D.T. LIGHT-POST. Bisco. Instructions for Use. Radiopaque Translucent Fiber Post System. Double Taper

Similar documents
D.T. LIGHT-POST. Instructions for Use. Bisco 0459 D.T. LIGHT-POST X-RO. Radiopaque Translucent Fiber Post System ILLUSION

Bisco D.T. LIGHT-POST X-RO ILLUSION

Flexi-Flange Fiber. Instruction Book for Flexi-Flange Fiber Posts IMPORTANT: Read pages 7 through 12 for Technique first. ESSENTIAL DENTAL SYSTEMS

R.A.P.T.O.R. SYSTEM. Bisco. Instructions for Use. Composite/Porcelain Finishing Burs. U.S. Patent: 5,779,476

ÆLITE Composites. Bisco. Instructions for Use. Light- Cured. U.S. Patent: 6,709,271

RESINOMER Dual- Bisco. Instructions for Use. Cured Amalgam Bonding/Luting System

PRO-V IDS Kit. Bisco. Instructions for Use. Provisional Restorative System

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer

ACE ALL-BOND TE. Bisco CE Universal Dental Adhesive System. Dual- Cured

DUO-LINK UNIVERSAL KIT

Bisco UNIVERSAL PRIMER

ALL-BOND 2. Bisco. Instructions for Use. Universal Dental Adhesive

Dowel restorations Treatment with a post and core

INSTRUCTIONS FOR USE AND CARE

RESTORATIONS IN ENDODONTIC. Epita S. Pane Cons Dept FKG USU

S5 Rotary Files. only. Manufacturer. Packing unit. Batch code. For professional use only (0)

ProUltra ULTRASONIC SURGICAL TIPS

Table of Contents. Flexi-Overdenture Characteristics

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

Instructions For Use

Tools for Endodontic Success

ProUltra Ultrasonic Non Surgical Endo Tips

A new technique for preprosthetic restorations.

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

1) INDICATIONS FOR USE These products have to be used only in hospital environments, clinics or dental offices by qualified dental personnel.

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

Classic Technique Guide

Unique. Patented. Tapered. Customizable. PEERLESS.

Directions For Use. Zirconia. Minimum occlusal wall thickness: 0.5 mm, including a 0.1 mm reserve for occlusal adjustment

A great file. Even better.

Device Technical File

More than 50 Years of Innovation and Clinical Success

2. Gap closure and replacement of the missing tooth 35 with directly modelled bridge region 34-36

Case Note Retrieval of a separated file using Masserann technique: A case report

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

Peak. Universal Bond Light Cure Adhesive with Chlorhexidine. With its versatile formulation, Peak Universal Bond is the only adhesive you need.

BS EN ISO 14971: Risk Analysis and Risk Management Report

CDR Positioning System User Guide

Bone Preservation Stem

LuxaCoreZ. Core build-ups and post cementation.

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

Endodontics. Patented partial heat treatment Improved safety

Innovative revolutionary approach to root canal preparation

Obturation System of Endodontics

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

PROPORTION GAUGE T-BAR TIP

tomas - Anchorage System

Survey on Knowledge about Access Cavity Preparation

Field Guide to the Ultrasonic Revolution

High-end solution STEP-BY-STEP USER GUIDE

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Note: The short arm of the BLPG tip is of the same length and measurement as the long arm of the T-bar and the Inline tip.

Core build-up using post systems

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Protemp Crown Temporization Material

Treatment Options for the Compromised Tooth

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com

Root Canal Treatment. with a mechanical treatment system. Clinical case

5 Days Comprehensive Endodontic Course Topics

PLATE 1. Outline Form

Patient s Presenting Complaint V.C. presented with discomfort and mobility from the crowned maxillary left central incisor tooth. Fig 1.

RESTORING ENDODONTICALLY TREATED TEETH POST RESTORATIONS CROWNS. Dr. Szabó Enikő associate professor

BEGO PMMA Multicolor Processing information for CAD/CAM-produced restorations

Root canal therapy. Phase 1: Relief of pain

2011 Dental Materials Clinical Dentistry Survey

Midwest E Motor. Directions For Use. Doc. No

CERASMART. The new leader in hybrid ceramic blocks

Advanced ESX Instrumentation:! Segmental Crown Down & Hybridization of Tapers!

Approach Patients with Confidence

Used Products. Multilink Automix. OptraDam. Total Etch. Monobond Plus. MultiCore. TOOTH - Root post - Fiber-reinforced composite - Multilink Automix

Araldite Advanced Materials. Two component toughened methacrylate adhesive system. Structural Adhesives TECHNICAL DATASHEET

Metal-Free Restorations PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS D I D I E R D I E T S C H I. For.

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Syllabus for International Dental Assistants. Prepare and maintain the dental surgery, instruments, and equipment for clinical dental procedures

Shades: A1, A2, A3, A3.5, A4, B1, B2, B3, C2, C3, C4, D3, DB, OA2, OA3, OA3.5, OB2, Incisal, SL,SLO, SLT, YB

Endo Easy Efficient one file endo

CERASMART for PlanMill

Safety and Simplicity!

Race family Endodontic NiTi rotary files

QuickPro. Instructions for use

Preparation Instructions for the CAMLOG /CONELOG Implant System

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

Endo Easy Efficient. The efficient NiTi system. User Information.

Preparation and making fillings Class V., III., IV.

Treatment Options for the Compromised Tooth: A Decision Guide

Concept of Simultaneous Crown-Root Shielding in Endodontics

ANATOMIC. XP-endo Finisher. optimal cleaning while preserving dentine

Fiber post reconstruction: fast and furious style

Integra Flowable Wound Matrix

Instructions for Use for dental implant

Periapical Radiography

Our special deals spring & summer. valid until 31st of July vdw-dental.com

LOCATOR ROOT ATTACHMENT SYSTEM

502 Jefferson Highway N. Champlin, MN Saving Your Teeth with ROOT CANAL THERAPY

Dental material for filling the root canals "AUREOSEAL M.T.A."

Single Use Curlew TM Multiple Biopsy Forceps

Our special deals spring & summer. valid until 31st of July vdw-dental.com

Transcription:

Bisco D.T. LIGHT-POST Double Taper 0459 Radiopaque Translucent Fiber Post System Instructions for Use IN-083R7 Rev. 8/16 BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A. 847-534-6000 1-800-247-3368 CAUTION: U.S. Federal law restricts this device to sale by or on the order of a dental professional.

D.T. LIGHT-POST * Double Taper Radiopaque Translucent Fiber Post System GENERAL INFORMATION D.T. LIGHT-POST posts are constructed from unidirectional, pretensed fibers bound in a resin matrix. This design produces a post with flexural strength exceeding that of metal posts but with a modulus of elasticity very close to that of dentin. The low modulus dissipates stress rather than transferring and concentrating stress in the residual root structures as seen with cast or prefabricated metal posts. Due to its translucency, BISCO s D.T. LIGHT-POST will transmit light and can be used with light-cured or dual-cured cements and adhesives. This post will intimately bond to the tooth structure and core build-up composite while its passive taper respects morphology and conserves tooth structure. INDICATIONS FOR USE: Fiber posts are intended to be cemented into the root canal of a tooth to stabilize and support a restoration. WARNING: Drills are sold non-sterile and must be sterilized prior to first use and between subsequent uses in accordance to the instructions provided below. CAUTION: Visually inspect the drills before each use and change to new drill when damaged, corroded or dull. Use a new drill after 12-15 uses. Posts are single use devices and should never be re-used. Structural integrity of the post could be compromised including microscopic damage which could lead to post fracture. PRECAUTION: Gloves must be worn when handling a post since the post fibers may irritate the skin and the oils on the skin may affect the bond strength of the post. The post must be cleaned with alcohol before insertion in the canal. Shortening the post should be done outside of the mouth. The use of rubber dam is strongly recommended. The crown must cover the preparation of at least 1.5 mm of healthy dentin in order to get the ferrule effect. When removing the color-coded rubber ring from the D.T. LIGHT-POST, do so outside the mouth to prevent accidental aspiration or swallowing of the ring by the patient. Never use pliers to cut the post since the pressure can destroy the structure of the post. In addition, surface alteration of the post (sandblasting or roughening with a bur) is not indicated. Safety data sheet available on request. Safety data sheet available at www.bisco.com. CLINICAL PROCEDURE With the tooth endodontically treated and filled with gutta-percha, the remaining tooth structure is prepared according to conventional principles. 1. SELECTION OF POST SIZE Posts are available in four different sizes to accommodate a variety of teeth and canal sizes. Drills and posts are color-coded for ease in determining which drill is to be used with each post. It also aids in size identification. #0.5 1.25 #1 1.5 #2 1.8 #3 2.2 0.8 0.9 1.0 1.2 ALL ALL DIMENSIONS DIMENSIONS ARE ARE IN IN MILLIMETERS MILLIMETERS Size #0.5 Post: Black Pre-Shaping/#0.5 Drill: Black Size #1 Post and Drill: Red Size #2 Post and Drill: Yellow Size #3 Post and Drill: Blue

A. Size and direction of canal is determined by radiographic examination. A mylar radiographic guide showing the various sizes of the posts is included with each system kit. B. A general recommendation can be followed for post size selection: Post #0.5 Post #1 Central and lateral mandibular incisors Anywhere else deemed appropriate for this size Central and lateral mandibular incisors Mesial and distal canals of maxillary molars Maxillary and mandibular premolars Mesial canals of mandibular molars Post #2 Lateral maxillary incisors Distal canals of mandibular molars Palatal canals of maxillary molars Maxillary and mandibular canines Post #3 Maxillary centrals and canines Palatal canals of maxillary molars Distal canals of mandibular molars Large/wide canals 2. CANAL PREPARATION A. General recommendations for post space preparation: The post should be 2 /3 to 3 /4 of the length of the root. A minimum of 3-5mm of gutta-percha should remain at the apex. Proper isolation must be used. B. Remove gutta-percha with a #1 or #2 Peeso Reamer, #3 Gates Glidden or a heated endodontic plugger. C. Shaping the canal: (1.) Use the D.T. Pre-Shaping Drill (black) to complete the preliminary preparation. This instrument determines the final depth to which the post will be placed and serves to guide the final preparation with the subsequent drills. (2.) An endodontic rubber stopper on the shaft of the drill should be used as a guide for determining the length of the preparation with radiographic verification. In order to ensure against root perforation while drilling, make sure the drill is always positioned within the canal. (3.) Remove debris from the canal with water followed by drying with paper points. D. Final canal preparation: (1.) Use the D.T. Drills in order, starting with the smallest, until the desired final size is accomplished. PLEASE NOTE: Posts require the sequential use of the drills as follows: Size #0.5: Use only the Pre-Shaping/#0.5 Drill (black), no additional use of other drills needed. Size #1: Use the Pre-Shaping Drill (black), followed by the size #1 Drill (red). Size #2: Use the Pre-Shaping Drill (black), followed by the size #1 Drill (red), followed by the size #2 Drill (yellow). Size #3: Use the Pre-Shaping Drill (black), followed by the size #1 Drill (red), followed by the size #2 Drill (yellow), then the size #3 Drill (blue). (2.) Ideally, the final canal preparation allows sufficient space for the post and 30 microns around the post for bonding materials. 3. DETERMINING POST LENGTH A. To determine the total length of the post: Try-in the post and mark the desired position. B. Remove the post from the canal and cut with a diamond bur or diamond disc. Never use pliers to cut the post since the pressure can destroy the structure of the post. In addition, surface alteration of the post (sandblasting or roughening with a bur) is not indicated.

C. When removing the color-coded rubber ring from the D.T. LIGHT-POST, do so outside the mouth to prevent accidental aspiration or swallowing of the ring by the patient. 4. POST CEMENTATION Please refer to the manufacturer s instructions for guidance when cementing post and building the core. 5. FINAL PREPARATION Conventional principles of tooth preparation (Ferrule Effect) must be followed for optimal results. Preparation for final restoration must end on sound tooth structure. There must be 1.5mm of sound tooth structure beyond the core material. Positive horizontal and vertical walls should exist. 6. INFECTION CONTROL D.T. Pre-Shaping Drill and D.T. #1, #2, #3 Drills: these instruments are supplied non-sterile. Disinfect and sterilize instruments before each use. Ultrasonically disinfect instruments with disinfecting or cleaning agents adapted for rotary instruments. Do not disinfect instruments in thermodisinfector. Inspect instruments visually before each use: change to new drills when they are damaged, corroded or dull. The universal drill may be used only to remove root canal filling partially, and the finishing drills may be used only to prepare root canal. D.T. drills must be sterilized individually in an autoclave with the following settings: Wrapped individually in disposable sterilization pouches or tubing that comply with the regulation standard enforced in the country of use (e.g. EN ISO 11607-1). Autoclave: type B complying with regulation standard in force (e.g. EN 13060). Sterilization temperature: 134 C/274ºF - sterilization time: 18 minutes. Use a new drill after 12-15 uses. INFECTION CONTROL FOR D.T. LIGHT-POST RECOMMENDED NOT RECOMMENDED DISINFECTION All chemical disinfection solutions or thermodisinfector CLEANING Alcohol e.g. ethanol: 1-5 minutes Boiling Ultrasonic cleaning STERILIZATION (if required) Hot air sterilization Gas sterilization/chemiclave Steam sterilization/autoclave (max. 134 C/274ºF) 18 minutes, 1 cycle only Wrapped individually in disposable sterilization pouches or tubing that comply with the regulatio standard enforced in the country of use (e.g. EN ISO 11607-1). Autoclave: type B complying with regulation standard in force (e.g. EN 13060). Note: Unapproved sterilization may render the post unusable.

POST REMOVAL: A D.T. LIGHT-POST REMOVAL KIT is available through BISCO. See POST REMOVAL TECHNIQUE description and instructions available with the D.T. LIGHT-POST REMOVAL KIT. (-80692P) HYGIENE: Drills are sold non-sterile and must be sterilized prior to first use and between subsequent uses in accordance with these instructions. DISPOSAL: Drills should be dispensed in an appropriate sharps container or in accordance with local policy. STORAGE: Store the sterilized components in a dry, dust-free place. If the packaging s integrity appears to be compromised, before using again, place the component in a new pouch and re-sterilize according to the protocol defined before. The drill should be stored in the sterilization container until required. Containers or pouches must be dry before opening to avoid recontamination of the contents with water. Storage should be in dry, clean conditions at ambient temperature. WARRANTY: BISCO, Inc. recognizes its responsibility to replace products if proven to be defective. BISCO, Inc. does not accept liability for any damage or loss, either direct or consequential, stemming from the use of or inability to use the products as described. Before using, it is the responsibility of the user to determine the suitability of the product for its intended use. The user assumes all risk and liability in connection therewith. RTD Patents: US 08/0280263A1 & Patent Pending. * D.T. LIGHT-POST is a registered trademarks of RTD France. D.T. LIGHT-POST was developed by RTD France. BISCO, INC. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A. 1-800-247-3368 847-534-6000 www.bisco.com BISICO France 1, allée de la Coudoulette 13680 Lançon De Provence France Tél. : 33-4-90-42-92-92