declipse SPECT Imaging Probe Worldwide first registration-free ultrasound fusion with high-resolution 3D SPECT images

Similar documents
The Concept of GOSTT

SPECT/CT Imaging of the Sentinel Lymph Node

GOSTT General concept

Nuclear Medicine Head and Neck Region. Bán Zsuzsanna, MD University of Pécs, Department of Nuclear Medicine

The GOSTT concept. (radio)guided intraoperative Scintigraphic Tumor Targeting. Emmanuel Deshayes. GOSTT = Radioguided Surgery

Department of Nuclear Medicine with Positron Emission Tomography

THE PARATHYROID GLAND THEORY AND NUCLEAR MEDICINE PRACTICE

PARATHYROID NUCLEAR MEDICINE IMAGING REVIEW DISCLOSURES

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Ultrasonography of the Neck as an Adjunct to FNA. Nicole Massoll M.D.

LOGIQ E9 with XDclear

AACE/ACE Advanced Endocrine Neck Ultrasound Training Course 2016

Case 4: 27 yr-old woman with history of kidney stones and hyperparathyroidism.

General Nuclear Medicine

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

Handheld ProbesandMini-Cameras forintraoperative Guidanceduring Surgery

Compact Gamma Camera for Detection of Prostate Cancer

LOGIQ E9 with XDclear

42 yr old male with h/o Graves disease and prior I 131 treatment presents with hyperthyroidism and undetectable TSH. 2 hr uptake 20%, 24 hr uptake 50%

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

Molecular Imaging and Breast Cancer

Radionuclide detection of sentinel lymph node

Index. Surg Oncol Clin N Am 16 (2007) Note: Page numbers of article titles are in boldface type.

Primary hyperparathyroidism is usually a clinical and

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

Complementary sestamibi scintigraphy and ultrasound for primary hyperparathyroidism

SPECT/CT in Endocrine Diseases and Dosimetry

Hybrid Imaging SPECT/CT PET/CT PET/MRI. SNMMI Southwest Chapter Aaron C. Jessop, MD

Marcin Barczynski, 1 Aleksander Konturek, 2 Alicja Hubalewska-Dydejczyk, 2. Filip Gołkowski, 1 Stanislaw Cichon, 1 Piotr Richter, 1 Wojciech Nowak

Case 2: 30 yr-old woman with 7 yr history of recurrent kidney stones

Pioneering the future of general imaging.

SURGICAL ULTRASOUND (University Diploma)

Optical Imaging: Technology and Applications for Radiology

Molecular Imaging and Cancer

Parathyroid Imaging What is best

Primary hyperparathyroidism (HPT) has an incidence of

Intuitive. Intelligent. Innovative. General Imaging

Parathyroid Imaging: Current Concepts. Maria Gule-Monroe, M.D. Nancy Perrier, M.D.

IMAGE-GUIDED RADIATION THERAPY

Nuclear Medicine and PET. D. J. McMahon rev cewood

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Parathyroid Glands: location, condition and value of imaging tests.

Imaging in Pediatric Thyroid disorders: US and Radionuclide imaging. Deepa R Biyyam, MD Attending Pediatric Radiologist

Accurate Guidance. Confident Outcomes.

Validation of a low-cost adjustable, handheld needle guide for spine interventions

Nuclear Medicine in Oncology

The next generation of prostate care

Children's (Pediatric) Nuclear Medicine

Fusion Ultrasound: Characterization of Abdominal Masses with MR, CT, PET, and Contrast Ultrasound

3D Total Breast Ultrasound

I. Cancer staging problem

Physics of MBI (~10 slides)

FOR IMMEDIATE RELEASE

Thyroid Ultrasound for the Endocrine Surgeon: A Valuable Clinical Tool that Enhances Diagnostic and Therapeutic Outcomes

Esophageal Cancer. What is esophageal cancer?

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

Detailed Program of the second BREAST IMAGING AND INTERVENTIONS PROGRAM am am : Clinician s requirements from breast imaging

Parathyroid Imaging. A Guide to Parathyroid Surgery

Positron Emission Tomography Computed Tomography (PET/CT)

Intuitive. Intelligent. Innovative. General Imaging

Bone PET/MRI : Diagnostic yield in bone metastases and malignant primitive bone tumors

USGFNA of thyroid nodules

Elastosonography. Prof. Massimo Midiri Direttore Istituto di Radiologia Policlinico Universitario Paolo Giaccone Diagnostica per Immagini, - Palermo

Thyroid nodules 3/22/2011. Most thyroid nodules are benign. Thyroid nodules: differential diagnosis

CHARACTERIZATION OF A SMALL FIELD GAMMA CAMERA FOR THYROID SCINTISCANNING

Case 5: Thyroid cancer in 42 yr-old woman with Graves disease

Case 1: 79 yr-old woman with a lump in upper outer quadrant of left breast.

Look differently. Invenia ABUS. Automated Breast Ultrasound

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

A mixed reality application for needle targeting with trifocal stereo in real-time

CLAUDIU PEŞTEAN 1,2, ELENA BĂRBUŞ 1,2, ANDRA PICIU 3,4, MARIA IULIA LARG 1,2, ALEXANDRINA SABO 1,5, CRISTINA MOISESCU-GOIA 1,5, DOINA PICIU 6,7

Preoperative Tc-99m-sestamibi (MIBI) scintigraphy and

Outline. Parathyroid Localization Studies. Mira Milas MD, FACS Associate Professor of Surgery Director, The Thyroid Center

Austin Radiological Association Nuclear Medicine Procedure LYMPHOSCINTIGRAPHY (Tc-99m-Sulfur Colloid [Filtered])

Recent initiatives of the FANC. Michel Biernaux Health Protection Service Health and Environment Department

Thoracic Diagnostic Assessment Program. Patient information for. Last revised: November

Pushing the boundaries

Outline. SPECT/CT in Parathyroid Disease. Pathophysiology. Current guidelines. SPECT/CT the evidence. SPECT/CT in clinical scenarios

I-123 Thyroid Scintigraphy

Pushing the boundaries

Itroduction to the Nuclear Medicine: biophysics and basic principles. Zámbó Katalin Department of Nuclear Medicine

MR-US Fusion. Image-guided prostate biopsy. Richard E Fan Department of Urology Stanford University

Nuclear Sciences and Medicine

Thyroid Nodule. Disclosure. Learning Objectives P A P A P A 3/18/2014. Nothing to disclose.

A rare case of solitary toxic nodule in a 3yr old female child a case report

AN INTRODUCTION TO NUCLEAR MEDICINE

Cardiac Nuclear Medicine

LOGIQ S8 XDclear 2.0 Liver Procedures

Nuclear medicine in endocrinology

Characterization of Thyroid Nodules using Thyroid Scintigraphy

Outline. Primary Hyperparathyriodism. SPECT/CT in Parathyroid Localisation. Ann-Marie Quigley Nuclear Medicine Royal Free Hospital London

Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.

THE ROLE OF CONTEMPORARY IMAGING AND HYBRID METHODS IN THE DIAGNOSIS OF CUTANEOUS MALIGNANT MELANOMA(CMM) AND MERKEL CELL CARCINOMA (MCC)

PROPHECY. Preoperative Navigation Guides ANKLE CT SCAN PROTOCOL

NIH Public Access Author Manuscript Diagn Imaging Eur. Author manuscript; available in PMC 2014 November 10.

LOGIQ V2. Simple. Fast. Precise. Empowering Point of Care Medicine.

Breast Cancer. What is breast cancer?

Radionuclides in Medical Imaging. Danielle Wilson

LOWER EXTREMITY VENOUS COMPRESSION ULTRASOUND. CPT Stacey Good, DO Emergency Medicine Ultrasound Fellow Madigan Army Medical Center

4/22/2010. Hakan Korkmaz, MD Assoc. Prof. of Otolaryngology Ankara Dıșkapı Training Hospital-Turkey.

Transcription:

declipse SPECT Imaging Probe Worldwide first registration-free ultrasound fusion with high-resolution 3D SPECT images

high-resolution 3D SPECT live ultrasound realtime fusion of SPECT / ultrasound Hybrid imaging has opened new frontiers for Nuclear Medicine diagnostics and is displacing completely stand-alone PET and SPECT imaging. The introduction of declipse SPECT Imaging Probe as the first flexible hybrid imaging system is a further break through by making it possible to bring hybrid imaging to every single Nuclear Medicine practice. Dr. Martin Freesmeyer Head of Department of Nuclear Medicine University Hospital Jena, Germany

declipse SPECT Imaging Probe High-resolution 3D SPECT imaging: The declipse SPECT Imaging Probe is a highly sensitive handheld gamma detector combined with an optical navigation solution. By scanning around the region of interest, data is captured and used to reconstruct a high-resolution 3D SPECT image. This 3D image is overlayed on a real time video image of the patient or on an ultrasound plane. This enables an intuitive placement of the radioactive lesions/nodules in the context of anatomy and thus an improved differential diagnosis in a one-stop procedure. Handheld Imaging Probe: CZT (CdZnTe) Minimal distance to the patient 16x16 detector matrix 2.5mm x 2.5mm pixels 5% energy resolution Co-57, I-123, Tc-99m LEHR or LEHS collimator

Thyroid diagnostics application Thyroid nodules are very common. Thyroid cancer is not. We provide the best tools for thyroid cancer diagnosis to reduce the number of thyroid surgeries. Dorsal nodules: Resolve thyroid nodules unseen by planar scintigraphy. Nodules that are covered by healthy thyroid tissue or hot structures cannot be resolved in planar imaging. The depth information provided by the declipse SPECT Imaging Probe allows resolving deep structures, hidden to conventional imaging. Multinodular goiter: The high-resolution and depth information of the declipse SPECT Imaging Probe provides a precise display of radioactive distribution in the ultrasound plane. This exact matching of nodules in ultrasound and SPECT image data can help you make better decisions by seeing hot and cold areas on your live ultrasound image. SPECT US MIBI FNAC Better differential diagnosis: The accurate registration of ultrasound and SPECT images allows a better differential diagnosis of thyroid nodules. Ultrasound characteristics like shape, echo, Doppler and elastography can easily be combined with FNAC samples and metabolic information for each nodule individually. The declipse SPECT Imaging Probe can also be used for MIBI imaging. Guidance for FNAC and/or MW/HIFU ablation: The declipse SPECT Imaging Probe ultrasound fusion can help you avoid hot structures when performing FNAC and/or MW/HIFU ablation and guide you to suspicious nodules. Reference: Freesmeyer M, Opfermann T, Winkens T.: Hybrid Integration of Real-time US and Freehand SPECT: Proof of Concept in Patients with Thyroid Diseases. Radiology. 2014 Jan 16

Further applications Hyperparathyroidism: The declipse SPECT Imaging Probe system can be used for preoperative imaging as well as intraoperative navigation of hyperfunctional parathyroid glands. In addition to the conventional pre-operative ultrasound examination the fusion of ultrasound and SPECT images can contribute to the differential diagnosis for cases where ultrasound and scintigraphy alone are not conclusive. Furthermore the declipse SPECT Imaging Probe can provide a precise localization in the context of anatomy during surgery. This is particular useful in secondary surgeries and in case of ectopic glands. intraoperative guidance Sentinel lymph node biopsy: The augmentation of the declipse SPECT Imaging Probe high-resolution images on ultrasound enables both detailed analysis of the sentinel nodes or an ultrasoundguided needle biopsy. Sentinel lymph nodes can also be imaged in real-time using the live 2D image provided by the handeld imaging probe. Moreover the system can be exended to the full functionality of the declipse SPECT Open Surgery system providing depth measurements and navigation during surgery. preoperative US fusion

Features to support your routine: High-resolution 3D SPECT images: Due to its freehand nature the declipse SPECT Imaging Probe is capable of scanning directly on the surface which results in an increase in image resolution. Registration-free ultrasound fusion: By construction, calibration, and external referencing the SPECT image generated by declipse SPECT Imaging Probe is coregistered and overlaid on the ultrasound plane without any interaction of the user. Real-time augmentation on video camera: For intuitive orientation, the projection of SPECT image is overlaid on a live video image of the patient featuring augmented reality visualization.

Navigation and depth measurements: The hybrid 3D imaging features metric measurements in the dataset and localization of structures in 3D. Live 2D image: Anytime during the SPECT and ultrasound procedures you can view the live 2D image of the handeld gamma detector. Loading of preoperative SPECT/CT and PET/CT data: Existing datasets can be loaded and compared as well as registered for visualization, localization and bedside interpretation using the navigation features.

Beyond Molecular Imaging SurgicEye GmbH Friedenstrasse 18a 81671 Munich Germany info@surgiceye.com Phone +49 89 549 9890 00 Fax +49 89 549 9890 90 declipse SPECT Imaging Probe is developed and manufactured in Munich, Germany by SurgicEye GmbH www.surgiceye.com SurgicEye, declipse and declipsespect are registered trademarks of SurgicEye GmbH in the EU and US Recommendations of this flyer are subject to be validated by the user with your national guidelines SE 6009 - EN 01 Printed in Germany