Durable outcomes. Proven performance.

Similar documents
All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

A New EVAR Device for Infrarenal AAAs

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

Access More Patients. Customize Each Seal.

Challenging anatomies demand versatility.

My personal experience with INCRAFT in standard and challenging cases

Talent Abdominal Stent Graft

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

LOWERING THE PROFILE RAISING THE BAR

Indications for use. Contraindications within the United States

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Durability of The Endurant Stent-Graft through 5 Years

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

US clinical trial update on the Gore Excluder iliac branch endoprosthesis (IBE)

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Aortic stents, types, selection, tricks in deployment.

How effective is preservation when viewed through a clinical and economic lens?

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Vascular V12. Covered Stent. The New Standard of Care

Hostile Proximal Neck: A New Conformable EVAR Device

Right Choice for Right Angles

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

FROM THE EVERYDAY TO THE EXTRAORDINARY

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE)

TriVascular Ovation Prime Abdominal Stent Graft System

Ancillary Components with Z-Trak Introduction System

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

2015 Clinical Update Endovascular Systems for AAA Repair

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Maximize Control. Minimize Migration.

Introduction What Causes Peripheral Vascular Disease? How Do Doctors Treat Peripheral Vascular Disease?... 9

EVAS using Nellix in my practice Where are we today?

Early Experience with the GORE EXCLUDER Iliac Branch Endoprosthesis

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Considerations for a Durable Repair

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

The clinical update for the Zenith AAA Endovascular Graft has included results from the Zenith AAA Endovascular Graft multi-center clinical study,

Proven Performance Through Innovative Design *

14F OD Ovation Abdominal Stent Graft System

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

We Catch. What Others Miss

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

Introduction 3. What is Peripheral Vascular Disease? 5. What Are Some of the Symptoms of Peripheral Vascular Disease? 6

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

GORE TAG Thoracic Endoprosthesis ANNUAL CLINICAL UPDATE SEPTEMBER 2018 Abstract. Section I GORE TAG Device Clinical experience. Section II Conformable

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

From 1996 to 1999, a total of 1,193 patients with

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

Important Update to Field Safety Notice Nellix EndoVascular Aneurysm Sealing System Updated Instructions for Use (IFU)

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Endovascular options of treating iliac aneurysms

EVAS is Associated with Lower All-Cause Mortality

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

Why Nellix? Treating Concomitant Common Iliac Aneurysms

BC Vascular Day. Contents. November 3, Abdominal Aortic Aneurysm 2 3. Peripheral Arterial Disease 4 6. Deep Venous Thrombosis 7 8

Expanding to every demand: The GORE VIABAHN VBX Stent Graft

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Finally, the Control You Need to Deliver Accurate Treatment

FLEXIBLE, BALOON EXPANDABLE

2014 ANNUAL CLINICAL UPDATE. TriVascular Inc. Ovation and Ovation Prime Abdominal Stent Graft Systems

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

The Distal Seal Zone in AAA Repair A facet of EVAR that is not to be overlooked.

INCRAFT system: Update from the Pivotal INSPIRATION Study

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

Influence of patient selection and IFU compliance on outcomes following EVAS

Anatomical challenges in EVAR

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Prospective Study of the E-liac Stent Graft System in Patients with Common Iliac Artery Aneurysm: 30-Day Results

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

EVAS How does this Impact EVAR Therapy

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

First in Human Experience with the Gore Conformable Excluder Endoprosthesis

Abdominal Aortic Aneurysm 가천대길병원 이상준

Santi Trimarchi, MD, PhD Vascular Surgeon Thoracic Aortic Research Center, Director IRCCS Policlinico San Donato University of Milan

Internal iliac artery aneurysms: When to intervene and outcomes of EVAR

Preliminary Data from the Gore EXCLUDER Thoracoabdominal Branch Endoprosthesis Early Feasibility Study

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Quick Reference Guide

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster

Treating very short necks ( 4mm <10mm) using the Endurant stent graft + EndoAnchors: 1-year results and current insights

Nellix Endovascular System: Clinical Outcomes and Device Overview

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Improving Endograft Durability with EndoAnchors

Transcription:

Durable outcomes. Proven performance. GORE EXCLUDER AAA Endoprosthesis GORE EXCLUDER Iliac Branch Endoprosthesis

GORE EXCLUDER AAA Endoprosthesis The most-studied* EVAR stent graft designed for durable outcomes. The trusted performance of the GORE EXCLUDER Device is paired with the intuitive GORE C3 Delivery System to provide optimal infrarenal seal and reliable results, even in more challenging anatomies. Proven Performance. Results from the Global Registry for Endovascular Aortic Treatment (GREAT) 3,273 Patients through 3 years of follow-up** 96.0 % Freedom from device-related reintervention 93.4 % Freedom from all reintervention 0.0 % Migration 1.4 % Type I / III endoleak 0.5 % Limb occlusion GORE C3 Delivery System Repositionable to obtain optimal seal Unique ability to reconstrain the proximal end and reposition for ideal placement More opportunities to maximize infrarenal seal

GORE EXCLUDER Iliac Branch Endoprosthesis U.S. IDE Clinical Trial now has 2-year follow-up data for all patients from primary enrollment (n = 63). 2-year data 100 % Patency External iliac artery We designed this all-in-one system exclusively for use in the iliac arteries. It is the only FDA-approved, off-the-shelf iliac branch solution. Preservation matters: Recommended treatment 1,2 to sustain quality of life Performs as promised: High patency 3, conformability, and durability 95.1 % Patency Internal iliac artery 93.7 % Freedom from reintervention 0 % Buttock claudication 0 % New onset erectile dysfunction 98.3 % Freedom from CIAA enlargement (> 5 mm) Pre-cannulated internal iliac gate and bi-femoral delivery for ease-of-use Low profile (16 Fr) delivery for enhanced vessel access and trackability Two-staged repositionable deployment for precise placement of the iliac component 152 minutes Procedure time 114 ml Contrast used 40 minutes Fluoro time 95.2 % Technical success

Trusted design. Trusted legacy. 4 5 The GORE EXCLUDER Device family has evolved based on what we have learned from over 20 years of experience in EVAR. GORE EXCLUDER AAA Endoprosthesis Worldwide experience More than 300,000 patients treated with GORE EXCLUDER AAA Endoprosthesis More than 10,000 patients treated with GORE EXCLUDER Iliac Branch Endoprosthesis 1 Durability 1 Sutureless construction Expanded PTFE graft technology on luminal and abluminal surfaces 2 Advanced sinusoidal stent design Enhances flexibility and long-term conformability GORE EXCLUDER Iliac Branch Endoprosthesis 3 3 Proprietary eptfe film layers Low permeability with abrasion-resistant properties Conformability in tortuous anatomies 4 Sealing cuff Engineered to provide security against endoleaks 2 5 Active infrarenal fixation Anchors for active fixation are engineered to provide migration resistance

Physician collaboration and unwavering commitment. When we join with our partners in the medical community, we work together to advance patient care. With the only FDA-approved iliac branch solution, and durable outcomes with more than 20 years of EVAR experience, the GORE EXCLUDER Device family offers solutions physicians trust and patients count on. Learn more at goremedical.com/aortic The GORE EXCLUDER Iliac Branch Endoprosthesis is to be used in conjunction with the GORE EXCLUDER AAA Endoprosthesis and is not intended to be used on its own. * Based on company-sponsored trials and registries shown on clinicaltrials.gov for currently available stent grafts. ** GREAT. n=3,273. To calculate the overall event rates from procedure through end of study period, all subjects who could have had events, regardless of length of follow-up, were included. For outcome data, GREAT only collects site reported serious adverse events. One peri-procedural migration reported. Zero migrations reported during follow-up through 3 years. Defined as successful implantation with lack of endoleaks. Based on the number of Trunk-Ipsilateral Legs distributed. Based on the number of Iliac Branch Components distributed. 1. Chaikof EL, Dalman RL, Eskandari MK, et al. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. Journal of Vascular Surgery 2018;67(1):2-77.e2. 2. Moll F.L., Powell J.T., Fraedrich G., et al; European Society for Vascular Surgery. Management of abdominal aortic aneurysms clinical practice guidelines of the European Society for Vascular Surgery. European Journal of Vascular & Endovascular Surgery 2011;41(Supplement 1):S1-S58. 3. Schneider D. B. One-year U.S. results of GORE EXCLUDER Iliac Branched Endograft: Advantages and limitations. Presented at the 42nd Annual Symposium on Vascular and Endovascular Issues, Techniques, Horizons (VEITHsymposium); November 17-21, 2015; New York, NY. INDICATIONS FOR USE IN THE US: Iliac Branch and Internal Iliac Components. The GORE EXCLUDER Iliac Branch Endoprosthesis (IBE) is intended to be used with the GORE EXCLUDER AAA Endoprosthesis to isolate the common iliac artery from systemic blood flow and preserve blood flow in the external iliac and internal iliac arteries in patients with a common iliac or aortoiliac aneurysm, who have appropriate anatomy, including: Adequate iliac / femoral access; minimum common iliac diameter of 17 mm at the proximal implantation zone of the IBE; external Iliac artery treatment diameter range of 6.5 25 mm and seal zone length of at least 10 mm; internal iliac artery treatment diameter range of 6.5 13.5 mm and seal zone length of at least 10 mm; adequate length from the lowest major renal artery to the internal iliac artery to accommodate the total endoprosthesis length, calculated by adding the minimum lengths of required components, taking into account appropriate overlaps between components. GORE EXCLUDER AAA Endoprosthesis Components used in conjunction with GORE EXCLUDER Iliac Branch Endoprosthesis: Trunk-Ipsilateral Leg Component. The Trunk- Ipsilateral Leg is intended to provide proximal seal and fixation for the endovascular repair of the aneurysm. Contralateral Leg Endoprosthesis Component. The Contralateral Leg Endoprosthesis is intended to bridge the GORE EXCLUDER Device Trunk-Ipsilateral Component to the GORE EXCLUDER Iliac Branch Endoprosthesis following deployment of the GORE EXCLUDER Iliac Branch Endoprosthesis. Additionally, the Contralateral Leg Endoprosthesis is intended to be used for distal extension of the Iliac Branch Component in the external iliac artery. The Iliac Branch Component can treat external iliac artery diameters up to 13.5 mm. This ability to extend the Iliac Branch Component distally with any Contralateral Leg Endoprosthesis expands the external iliac artery treatment range up to 25 mm. Aortic Extender Endoprosthesis and Iliac Extender Endoprosthesis Components: The Aortic and Iliac Extender Endoprostheses can be used after deployment of the GORE EXCLUDER Iliac Branch Endoprosthesis and GORE EXCLUDER AAA Endoprosthesis. These extensions are used when additional length and / or sealing for aneurysmal exclusion is desired. CONTRAINDICATIONS: The GORE EXCLUDER Iliac Branch Endoprosthesis is contraindicated in: Patients with known sensitivities or allergies to the device materials. All components of the GORE EXCLUDER Iliac Branch Endoprosthesis and the GORE EXCLUDER AAA Endoprosthesis contain eptfe, FEP, nitinol (nickel-titanium alloy), and gold. Patients with a systemic infection who may be at increased risk of endovascular graft infection Refer to Instructions for Use at goremedical.com for a complete description of all warnings, precautions and adverse events. Products listed may not be available in all markets. GORE, C3, EXCLUDER, and designs are trademarks of W. L. Gore & Associates. 2018 W. L. Gore & Associates, Inc. AX0271-EN1 MAY 2018 W. L. Gore & Associates, Inc. Flagstaff, AZ 86004 +65.67332882 (Asia Pacific) 00800.6334.4673 (Europe) 800.437.8181 (United States) 928.779.2771 (United States) goremedical.com