Anesthetic challenges when elective case becomes emergent

Similar documents
Preface... Acknowledgements... Contributors... 1 The Difficult Airway: Definitions and Algorithms The Expected Difficult Airway...

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

Educational Session: Evaluation and Management of the Difficult Airway

Recent Advances in Airway Management HA Convention 2014

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

The reasons 13/11/ Cost 2. Availability 3. Comparison 4. Complications 5. Knowledge. Pulmonary and critical care medicine (PCCM) fellows.

ISPUB.COM. The Video-Intubating Laryngoscope. M Weiss THE LARYNGOSCOPE INTRODUCTION TECHNICAL DESCRIPTION

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

In 2011 I received an unrestricted lecture honorarium from Ambu I have been loaned equipment by Intavent Direct (Teleflex) and Aircraft Medical As an

Dr.Bharghavi.M 2 nd year post graduate Dept of Anaesthesia

Cronicon ANAESTHESIA. Khaled Mohammed Elnaghy 1 and Javier Yuste 2 * Abstract. Keywords: Intubation; Video laryngoscopes; GlideScope; LMA CTrach

Airway/Breathing. Chapter 5

Advanced Airway Management. University of Colorado Medical School Rural Track

Fiberoptic bronchoscope and C-MAC video laryngoscope assisted nasal-oral tube exchange: two case reports

All I need is an LMA

Airway Management. Teeradej Kuptanon, MD

Airway Management & Safety Concerns Experience from Bariatric Surgery

Airway/Breathing. Chapter 5

The 2015 DAS Guidelines

LEVITAN S FIBREOPTIC STYLET: BEYOND BARRIERS. - Our Perspective.

Robin Foster MD FAAP FACEP Division Chief Pediatric Emergency Medicine Children s Hospital of Richmond at Virginia Commonwealth University Health

Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

A comparison between the GlideScope Ò Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways a pilot study

Difficult Airway. Department of Anesthesiology University of Colorado Health Sciences Center (prepared by Brenda A. Bucklin, M.D.)

Difficult Airway. Victor M. Gomez, M.D. Pulmonary Critical Care Medicine Medical City Dallas Hospital

A systematic review of the role of videolaryngoscopy in successful orotracheal intubation

Difficult Airway Management during Anesthesia: A Review of the Incidence and Solutions

I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy A Clinical Comparative Study

LMA CTrach TM in patients with anticipated difficult airway: A retrospective study

Endotracheal intubation with airtraq W versus storz W videolaryngoscope in children younger than two years - a randomized pilot-study

CONTINUING EDUCATION IN HONOR OF NORMAN TRIEGER, DMD, MD

Comparison of laryngoscopy and intubating conditions using kings vision laryngoscope and C-MAC video laryngoscope

Emergency Airway Management. Richard P. Dutton, M.D., M.B.A. Chief Quality Officer US Anesthesia Partners

HELP PROTECT YOUR PATIENTS AND PREVENT COMPLICATIONS.

INFORMED CONSENT FOR publication of the present

Question: Is this patient an infant? A patient less than 12 months old is considered an infant. Please check the box next to the appropriate choice.

Cricoid pressure: useful or dangerous?

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

Is the Airtraq optical laryngoscope effective in tracheal intubation by novice personnel?

Use of the Intubating Laryngeal Mask Airway

Introducing the Fastrach-LMA. Prepared by Jim Medeiros, NREMT-P Regional Field Coordinator Lord Fairfax EMS Council

Other methods for maintaining the airway (not definitive airway as still unprotected):

Intubation techniques

Airway Management and The Difficult Airway

(ix) Difficult & Failed Intubation Queen Charlotte s Hospital

Comparison of two methods of gum elastic bougie aided endotracheal intubation using Airtraq video laryngoscope

Video Laryngoscopy and its future in Airway Management

Haemodynamic response to orotracheal intubation: direct laryngoscopy versus fiberoptic bronchoscopy

How do you use a bougie as an airway adjunct for endotracheal intubation?

Success of Tracheal Intubation with Intubating Laryngeal Mask Airways

This interdisciplinary clinical support document provides guidelines for the safe establishment of an artificial airway.

Case Report Tracheal Intubation with Aura-i and ascope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway

Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope. Suzuki, Akihiro ; Katsumi, Norifumi ; Honda, Takashi ; Sasakawa,

Comparison of the Airtraq to the Bonfils Fibroscope for Endotracheal Intubation in a Simulated Difficult Airway

The Glidescope Ò system: a clinical assessment of performance

Comparative Evaluation of Performance of Videolaryngoscope vs Fastrach Intubating Laryngeal Mask Airway

GENERAL ANAESTHESIA AND FAILED INTUBATION

Airway Workshop Lecture. University of Ottawa

Successful tracheal intubation using fiberoptic bronchoscope via an I-gel TM supraglottic airway in a pediatric patient with Goldenhar syndrome

COMPARISON OF DIRECT VERSUS INDIRECT LARYNGOSCOPY FOR INTUBATION IN THE PREHOSPITAL SETTING: A SYSTEMATIC REVIEW AND META-ANALYSIS

Anatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.

Airway Management. Key points. Rapid Sequence Intubation. Rapid Sequence Intubation Recognizing difficult airway Managing difficult airway

Case Presentation Topic: Difficult to Ventilate Difficult to Intubate

British Journal of Anaesthesia 100 (4): (2008) doi: /bja/aen002 Advance Access publication January 31, 2008

Original Article INTRODUCTION. Abstract

Optimising tracheal intubation success rate using the Airtraq laryngoscope

Provision of General Anesthesia Out of Hospital: Perspective from The Americas. Anthony Charles Caputo

Brief report Failed Intubating Laryngeal Mask Airway-Guided Blind Endotracheal Intubation in a Severe Postburn Contractured Neck Patient.

How to Predict and Avoid Airway Disasters. Muhammad Umer Ihsan

All bedside percutaneously placed tracheostomies

Comparison. F Agro immobilization. to DL Trauma/SCI. GS experiences. to other. GS experiences. GS experiences. to DL.

Retrospective audit of the air-q intubating laryngeal airway as a conduit for tracheal intubation in pediatric patients with a difficult airway

Omiros Chalkeidis*, Georgios Kotsovolis, Apostolos Kalakonas, Maria Filippidou, Christos Triantafyllou, Dimitris Vaikos, Epaminondas Koutsioumpas

The Superiority Of Mcgrath Videolaryngoscope After Failed Conventional Laryngoscopy

Citation British journal of anaesthesia, 104. pp ; 2010 is available onlin

Comparison of McGrath Series 5 video laryngoscope with Macintosh laryngoscope: A prospective, randomised trial in patients with normal airways

AIRWAY MANAGEMENT AND VENTILATION

N. Jagannathan 1, *, J. Hajduk 1, L. Sohn 1, A. Huang 1, A. Sawardekar 1, B. Albers 1, S. Bienia 2 and G. S. De Oliveira 3.

Laryngoscopy: Time to broaden our horizon.

Overview. Chapter 37. Advanced Airway Techniques. Sellick Maneuver 9/11/2012

Equipment: NRP algorithm, MRSOPA table, medication chart, SpO 2 table Warm

RESPIRATION AND THE AIRWAY. Editor s key points

Risky Extubation. Andy Higgs. Warrington Hospitals Cheshire UK

Airway/Breathing. Chapter 5

British Journal of Anaesthesia 102 (4): (2009) doi: /bja/aep013 Advance Access publication February 20, 2009

Essential Practices A clinical decision-making resource for the respiratory care professional

General OR Rotations GOALS & OBJECTIVES

Domino KB: Closed Malpractice Claims for Airway Trauma During Anesthesia. ASA Newsletter 62(6):10-11, 1998.

Anesthesia Final Exam

Hemodynamic Response to Tracheal Intubation Using New Airway Intubating Devices

The Laryngeal Mask Airway: Its Role in the Difficult Airway. Stephen L. Campo, MD William T. Denman, MB, ChB, FRCA

Published online 2015 December 5. Research Article

Corresponding author: X.-H. Li

Diagnosis & Management of the Difficult Airway

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 3/ Issue 64/Nov24, 2014 Page 13923

Comparison between C-MAC video-laryngoscope and Macintosh direct laryngoscope during cervical spine immobilization

Advanced Airway Management

Transcription:

Anesthetic challenges when elective case becomes emergent Shridevi Pandya Shah MD Asst Professor Dept of Anesthesiology Rutgers-NJMS Rutgers, The State University of New Jersey

Conflicts of interest: none

Case 8-week-old girl born at 36 weeks gestation with birth weight of 4 lbs and 3 oz,found at 4 weeks of age to have left eye discharge without other significant findings At 5 weeks mother noted bleeding from medial corner of left eye with some swelling on lateral aspect of eye At 6 weeks progressive protruding friable mass with inconclusive needle aspiration performed at the referring center that led to more bleeding

Preoperative anesthesia evaluation Preoperative interview: low birth weight, NICU stay for poor feeding but otherwise non contributory no formal pediatric clearance, most recent H&P in chart baby did have ECHO at birth - no congenital cardiac issues, genetic tests pending in view of low birth weight, failure to thrive, low set ears and slight micrognathia some runny nose, afebrile and chest clear Preoperative IV Hemoglobin, type and cross and cross

Hemodynamic instability Airway Oxygenation and ventilation Postoperative management

Challenges in operating room Labile vital signs mask ventilation Direct laryngoscopy revealing grade III Cormack Lehane view of glottis Rapid desaturation limiting time to laryngoscopy Unable to CONFIRM placement of Endotracheal tube with Glide Scope Unable to detect ETCO2 Decision to abort laryngoscopy Air Q LMA insertion successful blind intubation thru LMA

Our Patient Histopathologic exam of the specimen revealed Hemangiopericytoma of the orbit, She was found to have Trisomy 15

Hemangiopericytoma Facts Encapsulated hypercellular, hypervascular lesions derived from pericytes and present as solitary, deep, soft tissue masses with insidious growth HPC is a rare m in adults and extremely rare in children The majority of cases follow a benign clinical course Recurrent lesions have a more malignant course and can metastasize There is no correlation between mitotic rate and the clinical behavior

Cormack Lehane view

Glottic and supraglottic structures in infant - epiglottis, vallecula, pyriform fossa, larynx and hypopharynx.

2009 Anatomy and assessment of pediatric airway: Review article by Lola ADEWALE,Pediatric anesthesia

2015 Comparison of the rate of successful endotracheal intubation between the sniffing and ramped positions in patients with an expected difficult intubation a prospective randomized study Ju-Hwan Lee, Hoe-Chang Jung, Ji-Hoon Shim, and Cheol Lee Department of Anesthesiology and Pain Medicine, Wonkwang University School of Medicine, Iksan, Korea

Hyper extended position 2010 Changes in airway configuration with different head and neck Positions using magnetic resonance imaging of normal airways: A new concept with possible clinical applications Greenland et al,british journal of anesthesia

LMA Supreme I gel LMA Air Q LMA LMA flexible Ambu aura once

Laryngeal mask airway History LMAs- 1 st Generation- airway tube only 2 nd generation-gastric channel, improved pharyngeal seal and integral bite block 1788-first reference to tracheal intubation in humans 1878- first administration of anesthetic using endotracheal tube 1882-birth of extraglottic airway management 1908-Hewitt airway 1933- Guedel airway 1934-1 st cuffed oropharyngeal airway 1940-Berman airway 1968-1 st esophageal obturator 1981-1 st human use of laryngeal mask 2000-1 st reusable second generation SAD 2003-2010 single use second generation LMA

LMA Classic AND LMA Unique LMA Classic is first generation, versatile, reusable airway with aperture bars used extensively LMA Unique is single use airway packaged sterile and ready for use, suited for areas where a reusable device is not practical, economical or desirable

2014 2013

I gel LMA Intubating LMAs Ambu aura once Air Q LMA LMA fastrach

i gel, LMA fastrach and air Q permit direct passage of endotracheal tube Used as a rescue device for ventilation after induction of anesthesia Conduit for fiberoptic intubation Use of Aintree intubation catheter where difficulty encountered passing endotracheal tube through LMA 2015 2013 Evaluation of glottic view through Air-Q Intubating Laryngeal Airway in the supine and lateral position And assessing it as a conduit for blind endotracheal intubation in children in the supine position Pandey RK et al, Pediatric anesthesia To assess the efficacy of i-gel for ventilation, blind tracheal intubation and nasogastric tube insertion Geeta Bhandari, Anesthesia Essays and researches

2006 The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision : evaluation in 100 patients E.H.C. Liu, British Journal of Anesthesia

Air traq Has a built in channel for the tracheal tube Available in all pediatric sizes Used successfully in children with difficult airways May be more difficult to use in small infants Directs the tube leftward, requires manipulation of the device as a unit to help guide the tube in the trachea. May be used with a bougie or in combination with the fiberoptic bronchoscope

GlideScope McGrath Video 2011 A comparison of the Glide Scope to the McGrath videolaryngoscope in patients Woo Jae kyong Hun Kim et al, Korean society of Anesthesiologists

Better view of glottis than Mcintosh blade with GlideScope and Storz CMAC Views are comparable among GlideScope and Storz CMAC Devices like bougie may be needed for assistance since better glottic view don t directly translate into ease of intubation 2013 2012 A comparison of the GlideScope video laryngoscope to the C-MAC video laryngoscope for intubation in the emergency department Mosier J et al, ANN Emerg med Comparison of the GlideScope, CMAC,storz DCI with the Mcintosh laryngoscope during simulated difficult laryngoscopy:a manikin study David W Healy et el, BMC anesthesiology

2013 2008 A randomized comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during Mechanical ventilation for general anesthesia Ratajczyk P et al, Anesth intensive her The cobra PLA versus LMA unique in children Ron M Walls, Anesth and analgesia

Esophageal intubation is not a sin!

Thank you