Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

Similar documents
Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

3-D dose verification by cone-beam optical CT scanning of PRESAGE dosimeter

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

1. Fast Cone Beam Optical CT Scanning of a Radiochromic Solid Dosimeter for Clinical 3 D Dose Verification By S J Hoogcarspel, Y Xu, and C Wuu From: M

Verification of micro-beam irradiation

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Radiochromic 3D Detectors

1.. Evaluating the peak-to-valley dose ratio of Synchrontron Microbeams using PRESAGE fluorescence By: N Annabell, N Yagi, K Umetani, C Wong and M Ges

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Advanced Applications of 3D Dosimetry and 3D Printing in Radiation Therapy. Devin Miles 2016 DUKE Master Thesis

Dosimetric characteristics of intensity-modulated radiation therapy and RapidArc therapy using a 3D N-isopropylacrylamide gel dosimeter

COMPARISON OF RADIOBIOLOGICAL EFFECTS OF CARBON IONS TO PROTONS ON A RESISTANT HUMAN MELANOMA CELL LINE

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Dosimetry and QA of proton and heavier ion beams

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients


Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning


Radiochromic film dosimetry in water phantoms

Leila E. A. Nichol Royal Surrey County Hospital

Activity report from JCOG physics group

Hampton University Proton Therapy Institute

Treatment Planning (Protons vs. Photons)

3D DOSIMETRY IN END-TO-END DOSIMETRY QA

Y FILMS DOSIMETR Nederland België / Belgique

The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Proton and helium beams: the present and the future of light ion beam therapy

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

Active Scanning Beam 3 Checking Delivery/Dosimetry

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Real-time Volumetric Scintillation Dosimetry for Radiation Therapy

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Limits of Precision and Accuracy of Radiation Delivery Systems

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

Application(s) of Alanine

Correction of Prompt Gamma Distribution for Improving Accuracy of Beam Range Determination in Inhomogeneous Phantom

PREDICTION OF ABSORBED DOSE DISTRIBUTIONS AND NEUTRON DOSE EQUIVALENT VALUES IN PROTON BEAM RADIATION THERAPY

Advanced film dosimetry for a UK brachytherapy audit

Evaluation of PRESAGE dosimeters for brachytherapy sources and the 3D dosimetry and characterization of the new AgX I seed model

A feasibility study of multislice X-ray CT imaging of gel dosimeters using the zero scan method

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

RPC s Credentialing Programs for Clinical Trials

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

EORTC Member Facility Questionnaire

Three Dimensional Dosimetry. Session Program: Therapy Education Session Organizer: L. John Schreiner

Electron Beam ET - Reloaded Therapy - Reloaded

Proton and heavy ion radiotherapy: Effect of LET

Assistant Professor Department of Therapeutic Radiology Yale University School of Medicine

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Australian Journal of Basic and Applied Sciences. Evaluation of CT based MAGAT gel dosimetry system for measuring 3D dose distribution

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

How Should We Verify Complex Radiation Therapy Treatments?

Application of Implanted Markers in Proton Therapy. Course Outline. McLaren Proton Therapy Center Karmanos Cancer Institute McLaren - Flint

CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY

CALCULATION OF BACKSCATTER FACTORS FOR LOW ENERGY X-RAYS USING THE TOPAS MONTE CARLO CODE

Follow this and additional works at: Part of the Medicine and Health Sciences Commons

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Predicting the risk of developing a radiationinduced second cancer when treating a primary cancer with radiation

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Small field diode dosimetry

Discuss the general planning concepts used in proton planning. Review the unique handling of CTV / ITV / PTV when treating with protons

A practical three-dimensional dosimetry system for radiation therapy

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

3D Dosimetry with Polymer Gel

Water equivalent PRESAGE for synchrotron radiation therapy dosimetry

Considerations when treating lung cancer with passive scatter or active scanning proton therapy

IN VIVO IMAGING Proton Beam Range Verification With PET/CT

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Comparison of Energy Dependence of PAGAT Polymer Gel Dosimeter with Electron and Photon Beams using Magnetic Resonance Imaging

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

8/1/2016. Motion Management for Proton Lung SBRT. Outline. Protons and motion. Protons and Motion. Proton lung SBRT Future directions

QA for Clinical Dosimetry with Emphasis on Clinical Trials

X-ray computed tomography imaging of polymer gel dosimeters

Specifics of treatment planning for active scanning and IMPT

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

IMRT QA: Point Dose Measurements or 2D Array?

Imaging of Radiation Dose Using Cherenkov Light

VIP. MRI magnetic resonance imaging. Keywords: PHITS, gel dosimeter, three dimensional dose distribution, LET dependence, dose verification MRI 2)

Dose differences between the three dose calculation algorithms in Leksell GammaPlan

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Use of Electronic Portal Image Detectors for Quality Assurance of Advanced Treatments

Transcription:

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE formulations irradiated by a 62 MeV proton beam were compared with that in water using GEANT4 Monte Carlo simulations. The dose delivered by secondary particles was also calculated. Our results show that after water-equivalent depth scaling, PRESAGE can be considered water equivalent for dosimetry of a 62 MeV clinical proton beam Investigation of photon and proton overlapping fields in PRESAGE dosimeters M Carroll, G Ibbott, R Grant, M Gillin and J Adamovics 2013 J. Phys.: Conf. Ser. 444 012059 To evaluate the effects of overlapping dose volumes for varying field arrangements in PRESAGE, several sequential beam irradiations were delivered each to formulations intended for, and irradiated with, proton beams as well as photon beams. The dosimeters were irradiated within timespans consistent of overlapping fields in clinical treatment plans. Dose profiles taken along the beam direction indicated slight over-responses in higher dose regions relative to similar irradiations given in a single fraction. These results will aid future measurements of overlapping field treatment plans delivered to PRESAGE for treatment verification of proton and photon 3D dosimetry. Preliminary characterization of PRESAGE for 3D dosimetry of 62 MeV proton beam T Gorjiara, A Kacperek, Z Kuncic, C Baldock,and S Doran 2013 J. Phys.: Conf. Ser. 444 012058 PRESAGE has previously shown potential for 3D dosimetry of heavy particles. A new formulation has specifically developed for dosimetry of protons/heavy ions. This work provides a preliminary characterization the new formulation of PRESAGE by measuring optical absorbance and dose response after irradiating by a 62 MeV proton beam for a dose range of 0.5 20 Gy. Results show linear dose response and the evolution over time of the optical density of the 3D dosimeter.

Water and tissue equivalence of a new PRESAGE formulation for 3D proton beam dosimetry: A Monte Carlo study Gorjiara, Tina; Kuncic, Zdenka; Doran, Simon; Adamovics, John; Baldock, Clive Medical Physics (2012), 39(11), 7071-7079. Purpose: To evaluate the water and tissue equivalence of a new PRESAGE 3D dosimeter for proton therapy. Methods: The GEANT4 software toolkit was used to calc. and compare total dose delivered by a proton beam with mean energy 62 MeV in a PRESAGE dosimeter, water, and soft tissue. The dose delivered by primary protons and secondary particles was calcd. Depth-dose profiles and isodose contours of deposited energy were compared for the materials of interest. Results: The proton beam range was found to be 27 mm for PRESAGE, 29.9 mm for soft tissue, and 30.5 mm for water. Investigation of PRESAGE Dosimeters for Proton Therapy M Carroll, G Ibbott, R Grant, M Gillin and J Adamovics 2013 J. Phys.: Conf. Ser. 444 012059 To evaluate the effects of overlapping dose volumes for varying field arrangements in PRESAGE, several sequential beam irradiations were delivered each to formulations intended for, and irradiated with, proton beams as well as photon beams. The dosimeters were irradiated within timespans consistent of overlapping fields in clinical treatment plans. Dose profiles taken along the beam direction indicated slight overresponses in higher dose regions relative to similar irradiations given in a single fraction. These results will aid future measurements of overlapping field treatment plans Dosimetric assessment of the PRESAGE dosimeter for a proton pencil beam delivered to PRESAGE for treatment verification of proton and photon 3D dosimetr C-S Wuu 1, Y Xu 2, X Qian 1, J Adamovics 3, E Cascio 4 and H-M Lu 2013 J. Phys.: Conf. Ser. 444 012055 The objective of this study is to assess the feasibility of using PRESAGE dosimeters for proton pencil beam dosimetry. Two different formulations of phantom materials were tested for their suitability in characterizing a single proton pencil beam. The dosimetric response of PRESAGE was found to be linear up to 4Gy. First-generation optical CT scanner, OCTOPUS TM was used to implement dose distributions for proton pencil beams since it provides most accurate readout. Percentage depth dose curves and beam profiles for two proton energy, 110 MeV, and 93 MeV, were used to evaluate the dosimetric performance of two PRESAGE phantom formulas. The findings from this study show that the dosimetric properties of the phantom materials match with basic physics of proton beams.

Characterization of the optical properties and stability of Presage following irradiation with photons and carbon ions Yates, Esben S.; Balling, Peter; Petersen, Joorgen B. B.; Christensen, Mehrnaz N.; Skyt, Peter S.; Bassler, Niels; Kaiser, Franz-Joachim; Muren, Ludvig P. Acta Oncologica (2011), 50(6), 829-834. Background: The on-going development of both intensity-modulated radiotherapy(imrt), including the more recent intensity-modulated arc therapy, as well as particle beam therapy, has created a clear need for accurate verification of dose distributions in three dimensions (3D). Presage is a new 3D dosimetry material that exhibits a radiochromic response when exposed to ionizing radiation. In this study we have 1) developed an improved optical set-up for measurements of changes in OD of Presage point dosimeters, 2) investigated the dose response of Presage for photons and carbon ion Investigation of PRESAGE Dosimeters for Proton Therapy R Grant, G Ibbott, X Zhu, M Carroll, J Adamovics, M Oldham, and D Followill Med. Phys. 38, 3571 (2011) SU E T 363 Purpose: To evaluate a formulation of PRESAGE intended for proton therapy and to use it to compare measurements with calculations for a spot scanning pencil proton beam and a passively scattered proton beam. Methods: Two 7.5 cm high by 9.5 cm diameter cylindrical PRESAGE dosimeters were used. CT images were used to design two treatment plans with an Eclipse treatment planning system (TPS). The first plan used a single pencil beam of energy 153.2 MeV to provide a range of 16 cm in water. Four regions of the dosimeter were irradiated delivering doses in the peak of approximately 6, 10, 13 and 19 Gy(RBE) by rotating the dosimeter between spot deliveries. The second plan used a single passively scattered field with a spread out Bragg peak (SOBP) of 4 cm. This plan delivered approximately 10 Gy(RBE). The dosimeters were analyzed using an optical CT scanner. The measured optical densities were converted to dose via a calibration curve, exported to the CERR environment and fused to the treatment plan. Dose distributions were scaled to the SOBP plan. Dose profiles were taken along the axis of each spot and the SOBP and perpendicularly across the SOBP. Results: The dose measured in the peak of single spot irradiations increased proportionally to the MU setting. The distal falloff was steeper than predicted by the TPS. The cross profiles for the SOBP plan matched within 2 mm with the TPS. The depth profile was noisy within the modulated area. Noise decreased as dose increased for both dosimeters Conclusions: This formulation of PRESAGE shows promise as a 3D dosimeter for proton therapy. A dose calibration specific to protons will facilitate further analysis and enable measurement of complex distributions.

3D Dosimetry for Small Irregular Proton Fields Using a New PRESAGE Dosimeter. By L Zhao, J Newton, J Adamovics, M Oldham, C Cheng, and I Das From Med. Phys. 38, 3506 (2011) Purpose: Small field dosimetry is challenging that impacts patient specific QA in proton beam therapy due to detector size, aperture scattering and disequilibrium. Therefore, itis urgent to develop an accurate and efficient method to quantify the uncertainty of 3D dosimetry of small fields. This study investigated the feasibility of using a new formula PRESAGE for 3D dosimetry of small irregular field in proton therapy. Methods: Three cylindrical shape PRESAGE dosimeters (10 cm or 4 cm in diameter, 6 cm in length) of a new formula (C304H510N20O71SBr) were irradiated with three irregular patient fields (field size 2 4 cm) either with or without range compensators, respectively. A proton range 6 cm with three different SOBP widths were used. To test the sensitivity of the dosimeter, three different dose levels, 150, 300, and 500 cgy were delivered. Uniform scanning proton beams with energy stacking were used for beam delivery. Three corresponding treatment plans created on the CMS XiO treatment planning system using pencil beam algorithm were compared with the experimental results in the form of relative dose distributions, including isodose plots, dose profiles and gamma index maps. Results: Transverse dose profile comparison showed spatial agreement within 1 2 mm. The measured depth dose results showed a sharper distal fall off compared to the calculations with negligible quenching effect (< 5%). Most differences were observed in the high dose gradient region (field edges and distal end). Majority of the data points in the target region passed the 3% dose difference and 3 mm DTA gamma analysis. Conclusions: Good agreement was observed between planned and measured 3D dose distributions. Overall, the new formula PRESAGE dosimeter was found to be suitable for verifying the 3D dose distribution for small irregular fields in proton therapy with single shot irradiation. An investigation of the response of the radiochromic dosimeter PRESAGE to irradiation by 62 MeV protons Al Nowais, Shamsa; Kacperek, Andrzej; Brunt, John N. H.; Adamovics, John; Nisbet, Andrew; Doran, Simon J. Journal of Physics: Conference Series (2010), 250 Measurements of the 62 MeV proton beam at the Clatterbridge Center for Oncol. using the radiosensitive plastic PRESAGE have previously shown a dependence of the dosimeter sensitivity (dose-response slope) on the linear energy transfer (LET) of the ionising particles. This work focuses on a possible explanation in terms of track structure theory (TST). Exptl. measurements of highly irradiated PRESAGE samples established the D37 parameter of the theory to be of the order of 1000 Gy. Initial attempts at applying the theory showed good agreement of the theor. and exptl. values.

Determination of the depth dose distribution of proton beam using PRESAGE dosimeter Zhao, L.; Das, I. J.; Zhao, Q.; Thomas, A.; Adamovics, J.; Oldman, M. Journal of Physics: Conference Series (2010), 250 PRESAGE dosimeter dosimeter has been proved useful for 3D dosimetry in conventional photon therapy and IMRT. Our objective is to examine the use of PRESAGE dosimeter for verification of depth dose distribution in proton beam therapy. Three PRESAGE samples were irradiated with a 79 MeV unmodulated proton beam. Percent depth dose profile measured from the PRESAGE dosimeter is compared with data obtained in a water phantom using a parallel plate Advanced Markus chamber. The Bragg-peak position detd. from the PRESAGE is within 2 mm compared to measurements in water. A preliminary analysis of LET effects in the dosimetry of proton beams using PRESAGE and optical CT A preliminary analysis of LET effects in the dosimetry of proton beams using PRESAGE and optical CT Al-Nowais, S.; Doran, S.; Kacperek, A.; Krstajic, N.; Adamovics, J.; Bradley, D. Applied Radiation and Isotopes (2009),67(3),415-418. PRESAGE is a solid dosimeter based on a clear polyurethane matrix doped with radiochromic components (leuco dyes). On exposure to ionizing radiation a color change is generated in the dosimeter, and hence an optical absorption or optical d. change that can be read out by optical CT. The main focus of present investigations has been to investigate the possible LET dependence of PRESAGE to the dose deposited at the Bragg maxima using proton beam absorbed dose measurements, and the linearity of response of the dosimeter. Proton irradiations were performed using the UK proton beam facility. Measurement of a 200 MeV proton beam using a polyurethane dosimeter Heard, Malcolm; Adamovics, John; Ibbott, Geoffrey Journal of Physics:Conference Series (2006),56,228-230. PRESAGE is a 3-dimensional polyurethane dosimeter contg. a leuco dye that generates a color change when irradiated and responds monotonically to both photons and electrons. The response of PRESAGE to proton beam radiotherapy was studied. The under-response of polymer gels in the distal region of the spread-out Bragg peak (SOBP) was obsd. in a previous study. The under-response of the PRESAGE is expected because free radicals can recombine in the high LET region resulting in fewer radicals for initiation of the response in the dosimeter. This applies particularly to the distal edge of the SOBP.