FOOD SAFETY. VIDAS Staph enterotoxin II (SET2) Ultra Performance Summary CONFIDENCE DECIDE WITH

Similar documents
New publications in Food Microbiology : EN and ISO* standards, FDA-BAM, USDA/FSIS since Nov Reference Progress Scope.

AFLATOXIN M1 CAT. NO. 961AFLMO1M

Is it Method Verification or Validation, or Just Semantics? Michael Brodsky Brodsky Consultants

Human HIV (1+2) antigen&antibody ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit

SensoLyte pnpp Alkaline Phosphatase Assay Kit *Colorimetric*

Amantadine ELISA Test Kit

Toxoplasma gondii IgM ELISA Kit

Toxoplasma gondii IgM ELISA Kit

Helicobacter pylori IgA ELISA Kit

Triiodothyronine (T3) ELISA

Anthrax protective antigen IgG ELISA Kit

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

RayBio Human Granzyme B ELISA Kit

Human IL-2. Pre-Coated ELISA Kit

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Serum Amyloid A ELISA

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Insulin (Porcine/Canine) ELISA

Potato leafroll virus (PLRV) Reagent Set DAS ELISA, Alkaline phosphatase label Catalog number: SRA List of contents

Mouse Ultrasensitive Insulin ELISA

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Human Cytomegalovirus IgM ELISA Kit

Mouse C-peptide ELISA

Bovine Insulin ELISA

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Procine sphingomyelin ELISA Kit

Porcine/Canine Insulin ELISA

Apolipoprotein A-1 ELISA

Thyroid Stimulating Hormone (TSH) ELISA Catalog No. GWB , legacy id (96 Tests)

Mouse C-peptide ELISA

Human Alpha 1 microglobulin ELISA Kit

Alkaline Phosphatase Assay Kit (Fluorometric)

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Rat Proinsulin ELISA

Cotinine (Mouse/Rat) ELISA Kit

Toxoplasma gondii IgM (Toxo IgM)

Abraxis Progesterone (bovine) ELISA Kit

Oxytetracycline ELISA Test Kit Manual Catalog #: 1081 Reference #: D

Human Apolipoprotein A1 EIA Kit

YK052 Mouse Leptin ELISA

Chymotrypsin ELISA Kit

T3 (Total) (Mouse/Rat) ELISA Kit

CoQ10(Coenzyme Q10) ELISA Kit

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

EPIGENTEK. EpiQuik Global Histone H3 Acetylation Assay Kit. Base Catalog # P-4008 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Mitochondrial Trifunctional Protein (TFP) Protein Quantity Microplate Assay Kit

PVY Reagent Set Compound ELISA, Alkaline phosphatase label Potato virus Y Catalog number: SRA 20001

RayBio Human ENA-78 ELISA Kit

EPIGENTEK. EpiQuik Global Histone H4 Acetylation Assay Kit. Base Catalog # P-4009 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

GLP-2 ELISA. For the quantitative determination of GLP-2 in human serum and plasma samples.

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Cortisol (Sheep) ELISA Kit

FOR LABORATORY USE ONLY

HbA1c (Human) ELISA Kit

C-Peptide I and II (Rat) ELISA

Reagent Set DAS ELISA, Alkaline phosphatase label SRA 22001, SRA 23203, SRA 27703, SRA & SRA ToRSV, ArMV, GFLV, AnFBV and PDV

I. Introduction. II. Characteristics

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

RayBio Human Thyroglobulin ELISA Kit

Rat C-Peptide EIA. Cat. No. YII-YK010-EX FOR LABORATORY USE ONLY

Food Allergen ELISA Kit

DIAGNOSTIC AUTOMATION, INC.

Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

Human Obestatin ELISA

Salbutamol ELISA Test Kit Manual Catalog #: 1022 Reference #:

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Interior of SPRs coated with thyroxine.

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

Vedolizumab Drug Level ELISA

Mouse C3 (Complement Factor 3) ELISA Kit

Rubella virus IgG ELISA Kit

Mycoplasma pneumoniae IgG ELISA Kit

Instructions for Use. Tg Antibody ELISA

Human Influenza A (Swine Flu) Rapid test

Human TSH ELISA Kit. User Manual

Mouse C-Peptide ELISA Kit

Mouse Adiponectin Immunoassay Kit

Egg Protein Residue ELISA Kit

Reagent Set DAS ELISA, Alkaline phosphatase label

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection.

Human Immunodeficiency Virus type 1 (HIV-1) gp120 / Glycoprotein 120 ELISA Pair Set

Aac Reagent Set ELISA for the detection of Acidovorax avenae subsp. citrulli Catalog number: SRA 14800

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Rat Glicentin EIA FOR RESEARCH USE ONLY. <Distributed by> DF Kasumigaseki Place, 3-6-7, Kasumigaseki, Chiyoda-ku Tokyo Japan

Estrone EIA kit. For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media. Cat. No.

FinTest IgG4 Screen 20 ELISA KIT

IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol

Global Histone H3 Acetylation Assay Kit

See external label 2 C-8 C Σ=96 tests Cat # 3171Z. Free Estriol. Cat # 3171Z. Enzyme Linked Immunosorbent Assay

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Transcription:

FOOD DECIDE WITH SAFETY CONFIDENCE VIDAS Staph enterotoxin II (SET2) Ultra Performance Summary Food safety professionals have a variety of test kits to choose from when looking to fill a need in their laboratory. One of the main criteria used in making their decision is an evaluation of the certifications the test kit has received. Validation studies provide a user with confidence in the performance of the test kit. This document summarizes the biomérieux VIDAS Staph enterotoxin II (SET2) test method validation studies. The VIDAS SET2 method was certified by the AOAC Research Institute Performance Tested Method SM (PTM) program after the completion of a single laboratory study and an independent laboratory study. These studies included an evaluation of the following parameters: inclusivity, exclusivity, robustness, lot-to-lot/stability and method comparison. The VIDAS SET2 method was also adopted as an AOAC Official Method of Analysis (OMA), First Action status after the completion of a multi-laboratory method comparison study. Additionally, the VIDAS SET2 method was evaluated by a European reference laboratory and was recognized as an official method of analysis in Europe. All of the validation studies demonstrated that the VIDAS SET2 method was statistically equivalent to the corresponding reference method for the matrices tested with 95% confidence.

AOAC Performance Tested Method: PTM#070404 In September 2011, the VIDAS SET2 Assay was granted Performance Tested Method SM (PTM) status by the AOAC Research Institute for the detection of staphylococcal enterotoxins in a variety of foods. The VIDAS SET2 method was validated according to harmonized PTM and Official Method of Analysis guidelines (2002). Results of the validation study demonstrated the ability of the VIDAS SET2 method to: 1) support a 12-month shelf life and quality of the test kit; 2) perform appropriately after varied protocol parameters including sample volume used in the assay (300, 400, 450, 500, 550, 600 μl, extraction ph (6, 6.5, 7, 7.5, 8, 8.5), time reagents held at room temperature (after refrigeration) prior to performing VIDAS SET2 method (0, 30, 60, 120 min); and 3) demonstrate no statistically significant differences when compared to a reference method for 15 claimed matrices using a 25g test portion size: frozen lasagna, chocolate éclair, canned mushrooms (post-retort spiking), powdered eggs, roast beef, cooked chicken, ham, unpasteurized milk, cheddar cheese and yogurt (internal); Italian salami, smoked salmon, potato salad, ice cream and nonfat dry milk (noninstant) (contract). The Independent Study evaluated smoked salmon. AOAC Official Method: Certificate No: 2007.06 In 2007, the VIDAS SET2 Assay was granted First Action AOAC Official Methods of Analysis SM (OMA) status by the AOAC Research Institute for the detection of staphylococcal enterotoxins after the completion of the AOAC PTM evaluation and a collaboratively studied evaluation of cooked chicken, ham, potato salad, pasteurized liquid whole milk, and canned mushrooms. Nineteen laboratories received six replicate test portions from each of the three contamination levels. Following the appropriate extraction protocol, each test portion was analyzed by the VIDAS SET2 method. Performance parameters calculated included detection rate, specificity, and percent false positive. European Validation Study Table of Contents VIDAS SET2 1 Table A. Validation Study Technical Requirements 3 AOAC PTM Validation Study 4 Table B. AOAC PTM Method Comparison Study Results - Internal 6 Table C. AOAC PTM Method Comparison Study Results - Independent 7 Official Methods of Analysis (OMA) Validation Study 5 Table D. AOAC OMA Collaborative Study Data Summary 8 European Validation Study 9 Table E. Inclusivity Results 9 Table F. Method Comparison Results 10 Table G. VIDAS SET2 Results From Interlaboratory Study 10 Glossary of Terms 11 An independent laboratory evaluated the ability of the VIDAS SET2 method to detect 46 different Staphylococcus aureus isolated for the presence of enterotoxins as well as a method comparison study comparing the VIDAS SET2 to the CRL confirmatory method on 62 milk and milk product samples. A VIDAS SET2 interlaboratory study (21 laboratories) was performed using freeze-dried cheese samples contaminated with known concentrations of enterotoxins.

VIDAS Staph enterotoxin II (SET2) Catalog Number - REF 30 705 Figure 1. Flow diagrams showing the VIDAS SET2 standard protocols VIDAS SET2 General Extraction Protocol To 25 g of food, add 25 ml of reconstituted extraction buffer diluted as indicated previously, in a Stomacher- type bag. Blend at high speed for 3 minutes to obtain a homogeneous suspension. Contents of the VIDAS SET2 Kit 30 SET2 Strips 30 SET2 SPR s Standard SET2 SET2 Positive Control Negative Control SET2 Concentrated Extraction Buffer 1 MLE Card (Master Lot Entry) 1 Package insert provided in the kit or downloadable from www.biomerieux.com/techlib Incubate 26-30 hr at 37±1 C Centrifuge the blended sample in the extraction solution for 15 minutes at 3000-5000 g at 18-25 C. Pump the supernatant through a moistened absorbent cotton placed in a syringe, using the plunger. Principle of the Assay VIDAS Staph enterotoxin II is an enzyme-linked fluorescent immunoassay (ELFA) for use on the VIDAS family instrument (see the Operator s Manual) for the specific detection of staphylococcal enterotoxins. The Solid Phase Receptacle (SPR) serves as the solid phase as well as the pipetting device. The interior of the SPR is coated with anti staphylococcal enterotoxin antibodies. Reagents for the assay are ready-to-use and pre-dispensed in the sealed reagent strips. All of the assay steps are performed automatically by the instrument. The reaction medium is cycled in and out of the SPR several times. Part of the food extract is dispensed into the reagent strip. The antigens present will bind to the anti-enterotoxin antibodies which are coated on the interior of the SPR. Unbound sample components are washed away. Alkaline phosphatase-labeled antibodies are cycled in and out of the SPR and will bind to any Staphylococcal enterotoxins which are themselves bound to the antibodies on the SPR wall. Further wash steps remove unbound conjugate. During the final detection step, the substrate (4-Methyl- umbelliferyl phosphate) is cycled in and out of the SPR. The bound enzyme conjugate catalyzes the hydrolysis of this substrate into a fluorescent product (4-Methyl- umbelliferone), the fluorescence of which is measured at 450 nm. At the end of the assay, the results are automatically analyzed by the instrument which calculates a test value each sample. This value is compared to internal references (thresholds) and each result is interpreted (positive, negative). Check the filtrate ph and adjust it to between 7.5 and 8.0 if necessary, using 1N NaOH. Recover 500 μl of the filtrate and place in the sample well of a VIDAS SET2 Reagent strip before initiating the assay. Page 1 Page 2

Performance Tested Method SM (PTM) The AOAC Performance Tested Methods SM (PTM) program was formed in 1992 and is a method certification program for proprietary methods. Methods certified as Performance Tested SM were found to perform according to the manufacturer s documented claims and are used throughout the global market place and within the regulatory arena. The PTM program offers certification as an endpoint for method evaluation or as an entry to method validation for programs requiring increased confidence and method reproducibility information. Validation study protocols are written according to AOAC Microbiology Guidelines (2002 or 2012) and include the following technical requirements: inclusivity/exclusivity, method developer method comparison, independent laboratory method comparison, robustness, product consistency, product stability and instrument variation (where applicable) studies. More information can be found at www.aoac.org. Official Methods of Analysis SM (OMA) The Official Methods of Analysis SM (OMA) program is offered by AOAC INTERNATIONAL and evaluates chemistry, microbiology, and molecular biology methods. It also evaluates traditional bench-top methods, instrumental methods, and proprietary, commercial, and/or alternative methods. Validation study protocols are written according to AOAC Microbiology Guidelines (2012) and include the following technical requirements: inclusivity/exclusivity, method developer method comparison and collaborative method comparison studies. More information can be found at www.aoac.org. Table A. Validation Study Technical Requirements Study Type AOAC PTM AOAC OMA AFNOR Method Developer l l Independent l l Collaborative l l AOAC PTM Validation Study PTM Certification#: 070404 PTM Certified: September 2011 PTM Matrix Extension Certified: January 2013 Guideline document: AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Qualitative and Quantitative Food Microbiological Official Methods of Analysis (2002) Method Comparison (Tables B and C): The method comparison study was performed at both the method developer (internal) and independent laboratories. Food matrices were spiked with individual toxin serotypes at three levels: 2.00 ng/g, 1.00 ng/g and ng/g. Each toxin serotype was tested in three of the fifteen foods. Twenty-five gram portions were individually spiked with the appropriate amount of diluted toxin and samples were extracted immediately after spiking. Five replicate samples at each level were examined by the VIDAS SET2 method as well as five unspiked controls. Combining the data from both laboratories, of the 300 spiked samples, 297 were determined to be positive by the VIDAS method, yielding 99.0% overall detection for spiked samples. The percentage of spiked samples detected was 100% at the 2.00 ng/g and 1.00 ng/g levels and 97.0% at the ng/g level. In the 100 uninoculated control food samples, none were determined to be positive by the VIDAS method, for a specificity of 100% in this study. The false negative rate was 1% overall (3 false negative results out of 300 spiked samples) and there were no false positive results. All three false negative results occurred in ice cream without TCA precipitation at ng/g spiking level. There were slight differences in the percentage of spiked samples detected with and without TCA precipitation. For the fifteen matrices, detection of spiked samples overall was 100% (225/225) when TCA precipitation was used with the dairy extracts and, when TCA precipitation was not used, the detection was 98.0% (222/225). The limit of detection was determined to be ng/g for all toxin serotypes and foods, except ice cream, which had a limit of detection of 1.0 ng/g in this study. TCA concentration of ice cream at an initial spiking level of ng toxin per gram of food extract allowed positive detection of this sample. Lot-to-lot: Three lots of VIDAS SET2 reagents were compared using purified toxins A, B, C2, D and E each at 0.5 ng/ml, ng/ml and 0.10 ng/ml. Unspiked foods were included as negative controls. The variability between lots was not considered significant. Stability: Stability of the VIDAS SET2 kit was tested in real-time experiments. Kits were held at normal storage temperature (5 ± 3 C) for up to 12 months and tested at various intervals. Test samples included purified toxins, kit controls and a negative food sample. The variability between the kits over time was not considered significant. Page 3 Page 4

Ruggedness: Three test parameters were varied for ruggedness testing, including sample volume, test kit temperature equilibration and extract ph. Purified toxins (0.1 ng/ml or ng/ml) and negative food samples were tested with the sample volume (300 to 600 µl) and temperature equilibration (0 to 240 minutes at room temperature) variations. To demonstrate the effect of final extract ph on the VIDAS results, three foods were each spiked with toxins A E or left unspiked. After extraction, the extracts were adjusted to various ph values and tested on the VIDAS system. There were no differences seen in the number of positive results after with each of the variations in the protocol. Inter-assay Reproducibility: Toxins A, B, C2, D and E diluted in PBS BSA and standard S1 (toxin A) were tested in duplicate in 46 assays over 8 weeks (2 assays per day and 3 days per week for the first 7 weeks, then 2 days per week for the last week). This yielded 92 data points for each toxin. Two production lots of VIDAS SET2 reagents were tested. Test values were calculated using the value of the standard S1 tested every 14 days. The variability between assays was not considered significant. Inter-instrument Reproducibility: Toxins A, B, C2, D and E diluted in PBS BSA, three negative food matrices and control C2 were tested singly and standard S1 in duplicate on five different VIDAS instruments. Test values were determined using the average value of standard S1. One lot of VIDAS reagents was used for this study. The variability between instruments was not considered significant. Official Methods of Analysis (OMA) Validation Study Certificate No: 2007.06 Certification date: 2006 Guideline document: AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Qualitative and Quantitative Food Microbiological Official Methods of Analysis (2002) Collaborative Study: Pasteurized Milk (Table D): A multilaboratory study was conducted to determine the limit of detection (LOD) of Staphylococcal enterotoxins (SET) in 5 foods. Cooked chicken, ham, potato salad, pasteurized liquid whole milk, and canned mushrooms were each spiked with a different enterotoxin (A, B, C1, D, or E), and tested at and 0.5 ng/g SET levels to determine the LOD of the assay for those foods in a collaborative study. Unspiked controls were also included. A total of 19 laboratories representing government and industry participated. In this study, 1674 test portions were analyzed, of which 1638 were used in the statistical analysis. Of the 1638 test portions used in the statistical analysis, 1104 were spiked test portions, of which 1073 were positive by the VIDAS Staph enterotoxin II (SET 2) method. The detection rates at the ng/ml level were: cooked chicken, 98.2%; ham, 99.0%; potato salad, 99.1%; liquid whole milk, 85.2%; and canned mushrooms, 100%. The detection rates at the 0.5 ng/ml level were cooked chicken, 97.4%; ham, 98.1%; potato salad, 100%; liquid whole milk, 99.0%; and canned mushrooms, 100%. The data indicate that the SET 2 method is capable of detecting SET at ng/g in cooked chicken, ham, potato salad, and canned mushrooms and at 0.5 ng/g in pasteurized liquid whole milk. Table B. AOAC PTM Method Comparison Study Results - Internal INTERNAL LABORATORY DATA Toxin Extraction Protocol Roast beef A Meat & seafood Cheddar cheese A Dairy with TCA Cheddar cheese A Dairy without TCA Ham B Meat & seafood Yogurt B Dairy with TCA Yogurt B Dairy without TCA Chocolate éclair C General Cooked chicken C Meat & seafood Frozen lasagna D General Canned mushrooms D Canned food Powdered eggs E Dehydrated protocol followed by Dairy Unpasteurized milk E Dairy with TCA Unpasteurized milk E Dairy without TCA Level (ng/g) Total Tested Total Positive Detection rate, % LOD/g Specificity False positive, % 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 5 5 100 Detection rate = total number of positive test portions/total number of test portions x 100 LOD/g = limit of detection of the assay per gram/ml Specificity = total number of negative test portions/total number of know negative test portions x 100 False positive = 100-sensitivity Page 5 Page 6

Table C. AOAC PTM Method Comparison Study Results Independent Table D. AOAC OMA Collaborative Study Data Summary INTERNAL LABORATORY DATA Toxin Extraction Protocol Meat & seafood A Meat & seafood Meat & seafood B Meat & seafood General C General Dairy with TCA D Dairy with TCA Dairy without TCA D Dairy without TCA Dehydrated followed by Dairy with TCA Dehydrated followed by Dairy without TCA E E Dehydrated followed by Dairy with TCA Dehydrated followed by Dairy without TCA Level (ng/g) Total Tested Total Positive Detection rate, % 5 5 100 LOD/g Specificity False positive, % 5 5 100 5 5 100 5 5 100 2 2 40 5 5 100 5 5 100 1.0 INTERNAL LABORATORY DATA Toxin Extraction Protocol Cooked chicken A Meat & seafood Ham B Meat & seafood Potato Salad C1 General Pasteurized liquid whole milk D Dairy without TCA Canned mushrooms E Canned food Level (ng/g) Total Tested Total Positive Detection rate, % 0.5 114 111 97.4 114 112 98.2 LOD/g Specificity False positive, % 0 114 0 100 0 0.5 108 106 98.1 108 107 99 0 108 0 100 0 0.5 108 108 100 108 107 99.1 0 108 0 100 0 0.5 102 101 99 102 87 85.2 0 102 0 100 0 0.5 114 114 100 114 114 100 0 114 0 100 0 Detection rate = total number of positive test portions/total number of test portions x 100 LOD/g = limit of detection of the assay per gram/ml Specificity = total number of negative test portions/total number of know negative test portions x 100 False positive = 100-sensitivity 1.0 Detection rate = total number of positive test portions/total number of test portions x 100 LOD/g = limit of detection of the assay per gram/ml Specificity = total number of negative test portions/total number of known negative test portions x 100 False positive = 100-sensitivity Page 7 Page 8

European Validation Study Single Laboratory Study: Intralaboratory validation according to the EN ISO 16 140 Standard of the VIDAS SET2 detection kit for use in official controls of staphylococcal enterotoxins in milk products, Journal of Applied Microbiology 102 (2007) 1261 1272 Interlaboratory Study: Interlaboratory Validation of the VIDAS SET2 Kit for Detection of Staphylococcal Enterotoxins in Milk Products, Hennekinne et al.: JOURNAL OF AOAC INTERNATIONAL Vol. 90, No. 3, 2007 Guideline document: ISO 16140, Microbiology of food and animal feeding stuffs Protocol for the validation of alternative methods (2003) Reference Method: Community Reference Laboratory (CRL) Confirmatory Method Method Comparison (Table F): The purpose of these tests was to evaluate the performance of the VIDAS SET2 method with respect to the CRL Confirmatory Method, on test portions naturally contaminated with milk and milk products. The study evaluated 62 test portions: cheese 59, cake 1, milk 2. The results demonstrated perfect agreement (no positive or negative deviations) between the VIDAS SET2 and CRL method. Table F. Method Comparison Results CRL Confirmatory Method + - Single Laboratory Study Inclusivity (Table E): The inclusivity studies demonstrated that the VIDAS SET2 method 97.8% agreement between VIDAS SET2 and PCR method when analyzing 46 different Staphylococcus aureus isolates from food poisoning outbreaks. VIDAS SET2 + 20 0-0 42 Table E. Inclusivity Results PCR Assay + - Inter-laboratory Study (Table G): An interlaboratory study was organized to evaluate freeze-dried, low-fat cheese contaminated with known toxin concentrations. Six freeze-dried samples (2 uninoculated, 2 inoculated at a low level, 0.1 ng/g and 2 inoculated at a high level, ng/g) and 3 ready-to-use concentrated extracts were analyzed, in duplicate, by 21 laboratories following the VIDAS SET2 method. Due to laboratory errors, results from the freeze-dried samples were used from 18 laboratories and results from the concentrated extracts from 19 laboratories. Testing showed 100% detection using the VIDAS SET2 method. VIDAS SET2 + 32 1-0 13 Table G. VIDAS SET2 Results From Inter-laboratory Study Freeze-dried samples Ready-to-use concentrated extracts Total Tested Total Positive Total Tested Total Positive Uninoculated 108 108 19 19 Low 108 108 19 19 High 108 108 19 19 Page 9 Page 10

Glossary of Terms Collaborative Study A validation study performed by multiple laboratories to estimate critical VIDAS SET2 method performance parameters. See also inter-laboratory study. Detection rate Total number of positive test portions/total number of test portions x 100. False positive 100-sensitivity Inter-laboratory Study A validation study performed by multiple laboratories to estimate critical VIDAS SET2 method performance parameters. See also collaborative study. Limit of detection (LOD) The lowest level tested yielding positive results for all replicates. Negative agreement Results for both the VIDAS SET2 method and the reference method are negative. Negative deviation Result for the VIDAS SET2 method is negative and the result for the reference method is positive. Positive agreement Results for both the VIDAS SET2 method and the reference method are positive. Positive deviation Result for the VIDAS SET2 method is positive and the result for the reference method is negative. Specificity The total number of negative test portions/total number of known negative test portions x 100. Test portion A specified quantity of the sample that is taken for analysis by the method. Page 11 Page 12

Page 13 For more information, please contact your local biomérieux Account Representative. www.biomerieux-usa.com/phage