Pollen Slide Mounting Protocol

Similar documents
HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

Protn-Latex. For Determination of Protein in Latex. (Cat. # Latex, Latex) think proteins! think G-Biosciences

How to Use ENBREL : Vial Adapter Method

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

Biochemical Analysis of Plant Enzymes

Lilly. Disposable Insulin Delivery Device User Manual

BIL Mechanisms of Mitosis PART III. Collecting Data

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

Exploring Mitosis Lab IMPORTANT LEARNING OBJECTIVES INTRODUCTION cell cycle interphase division (mitosis)

Rhino Clear Sprint Atomizer

Mixing Two Insulins. Getting Ready. What to Do

Giving Medicine by Subcutaneous Injection

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

MICAFUNGIN MIXING

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

Core practical 4: Investigate the effect of sucrose concentration on pollen tube growth

Inspection Window. Syringe Body

Items in the package:

EduCare Knowledge & Skill Assessment Medication I Routes

IMPORTANT: PLEASE READ. Don t

OBSERVING LIVING CELLS

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

A step-by-step preparation guide

PLEASE READ THIS USER MANUAL BEFORE USE

Exploring Mitosis Lab IMPORTANT LEARNING OBJECTIVES INTRODUCTION

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

Core practical 14: Investigate the effect of gibberellin on the production of amylase in germinating cereals using a starch agar assay

Skin Scrape. Year Group: BVSc4 + Document number: CSL_D16

MYALEPT (MAI-uh-lept) (metreleptin) for injection for subcutaneous use

Cap Clip Rubber Seal Plunger Pen Body Dose Window

A step-by-step preparation guide

INSULIN INJECTION KNOW-HOW

Patient Education Pharmacy Services

Fuji ORTHO LC CAPSULE. 1 Capsule = 1 Full Arch Bonded

Instructions for Use. Welcome!

Vial. A healthcare provider should show you how to inject MYALEPT before you use it for

Lab 6: Cellular Respiration

Instructions for Use. For use with. 10 mg vial

Administering Intravenous Medication By Syringe Pump

Biol110L-Cell Biology Lab Spring Quarter 2012 Module 1-4 Friday April 13, 2012 (Start promptly; work fast; the protocols take ~4 h)

Insulin Basic facts. Patient Education Patient Care Services. What is insulin? What types of insulin are there? Basal Insulin

Instruction Guide. Today is the day you change the way you live with dentures. How to Apply DenSureFit Soft Silicone Reline Material

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health

INSTRUCTIONS FOR USE. Norditropin NordiFlex Somatropin (rdna origin) injection 30 mg/3 ml Prefilled Pen

RLI Mouse Vitrification Media Kit

Instructions for Use. HUMALOG KwikPen. insulin lispro injection (rdna origin) 100 units/ml, 3 ml pen

Preparing and Administering Medications Using ENFit : Procedure for Inpatient Settings

Instructions for Use Enbrel (en-brel) (etanercept) Single-use Prefilled SureClick Autoinjector

I can show you how I give my. child insulin

Acknowledgement goes to WHO for use of their hand washing technique

NovoPen Echo User guide

CRYOTOP SAFETY KIT Protocol. Cryotop Method

Experimental Procedure

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Module 4: Effect of Alcohol on Worms

Administering Intravenous Medication By Slow IV Push

TEACHER/LECTURER GUIDE

THE CASE OF THE DRUNK DRIVER; GC APPROACH From Science in Motion, Juniata College

HOW TO USE... 5mg. Pocket Guide

Patient/Carer instructions for the administration of Subcutaneous Cytarabine

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

For use only with INSTRUCTIONS FOR USE

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Syringe (75 mg/ml)

HUMULIN 70/30 KwikPen

CIMZIA (certolizumab pegol)

Instructions for Use. BASAGLAR KwikPen. insulin glargine injection (100 units/ml, 3 ml pen)

PLEASE READ THESE INSTRUCTIONS BEFORE USE

Experiment 9 Amino Acids and Proteins

Giving Yourself an Emergency Injection Using Solu-Cortef Act-O-Vial 1/8

Tips for Training New Customers

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

Fibrlok II 2529 Universal Optical Fiber Splice

BLOOD CULTURE SPECIMEN COLLECTION. Skills: 40 points. Objectives:

Burping Yeast: An Investigation of Cellular Respiration

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Catalytic Activity of Enzymes

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

APPENDIX 1 PROCEDURES FOR ADMINISTERING MEDICATION

TJF-160F/VF Cleaning and Disinfection Checklist

1 Before You Begin. Injection Instructions. Safety Tips. Disposing of Used Syringes, Needles, and Supplies. Having Someone Help You With Injections

`bob`=å~ãéê~=ó=å~êéi=åäé~åáåöi= ÇáëáåÑÉÅíáçå=~åÇ=ëíÉêáäáò~íáçå

Tips for Successful Venipuncture

WiCell Neural Stem Cell Protocols

2. Now that you have made your hypothesis, you will begin. must perform at least 3 trials. Pleasee complete

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

How to Change a. Foley catheter. Patient Education Rehabilitation Nursing. Step-by-step instructions for the caregiver

MOTH DISSECTION GUIDE

Before you use the TALTZ autoinjector, read and carefully follow all the step-by-step instructions.

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

Ribbon Splitting Tool (RST-000)

Transcription:

Pollen Slide Mounting Protocol Materials: Syn-Matrix mounting medium Microcentrifuge Microscope slides Slide coverslips (18mm x 18mm) Coverslip podium (see Figure 1) Capillary tubes Dissecting microscope Petri dish DI water bottle Kim wipes 250 ml waste beaker Permanent marker Light microscope Labels Trays for transportation Slide boxes Processed samples Figure 1: Coverslip podium Note: To make glass tools from capillary tubes, melt the tube into 1 of the 2 following formations: Round-tip tool: This tool can be formed by placing the end of a capillary tube into an open flame. By gently turning the tool, a bulbous end will start to form (see Figure 2A). Ensure the glass closes completely before removing it from the flame. Allow the tool to cool completely before use. Needle-tip tool: This tool can be formed by placing the middle of a capillary tube over an open flame and slowly pulling the two ends apart. The result will be a long, thin glass section that resembles a tip of a needle (see Figure 2B). Allow the tool to cool completely before use. Figure 2A: Round- tip glass tool Figure 2B: Needle- tip glass tool 1

Pre-mount Preparation: 1. Retrieve the Syn- Matrix mounting medium from the refrigerator. Store the Syn- Matrix in the refrigerator when not in use to prevent the denaturing of the medium. 2. Place the first 6 samples in the microcentrifuge and ensure the samples are balanced within the device (see Figure 3). If they are not balanced, add ethanol to the samples until all of the samples contain the same amount. Also make sure all of the caps are placed into the machine in the same orientation. Figure 3: Tubes in microcentrifuge Caution: Never run the centrifuge if it is unbalanced. It may cause damage to the machine or samples. 3. Close the lid and allow the microcentrifuge to run at full speed for 10-20 seconds. 4. While the microcentrifuge is running, place a coverslip on an elevated podium (see Figure 4). 5. Place a petri dish upside down on the stage of the dissecting microscope to obtain a better viewing distance (see Figure 5). 6. Let the device stop completely before opening the lid. The pollen should be concentrated at the bottom of the tube. If it is not, the samples may be centrifuged again for a longer period of time. Figure 4: Coverslip on podium Figure 5: Petri dish on dissecting scope stage 2

Mounting Samples: Note 1: Once the Syn-Matrix is placed on the slide, there is only 45 seconds or less to mount the pollen and place the coverslip onto the slide before the medium dries. Work quickly, or unwanted bubbles will form distorting the image of the pollen. Note 2: Bubbles may form for two reasons: Reason 1 - The Syn-Matrix has begun to dry before the coverslip is placed. For the best quality, do not wait too long to place the coverslip on the slide, even if working to remove debris. If bubbles form during the drying of the Syn- Matrix, use the non-writing end of a pen to gently press the coverslip down to remove the largest bubbles. Only press on the areas of the coverslip that do not have Syn-Matrix to prevent crushing any pollen grains. Some bubbles may not come out; do not over-press the slides. Reason 2 - Ethanol has accompanied the pollen grains onto the Syn- Matrix causing a reaction. To prevent bubbles caused by the ethanol reaction, avoid gathering drops of ethanol from the tubes whenever possible. Allow the sample to sit a few extra seconds when possible before placing the coverslip to allow the ethanol to evaporate. If large amounts of ethanol appear to be clouding the sample, check to ensure that the tool is fully formed and is not drawing in excess ethanol when dipping in the sample. Spreading the Syn- Matrix to areas affected by ethanol- matrix reactions will help lessen the effect. Note 3: While spreading the pollen grains, attempt to place some in polar view, and some in equatorial view so that the species can be fully described at a later time. As previously stated, tapping or pressing too hard on the slide can cause it to move or crush the grains. Be gentle! 1. Hold a clean microscope slide by the edges, and place a small amount of Syn- Matrix in the middle of the slide (see Figure 6). An ideal size would be about 0.5cm in diameter, 0.1cm in height. 2. Place the slide, matrix-side up, under the dissecting microscope. Focus on Figure 6: Syn-Matrix drop on slide the drop of Syn-Matrix. 3. Roll the round-tip glass tool in the Syn-Matrix gently to spread the medium slightly and to coat the tool in the medium. 4. Open the lid of the sample and insert the round-tip tool, now coated in Syn- Matrix, carefully into the tube. Gently gather the pollen grains at the bottom of the tube. Do not touch the sides of the tube as you remove the tool. 5. Dab the Syn-Matrix on the microscope slide with the tip of the rounded tool, removing the pollen attached to it. Roll the tool in the Syn-Matrix to remove the pollen grains stuck to the tip. 3

6. Use the tool to gently spread out the pollen grains so that they are not clumped. This can be done using a circular motion to draw the grains apart and spread them within the medium. Avoid over-spreading the Syn-matrix to prevent rapid drying and crushing grains during the coverslip mounting process. 7. Remove any unwanted debris from the sample by scooping it out using the needle-tip glass tool, only if time permits. 8. Mount the coverslip to the microscope slide by either gently placing the microscope slide (Syn-Matrix side down) onto the elevated coverslip on the podium, or place the coverslip onto the slide by hand by gently guiding the coverslip over the medium. Post-Mounting: Note 1: Ideally, five slides should be mounted for each sample. For samples with low pollen availability, mount as many slides as possible before the sample runs out. Note 2: If pollen is not present in the sample from the start, two slides should be mounted before moving on to the next sample. Slide Labeling and Storage Process 1. Place the label for the sample on the left side of the coverslip (see Figure 7). 2. Observe the slide under a light microscope to determine its quality and amount of pollen. DO NOT view the slide at a magnification greater than 63x for at least two days. 3. Mark the slide in the upper right-hand corner with the following codes, should they apply: Figure 7: Labeled slide a. C - contamination of another species is found on the slide and totals >30% of the pollen present. b. NP - no pollen is present on the slide. c. Number between 1 and 10 - the number of pollen grains present on the slide of the expected species. d. Do not mark the slide if it does not display any of the above characteristics. 4. Use DI water to rinse any glass tools used during the process thoroughly. Wipe the tools completely dry using a Kim wipe, and ensure the tips are clean before moving on to the next sample to prevent contamination. The glass tools are fragile; handle and clean them with care. If a tool breaks, it should be placed in the broken glass disposal container. 4

5. Place the slides on a level surface to prevent the Syn-Matrix from expanding in one direction (see Figure 8). Slides should not be placed upright, stacked, immersed in oil or observed at 100x magnification for at least two days after mounting to allow the Syn-Matrix to fully dry. 6. Record the date each sample is mounted on the log sheet to prevent accidental movement, description or storage before the Syn-Matrix has fully solidified. 7. Allow the samples to dry for a minimum of 48 hours. The slides can then be moved into the slide storage boxes. They are now ready to be viewed under oil immersion and at 100x magnification (Figure 9). Figure 8: Slides on level tray Figure 9: Slide storage box 5