CS 2.0. Product information. Intelligent innovations for a better life.

Similar documents
CS 2.0. Product information. Intelligent innovations for a better life. Presented by: Syntellix AG Schiffgraben Hannover Germany

CS 2.7. Product information. Intelligent innovations for a better life. Presented by: Syntellix AG Aegidientorplatz 2a Hannover Germany

Compression Screw 3.2 Bioabsorbable. Product information

A NEW STANDARD OF IMPLANTS!

Syntellix AG MAGNEZIX CS /3.2 Product information. Intelligent innovations for a better life.

THE IMPLANT OF TOMORROW SPECIAL PROPERTIES UNIQUE BENEFITS: MAGNEZIX

STABLE, TRANSFORMABLE, UNIVERSALLY APPLICABLE

STABILITY WITHOUT COMPROMISES MAGNEZIX PIN: AT FIRST METAL THEN BONE

Distal Ulnar Locking Plate

Headless Compession Screw 2.5 / 3.0

RapidSorb Resorbable Tacks. Resorbable Fixation System.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Distal Radius Plate 2.4/2.7 dorsal and volar

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

NCB Distal Femur System. Surgical Technique

low ProfIle neuro PlaTIng system

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

MetaFix Ludloff Plate

Elbow Plating System Surgical Technique

Low Profile Neuro Plating System. Surgical Technique

Lapidus Arthrodesis System Instructions for Use

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

SMV Scientific Bone Plate and Screw System Surgical Technique

IT HELPS YOU GET FIT AGAIN, FASTER AND SAFER

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Aesculap Orthopaedics Targon DR

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

MatrixNEURO. The next generation cranial plating system.

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

TSLP Thoracolumbar Spine Locking Plate

LCP Metaphyseal Plates. For extra-articular fractures.

3.0/3.5/4.0/4.5/6.5/7.0/7.3. Cannulated Screws. Surgical Technique

SpeedTip CCS 2.2, 3.0

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System.

LCP Distal Humerus Plates

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

ORION Screw System PRODUCT INFORMATION

Instrument and Implant for wrist fracture

LCP Distal Tibia Plate

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

3.5 mm LCP Extra-articular Distal Humerus Plate

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

PROXIMAL TIBIAL PLATE

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Technique Guide. 6.5 mm Midfoot Fusion Bolt. For intramedullary fixation of the medial column of the foot.

Low Bend Distal Tibia Plates

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Locking Compression Technology by aap

Complex process High costs

Olecranon Locking Plate II

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

3.5 mm LCP Olecranon Plates

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

Correction System. Surgical Technique

Small Fragment Plating System. Securing optimal fixation through locked and compression plating technology

Small Fragment Plating System

WINSTA-C. Clavicle Plating System

Flower Medium Headless & Cannulated Screws

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Technique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium.

Technique Guide. PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

Clavicle Hook Locking Plate

PEDUS-L. Locking Plantar Lapidus Plate

Small Fragment Locking Compression Plate (LCP ) System

ALIANS ELBOW & OLECRANON. INNOVATION means MOTION. Distal humerus and olecranon plating system Polyaxial locking technology Precontoured implants

AxSOS Locking Plate System

SURGICAL TECHNIQUE GUIDE: JONES FRACTURE USING THE PRECISION JONES FRACTURE SCREW SYSTEM

WINSTA-R. Distal Radius System

Zimmer Anterior Buttress Plate System. Surgical Technique

VariAx Compression Plating System. Operative technique

Complex process High costs

Femur Condylar Plate System Procedural Steps.

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

Surgical Technique. Distal Humerus Locking Plate

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones.

Distal Radius Sterile Kit. Optimization And Efficiency You Can Rely On

UNDERSTANDING INNOVATIONS A CLOSER LOOK AT THE SPECIAL PROPERTIES OF MAGNEZIX

4.5 mm LCP Medial Proximal Tibia Plates

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Table of Contents.

Biomimetic Product catalogue

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

2.7 mm/3.5 mm LCP Distal Fibula Plate

Surgical Technique. Olecranon Locking Plate

VA-LCP Olecranon Plates 2.7/3.5. The fracture-specific low-profile fixation system with variable angle locking technology.

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

Transcription:

CS 2.0 Product information Intelligent innovations for a better life.

02. 03 Syntellix AG MAGNEZIX Compression Screw 2.0 Introduction CAUTION This product description is not sufficient or adequate to allow immediate use of the instruments and the implant described. Instruction must be given by authorized personnel prior to use of these instruments and implants! Since the implants are designed for single use only, reuse of MAGNEZIX implant devices is grossly negligent and can result in an increased risk of infection and loss in implant stability. In general, re-sterilization alters the implant s functionality in an unpredictable way. In the case of concurrent use of third party implants it must borne in mind that steel, titanium and cobalt-chromium alloys may not remain in direct contact with a MAGNEZIX implant at the intervention site (i.e. no physical contact of implants). The image shown on the cover is a CAD image. The actual implant may differ in appearance.

INTRODUCTION...................................................04 THE MATERIAL MAGNEZIX........................................................................04 INTENDED USE...................................................................................06 INDICATIONS.....................................................................................06 CONTRAINDICATIONS.............................................................................06 WARNINGS......................................................................................06 ADVANTAGES AND FEATURES...................................................08 SURGICAL TECHNIQUE..............................10 PRODUCT OVERVIEW....................................16 IMPLANTS.......................................................................................16 INSTRUMENTS...................................................................................17

04. 05 Syntellix AG MAGNEZIX Compression Screw 2.0 Introduction MAGNEZIX THE MATERIAL MAGNEZIX MAGNEZIX is the name given to the world s first bioabsorbable implant material: it is a metallic alloy that has a CE Mark approval for medical applications within Europe. MAGNEZIX is a magnesium-based alloy with the properties of a metal but which is nonetheless fully absorbable in the body where it is replaced by body-own tissue. The biomechanical properties of MAGNEZIX are very similar to those of human bone. Some studies have also demonstrated that magnesium alloys have osteoconductive properties. 1 Advantages for users and patients Î Complete bioabsorption of the implant makes later removal of the product obsolete. Î The mechanical properties are significantly better than those of conventional resorbable implants. Î The implant is completely and homogenously transformed into body-own tissue. Î Histological investigations show bone formation at the implant s surface and bone growth into previously bioabsorbed implant sites. Î The use of MAGNEZIX implants does not lead to so-called stress shielding (bone degradation) due to bone-like biomechanical properties. Î In terms of applicability, MAGNEZIX implants hardly differ from conventional implants made of steel or titanium. This is ensured by the adapted design, which takes the material and bioabsorbable properties into account. Î MAGNEZIX implants are visible radiographically, MR conditional and do cause marginal artifacts only (please refer to the Instructions for Use). 1 Revell et al. (2004) The effect of magnesium ions on bone bonding to hydroxyapatite coating on titaniumalloy implants. Key Eng Mater Vol. 254-256, 447-50. Liu et al. (1988) Magnesium directly stimulates osteoblast proliferation. J Bone Miner Res (3), 104. Zreiqat et al. (2002) Mechanisms of magnesium-stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants. J Biomed Mater Res 62 (2), 175-84.

Figure left: Histological evaluations in an animal study verified full and complete transformation of the metallic implant after a 12-month implant period. Studies demonstrated new bone formation with direct implant contact and presence of osteoblasts and osteoclasts. Orthopädische Klinik der MHH SAGE Publications Ltd. All rights reserved. Waizy H, Diekmann J, Weizbauer A et al. (2014) In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months. J Biomater Appl 28 (5), 667-75.

06. 07 Syntellix AG MAGNEZIX Compression Screw 2.0 Introduction INTENDED USE CONTRAINDICATIONS MAGNEZIX CS bioabsorbable compression screws serve the purpose of re-establishing bone continuity after fractures and osteotomies (osteosynthesis) as well as for treatment of pseudarthroses (re-osteotomies). The objective when using the MAGNEZIX CS device is specifically anatomic retention by way of surgical splinting of assembled bone fractions after prior repositioning until bony healing. The implants are designed for single use only. INDICATIONS The indications for MAGNEZIX CS implants are reconstructive procedures after fractures, malpositions and/or other pathological bone alterations of the human skeleton. The surgeon must in all cases determine the extent of the injuries or the bony alterations and the scope of the necessary surgical intervention and select the appropriate operating procedure and the appropriate implant. This applies in particular when using bioabsorbable MAGNEZIX implants. The surgeon is always responsible for the decision to use the implant. According to its respective dimension, MAGNEZIX CS can be used for adaption- and exercise-stable fixation of bones and bone fragments in children, adolescents and adult persons. Relevant medical literature and guidelines must be observed when determining the dimensions of screws to be used. The MAGNEZIX CS 2.0 is for example suitable for the following: Î Intra-articular and extra-articular fractures of small bones and bony fragments Î Arthrodeses, osteotomies and pseudarthroses of small bones and joints Î Small bony avulsions of ligaments and tendons Including: Î Phalanges, metacarpalia Î Processus styloideus radii et ulnae Î Capitulum and caput radii Î Osteochondrosis dissecans In specific clinical situations the use of MAGNEZIX implants may be prohibited (absolute contraindication) or use may be planned subject to certain considerations (relative contraindication). Absolute contraindications Î Insufficient bone substance to anchor the implant Î Evidence or suspicion of septic-infectious operating area Î Known allergies and/or known foreign body reactions Î Application in the area of the epiphyseal plates Î Load-stable osteosyntheses Î Arthrodeses of medium-sized and large joints Î Use in the spinal column Relative contraindications Î Options for conservative treatment Î Acute sepsis Î Osteoporosis Î Alcohol and/or drug misuse Î Epilepsy Î Limited skin/soft tissue conditions Î Non co-operative patient or limited mental state of patient Î No possibility for providing adequate post-operative follow-up (e.g. temporary load relief) WARNINGS In the case of concurrent use of third party implants it must borne in mind that steel, titanium and cobalt-chromium alloys may not remain in direct contact with a MAGNEZIX implant at the intervention site (i.e. no physical contact of implants). Since the implants are designed for single use only, reuse of MAGNEZIX implant devices is grossly negligent and can result in an increased risk of infection and loss in implant stability. In general, resterilization alters the implant s functionality in an unpredictable way.

Syntellix AG MAGNEZIX Compression Screw 2.0 08. 09 Advantages and Features ADVANTAGES AND FEATURES BIOABSORBABLE MAGNESIUM ALLOY The use of MAGNEZIX makes subsequent removal of the implant obsolete: furthermore MAGNEZIX promotes the bone healing process. MAG- NEZIX is bioabsorbable, biocompatible and non-toxic in a biological environment. The use of the innovative bioabsorbable MAGNEZIX metal alloy allows the screw to be implanted using standard techniques. Self-tapping screw tip The self-tapping properties of the screw tip reduce the operation time and simplify the surgical application technique. Self-tapping head thread The self-tapping design of the screw head simplifies insertion and countersinking of the screw head. Different thread pitches The threads of the head and the shaft have different thread pitches. This adapted design of the screw generates compressive forces and supports the intended interfragmentary compression. Self-holding screwdriver The head of the screw is of T4 (ISO 10664-4) design. The advantages of this ISO standardized technology are: Î Enlarged contact area Î Improved self-retaining mechanism Î Improved torque transmission

Syntellix AG MAGNEZIX Compression Screw 2.0 10. 11 Surgical Technique SURGICAL TECHNIQUE SURGICAL TECHNIQUE MAGNEZIX CS STEP BY STEP Prior to implanting a MAGNEZIX CS 2.0 screw it is necessary to ensure repositioning and temporary stabilization of the fracture or the osteotomy. Although the MAGNEZIX CS 2.0 screw has a self-cutting tip, a pilot hole must always be predrilled. The pilot hole also allows precise selection of the correct screw length. Step 1: Drilling the pilot hole Position the double drill guide through the soft tissue to the bone. Insert the drill bit through the double drill guide and into the bone, possibly monitoring with the image intensifier until it is at the required depth. Important If no pilot hole is drilled, the precise screw length cannot be correctly determined. Pre-drilling with an incorrect alignment can lead to malfunction of the screw. Instruments used: ➀ 9020.033 Double Drill Guide, Ø 2.2/1.5 mm ➀ 9020.020 Drill Bit, Ø 1.5 mm Step 2: Determination of screw length The length of the screw is determined by means of the depth gauge to determine the depth of the pre-drilled pilot hole in the bone. (18 mm in the figure). Important When selecting the length of the screw one has to ensure proper compression of the fracture gap. Instruments used: ➂ 9020.042 Depth gauge for screws

➁ ➀ STEP 1 ➂ STEP 2

Syntellix AG MAGNEZIX Compression Screw 2.0 12. 13 Surgical Technique Step 3: Countersinking In order to simplify insertion of the screw head the head-side of the intended implant position is now reamed using the countersink. Important If the screw is positioned perpendicular to the bone surface, countersinking to the first ring marking (RM 1) is required in order to achieve adequate countersinking of the screw head. If the screw is positioned at an angle of 45 to the bone surface, countersinking to the second ring marking (RM 2) is required in order to achieve adequate countersinking of the screw head. Instruments used: ➀ 9020.033 Double Drill Guide, Ø 2.2/1.5 mm ➁ 9020.021 Countersink Ø 2.2/1.5 mm, for quick coupling

➁ STEP 3 ➀ RM 2 RM 1 0 ➁ RM 2 ➀ 45

Syntellix AG MAGNEZIX Compression Screw 2.0 14. 15 Surgical Technique Step 4: Inserting the screw The MAGNEZIX Compression Screw 2.0 of the previously determined length (step 2) is now screwed into place. Important Bear in mind that the shaft thread could pull out of the distal bone fragment if the induced compression forces when screwing-in the screw are excessive. If the selected screw is too short the shaft thread might cross the fracture or osteotomy gap. If this situation results no compression will be generated. Therefore, to ensure the correct position of the threaded shaft it is recommended to check the position using an image intensifier. If one finds the thread crossing the fracture or osteotomy gap the screw must be removed and a longer screw has to be selected in order to generate compression. When doing this and in the case of a hard (dense) bone situation, it might be necessary to repeat the pre-drilling process as described in step 1 to further deepen the pre-drilled pilot hole for the selected screw with an adequate length. Instruments used ➀ 6020.104 Screwdriver T4, One-Piece Handle Optional 6020.204 Screwdriver T4, Multi-Part Handle

STEP 4 ➀

Syntellix AG MAGNEZIX Compression Screw 2.0 16. 17 Product Overview MAGNEZIX CS 2.0 IMPLANTS Art. No. Threaded shaft length Screw length [mm] SG [mm] L 1020.008 4 8 3.0 mm SG L 1020.010 4 10 1020.012 4 12 1020.014 5 14 Ø 2.5 mm Head thread 1020.016 5 16 1020.018 5 18 1020.020 6 20 Ø 1.6 mm Shaft diameter 1020.022 6 22 Ø 2.0 mm Shaft thread 1020.024 6 24 All implants are individually sterile packaged. It is not possible to re-sterilize the implants.

MAGNEZIX CS 2.0 INSTRUMENTS* Art. No. Description 6020.104 Screwdriver T4, One-Piece Handle, consisting of: 9099.001 One-Piece Handle for Screwdriver 9020.015 Screwdriver Blade T4 6020.204 Screwdriver T4, Multi-Part Handle, consisting of: 9099.002 Multi-Part Handle for Screwdriver 9020.015 Screwdriver Blade T4 9020.020 Drill Bit Ø 1.5 mm, length 88/63 mm, for quick coupling 9020.021 Countersink Ø 2.2/1.5 mm, for quick coupling 9020.033 Double Drill Guide, Ø 2.2/1.5 mm 9020.042 Depth gauge for screws *The figures are not to scale. Not shown: 8020.001 Sterilizing Tray for MAGNEZIX CS Ø 2.0 mm, without contents 8020.002 Lid for Sterilizing Tray, for MAGNEZIX CS Ø 2.0 mm

METALLIC AND BIOABSORBABLE. A MEDICAL SENSATION. MAGNEZIX

Presented by: Syntellix AG Schiffgraben 11 30159 Hannover Germany T +49 511 270 413 50 F +49 511 270 413 79 info@syntellix.com www.syntellix.com Implants are manufactured in Germany in cooperation with Königsee Implantate GmbH. 0197 7020.001.001 09/15