QUALITY CONTROL. Linearity Sets

Similar documents
cobas c 501 analyzer and cobas c 311 analyzer Within Run Imprecision Guidelines

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

Premium Controls for Immunochemistry

for therapeutic drug monitoring

Assays for therapeutic drug monitoring

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010

Turbidos. Design Verification. Contents

GRADING CRITERIA for CMS Regulated Analytes

Therapeutic and Critical Drug Levels

Thermo Scientific MAS Quality Control Products LabLink xl Quality Assurance Program. Simplifying. your quality controls

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

Reagents on COBAS INTEGRA Systems

Minimum Whole Blood Volumes for Microcollection Tubes for Neonates, Pediatrics, Patients less than 45 kg (100 lb) and Difficult Collections

Specimen Collection Requirements

Bio-Rad Laboratories EQAS. External Quality Assurance Services

Specimen Collection Requirements

EASY. FAST. EFFICIENT.

Controls & Calibrators Clinical Chemistry

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010

Cardiac Assessment Controls A critical element of reliable cardiac testing

Cardiac Assessment Controls

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

You will receive an Advance Shipment Notice (ASN), which reminds you of upcoming shipments and test events, before

1. Purpose 1.1. To define testing locations, schedule and order priority for each test performed in the core laboratory.

DELIVERS MORE EASY FAST EFFICIENT. Linearity and Calibration Verification PRODUCT CATALOG

Bead Chemiluminescense IMMULITE 2000, 2000 XPI & 2500

REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS

External Quality Assurance Services EQAS. Participate in an internationally recognized quality assessment program

MEMORANDUM. These reference ranges are effective immediately but sample requirements remain unchanged currently.

VITROS MicroTip Assay Summary

The power of proven technology

Excellence and confidence

Program Analyte Unit Target Limit Absolute SD %

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

RX SERIES ANALYSER OVERVIEW EXCELLENCE IN CLINICAL CHEMISTRY TESTING

CERTIFICATE OF ACCREDITATION

Thermo Scientific Konelab System Reagents For convenient and reliable analysis

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

LABORATORY NORMAL RANGES. Prepared by Date Adopted Supersedes Procedure # / Dated William T. Pope, PhD and

Types of target values, acceptable ranges

Third Party Controls for Your Dade Behring Systems

therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CLIA APPROVED PROFICIENCY TESTING PROGRAMS ACCUTEST, INC. P.O. Box 999 Westford, Massachusetts (800)

The power of proven technology

Bio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems

Proficiency Testing LABFACTS Requirements for good laboratory practice and COLA Laboratory Accreditation programs are underlined.

Carry-over Evasion List

PRODUCTS FOR EXPORT 2018

Technical Bulletin. Performance Characteristics of the BN ProSpecä System. By Liana Frances Romero, BS, MT(ASCP)

CERTIFICATE OF ACCREDITATION

OMCJH.CHEM.COLL.INF.1001 Therapeutic Drug Monitoring Guidelines

Thermo Scientific System Reagents Excellence in Clinical Chemistry

cobas h 232 POC system The power to make decisions in cardiac emergencies

RX series analyser overview

RX IMOLA A FULLY AUTOMATED CLINICAL CHEMISTRY ANALYSER, WITH A COMBINED THROUGHOUT OF 560 TESTS PER HOUR

Calibration Verification/Linearity and Instrumentation

Direct HbA1c testing capabilities on the RX modena

Authorised: JSWoodford, Lead of Speciality. Biochemistry Reference Intervals, October Page 1 of 5

IMMUNOASSAY PREMIUM - LEVEL 3 (IA PREMIUM 3)

Traceability in External Quality Assessment: How Weqas ensures traceability in EQA and stresses its importance to users. David Ducroq.

CERTIFICATE OF ACCREDITATION

Epic Labs Orderable As STAT PRIORITY As of 06/22/2016

PROFICIENCY TESTING. Clinical Laboratory Improvement Amendments (CLIA) DOs and DON Ts. Brochure # 8

Therapeutic drug monitoring. Department of Clinical Pharmacology, Wrocław Medical University

PATHOLOGY SPECIMEN TUBES QUICK REFERENCE GUIDE : Edition Expires July 2013

Bassett Healthcare Clinical Laboratory

Laboratory diagnosis of plasma proteins and plasma enzymes

Reference Manual. Performance Verification Manual. For In Vitro Diagnostic Use. This manual is intended for UniCel DxC Systems AU Systems

Trends and Challenges in Therapeutic Drug Monitoring: Is LC/MS the Solution?

The highest quality range of routine and novel reagents REAGENTS

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1)

TRENDS IN TIME. EXTERNAL EVALUATION PROGRAM FOR Immmunoassays - Chemistry

Alere Triage System. Knowing now matters when rapid treatment decisions can be made at the point-of-care.

Biochemistry Adult Reference Ranges

PROGRAM General Information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS

DEDICATED LINES LÍNEAS DEDICADAS

Laboratory Values, Critical. ThedaCare. Date Last Reviewed: 4/5/2018 Reviewing Body(s): Quality; Laboratory Leadership

NEW. Fully Automated Solution. Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA

Optimized for best performance in clinical chemistry testing

The Quidel Triage System

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL PRODUCT CATALOG

Manufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018

Reagents. Reagents. ApTT. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT Cu. ApTT Cu Hp MAU D3-HB CHE L

NORTH SHORE - LONG ISLAND JEWISH HEALTH SYSTEM LONG ISLAND JEWISH MEDICAL CENTER DEPARTMENT OF LABORATORY MEDICINE REFERENCE RANGES

Reagents. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT C ApTT Cu Hp MAU D3-HB CHE L. ApTT Cu Hp

Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment

BS-230. Clinical Chemistry Analyzer

The PATH to better cardiac care starts here

Please contact the Client Services Team if you require further information.

OHIOHEALTH Laboratory Services INPATIENT, ED AND OTHER HOSPITAL BASED PATIENT CRITICAL VALUE NOTIFICATION LIST

Therapeutic Drugs Monitoring TDM 2016 Therapeutic Drugs Monitoring Scheme Application Form

MAGLUMI 1000 MAGLUMI 1000

Transcription:

QUALITY CONTROL Linearity Sets

The new Acusera Linearity Sets have been designed with convenience in mind, helping you to easily meet CLIA requirements for calibration verification and assessment of linearity. Our liquid ready-to-use verifiers are supplied in varying levels and available in multiple configurations to meet the specific requirements of individual analyzers while challenging the complete reportable range and ultimately ensuring accurate patient testing. All linearity sets are supplied with complimentary data reduction software providing instant access to reports and real-time peer group data. In order to ensure the highest possible standards in laboratory testing CLIA has recommended that laboratories perform and document calibration verification procedures at least twice per year and/or in the event of the following; Change of reagents Instrument maintenance Poor QC results New instrument

Cardiac Combining up to six common cardiac markers in a single product, the Acusera Cardiac Linearity Sets will reduce the number of individual products required to cover your test menu. Ensure specific instrument requirements are met with the availability of dedicated solutions for both Beckman & Roche Cobas systems. A minimum of five unique levels are provided in a user-friendly, liquid ready-to-use format eliminating the need for manual dilution and significantly reducing preparation time. Solutions for Beckman analyzers CK-MB Mass Myoglobin Troponin I Cardiac Linearity Verifiers (for Beckman systems) 5 x 2 ml LV10151 CK-MB Mass D-Dimer Myoglobin NT-proBNP Troponin T hstroponin T Cardiac Linearity Verifiers (for Roche systems) 6 x 2 ml LV10150 6 levels provided 2

Specific Proteins A comprehensive range of serum proteins are available, supplied in multiple configurations designed to cover your laboratory s test menu and ensure supplier consolidation. Several unique options are available for both Beckman AU and Roche Cobas systems delivering accurate assessment of the instruments reportable range. The added advantage of a 30 day open vial stability and liquid ready-to-use format ensures availability of product for troubleshooting and maintains user convenience. Specific Proteins 1 Solutions for Beckman AU analyzers ASO Complement C3 Complement C4 CRP Ferritin IgA IgG IgM Prealbumin Transferrin Protein 1 Linearity Verifiers (for Beckman AU systems) 5 x 1.5 ml LV10147 3 Complement C3 Complement C4 IgA IgG IgM Transferrin Protein 1 Linearity Verifiers (for Roche systems) 6 x 1 ml LV10143 (6 for IgA, IgG and IgM)

Specific Proteins 2 Solutions for Beckman AU analyzers α-1-acid Glycoprotein α-1-antitrypsin β-2-microglobulin Ceruloplasmin Haptoglobin Protein 2 Linearity Verifiers (for Beckman AU systems) 5 x 1.5 ml LV10148 α-1-acid Glycoprotein α-1-antitrypsin β-2-microglobulin Ceruloplasmin Protein 2 Linearity Verifiers (for Roche systems) 5 x 1 ml LV10144 Specific Proteins 3 ASO CRP Haptoglobin Protein 3 Linearity Verifiers (for Roche systems) 6 x 1 ml LV10145 6 levels provided (5 for Haptoglobin) 4

Specific Proteins 4 Albumin Prealbumin Rheumatoid Factor Protein 4 Linearity Verifiers (for Roche systems) 6 x 1 ml LV10146 6 levels provided (5 for Rheumatoid Factor) Therapeutic Drugs The Acusera Therapeutic Drug Monitoring Linearity Sets are specifically designed for use with Beckman AU systems and are available in five unique levels spanning the instrument's reportable range. A total of 21 therapeutic drugs are covered in a single, liquid ready-to-use product eliminating the need to purchase additional material to cover your test menu while remaining easy and convenient to use. Solutions for Beckman AU analyzers Acetaminophen Amikacin Caffeine Carbamazepine Digoxin Disopyramide Ethosuximide Gentamicin Lidocaine Lithium N-Acetylprocainamide Phenobarbital Phenytoin Primidone Procainamide Quinidine Salicylate Theophylline Tobramycin Valproic Acid Vancomycin 14 day open vial stability at 2ºC to 8ºC Therapeutic Drug Monitoring Linearity Verifiers (for Beckman AU systems) 5 x 3 ml LV10149 5

Dedicated solutions are available for Roche Cobas & Beckman systems. Use the table below to determine the best solution for your lab. Beckman Roche Cobas Cardiac CK-MB Mass D-Dimer - Myoglobin NT-proBNP - Troponin I - Troponin T - hstroponin T - Specific Proteins 1 ASO - Complement C3 Complement C4 CRP - Ferritin - IgA IgG IgM Prealbumin - Transferrin Specific Proteins 2 a-1-acid Glycoprotein a-1-antitrypsin b-2-microglobulin Ceruloplasmin Haptoglobin - Specific Proteins 3 ASO - CRP - Haptoglobin - Specific Proteins 4 Albumin - Prealbumin - Rheumatoid Factor - Beckman Roche Cobas TDM Acetaminophen - Amikacin - Caffeine - Carbamazepine - Digoxin - Disopyramide - Ethosuximide - Gentamicin - Lidocaine - Lithium - N-Acetylprocainamide - Phenobarbital - Phenytoin - Primidone - Procainamide - Quinidine - Salicylate - Theophylline - Tobramycin - Valproic Acid - Vancomycin -

QUALITY CONTROL Randox Laboratories-US Ltd. 515 Industrial Boulevard, Bardane Industrial Park, Kearneysville, West Virginia, 25430, USA +1 304 728 2890 Toll Free: 866 472 6369 +1 304 728 1890 Toll Free: 866 726 3691 marketing@randox.com randoxqc.com Acusera Verify Data Reduction Software Complimentary data reduction software is supplied with all Acusera Linearity Sets. When used in combination you can effectively challenge your instrument across the complete reportable range while ultimately ensuring accurate and reliable patient testing. Online access anytime, anywhere for user convenience Intuitive user interface with simple data entry functionality Easy to interpret charts for at-a-glance performance assessment Access to peer group data for enhanced troubleshooting Expert technical support available Providing instant access to automatically generated charts, statistics and real-time peer group data, the Acusera Verify software is designed to significantly reduce the time spent analyzing data facilitating immediate laboratory decisions. If there are any issues with your Acusera Verify software please contact acuseraverifyoperations@randox.com find out more LT674USA MAR16 Information correct at time of print. Randox Laboratories Ltd is a subsidiary of Randox Holdings Limited a company registered within Northern Ireland with company number N.I. 614690. VAT Registered Number: GB 151 6827 08. Product availability may vary from country to country. Please contact your local Randox representative for information. Products may be for Research Use Only and not for use in diagnostic procedures in the USA. 8