ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

Similar documents
Physical Principles of Ultrasound

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

What is Ultrasound? What is Ultrasound? B A. Basic Principles of Ultrasound. Basic Principles of Ultrasound. Basic Principles of Ultrasound

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Preamble (disclaimer)

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions.

Ultrasound Physics & Terminology

Ultrasound Principles cycle Frequency Wavelength Period Velocity

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Concepts of Imaging and Knobology

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

Basic Training Programme. 16 Februrary 2018, ROTTERDAM. Pre and Post-Course Test Answers

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Dr Emma Chung. Safety first - Physical principles for excellent imaging

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Introduction to Biomedical Imaging

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

2015 ARDMS Sonography Principles & Instrumentation Job Task Analysis Summary Report

CONTENTS. Test Number cpd Tanya Reynolds (Nat. Dip. Diag. Rad., B. Tech. Diag. Rad., B. Tech. Ultrasound)

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

Basic Physics of Ultrasound and Knobology

Ultrasound Physics and Knobology Alan Macfarlane. Consultant Anaesthetist Glasgow Royal Infirmary

Ultrasound 10/1/2014. Basic Echocardiography for the Internist. Mechanical (sector) transducer Piezoelectric crystal moved through a sector sweep

Supplement (videos)

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426)

The Value. Ultrasound System. Professional Concept for. Women s. Health

ULTRASOUND NOMENCLATURE

Basic Physics of Ultrasound in Transesophageal Echocardiography

Ultrasound Physics & Doppler

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

The 2 nd Cambridge Advanced Emergency Ultrasound Course

Ultrasonic Testing Level I:

Terminology Tissue Appearance

Basic Ultrasound Physics Board Review Questions

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

Exam Practice Guide. Units 1 & 2 Physics: Detailed Study 5 - Investigations: Medical physics Examination Questions

Introduction & Physics of ED Ultrasound. Objectives. What? - Limited Studies. Who? - ED Docs

Point-of-Care Ultrasound: An Introduction

Underwater Acoustic Measurements in Megahertz Frequency Range.

DOW-RAD, DOW DIAGNOSTIC COMPLEX, DUHS TRAINING PROGRAM HANDBOOK 2013

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

Ultrasound: Past and Present. Lecturer: Dr. John M Hudson, PhD

Linear Ultrasonic Wave Propagation in Biological Tissues

What is Ultrasound? Resolution Image production Attenuation Imaging modes Ultrasound artifacts... 7

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney

1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material

Medical Imaging. Ultrasound Imaging

WELCOME! Introduction to Bedside Ultrasound

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

Descriptions of NDT Projects Fall 2004 October 31, 2004

Ultrasonic Testing of Composite Structures

RPVI Exam Review ecourse

Ultrasound in Medicine

Medical Imaging. By: Engr. Joseph Ronald Canedo

Table of contents. Foreword. Preface. 1 Introduction Historical Perspective 00

Ultrasound in Anesthesia: Applying Scientific Principles to Clinical Practice

Ultrasound System DUS ULT. Ultrasound. September 2016 DUS 7000 Rev. 03

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

Feng Xiujuan National Institute of Metrology (NIM),China

High resolution ultrasound scanner for skin imaging

Introduction to Ultrasound Guided Region Anesthesia

Emergency Medicine Interest Group (EMIG) 2016

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRAINING PHANTOMS

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Aixplorer MultiWave Ultrasound System An Innovation in Breast Ultrasound Imaging

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

Chapter 3 Physical Principles of Ultrasound of the Male Genitalia

Chapter 14. Imaging Artifacts

Women s Lifetime Partner

Lectures on Medical Biophysics Dept. Biophysics, Medical faculty, Masaryk University in Brno

Insight, Intelligence, and more

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Physical Principles of Ultrasound

Ultrasound Knobology

GE Healthcare. Logiq P5 Premium

ALPINION MEDICAL SYSTEMS We are Ultrasound Professionals

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

Ultrasonography of the Neck as an Adjunct to FNA. Nicole Massoll M.D.

Principles of echocardiography for the anesthesiologist.

The complete, portable patient care solution

DMS-2350: SONOGRAPHIC INSTRUMENT/PHYSICS

Ultrasound guidance in regional anesthesia has

Improved ultrasound-based navigation for robotic drilling at the lateral skull base

Chapter 1. Principles of medical ultrasound. Overview. Background history: first steps to the piezo-electric effect.

ACUSON X150 Ultrasound System. Transducer Options Release 1.0

Image optimization for critical care US

ACUSON X500 Ultrasound System. Transducers

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

NCVH. Ultrasongraphy: State of the Art Vein Forum 2015 A Multidisciplinary Approach to Otptimizing Venous Circulation From Wounds to WOW

Reliable versatility. Philips HD5 ultrasound system

Critical Care Ultrasound Study Notes

Transcription:

1 OB/Gyn (Core) Ultrasound Principles of Ultrasound Physics and Instrumentation Nathan Pinkney, BS, CDOS Philadelphia College of Osteopathic Medicine 2016 ULTRASOUND CATEGORIES OF SOUND INFRASOUND = below 20 Hz AUDIBLE SOUND = 20 Hz to 20 khz ULTRASOUND = above 20 khz o Medical Diagnostic Ultrasound = above 1 MHz Material SOUND VELOCITIES Meters per second Air 330 Pure Water 1430 Fat 1450 Soft Tissue 1540 Muscle 1585 Bone 4080 PIEZOELECTRIC EFFECT PIEZOELECTRIC EFFECT Electrical energy TRANSMIT Electrical energy to mechanical energy Piezoelectric element (s) RECEIVE Mechanical energy to electrical energy Transmitted pulse Returning echo Mechanical energy Interface

2 ACOUSTIC IMPEDANCE INTERFACE MATERIALS & ECHO STRENGTH (Rayls) Air 400 Fat 1,380,000 Water 1,430,000 Soft Tissue 1,630,000 Muscle 1,700,000 Bone 7,800,000 Soft Tissue to Muscle - Weak (1%) Fat to Soft Tissue - Weak (1%) Soft Tissue to Bone - Strong (50%) Blood to Plaque - Strong (50%) Soft Tissue to Air - Very Strong (100%) GRAY SCALE ASSIGNMENT RESOLUTION Interfaces not closely spaced GOOD Closely spaced Closely spaced GOOD POOR AXIAL RESOLUTION LATERAL RESOLUTION SCANNED STRUCTURE DISPLAYED IMAGE SCANNED STRUCTURE DISPLAYED IMAGE

RESOLUTION & PENETRATION HIGH-FREQUENCY TRANSDUCERS BETTER RESOLUTION GREATER ATTENUATION POORER PENETRATION RESONANT FREQUENCY The fundamental frequency of a transducer LOW-FREQUENCY TRANSDUCERS POORER RESOLUTION LESS ATTENUATION BETTER PENETRATION PIEZOELECTRIC ELEMENT THICKNESS Increase Decrease RESONANT FREQUENCY Decrease Increase TRANSDUCER FREQUENCIES 2 MHz 2.25 MHz 2.5 MHz 3 MHz 3.5 MHz 4 MHz 5 MHz 7 MHz 7.5 MHz 10 MHz 12 MHz 15 MHz TRANSDUCER FREQUENCY ATTENUATION PENETRATION HALF INTENSITY DEPTH Increase Increase Decrease Decrease Decrease Decrease Increase Increase ATTENUATION ATTENUATION COEFFICIENT: (in tissue) a = - 0.5 db per cm per MHz HALF INTENSITY DEPTH: (in tissue) H.I.D. = 6 divided by frequency IN TISSUE: Attenuation = 0.5 db per cm per MHz H.I.D. = 6 Frequency Frequency -db per cm Half-Intensity-Depth 2 MHz 1 3 cm 2.25 MHz 1.125 2.67 cm 2.5 MHz 1.25 2.4 cm 3 MHz 1.5 2 cm 3.5 MHz 1.75 1.71 cm 4 MHz 2 1.5 cm 5 MHz 2.5 1.2 cm 7 MHz 3.5 0.86 cm 7.5 MHz 3.75 0.8 cm 10 MHz 5 0.6 cm 15 MHz 7.5 0.4 cm ULTRASOUND BIOEFFECTS HEAT (Thermal) CAVITATION (Mechanical) Stable Transient 3

4 ALARA Pulse-echo Imaging Voltage Sound As low as reasonably achievable TRANSDUCER EXCITATION AND OUTPUT POWER TIMING TRANSMITTER TRANSMIT POWER OUTPUT ACOUSTIC POWER ENERGY OUTPUT PRF The frequency of the sound is not affected. Pulse-repetition frequency is not the same as transducer frequency. RECEIVER TIME GAIN COMPENSATION TGC GAIN MASTER GAIN OVERALL GAIN Receiver controls do not affect the patient

5 OBSTETRICAL IMAGE Display Modes B-SCAN B-SCAN (2-D) M-MODE PATIENT-ORIENTED B-SCAN PLANES OBSTETRICAL IMAGES 2D 3D/4D 3D/4D Freehand 3D, often called manual 3D uses a standard 2D transducer and produces a static volumetric image after the transducer is slowly moved along a scan plane. Ultrasound Transducers Automatic 3D requires a dedicated transducer and can produce a volumetric image from a fixed transducer position. 4D also requires a dedicated transducer, but the volumetric image is displayed in real-time.

6 FLAT-LINEAR ARRAY (linear array) Labeled L FLAT-LINEAR ARRAY (linear array) FLAT-LINEAR ARRAY (linear array) FLAT-LINEAR ARRAY (linear array) Labeled C EMBRYO

7 FIBROID UTERUS EMBRYO AND OVARIAN CYST FETUS

8 FETUS ENDOVAGINAL TRANSDUCER SAGITTAL SCAN PLANES TRANSABDOMINAL ENDOVAGINAL ENDOVAGINAL UTERUS PHASED ARRAY (electronically steered) PHASED ARRAY (electronically steered) Labeled P or S FETAL HEAD

9 PHASED ARRAY (electronically steered) PHASED ARRAY (electronically steered) FETUS ENDOVAGINAL TRANSDUCER PHASED ARRAY (electronically steered) PHASED / VECTOR ARRAY (trapezoidal array) Labeled V ENDOVAGINAL UTERUS PHASED / VECTOR ARRAY (trapezoidal array) ULTRASOUND ARTIFACTS REVERBERATION ENHANCEMENT SHADOWING FETUS

10 Doppler Imaging DOPPLER DOPPLER TRANSDUCER SAME FREQUENCY TRANSDUCER LOWER FREQUENCY During Doppler operation, the reflected sound has the same frequency as the transmitted sound if the blood is stationary. During Doppler operation, the reflected sound has a lower frequency if the blood is moving away from the sound source.

11 DOPPLER SPECTRAL & COLOR-FLOW DOPPLER TRANSDUCER HIGHER FREQUENCY During Doppler operation, the reflected sound has a higher frequency if the blood is moving toward the sound source. KEY ITEMS FOR REVIEW #1 Frequencies used for medical diagnostic ultrasound are: #1 Frequencies used for medical diagnostic ultrasound are: above 1 MHz CATEGORIES OF SOUND INFRASOUND = below 20 Hz AUDIBLE SOUND = 20 Hz to 20 khz ULTRASOUND = above 20 khz o Medical Diagnostic Ultrasound = above 1 MHz

#2 #2 The average sound velocity in soft tissue is: The average sound velocity in soft tissue is: 1540 meters per second Material SOUND VELOCITIES Meters per second Air 330 Pure Water 1430 Fat 1450 Soft Tissue 1540 Muscle 1585 #3 High frequency transducers provide improved resolution and: Bone 4080 #3 High frequency transducers provide improved resolution and: poor penetration RESOLUTION & PENETRATION HIGH-FREQUENCY TRANSDUCERS BETTER RESOLUTION GREATER ATTENUATION POORER PENETRATION LOW-FREQUENCY TRANSDUCERS POORER RESOLUTION LESS ATTENUATION BETTER PENETRATION 12

#4 #4 Major categories of ultrasound bioeffects are heat and: Major categories of ultrasound bioeffects are heat and: cavitation ULTRASOUND BIOEFFECTS #5 HEAT (Thermal) Two basic scanning formats are: CAVITATION (Mechanical) Stable Transient #5 Two basic scanning formats are: linear and sector 13

14