Scan Bi-Polar 22/28. Operative Technique

Similar documents
Bi-Polar 22.2mm & 28mm System - Operative technique

FLH /11

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Arcos Interlocking Distal Stem. Surgical Technique Addendum to the Arcos Modular Femoral Revision System

operative technique Kent Hip

SURGICAL TECHNIQUE. Pivot Bipolar Solitude Unipolar

Peanut Growth Control Plating System

Bone Preservation Stem

Dual Mobility System Surgical technique

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Dual Mobility System Evaluation surgical technique

ReCap Product Rationale

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Optimum implant geometry

Modular Unipolar Femoral Head Replacement. Surgical Technique

ACETABULAR CUP SURGICAL TECHNIQUE

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

Manza Cup HA SURGICAL TECHNIQUE.

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

Pre-Operative Planning. Positioning of the Patient

Ovation Hip System. Surgical Technique

AVANTEON. Operative Technique & Catalogue Information AVANTEON

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

21st Century Fracture Management ETS. Surgical Protocol

Approach Patients with Confidence

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Trinity. Advanced Bearing Acetabular System Surgical technique

Arcos Modular Femoral Revision System. Broach and Calcar Proximal Bodies Surgical Technique

Clinical Evaluation Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

Metasul LDH Large Diameter Head

OPTIONAL/ADDITIONAL INSTRUMENTS

Approach Patients with Confidence

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

TaperFit. Cemented Total Hip Replacement Surgical technique

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Cementless Tapered Femoral Stem Surgical technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

OSS Orthopedic Salvage System Compress Device. Surgical Technique

Trilogy Acetabular System

Optimum implant geometry

Trilogy Acetabular System

Cemented femoral stem - type CSC

Preoperative Planning. The primary objectives of preoperative planning are to:

asterloc Surgical Technique HIP SYSTEM UNDERSTANDING TRADITION, MASTERING INNOVATION Hip Knee Spine Navigation

Revision Modular Stem type RMD

AML Hip System. Design Rationale/ Surgical Technique

Duraloc CONSTRAINED LINER

HELIOS h i p s y s t e m

Longevity Offset and Oblique Liners. Surgical Technique

Optimizing function Maximizing survivorship Accelerating recovery

MITCH TRH System Modular Head Operative Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

FMP Surgical Technique

Positioning Sleeve Surgical Technique

Aesculap Trilliance Triple Tapered Polished Hip Stem

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Tradition Hip Primary Surgical Technique

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Trilogy Acetabular System

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Surgical technique. Dynamic Simulation Personalised Solution

MetaFix. Cementless Total Hip Replacement Surgical technique

Arcos Modular Femoral Revision System

CemtA Stem. Surgery Manual. cemented femoral Stem. veterinary implants

Taperloc Complete Hip System. Surgical Technique

Resurfacing Distal Femur. Orthopaedic Salvage System

Absolut TM Cemented Stem. Surgical Technique

Fixed and Variable Geometry Total Shoulder Arthroplasty

Surgical procedure. METS Modular Proximal Femur

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

PLR. Proximal Loading Revision Hip System

HIP SYSTEM SURGICAL TECHNIQUE

Surgical Technique.

Integral 180 Surgical Technique

9800 Metric Blvd. Austin, Texas

28 Surgical Technique

FLT105 12/02.

Operative Technique Crown Cup Acetabular System

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

RECOVERY. P r o t r u s i o

The Leader in Orthopaedic Innovation

System Surgical Protocol

Ease of Use. Have the instrument you need when you need it.

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

REFLECTION Constrained Liner Introduction

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

3.0 mm Cannulated Screw System. Surgical Technique

Bone Conserving Hip Replacement Surgical technique

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Biomet Multi-Axial Correction (MAC) System Correction Atlas

Optimum implant geometry

ZMR Porous Revision Hip Prosthesis. Surgical Technique IMAGE TO COME

ADM X3 Mobile Bearing Hip. System Surgical Protocol. Available with X3 Advanced Bearing Technology. For Use With Restoration ADM Cups and Inserts

TOTAL KNEE ARTHROPLASTY SYSTEM

Transcription:

Scan Bi-Polar 22/28 Operative Technique

Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual property rights owned by or licensed to Biomet or its affiliates. This publication must not be used, copied or reproduced in whole or in part for any purposes other than marketing by Biomet or its authorised representatives. Use for any other purposes is prohibited. Biomet does not practice medicine and does not recommend any particular orthopaedic implant or surgical technique and is not responsible for use on a specific patient. The surgeon who performs any implant procedure is responsible for determining and utilising the appropriate techniques for implanting prosthesis in each individual patient.

The Scan Bi-Polar Hip System 22mm & 28mm Bi-Polar 22.2mm & 28mm System - Operative technique Overview The Scan Bi-Polar System is an alternative to a total hip arthroplasty. The aim of the Bi-Polar prosthesis is to reduce wear or erosion of the acetabulum by providing motion between the prosthetic head and the inner articulation bearing whilst also allowing for extreme range of motion. The Scan Bi-Polar design also incorporates positive eccentricity favouring valgus acetabular component positioning. The chance of dislocation is therefore reduced and the stress more evenly distributed within the acetabular cartilage. The Scan Bi-Polar System component is simple and easy to use. The system comprises of stainless steel Bi-Polar component that can only be assembled with the Scan 22.22mm and 28mm modular femoral heads. The snap-lock mechanism is designed to resist modular head dislocation from within the Bi-Polar component. It is efficient and easy-to-use and designed for optimal femoral head security. 1. Pre-operative Planning Selection of the correct femoral component is attained through careful pre-operative planning. This can be achieved manually by means of x-ray templates, or digitally by means of a PAC system. Manual Pre-operative Planning The Scan Bi-Polar System includes femoral x-ray templates in 115% magnification. These templates are positioned over the AP and Lateral x-rays to best decide the correct implant size and modular head neck length to help restore the patient s natural anatomy. Digital Pre-operative Planning The Scan Bi-Polar System digital templates are available through various digital template providers. When using digital templating for a primary THR, it is necessary to use a magnification marker with a known dimension. This is required in order for the PAC system to calculate the correct magnification. As soon as the correct magnification has been determined, the PAC System can be used to best decide the correct implant size and modular head neck length required to help restore the patient s natural anatomy. 2

Operative Technique 1. Surgical exposure The Scan Bi-Polar component can be implanted using any of the standard approaches for total hip replacement. The aim of the approach selected is to provide adequate visualisation of both the acetabulum and proximal femur. 2. Femoral Components The Scan Bi-Polar System has been designed to assemble with any Biomet femoral component that utilise the Scan 22.22mm or 28mm CoCr femoral heads. Please refer to appropriate femoral prosthesis operative technique for relevant information. 3. Acetabular Sizing Acetabular sizing can be completed by one of two methods. The first method utilises the resected anatomic femoral head with the head gauges. The resected femoral head is passed through the circular cutouts in the gauges until the correct diameter is determined (Figure 1). The second method utilises the trial Bi-Polar shells in conjunction with the gauge handle. The trial Bi-Polar shells of different diameters are inserted into the acetabulum until the most appropriate diameter shell is determined (Figure 2). figure 1 Warning. The Bi-Polar component must not be undersized or oversized. Failure to select the correct diameter component will increase the risk of premature failure. figure 2 3

The Scan Bi-Polar Hip System 22mm & 28mm 4. Femoral Component Insertion and Trial Reduction Prior to femoral preparation and insertion of the femoral component, please refer to relevant operative technique. It is possible to complete a trial reduction by using either the femoral rasp as a trial component or the implanted femoral component. Either way, the aim of the trial is to select the most accurate length of femoral head that best restores the patient s natural anatomy. Once the correct diameter of Bi-Polar component has been determined, the equivalent diameter trial Bi-Polar shell is assembled with the appropriate trial femoral head and assembled with either the femoral rasp (Figure 3) or with the femoral component (Figure 4). Trial femoral heads are available in numerous neck lengths so it may be necessary to undertake the trial reduction several times to ensure the correct length modular head has been selected. figure 3 figure 4 5. Bi-Polar and Modular Head Assembly Select the appropriate Bi-Polar Scan shell and femoral head implants and assemble components using the Bi-Polar Liner Press as illustrated in Figure A. Note: It is recommended that clean gloves are worn when handling the components prior to and during assembly. This is to avoid the accidental introduction of any contaminants such as blood to the articulating surfaces, which could affect the freedom of movement of the modular head. Figure A Ensure that the threaded bar is fully open. Place the Bi-Polar shell on the base of the liner press ensuring that the opening for the femoral head is facing upwards as illustrated in Figure B. Figure B 4

Operative Technique Place the femoral head on top of the shell, ensuring that the tapered opening is facing upwards as indicated in Figure C. Figure C Rotate the handle of the liner press in a clockwise direction until the straight proportion of the black plastic holder engages with the femoral head. Continue turning the handle to engage the femoral head with the Bi-Polar shell. An audible expulsion of air will indicate connection as illustrated in Figure D. Figure D To verify connection, unscrew the instrument partially. If the femoral head does not rotate around the Bi-Polar shell, additional compression is necessary by screwing the instrument further. Femoral head is fully inserted as indicated in Figure E Once the component is secure, remove the assembly from the instrument. Note: The holding location of the Bi-Polar shell and femoral head can be reversed by unscrewing both black plastic components and reversing their location. The above instructions still apply, when used in this configuration. Figure E Warning: In case of the patient dislocationg their hip and a closed reduction being performed, the surgeon must take care with repositioning the joint. Laboratory testing has shown that in extreme circumstances the neck of the stem can impinge against the rim of the Bi-Polar shell which may lead to dissociation of the components if excessive force is used to reduce the hip joint. 5

The Scan Bi-Polar Hip System 22mm & 28mm 6. Attachment of Bi-Polar Assembly to Femoral Component Prior to attaching this assembly to the femoral component, ensure the taper is clean and undamaged. Assembly is completed by hand pressure only. Alternatively, a combination of hand pressure and a twisting motion can be used. A Bi-Polar assembly is finally seated in position by means of a gentle tap utilising the femoral head impaction device and mallet (Figure 7). Care must be taken to ensure no damage occurs to the articulating surfaces of the Bi-Polar component as any marks or scratches on the surface will result in increased wear. 7. Reduction The Bi-Polar articulation is then finally reduced into the acetabulum and a final check on leg length and tissue tension is completed (Figure 8). figure 8 6

Operative Technique Ordering Information Scan Stainless Steel Bi-Polar Components Articulation Diameter (mm) Internal Diameter (mm) 22.22 28.0 38.0 Scan-03822-40.0 Scan-04022-42.0 Scan-04222-44.0 Scan-04422-46.0 - Scan-04628 48.0 - Scan-04828 50.0 - Scan-05028 52.0 - Scan-05228 54.0 - Scan-05428 56.0 - Scan-05628 58.0 - Scan-05828 60.0 - Scan-06028 Scan CoCrMo Modular Femoral Heads (T1) Offset (mm) Articulation Diameter (mm) 22.22 28.0-6.0 - Scan-0650-5.0 Scan-0657-0 Scan-0658 Scan-0652 +6.0 - Scan-0654 Scan Stainless Steel Bi-Polar Component Instrumentation Catalogue No. Description 31-601270 Scan Bi-Polar Modular Head Press 31-600302 Scan Bi-Polar X-Ray Templates 115% Mag 31-600325 Scan Bi-Polar Instrument Set 22.22 & 28mm comprising of: 31-600328 Stainless Steel Instrument Tray 31-600297 Trial/Gauge Bi-Polar Shell 22.22/38mm 31-600298 Trial/Gauge Bi-Polar Shell 22.22/40mm Scan Bi-Polar Instrument Set 22.22mm & 28mm 31-600299 Trial/Gauge Bi-Polar Shell 22.22/42mm 31-600300 Trial/Gauge Bi-Polar Shell 22.22/44mm 31-600228 Trial/Gauge Bi-Polar Shell 28/46mm 31-600230 Trial/Gauge Bi-Polar Shell 28/48mm 31-600232 Trial/Gauge Bi-Polar Shell 28/50mm 31-600234 Trial/Gauge Bi-Polar Shell 28/52mm 31-600236 Trial/Gauge Bi-Polar Shell 28/54mm 31-600222 Trial/Gauge Bi-Polar Shell 28/56mm 31-600238 Trial/Gauge Bi-Polar Shell 28/58mm 31-600239 Trial/Gauge Bi-Polar Shell 28/60mm 506 Judet Extractor 31-600320 Trial/Gauge handle 31-600321 Femoral Head Sizer Bi-Polar Modular Head Press 7

The Scan Bi-Polar Hip System 22mm & 28mm Notes 8

FLH 166 03.12 0459 0086 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. 01656 655221 Fax: 01656 645454