, M J Schalij, and J J Bax

Site of Latest Mechanical Activation, LV Lead Position and Response to Cardiac Resynchronization Therapy

Chapter 7. Eur J Nucl Med Mol Imaging 2008;35:

Chapter. Heart. 2010;96:

Global left ventricular circumferential strain is a marker for both systolic and diastolic myocardial function

Cover Page. The handle holds various files of this Leiden University dissertation.

LV FUNCTION ASSESSMENT: WHAT IS BEYOND EJECTION FRACTION

C h a p t e r 15. Benefit of combined resynchronization and defibrillator therapy in heart failure patients with and without ventricular arrhythmias

The road to successful CRT implantation: The role of echo

Coronary artery disease (CAD) risk factors

DOI: /

Left Ventricular Dyssynchrony in Patients Showing Diastolic Dysfunction without Overt Symptoms of Heart Failure

Cover Page. The handle holds various files of this Leiden University dissertation.

Speckle-Tracking Radial Strain Reveals Left Ventricular Dyssynchrony in Patients With Permanent Right Ventricular Pacing

In the recent years, cardiac resynchronization therapy

Cover Page. The handle holds various files of this Leiden University dissertation.

Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT

Journal of the American College of Cardiology Vol. 46, No. 12, by the American College of Cardiology Foundation ISSN /05/$30.

Indications for and Prediction of Successful Responses of CRT for Patients with Heart Failure

Evaluation of Ejection Fraction in Patients with Cardiac Resynchronization Therapy by Two and Three Dimensional Echocardiography

Dialysis-Dependent Cardiomyopathy Patients Demonstrate Poor Survival Despite Reverse Remodeling With Cardiac Resynchronization Therapy

WHAT DO ELECTROPHYSIOLOGISTS WANT TO KNOW FROM ECHOCARDIOGRAPHERS BEFORE, DURING&AFTER CARDIAC RESYNCHRONIZATION THERAPY?

Effect of Ventricular Pacing on Myocardial Function. Inha University Hospital Sung-Hee Shin

PRESENTER DISCLOSURE INFORMATION. There are no potential conflicts of interest regarding current presentation

Predictive Power of the Baseline QRS Complex Duration for Clinical Response to Cardiac Resynchronisation Therapy

Mechanisms of False Positive Exercise Electrocardiography: Is False Positive Test Truly False?

Predictive Power of the Baseline QRS Complex Duration for Clinical Response to Cardiac Resynchronisation Therapy

Diastolic and Systolic Asynchrony in Patients With Diastolic Heart Failure

Tissue Doppler Imaging in Congenital Heart Disease

VECTORS OF CONTRACTION

T he use of biventricular pacing in patients with heart failure

High prevalence of left ventricular systolic and diastolic asynchrony in patients with congestive heart failure and normal QRS duration

Echocardiographic Parameters of Ventricular Dyssynchrony Validation in Patients With Heart Failure Using Sequential Biventricular Pacing

Validation of echocardiographic 2-dimensional. speckle tracking longitudinal strain imaging for

Research Article. Open Access. Hai-Bo ZHANG 1, Xu MENG 1, Jie HAN 1, Yan LI 1, Ye ZHANG 2, Teng-Yong JIANG 3, Ying-Xin ZHAO 3, Yu-Jie Zhou 3

Original Article Significance of Signal Averaged Electrocardiography in Patients with Advanced Heart Failure and Intraventricular Conduction Delay

Velocity, strain and strain rate: Doppler and Non-Doppler methods. Thoraxcentre, Erasmus MC,Rotterdam

Identification of super-responders to cardiac resynchronization therapy: the importance of symptom duration and left ventricular geometry

Tissue Doppler and Strain Imaging. Steven J. Lester MD, FRCP(C), FACC, FASE

How to Assess Dyssynchrony

Journal of the American College of Cardiology Vol. 58, No. 22, by the American College of Cardiology Foundation ISSN /$36.

Tissue Doppler and Strain Imaging

Implantable cardioverter-defibrillators and cardiac resynchronization therapy

Velocity Vector Imaging as a new approach for cardiac magnetic resonance: Comparison with echocardiography

8/8/2011. CARDIAC RESYCHRONIZATION THERAPY for Heart Failure. Case Presentation. Case Presentation

Cardiac resynchronization therapy (CRT) with biventricular

Chapter 5. N Ajmone Marsan, L F Tops, J J M Westenberg, V Delgado, A de Roos, E E van der Wall, M J Schalij, and J J Bax. Am J Cardiol 2009;104:440 6.

Cardiac Resynchronization Therapy Part 1 Issues Before Device Implantation

Cardiac Resynchronization Therapy for Heart Failure

Improvements in Left Ventricular Diastolic Function After Cardiac Resynchronization Therapy Are Coupled to Response in Systolic Performance

Strain and Strain Rate Imaging How, Why and When?

Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy

Tissue Doppler and Strain Imaging

How To Perform Strain Imaging; Step By Step Approach. Maryam Bo Khamseen Echotechnoligist II EACVI, ARDMS, RCS King Abdulaziz Cardiac Center- Riyadh

Strain Imaging: Myocardial Mechanics Simplified and Applied

Echocardiographic Assessment of Cardiac Resynchronization Therapy

Evaluation of left ventricular dyssynchrony using combined pulsed wave and tissue Doppler imaging

DISCLOSURE. Myocardial Mechanics. Relevant Financial Relationship(s) Off Label Usage

Brian Olshansky, MD, FHRS,* John D. Day, MD, FHRS, Renee M. Sullivan, MD,* Patrick Yong, MSEE, Elizabeth Galle, MS, Jonathan S. Steinberg, MD, FHRS

Cardiac resynchronization therapy (CRT) is an

Heart Online First, published on September 13, 2005 as /hrt

Assessment of left ventricular function by different speckle-tracking software

Pathophysiology and Current Evidence for Detection of Dyssynchrony

Randomized controlled trials have demonstrated that cardiac. Imaging

How to Use Echocardiography for. Cardiac Resynchronization Therapy WHY TRY TO IMPROVE PATIENT SELECTION FOR CRT? PROSPECT: CRT Response at 6 Months

Journal of the American College of Cardiology Vol. 50, No. 13, by the American College of Cardiology Foundation ISSN /07/$32.

Cheuk-Man Yu, MD, Wing-Hong Fung, MRCP, Hong Lin, BM, MM, Qing Zhang, BM, MM, John E. Sanderson, MD, and Chu-Pak Lau, MD

Echocardiography and Noninvasive Imaging in Cardiac Resynchronization Therapy

G Lin, R F Rea, S C Hammill, D L Hayes, P A Brady

How to Approach the Patient with CRT and Recurrent Heart Failure

Comparison of clinical trials evaluating cardiac resynchronization therapy in mild to moderate heart failure

The Effect of Concomitant Cardiac Resynchronization Therapy on Quality of Life in Patients with Heart Failure Undergoing Cardiac Surgery

Alicia Armour, MA, BS, RDCS

Cardiac Resynchronization Therapy Optimization Using Trans Esophageal Doppler in Patients with Dilated Cardiomyopathy

Response of Right Ventricular Size to Treatment with Cardiac Resynchronization Therapy and the Risk of Ventricular Tachyarrhythmias in MADIT-CRT

Tilburg University. Published in: American Heart Journal. Document version: Publisher's PDF, also known as Version of record. Publication date: 2007

Value of echocardiography in chronic dyspnea

1. LV function and remodeling. 2. Contribution of myocardial ischemia due to CAD, and

2/2/2011. Strain and Strain Rate Imaging How, Why and When? Movement vs Deformation. Doppler Myocardial Velocities. Movement. Deformation.

after CRT device activation, the septal flash disappears, and LV reverse remodeling and an increase in contractility are observed.

DON T FORGET TO OPTIMISE DEVICE PROGRAMMING

Resolution of Left Bundle Branch Block Induced Cardiomyopathy by Cardiac Resynchronization Therapy

Left atrial function. Aliakbar Arvandi MD

Chapter. Prediction of atrial fibrillation in patients with implantable cardioverter-defibrillator and heart failure

Importance of CRT team for optimization of the results: a European point of view

The Value of 2D Strain Imaging during Stress Testing

Cover Page. The handle holds various files of this Leiden University dissertation.

EBR Systems, Inc. 686 W. Maude Ave., Suite 102 Sunnyvale, CA USA

Transcription:

16 Chapter Changes in global left ventricular function by multidirectional strain assessment in heart failure patients undergoing cardiac resynchronization therapy Victoria Delgado, Claudia Ypenburg, Qing Zhang, Sjoerd A. Mollema, Jeffrey Wing-Hong Fung, Martin J. Schalij, Cheuk-Man Yu, Jeroen J. Bax. J Am Soc Echocardiogr. 2009;22:688-94

ABSTRACT Aim: To evaluate the acute and late effects of cardiac resynchronization therapy (CRT) on multidirectional left ventricular (LV) strain assessed by 2-dimensional (2D) speckle tracking imaging and automated function imaging (AFI). Methods and Results: Multidirectional LV strain (Global radial [GRS Avg], circumferential [GCS Avg] and longitudinal peak systolic strain [GLPSS Avg]) were measured in 141 heart failure patients before CRT implantation, immediately after and at 3 to 6 months of follow-up. Moreover, the acute effects on multidirectional LV strain were evaluated after interrupting CRT at follow-up. Response to CRT was defined as a decrease in LV end-systolic volume 15%. Responders (57%) and non-responders (43%) showed similar baseline values for GRS Avg, GCS Avg and GLPSS Avg. At follow-up, significant improvement in multidirectional LV strain, combined with significant reverse LV remodeling and improvement in LV ejection fraction, was only noted in responders. Importantly, no significant changes in multidirectional LV strain were observed immediately after CRT device implantation or after interruption of the device at follow-up. Conclusions: Two-dimensional speckle tracking imaging and AFI enable the quantification of multidirectional LV mechanics. Improvement in LV strain in the 3 orthogonal directions after CRT appears to be a long-term effect and is related to the extent of reverse LV remodeling after CRT.

Changes in Global Left Ventricular Function 251 INTRODUCTION It is well established that cardiac resynchronization therapy (CRT) is an effective treatment for advanced heart failure in selected patients. The beneficial effects include improvement in clinical parameters, such as symptoms, quality of life, and exercise distance as well as reduction in hospitalizations and mortality, but also include improvement in functional parameters, including improvement in global left ventricular (LV) function, LV reverse remodeling and reduction in mitral regurgitation. 1-7 Nevertheless, a consistent proportion of patients do not respond to CRT. 1;8;9 In order to understand the high prevalence of non-responders, several non-invasive imaging studies have been performed to study the exact mechanism underlying CRT. 10;11 Two-dimensional (2D) speckle tracking imaging enables the angle-independent assessment of multidirectional LV strain and differentiates those myocardial segments with active contraction from those segments passively tethered. In addition, the novel algorithm automated function imaging (AFI) is a novel echocardiographic technique based on 2D strain imaging that enables quantification of regional and global LV longitudinal strain. 12-15 In the present study, we used 2D speckle tracking imaging and AFI to study the effects of CRT on multidirectional LV strain. Echocardiography was performed at baseline, after CRT initiation, during follow-up and during interruption of biventricular pacing, in order to differentiate between acute and late effects. METHODS Study population and protocol A total of 141 consecutive patients with chronic heart failure, scheduled for implantation of a CRT device, were included in the current study. The selection criteria for CRT included: advanced symptomatic heart failure (New York Heart Association functional class III or IV), LV ejection fraction 35% and QRS duration on surface electrocardiogram 120 ms. 16 Patients with recent myocardial infarction (<3 months) or decompensated heart failure were excluded. Etiology was considered ischemic in the presence of significant coronary artery disease ( 50% stenosis in one or more of the major epicardial coronary arteries) and/or a history of myocardial infarction with electrocardiographic evidence or prior revascularization. The study protocol included a comprehensive echocardiographic evaluation with assessment of multidirectional LV strain with 2D speckle tracking imaging at 4 different times of follow-up: before and within 24-48h after CRT device implantation, and after 3 to 6 months of CRT, with the device activated and after 5 minutes of CRT device interruption. In addition, LV volumes, ejection fraction and mitral regurgitation severity along with clinical parameters were evaluated at baseline and follow-up. Echocardiographic, clinical and LV lead position data were analyzed retrospectively, by two different observers blinded to the recorded data, respectively.

252 Chapter 16 Echocardiographic evaluation Patients were imaged in the left lateral decubitus position using a commercially available system (Vingmed Vivid-7, General Electric Vingmed, Milwaukee, Wisconsin). Data acquisition was performed with a 3.5-MHz transducer at a depth of 16 cm in the parasternal and apical views (standard apical long-axis, 2- and 4-chamber images). Standard 2D images were stored in cineloop format from 3 consecutive beats and were transferred to a workstation for further off-line analysis (EchoPac 6.1, GE Medical Systems, Horten, Norway). LV end-diastolic and end-systolic volumes were derived and LV ejection fraction was calculated from apical 2- and 4-chamber views by Simpson s rule. 17 Mitral regurgitation was evaluated semiquantitatively from color-flow Doppler images at the apical 4-chamber views. Mitral regurgitation was graded on a 3-point scale, according to current guidelines: 18 mild (jet area/left atrial area <20%), moderate (jet area/left atrial area 20-45%) and severe (jet area/left atrial area >45%). In addition, LV dyssynchrony was evaluated with tissue Doppler imaging (TDI) and with 2D speckle tracking radial strain imaging, as previously described. 19-21 With TDI, the time difference between basal septal and basal lateral peak systolic velocities were calculated to define LV dyssynchrony. 19 By applying 2D speckle tracking radial strain imaging to mid-ventricular parasternal short-axis images, LV dyssynchrony was evaluated measuring the time difference between the anteroseptal to (postero)lateral peak radial strain. 20 Patients who showed a decrease of 15% in LV end-systolic volume at follow-up were classified as echocardiographic responders to CRT. (19) Multidirectional LV strain assessment Multidirectional analysis of LV strain (at radial, circumferential and longitudinal directions) was performed using 2D speckle tracking imaging and AFI. The speckles, natural acoustic markers equally distributed within the myocardium, can be detected and tracked on the standard grey-scale 2D images. Myocardial strain can be calculated by measuring the change of the position of the speckles within a myocardial segment along the cardiac cycle. Two-dimensional speckle tracking imaging to assess global radial and circumferential strain The assessment of global radial (GRS Avg) and circumferential strain (GCS Avg) was performed by applying 2D speckle tracking imaging to the parasternal short-axis views of the LV. Radial strain measures the thickening and thinning of the myocardium, whereas circumferential strain measures the shortening and lengthening along the curvature of the LV. The mid-ventricular short-axis of the LV is divided in 6 segments and the values of GRS Avg and GCS Avg are derived from the average of the 6 segmental peak systolic strain values. Conventionally, LV thickening is quantified with positive values and shortening with negative values. However, for the purpose of the present study, circumferential shortening was scored also in positive values. Automated function imaging to assess global LV longitudinal strain Global LV longitudinal strain was quantified using the novel AFI technique. 13 For this purpose, one single cardiac frame is needed form each apical view (apical long-axis, 4- and 2-chamber views) us-

Changes in Global Left Ventricular Function 253 ing a mean frame rate of 70 fps (range 40-100 fps). The method has been described elsewhere. 22 In brief, the LV end-systolic frame is defined in the apical long-axis view and the closure of the aortic valve is marked. The time interval between the R-wave and aortic valve closure is used as a reference for the 4- and 2-chamber view loops. After defining the mitral annulus and the LV apex with 3 index points at the end-systolic frame in each apical view, the automated algorithm traces 3 concentric lines on the endocardial border, the mid-myocardial layer and epicardial border, including the entire myocardial wall. The LV is divided in 6 segments in each apical view and the tracking quality is validated for each segment. Then, the myocardial motion is analyzed and the automated algorithm, using a 17-segment model, provides the peak systolic longitudinal strain for each segment in a polar-map, with the average value of peak systolic longitudinal strain for each view and the averaged global longitudinal peak systolic strain (GLPSS Avg) for the complete LV (Figure 1). Generally, longitudinal strain values are presented as negative values, and a more negative value indicates larger longitudinal strain. However, for the purpose of the present study, the global strain values are presented as positive values. Clinical evaluation Clinical evaluation included evaluation of heart failure symptoms using New York Heart Association functional class, quality-of-life by the Minnesota Living with Heart Failure questionnaire, 23 and exercise tolerance using 6-minute walking distance. 24 QRS duration was measured in all patients from the surface electrocardiogram, using the widest QRS complex from the leads II, V1 and V6. The electrocardiograms were recorded at 25 mm/sec and were evaluated by two independent observers without knowledge of the clinical status of the patient. Device implantation The right atrial and right ventricular leads were positioned conventionally. To insert the LV lead, first a venogram from the coronary sinus was obtained using a guiding balloon catheter. Thereafter, an 8F guiding catheter was used to position the LV lead (Easytrak 4512-80, Guidant Corporation, St. Paul, Minnesota; or Attain-SD 4189, Medtronic Inc., Minneapolis, Minnesota) into the coronary sinus. All leads were connected to a dual-chamber biventricular ICD (Contak CD or TR, Guidant Corporation; or Insync III or CD, Medtronic Inc.). One day after implantation, LV lead position was defined from the chest-x-ray and scored as lateral, posterior or anterior, as previously described. 25 Statistical analysis Continuous variables were presented as mean values ± SD and were compared with 2-tailed Student t test for paired and unpaired data. Categorical data were presented as number and percentage and compared with χ 2 -test and McNemar test, as appropriate. Differences in multidirectional LV strain over time between responders and non-responders were evaluated with analysis of the variance (ANOVA) for repeated measurements. In addition, for overall population and within the same group of patients, GRS Avg, GCS Avg and GLPSS Avg values were compared at 3 different stages: 1) baseline values (PRE) vs. values immediately after implant (ON), 2) PRE vs. follow-up data (F-UP) and 3) F-UP values vs. values after the interruption of the CRT device (OFF). To adjust for inflation of

254 Chapter 16 Figure 1. Changes in global LV longitudinal strain after CRT device implantation. Example of a 17-segment bull s eye display of the LV of a responder to CRT. A red color indicates normal strain values, whereas light-red and blue colors indicate lower strain values. From top to bottom are provided bull s eye displays at baseline (PRE, top), immediately after CRT implantation (POST, middle) and at follow-up (F-UP, bottom). An improvement in global LV longitudinal strain (GLPSS Avg) is shown at follow-up, with an increase in the homogeneous red color-coded area. Abbreviations: CRT: cardiac resynchronization therapy; F-UP: follow-up; GLPSS Avg: global longitudinal peak systolic strain; LV: left ventricular; POST: immediately after biventricular pacemaker implantation; PRE: baseline.

Changes in Global Left Ventricular Function 255 the type I error with multiple tests, we applied a posthoc Bonferroni correction; consequently, a p value < 0.017 was considered significant (0.05 divided by 3 different stages). Furthermore, relation between change in GLPSS Avg and change in LV volumes and ejection fraction was assessed by linear regression analysis. All statistical analyses were performed with SPSS software (version 12.0, SPSS Inc., Chicago, Illinois). A p value <0.05 was considered statistically significant. RESULTS Study population Baseline characteristics of the 141 patients included (mean age 66±11 years, 82% men) are summarized in Table 1. Patients had severe heart failure (mean New York Heart Association class 3.0±0.4), with severe LV dysfunction (mean LV ejection fraction 25±7%) and wide QRS complex (mean 143±36 ms). Ischemic etiology of heart failure was present in 84 patients (60%). In addition, 55 (39%) patients had moderate to severe mitral regurgitation. All patients had optimized medical therapy, in- Table 1. Baseline characteristics n = 141 Age (yrs) 66 ± 11 Male gender (%) 115 (82%) Ischemic etiology (%) 84 (60%) QRS duration (ms) 143 ± 36 Sinus rhythm (%) 121 (86%) NYHA functional class 3.0 ± 0.4 Quality-of-life score 35 ± 18 6-minute walking distance (m) 313 ± 114 LV ejection fraction (%) 25 ± 7 LV end-systolic volume (ml) 156 ± 62 LV end-diastolic volume (ml) 207 ± 71 TDI LV dyssynchrony (ms) 74 ± 44 2D-speckle tracking LV dyssynchrony (ms) 179 ± 127 Mitral regurgitation Moderate Severe Medical therapy ACE-inhibitors Diuretics Beta-blockers Spironolactone 38 (27%) 17 (12%) 121 (86%) 126 (89%) 96 (68%) 35 (25%) Abbreviations: 2D: Two-dimensional; ACE: angiotensin-converting enzyme; LV: left ventricular; NYHA: New York Heart Association; TDI: Tissue Doppler imaging

256 Chapter 16 cluding angiotensin-converting enzyme inhibitors, beta-blockers and diuretics, at maximum tolerated dosages. CRT implantation was successful in all patients and no complications were observed. The LV lead was positioned in a posterior vein in 63 (45%) patients, in a lateral vein in 67 (47%) and an anterior vein in 11 (8%) patients. Changes in clinical status after 6 months of CRT At follow-up, a significant improvement in all clinical parameters was observed in the overall population. Mean New York Heart Association class improved from 3.0±0.4 to 2.0±0.6 (p<0.001), the quality-of-life score improved from 35±18 to 22±20 (p<0.001) and the 6-minute walking distance increased from 313±114 m to 374±121 m (p<0.001). Changes in LV performance after initiation of CRT and at mid-term follow-up After 3 to 6 months of CRT, improvement in LV function and reverse remodeling was noted; LV endsystolic volume decreased from 156±62 ml to 125±60 ml (p<0.001), LV end-diastolic volume decreased from 207±71 ml to 181±69 ml (p<0.001) and LV ejection fraction increased from 25±7% to 33±10% (p<0.001). In addition, mitral regurgitation severity significantly improved at follow-up, with a significant reduction in mitral regurgitation (from 38/17 patients with moderate/severe mitral regurgitation to 13/10 patients respectively, p<0.001). Changes in multidirectional LV strain for overall population are presented in Table 2. Immediately after CRT initiation no change in radial, circumferential or longitudinal strain were noted. However, at mid-term follow-up a significant improvement in all the 3 orthogonal directions of myocardial deformation was observed whereas interruption of CRT did not induce any change in multidirectional strain values. Table 2. Changes in multidirectional LV strain after CRT N = 141 PRE POST F-UP OFF p-value GRS Avg (%) 15.9 ± 9.4 16.6 ± 9.3 20.9 ± 12.8* 18.3 ± 10.2 0.002 GCS Avg (%) 8.2 ± 3.3 8.6 ± 3.7 10.5 ± 4.6* 9.8 ± 4.0 <0.001 GLPSS Avg (%) 7.8 ± 2.8 7.5 ± 3.1 8.5 ± 3.5 8.9 ± 3.7 <0.001 *p <0.001 vs. PRE; p = 0.010 vs. PRE Abbreviations: F-UP = at 3- or 6-month follow-up; GCS Avg = averaged global circumferential strain; GLPSS Avg = averaged global longitudinal peak systolic strain; GRS Avg = averaged global radial strain; OFF = after 3- or 6-month follow-up with interruption of CRT device; POST = within 24-48 hours after implantation of CRT; PRE = baseline. Figure 1 illustrates the example of a patient with improvement of GLPSS Avg at follow-up. Finally, changes in LV longitudinal function as assessed with AFI were related to LV reverse remodeling after 3-6 months of CRT, demonstrating a direct relationship between both parameters (Figures 2 A-C).

Changes in Global Left Ventricular Function 257 Figure 2. Relation between change in global LV longitudinal strain and change in LV volumes and function after CRT. Relation between absolute change in global LV longitudinal strain (GLPSS Avg) and the absolute change in LV ejection fraction (LVEF, panel A), the relative change in LV end-systolic volume (LVESV, panel B) and the relative change in LV end-diastolic volume (LVEDV, panel C) respectively. Responder patients are presented in black dots, whereas non-responders are presented in white dots. Abbreviations: CRT: cardiac resynchronization therapy; GLPSS Avg: global longitudinal peak systolic strain; LV: left ventricular; LVEDV: left ventricular end-diastolic volume; LVEF: left ventricular ejection fraction; LVESV: left ventricular end-systolic volume Responders vs. non-responders Based on a reduction in LV end-systolic volume of 15% after CRT, 80 (57%) patients were classified as responders. There were no differences in baseline characteristics between responders and non-responders, except for significantly more male patients, more ischemic patients, shorter QRS duration and less LV dyssynchrony in the non-responders (Table 3).

258 Chapter 16 Table 3. Baseline characteristics in responders and non-responders Responders (n=80) Non-responders (n=61) p-value Age (yrs) 67 ± 9 64 ± 13 0.1 Male gender (%) 60 (75%) 55 (90%) 0.02 Ischemic etiology (%) 40 (50%) 44 (72%) 0.01 QRS duration (ms) 150 ± 37 135 ± 33 0.01 Sinus rhythm (%) 67 (84%) 54 (88%) 0.7 NYHA functional class 3.0 ± 0.4 3.0 ± 0.4 0.3 Quality-of-life score 33 ± 16 37 ± 19 0.2 6-minute walking distance (m) 323 ± 108 300 ± 121 0.3 LV ejection fraction (%) 26 ± 7 25 ± 7 0.4 LV end-systolic volume (ml) 157 ± 63 155 ± 61 0.8 LV end-diastolic volume (ml) 209 ± 74 204 ± 68 0.6 TDI LV dyssynchrony (ms) 90 ± 40 51 ± 37 <0.001 2D-speckle tracking LV dyssynchrony (ms) 217 ± 129 129 ± 105 <0.001 Abbreviations as in Table 1. At follow-up, responders showed (by definition) significant LV reverse remodeling; LV end-systolic volume decreased from 157±63 ml to 101±52 ml and LV end-diastolic volume decreased from 209±74 ml to 160 ± 67 ml (both p<0.001). As a consequence, a significant improvement in LV ejection fraction was observed (from 26±6% to 38±8%; p<0.001) (Figure 3). In addition, responder patients showed a significant reduction in mitral regurgitation severity (from 27/9 patients with moderate/severe mitral regurgitation to 5/0 patients, respectively; p<0.001). In non-responders no significant changes in LV volumes, ejection fraction or mitral regurgitation severity were observed. At baseline, multidirectional LV strain analysis showed similar values of radial, circumferential and longitudinal strain in responders and non-responders (Figure 4). In responders no acute change in multidirectional LV strain were noted, but a significant improvement in all the 3 orthogonal directions was demonstrated at follow-up. These values remained stable during interruption of biventricular pacing. Conversely, in non-responders, radial, circumferential and longitudinal myocardial strain remained unchanged at follow-up. DISCUSSION This study provides new insights on the effects of CRT on LV function using 2D speckle tracking imaging and the novel echocardiographic AFI technique. The main findings can be summarized as follows: 1) CRT initiation or withdrawal did not induce any acute changes in multidirectional LV strain, however

Changes in Global Left Ventricular Function 259 Figure 3. Changes in echocardiographic parameters after CRT in responders and non-responders Panel A, LV ejection fraction (LVEF); Panel B, LV end-systolic volume (LVESV); and Panel C, LV end-diastolic volume (LVEDV). Grey bars represent baseline parameters whereas the black bars represent follow-up parameters. Abbreviations: as in Figure 2 a significant increase in radial, circumferential and longitudinal strain was noted at long-term followup, 2) changes in GLPSS Avg were related to the extent of LV reverse remodeling after CRT and consequently 3) improvement in multidirectional LV strain during follow-up was only noted in responder patients, whereas non-responders did not show any change in LV deformation pattern. Changes in multidirectional LV function after CRT Despite the dramatic improvement in LV function and reduction in LV volumes after CRT demonstrated in large studies, information regarding changes in multidirectional LV function is limited. To date, few studies have reported the changes in LV radial, circumferential or longitudinal strain after CRT. 26;27 Zhang et al. evaluated in 39 patients changes in multidirectional LV strain after 3 months of CRT. 26 Applying 2D speckle tracking imaging to LV shortaxis images, the authors demonstrated that responder patients showed a significant improvement in radial and circumferential strain at 3-month follow-up. However, in non-responder patients, radial and circumferential strain values remained unchanged. 26 In addition, when 2D speckle tracking imaging was applied to LV apical views, GLPSS Avg value improved in responder patients (from 8.0 ± 2.9% to 9 ± 3.5, p = NS) whereas in non-responder patients, GLPSS Avg decreased (from 7.1 ± 3.8% to 6.2 ± 2.7%, p = NS). 26 Similarly, Becker et al. 27 studied 47 heart failure patients using 2D speckle tracking analysis applied to 4- and 2-chamber views and demonstrated a significant increase in global LV longitudinal strain after 3 months of CRT. 27 The present study confirms those results and demonstrates in a larger population the beneficial effects of CRT on LV mechanics. Relation between changes in multidirectional LV strain and LV reverse remodeling after CRT The effects of CRT can be divided into acute and chronic effects. 10 Studies evaluating the acute effects have demonstrated that CRT abruptly enhances LV systolic function by an increase in stroke

260 Chapter 16 Figure 4. Changes in multidirectional LV strain after CRT according to response Average global LV radial (GRS Avg), circumferential (GCS Avg) and longitudinal strain (GLPSS Avg) in responder and non-responder patients at baseline (PRE), at 24-48h after pacemaker implantation (POST) and at follow-up with the device turned on (F-UP) and turned off (OFF). (*paired t-test for comparisons within the same group (p<0.001). Abbreviations: as in Figure 1 and OFF: at follow-up with the device turned off.

Changes in Global Left Ventricular Function 261 volume, a reduction in LV end-systolic volume, and a rise in LV pressure. 9;28;29 These beneficial hemodynamic effects are the result of the more coordinated (synchronized) contraction of the LV immediately after CRT initiation. Of note, these results are rapidly reversed when CRT is interrupted, and underscore that the acute effect of CRT is related to enhanced and more coordinated (synchronized) LV function. 9 At 6-month follow-up however, the hemodynamic benefits are more related to structural reverse remodeling of the LV. 6;30 Various echocardiographic studies have shown a reduction in LV volumes, associated with an increase in LV ejection fraction, and improvement in mitral regurgitation severity after long-term CRT. 28;30;31 The present study confirms previous findings and, in terms of multidirectional LV strain, myocardial strain pattern has a similar time course: no significant changes were observed immediately after CRT initiation; however, at follow-up, a significant increase in myocardial strain in all the 3 orthogonal directions was observed and remained stable after CRT withdrawal at follow-up. These observations suggest that the increase in multidirectional LV strain is related to structural reverse remodeling, rather than to acute pacing effects, particularly since CRT withdrawal did not reduce myocardial strain. When patients were divided into responders and non-responders, this effect was only observed in responder patients, with a significant increase in multidirectional LV strain at follow-up, that remained unchanged when CRT was turned off. Study Limitations Multidirectional LV strain was evaluated at 4 time-points and no additional data were acquired between hospital discharge (24-48 hours after CRT implantation) and 3-6 months follow-up. Two-dimensional speckle tracking imaging is highly dependent on image quality and frame rate. In the present study, echocardiographic images were acquired at mean frame rate of 70 frames/s. However, in few studies, the frame rate was between 40-50 frames/s. Nevertheless, the strain-time curves obtained were reliable enough to be included in the study. CONCLUSIONS Two-dimensional speckle tracking imaging and the novel AFI algorithm enable quantification of LV systolic function and characterization of its changes after CRT. Improvement in multidirectional LV strain after CRT appears as a long-term effect and is related to the extent of reverse LV remodeling after CRT. REFERENCES (1) Abraham WT, Fisher WG, Smith AL et al. Cardiac resynchronization in chronic heart failure. N Engl J Med 2002;346:1845-1853. (2) Auricchio A, Stellbrink C, Sack S et al. Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. J Am Coll Cardiol 2002;39:2026-2033.

262 Chapter 16 (3) Bristow MR, Saxon LA, Boehmer J et al. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004;350:2140-2150. (4) Cazeau S, Leclercq C, Lavergne T et al. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 2001;344:873-880. (5) Cleland JG, Daubert JC, Erdmann E et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005;352:1539-1549. (6) Sutton MG, Plappert T, Hilpisch KE, Abraham WT, Hayes DL, Chinchoy E. Sustained reverse left ventricular structural remodeling with cardiac resynchronization at one year is a function of etiology: quantitative Doppler echocardiographic evidence from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE). Circulation 2006;113:266-272. (7) Young JB, Abraham WT, Smith AL et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA 2003;289:2685-2694. (8) Bax JJ, Bleeker GB, Marwick TH et al. Left ventricular dyssynchrony predicts response and prognosis after cardiac resynchronization therapy. J Am Coll Cardiol 2004;44:1834-1840. (9) Yu CM, Chau E, Sanderson JE, Fan K et al. Tissue Doppler echocardiographic evidence of reverse remodeling and improved synchronicity by simultaneously delaying regional contraction after biventricular pacing therapy in heart failure. Circulation 2002;105:438-445. (10) Bax JJ, Abraham T, Barold SS et al. Cardiac resynchronization therapy: Part 2--issues during and after device implantation and unresolved questions. J Am Coll Cardiol 2005;46(12):2168-2182. (11) Bax JJ, Abraham T, Barold SS et al. Cardiac resynchronization therapy: Part 1--issues before device implantation. J Am Coll Cardiol 2005;46:2153-2167. (12) Korinek J, Wang J, Sengupta PP et al. Two-dimensional strain--a Doppler-independent ultrasound method for quantitation of regional deformation: validation in vitro and in vivo. J Am Soc Echocardiogr 2005;18:1247-1253. (13) Leitman M, Lysyansky P, Sidenko S et al. Two-dimensional strain-a novel software for real-time quantitative echocardiographic assessment of myocardial function. J Am Soc Echocardiogr 2004;17:1021-1029. (14) Perk G, Tunick PA, Kronzon I. Non-Doppler two-dimensional strain imaging by echocardiography--from technical considerations to clinical applications. J Am Soc Echocardiogr 2007;20:234-243. (15) Reisner SA, Lysyansky P, Agmon Y, Mutlak D, Lessick J, Friedman Z. Global longitudinal strain: a novel index of left ventricular systolic function. J Am Soc Echocardiogr 2004;17:630-633. (16) Strickberger SA, Conti J, Daoud EG et al. Patient selection for cardiac resynchronization therapy: from the Council on Clinical Cardiology Subcommittee on Electrocardiography and Arrhythmias and the Quality of Care and Outcomes Research Interdisciplinary Working Group, in collaboration with the Heart Rhythm Society. Circulation 2005;111:2146-2150. (17) Lang RM, Bierig M, Devereux RB et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005;18:1440-1463. (18) Bonow RO, Carabello BA, Kanu C et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): developed in collaboration with the Society of Cardiovascular Anesthesiologists: endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. Circulation 2006;114:e84-231. (19) Bleeker GB, Bax JJ, Fung JW et al. Clinical versus echocardiographic parameters to assess response to cardiac resynchronization therapy. Am J Cardiol 2006;97:260-263. (20) Delgado V, Ypenburg C, van Bommel RJ et al. Assessment of left ventricular dyssynchrony by speckle tracking strain imaging comparison between longitudinal, circumferential, and radial strain in cardiac resynchronization therapy. J Am Coll Cardiol 2008;51:1944-1952. (21) Donal E, Tournoux F, Leclercq C et al. Assessment of longitudinal and radial ventricular dyssynchrony in ischemic and nonischemic chronic systolic heart failure: a two-dimensional echocardiographic speckle-tracking strain study. J Am Soc Echocardiogr 2008;21:58-65. (22) Delgado V, Mollema SA, Ypenburg C et al. Relation between global left ventricular longitudinal strain assessed with novel automated function imaging and biplane left ventricular ejection fraction in

Changes in Global Left Ventricular Function 263 patients with coronary artery disease. J Am Soc Echocardiogr 2008;21:1244-1250. (23) Rector TS, Kubo SH, Cohn JN. Validity of the Minnesota Living with Heart Failure questionnaire as a measure of therapeutic response to enalapril or placebo. Am J Cardiol 1993;71:1106-1107. (24) Lipkin G, Knecht ME, Rosenberg M. A potent inhibitor of normal and transformed cell growth derived from contact-inhibited cells. Cancer Res 1978;38:635-643. (25) Molhoek SG, Bax JJ, Bleeker GB et al. Long-term follow-up of cardiac resynchronization therapy in patients with end-stage heart failure. J Cardiovasc Electrophysiol 2005;16:701-707. (26) Zhang Q, Fung JW, Yip GW et al. Improvement of left ventricular myocardial short-axis, but not longaxis function or torsion after cardiac resynchronisation therapy: an assessment by two-dimensional speckle tracking. Heart 2008;94:1464-1471. (27) Becker M, Franke A, Breithardt OA et al. Impact of left ventricular lead position on the efficacy of cardiac resynchronisation therapy: a two-dimensional strain echocardiography study. Heart 2007;93:1197-1203. (28) St John Sutton MG, Plappert T, Abraham WT et al. Effect of cardiac resynchronization therapy on left ventricular size and function in chronic heart failure. Circulation 2003;107:1985-1990. (29) Tanabe M, Lamia B, Tanaka H, Schwartzman D, Pinsky MR, Gorcsan J, III. Echocardiographic speckle tracking radial strain imaging to assess ventricular dyssynchrony in a pacing model of resynchronization therapy. J Am Soc Echocardiogr 2008;21:1382-1388. (30) Zhang Q, Fung JW, Auricchio A et al. Differential change in left ventricular mass and regional wall thickness after cardiac resynchronization therapy for heart failure. Eur Heart J 2006;27:1423-1430. (31) Ypenburg C, van Bommel RJ, Marsan NA et al. Effects of interruption of long-term cardiac resynchronization therapy on left ventricular function and dyssynchrony. Am J Cardiol 2008;102:718-721.