A Legacy of Serving the Surgical Community

Similar documents
SMARTLockTM. Hybrid MMFTM

Customized Mandible Reconstruction Plate

CMF. Maxillofacial portfolio

Universal Select. Legacy meets flexibility

MEDPOR. Oral maxillofacial surgery

30+ MEDPOR biomaterial. years of proven clinical history

Craniomaxillofacial. Customized Mandible Reconstruction Plate. Patient Specific Design Powered by BluePrint Technology

Leibinger Next Generation Universal Trocar System

Craniomaxillofacial. Universal Trocar System

Universal NeuroTM III. 1.5mm Cranial fixation system

matrixwave tm mmf expand your possibilities A novel system that expands and compresses to achieve maxillomandibular fixation

MEDPOR. Oculoplastic surgery

MATRIX PLATFORM FEATURES DESIGNED TO COMPLEMENT AO FIXATION PRINCIPLES

Cranial idtm. Cranial restoration. id SolutionsTM. Individually designed. Personalized care.

Mandible Reconstruction Module Reference ence Guide

MatrixNEURO. The next generation cranial plating system.

A Novel Technology for Maxillomandibular Fixation: Universal SMARTLock Hybrid MMF

Multi-Guide II Mandibular Distractor

low ProfIle neuro PlaTIng system

MEDPOR. Plastic surgery

Resorbable Implant Technology

Low Profile Neuro Plating System. Surgical Technique

Technique Guide. IMF Screw Set. For intermaxillary fixation.

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

MatrixNEURO Cranial Plating System

Flexibility In Action. ACL Instrumentation

OsteoMed Angle Locking Fixation System provides surgeons with up to 20 degrees of angulation in the 2.0mm and 2.4mm plate and screw options.

AVS ARIA TM Product Overview

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

HydroSet. Fast-setting HA bone substitute

Direct. DirectInject Stryker CMF. Craniomaxillofacial. Operative Technique

versatile SOLUTION for COMPLEX fractures

versatile SOLUTION for COMPLEX fractures

VBOSS TM System Overview. Vertebral Body Support System

CRANIAL RECONSTRUCTION SOLUTIONS

SynPOR HD Facial Shape System. For the augmentation or reconstruction of the craniomaxillofacial skeleton.

Dentoalveolar Bone Fixation System. Bone fixation sets for the office.

Resorbable Implant Technology

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

RibFix Blu. Thoracic Fixation System

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones.

SYNPOR HD FACIAL SHAPE SYSTEM SURGICAL TECHNIQUE. For the augmentation or reconstruction of the craniomaxillofacial skeleton

AxSOS Locking Plate System

Cranial System. Neuro Plating and Screw System

Gamma3 TM Fragment Control Clip

VersiTomic Flexible Reaming System

Asnis. Micro Cannulated screw system. Xpress operative technique

VariAx TM Distal Radius Locking Plate System

Enhanced Microfracture

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

VariAx Distal Radius Locking Plate System

ANATOMIC LOCKED PLATING SYSTEM

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

Compact Distal Radius System. Consolidated solution for Distal Radius Plating Systems

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

2.0 mm Mandible Locking Plate System

Orbital Plating System OPS 1.5

MatrixNEURO. The next generation cranial plating system.

Driving performance, delivering versatility. Spetzler -Malis and SILVERGlide Non-Stick Bipolar Forceps

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment

EasyStep. Operative technique

Surgical Technique. Calcaneal Locking Plate

Surgical Technique. Proximal Humerus Locking Plate

VariAx Compression Plating System. Operative technique

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Procedures.

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

orthodontic Bone anchor (oba) SYStem

Aero -C. StraightForward insertion Remarkable compression 1. Featuring Aerofoil Compression Technology

TraumaOne LORENZ PLATING SYSTEM

VLIFT System Overview. Vertebral Body Replacement System

RAPIDSORB RAPID RESORBABLE FIXATION SYSTEM. A new resorbable approach to Alveolar bone augmentation

Surgical Technique. Olecranon Locking Plate

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Surgical Technique. Clavicle Locking Plate

Surgical Technique International Version. Clavicle Locking Plate

P a rt i a l Knee Ar t h r o p l a s t y (PKA) Surgical Technique Overview

3.5 mm Locking Attachment Plate

WINSTA-C. Clavicle Plating System

Compact 2.0 LOCK Mandible. The locking system for the mandible.

Single Axis Revision Knee System

Technique Guide. Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Prodecures.

Technique Guide. VersiTomic. ReelX STT Double-Row Achilles G-Lok. J. Martin Leland III, M.D. J. Martin Leland III, M.D. Proximal Biceps Tenodesis

Hoffmann II Micro External Fixation System. Indications for the Hand

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Surgical technique. IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults.

Compact Midface. The systematic solution for craniomaxillofacial indications and displacement osteotomies.

with Ø Ø 1.5 mm Titanium Screws distributed by ARCS Alveolar Reconstruction System E

PAL Pelvic Alignment Level

Mandible External Fixator II

MatrixRIB. Stable fixation of normal and osteoporotic ribs.

Basic Trocar System. Basic transbuccal instrumentation system for simplified intraoral plate and screw application.

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

Surgical Technique. Targeter Systems Overview

Transcription:

TM

A Legacy of Serving the Surgical Community Step By Step Instructions For over half a century, Stryker has been developing products based on the expressed needs of leading practitioners. Introducing SMARTLock Hybrid MMF A revolutionary, patented product designed to combine the strength and rigidity of arch bars with the safety and efficiency of MMF screws. With nine potential points of fixation along the plate, posterior fixation and vector control are enhanced when compared to traditional MMF screws. The self-drilling, locking technology of the screws allows for purchase into both the bone and the plate for additional stability. This plate and screw combination omits the need for interdental wiring that is required with arch bars, and thereby reduces the chance of wire stick injuries for health care providers. Contour the plate. 1 You will only find this unique design from Stryker Craniomaxillofacial. US Pat. 8,118,850 FEATURE Reinvented versatile arch bar plate design BENEFIT Eliminates interdental wiring POTENTIAL VALUE Improves OR efficiency Reduces risk of wire stick injuries Eliminates risk of tooth loosening Eliminates need for OR based removal Optimized self-drilling screw with patented SMARTLock technology Minimizes risk of screw backout Rigid plate-to-screw construct Strong, stable anterior and posterior fixation Dedicated instrumentation Ability to fixate with patient specific anatomical structures in mind Reduces risk of tooth root injuries Reduces risk of pressure necrosis US Pat. 6,322,562 Adjust the length of the locking plate with the cutter. 2 Insert locking screw into the center of the plate hole while positioning the spacer instrument between the mucosa and the metal rim of the plate hole. The bar of the middle plate hole is marked to provide midline orientation. 3

A Legacy of Serving the Surgical Community Step By Step Instructions For over half a century, Stryker has been developing products based on the expressed needs of leading practitioners. Introducing SMARTLock Hybrid MMF A revolutionary, patented product designed to combine the strength and rigidity of arch bars with the safety and efficiency of MMF screws. With nine potential points of fixation along the plate, posterior fixation and vector control are enhanced when compared to traditional MMF screws. The self-drilling, locking technology of the screws allows for purchase into both the bone and the plate for additional stability. This plate and screw combination omits the need for interdental wiring that is required with arch bars, and thereby reduces the chance of wire stick injuries for health care providers. Contour the plate. 1 You will only find this unique design from Stryker Craniomaxillofacial. US Pat. 8,118,850 FEATURE Reinvented versatile arch bar plate design BENEFIT Eliminates interdental wiring POTENTIAL VALUE Improves OR efficiency Reduces risk of wire stick injuries Eliminates risk of tooth loosening Eliminates need for OR based removal Optimized self-drilling screw with patented SMARTLock technology Minimizes risk of screw backout Rigid plate-to-screw construct Strong, stable anterior and posterior fixation Dedicated instrumentation Ability to fixate with patient specific anatomical structures in mind Reduces risk of tooth root injuries Reduces risk of pressure necrosis US Pat. 6,322,562 Adjust the length of the locking plate with the cutter. 2 Insert locking screw into the center of the plate hole while positioning the spacer instrument between the mucosa and the metal rim of the plate hole. The bar of the middle plate hole is marked to provide midline orientation. 3

Complementary Products Verify that all plate holes are directed away from or placed in-between the tooth roots. Use the bender instrument for in-situ adjustments of the plate holes, if needed. 4 Insert a locking screw into at least every other plate hole while using the spacer instrument to avoid compression on the gingiva. 5 Use the hooks of the locking plates as anchor points to apply the wires between the mandible and maxilla. 6 Universal II System The Leibinger Universal CMF Trauma System represents the next generation of bone fixation for all Craniomaxillofacial fractures, orthognathic, and reconstructive needs. Implant modules for specific anatomical areas Fully customizable for clinician and hospital needs Color coordinated "universal" instrumentation & implants SMARTLock locking technology CMF Customized Implants CMF Customized Implants (CI) are designed specifically for each patient to correct trauma and/or defects in maxillofacial or craniofacial bone. Stryker CI technology offers excellent anatomical fit and contour allowing surgeons to create exceptional cosmetic results. PEEK Customized Cranial Implant Kit is intended to replace bony voids in the cranial and craniofacial skeleton. PEEK MEDPOR Reconstructive Implants MEDPOR Porous Polyethylene Implants provide surgeons with an expanding range of options for reconstruction and augmentation. MEDPOR is a biocompatible, porous polyethylene material. The interconnecting, omni-directional pore structure may allow for fibrovascular in-growth and integration of the patient s tissue. More than 400,000 procedures have been performed with MEDPOR Biomaterial, with more than 350 published clinical reports in cranial, reconstructive, oculoplastic and cosmetic applications. Craniofacial reconstruction and repair of the craniofacial skeleton Implants with titanium mesh embedded in the MEDPOR Biomaterial are designed to help the implant retain its shape when bent and contoured to meet a specific patient defect May be trimmed and cut with surgical scissors. Easily fixated with plates/screws and designed to stay in place Colorado Needle The Colorado Microdissection Needle has an ultra-sharp tip for clean, precise soft tissue dissection. The heat resistant tungsten alloy maintains tip sharpness, and is highly polished for easy cleaning. We offer a wide selection of needle electrodes and standard shaft sizes for use in standard handpieces. Precise electro-cutting and coagulation during electrosurgery

Ordering Information PART NO. DESCRIPTION PART NO. DESCRIPTION 55-02950 SmartLock Hybrid MMF Plate 62-00604 SmartLock Hybrid MMF Bender 50-20596 Locking Screws, SD, 2.0x6mm 62-00605 SmartLock Hybrid MMF Spacer 50-20598 Locking Screws, SD, 2.0x8mm OPTIONAL 50-20358 50-20362 MMF Screws, SD, 2.0x8mm MMF Screws, SD, 2.0x12mm 01-03490 Ligature Wires, Blunt, 0.5x160mm, 24 gauge 01-03492 Ligature Wires, Blunt, 0.64x160mm, 22 gauge 60-16526 Twist Drill 1.6x58mm, 20mm WL, Stryker End 62-20130 2.0/2.3 Screwdriver Blade for Self-Drilling Locking Screws 62-20135 MMF Screwdriver Blade and Grasping Sleeve, Assembled 62-20290 Screwdriver Handle, Ratcheting 62-18330 In-situ Plate Cutter 36-06720 Automatic Wire Twister 15cm 29-20420 SmartLock Hybrid MMF Module with Lid 29-20421 SmartLock Hybrid MMF Inlay 29-20426 SmartLock Hybrid MMF Container Lid, Quarter Size 29-15031 Universal Container, Quarter Size, Two-layer 29-15036 Accessory Tray, Quarter Size 29-15037 Silicone Mat For Accessory Tray, Quarter Size

Ordering Information PART NO. DESCRIPTION PART NO. DESCRIPTION 55-02950 SmartLock Hybrid MMF Plate 62-00604 SmartLock Hybrid MMF Bender 50-20596 Locking Screws, SD, 2.0x6mm 62-00605 SmartLock Hybrid MMF Spacer 50-20598 Locking Screws, SD, 2.0x8mm OPTIONAL 50-20358 50-20362 MMF Screws, SD, 2.0x8mm MMF Screws, SD, 2.0x12mm 01-03490 Ligature Wires, Blunt, 0.5x160mm, 24 gauge 01-03492 Ligature Wires, Blunt, 0.64x160mm, 22 gauge 60-16526 Twist Drill 1.6x58mm, 20mm WL, Stryker End 62-20130 2.0/2.3 Screwdriver Blade for Self-Drilling Locking Screws 62-20135 MMF Screwdriver Blade and Grasping Sleeve, Assembled 62-20290 Screwdriver Handle, Ratcheting 62-18330 In-situ Plate Cutter 36-06720 Automatic Wire Twister 15cm 29-20420 SmartLock Hybrid MMF Module with Lid 29-20421 SmartLock Hybrid MMF Inlay 29-20426 SmartLock Hybrid MMF Container Lid, Quarter Size 29-15031 Universal Container, Quarter Size, Two-layer 29-15036 Accessory Tray, Quarter Size 29-15037 Silicone Mat For Accessory Tray, Quarter Size

Complementary Products Verify that all plate holes are directed away from or placed in-between the tooth roots. Use the bender instrument for in-situ adjustments of the plate holes, if needed. 4 Insert a locking screw into at least every other plate hole while using the spacer instrument to avoid compression on the gingiva. 5 Use the hooks of the locking plates as anchor points to apply the wires between the mandible and maxilla. 6 Universal II System The Leibinger Universal CMF Trauma System represents the next generation of bone fixation for all Craniomaxillofacial fractures, orthognathic, and reconstructive needs. Implant modules for specific anatomical areas Fully customizable for clinician and hospital needs Color coordinated "universal" instrumentation & implants SMARTLock locking technology CMF Customized Implants CMF Customized Implants (CI) are designed specifically for each patient to correct trauma and/or defects in maxillofacial or craniofacial bone. Stryker CI technology offers excellent anatomical fit and contour allowing surgeons to create exceptional cosmetic results. PEEK Customized Cranial Implant Kit is intended to replace bony voids in the cranial and craniofacial skeleton. PEEK MEDPOR Reconstructive Implants MEDPOR Porous Polyethylene Implants provide surgeons with an expanding range of options for reconstruction and augmentation. MEDPOR is a biocompatible, porous polyethylene material. The interconnecting, omni-directional pore structure may allow for fibrovascular in-growth and integration of the patient s tissue. More than 400,000 procedures have been performed with MEDPOR Biomaterial, with more than 350 published clinical reports in cranial, reconstructive, oculoplastic and cosmetic applications. Craniofacial reconstruction and repair of the craniofacial skeleton Implants with titanium mesh embedded in the MEDPOR Biomaterial are designed to help the implant retain its shape when bent and contoured to meet a specific patient defect May be trimmed and cut with surgical scissors. Easily fixated with plates/screws and designed to stay in place Colorado Needle The Colorado Microdissection Needle has an ultra-sharp tip for clean, precise soft tissue dissection. The heat resistant tungsten alloy maintains tip sharpness, and is highly polished for easy cleaning. We offer a wide selection of needle electrodes and standard shaft sizes for use in standard handpieces. Precise electro-cutting and coagulation during electrosurgery

A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery. The information presented is intended to demonstrate the breadth of Stryker product offerings. A surgeon must always refer to the package insert, product label and/or instructions for use before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Colorado, Leibinger, MEDPOR, SMARTLock, Stryker. All other trademarks are trademarks of their respective owners or holders. Literature Number 9410-400-374-SSP Rev. None Stryker Australia 8 Herbert Street St Leonards NSW 2065 Australia Ph: + 61 2 9467 1000 Fax: + 61 2 9467 1010 Stryker New Zealand 515 Mt Wellington Highway Auckland 1060 New Zealand Ph: + 64 9 573 1890 Fax: + 64 9 573 1891 www.stryker.com Copyright 2012 Stryker Printed in Australia