Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis

Similar documents
AlignEUSummit2015_PPT Template- GEN SESSION_

Stress distribution in the mandibular central incisor and periodontal ligament while opening the bite: A finite element analysis

Three-dimensional FEM analysis of stress distribution in dynamic maxillary canine movement

B U J O D. Original Research

A finite element analysis of the effects of archwire size on orthodontic tooth movement in extraction space closure with miniscrew sliding mechanics

Title Page. Nonlinear Dependency of Tooth Movement on Force System Directions

A Finite Element Model of Apical Force Distribution From Orthodontic Tooth Movement

Finite Element Analysis of Dental Implant as Orthodontic Anchorage

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

A DAMAGE/REPAIR MODEL FOR ALVEOLAR BONE REMODELING

Controlled Space Closure with a Statically Determinate Retraction System

Prediction of optimal bending angles of a running loop to achieve bodily protraction of a molar using the finite element method

Design of Customised Orthodontic Devices by Digital Imaging and CAD/FEM Modelling

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

6. Timing for orthodontic force

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One

The management of impacted

Class II Correction with Invisalign Molar rotation.

With judicious treatment planning, the clinical

Treatment of a Patient with Class I Malocclusion and Severe Tooth Crowding Using Invisalign and Fixed Appliances

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY

KJLO. A Sequential Approach for an Asymmetric Extraction Case in. Lingual Orthodontics. Case Report INTRODUCTION DIAGNOSIS

Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis

SmartForce Clinical Innovations

The Tip-Edge appliance and

IS THE PALATE AN OPTIMAL SITE FOR MINISCREW PLACEMENT?

Enhanced Control in the Transverse Dimension using the Unitek MIA Quad Helix System by Dr. Sven G. Wiezorek

In biocreative therapy (C-therapy), torque control

Anterior Open Bite Correction with Invisalign Anterior Extrusion and Posterior Intrusion.

Frictional and Biomechanical Forces and Biological Effects of a Trapezoidal Versus Rectangular Bracket

Class II correction with Invisalign - Combo treatments. Carriere Distalizer.

A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case

In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics.

Molar intrusion with skeletal anchorage ; from single tooth intrusion to canting correction and skeletal open bite

SmartForce features and Attachments. Designed to help you treat with confidence.

ORTHOdontics SLIDING MECHANICS

Three-dimensional finite element analysis in distal en masse movement of the maxillary dentition with the multiloop edgewise archwire

The main challenge in using the natural dentition

INCLUDES: OVERVIEW ON CLINICAL SITUATIONS FREQUENTLY ENCOUNTERED IN ORTHODONTIC TREATMENTS MECHANOTHERAPY USED TO RESOLVE THESE SITUATIONS

AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain

Invisalign G4 FAQs. General:

Comparative analysis of the stress distribution in five anatomical types of maxillary central incisor

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Checklist with summary points

REPRINTED FROM JOURNAL OF CLINICAL ORTHODONTICS 1828 PEARL STREET, BOULDER, COLORADO Dr. Nanda Dr. Marzban Dr. Kuhlberg

Dental Morphology and Vocabulary

Intrusion of Incisors to Facilitate Restoration: The Impact on the Periodontium

Finite-element analysis of the center of resistance of the mandibular dentition

MemRx Orthodontic Appliances

Interdisciplinary management of Impacted teeth in an adult with Orthodontics & Free Gingival graft : A Case Report

Honing Damon System Mechanics for the Ultimate in Efficiency and Excellence Jeff Kozlowski, DDS East Lyme, CT

Dual Force Cuspid Retractor

Low-Force Mechanics Nonextraction. Estimated treatment time months (Actual 15 mos 1 week). Low-force mechanics.

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD

RESEARCH ARTICLE /jp-journals

Longitudinal Measurements of Tooth Mobility during Orthodontic Treatment Using a Periotest

A finite element simulation of initial movement, orthodontic movement, and the centre of resistance of the maxillary teeth connected with an archwire

Cases: A Finite Element Analysis

Initial Displacement of Teeth as an Indicator of Ideal Force System for En Masse Retraction Using Mini Implant A FEM Study

Orthodontic Displacement and Stress Assessment: A Finite Element Analysis

AN EXPERT SYSTEM FOR STRESS ANALYSIS OF HUMAN TEETH. Qiong Li. Dissertation. Submitted to the Faculty of the. Graduate School of Vanderbilt University

04 Inserting the HYCON TUBE

Dental Anatomy and Occlusion

Case Report: Long-Term Outcome of Class II Division 1 Malocclusion Treated with Rapid Palatal Expansion and Cervical Traction

THE MBT VERSATILE+ APPLIANCE SYSTEM

3M Incognito Appliance System extraction case study.

Effect of Intrusive Forces on Maxillary Central Incisor at Different Inclinations at Normal Bone Height A FEM Study

Influence of Attachments and Interproximal Reduction on the Accuracy of Canine Rotation with Invisalign

IJPCDR ORIGINAL RESEARCH ABSTRACT INTRODUCTION

Holy Nexus of Variable Wire Cross-section: New Vistas in Begg s Technique

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Unilateral Horizontally Impacted Maxillary Canine and First Premolar Treated with a Double Archwire Technique

education, Uzhgorod Engineering, Department of Dynamics and Resistibility of Materials, Kyiv Zaporizhzhya

Efficient Bonding Protocol for the Insignia Custom Bracket System

PERMANENT MANDIBULAR INCISORS

The Role of a High Pull Headgear in Counteracting Side Effects from Intrusion of the Maxillary Anterior Segment

ortho case report Sagittal First international magazine of orthodontics By Dr. Luis Carrière Special Reprint

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D.

Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Correction of a maxillary canine-first premolar transposition using mini-implant anchorage

Title. Author(s) Motohiro; Yoshida, Noriaki. Issue Date

Controlled tooth movement to correct an iatrogenic problem

Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis

Measurements of the torque moment in various archwire bracket ligation combinations

Invisalign technique in the treatment of adults with pre-restorative concerns

Gentle-Jumper- Non-compliance Class II corrector

6610 NE 181st Street, Suite #1, Kenmore, WA

Characterizing constraining forces in the alignment phase of orthodontic treatment

There had been controversies concerning how to achieve maximum anchorage in the first premolar extraction cases.

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

Response of the maxillary dentition to a statically determinate one-couple system with tip-back mechanics: A prospective clinical trial

Alveolar Bone Remodeling and Development after Immediate Orthodontic Root Movement

The Science Behind The System Clinical Abstracts, Volume 2

Clinical efficacy of Invisalign treatment with weekly aligner changes: Two case reports

invisalign clinical results

Cephalometric Analysis

Modelling of temporomandibular joint and FEM analysis

Transcription:

Original Article Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis Juan Pablo Gomez a ; Fabio Marcelo Peña b ; Valentina Martínez c ; Diana C. Giraldo c ; Carlos Iván Cardona d ABSTRACT Objective: To describe, using a three-dimensional finite element (FE) model, the initial force system generated during bodily movement of upper canines with plastic aligners with and without composite attachments. Materials and Methods: A CAD model of an upper right canine, its alveolar bone and periodontal ligament, thermoformed plastic aligner, and two light-cured composite attachments were constructed. A FE model was used to analyze the effects of imposing a distal movement condition of 0.15 mm on the aligner (simulating the mechanics used to produce a distal bodily movement) with and without composite attachments. Results: In terms of tension and compression stress distribution, without composite attachments a compression area in the cervical third of the distal root surface and a tension area in the apical third of the mesial surface were observed. With composite attachments, uniform compression areas in the distal root surface and uniform tension area in the mesial root surface were observed. Compression areas in the active surfaces of the composite attachments were also observed. In terms of movement patterns, an uncontrolled distal inclination, with rotation axis between the middle and cervical root thirds, was observed without composite attachment. Distal bodily movement (translation) was observed with composite attachment. Conclusions: In a three-dimensional FE analysis of a plastic aligner system biomechanically supplementary composite attachments generate the force system required to produce bodily tooth movement; the absence of biomechanically supplementary composite attachments favors the undesired inclination of the tooth during the translation movements. (Angle Orthod. 2015;85:454 460.) KEY WORDS: Finite element; Bodily movement; Plastic aligners INTRODUCTION a Associate Professor of Biomechanics, Department of Orthodontics, Universidad Autónoma de Manizales, Manizales, Colombia. b Associate Professor, Department of Mechanics and Production, Universidad Autónoma de Manizales, Manizales, Colombia. c Orthodontic Graduate Student, Universidad Autónoma de Manizales, Manizales, Colombia. d Research Assistant, Department of Mechanics and Production, Universidad Autónoma de Manizales, Manizales, Colombia. Corresponding author: Dr Juan Pablo Gómez, Calle 12 #24-45 Apt. 101, Pereira, Colombia (e-mail: jgomez@autonoma.edu.co) Accepted: July 2014. Submitted: May 2014. Published Online: September 2, 2014 G 2015 by The EH Angle Education and Research Foundation, Inc. Using a mathematical model derived from the CAD discretization of solids in three dimensions, finite element (FE) models contribute to the understanding of biomechanics of the orthodontic devices as they permit the estimation of the stresses generated within the different tissue structures, such as alveolar bone, periodontal ligament (PDL), and teeth, during the treatment. Likewise, with the use of FE models it is possible to determine loading and displacement patterns according to the appliance used. 1 4 Bodily tooth movement in orthodontics has been widely studied and is acknowledged for its complexity, since it implies that the applied force must pass through the center of resistance of the tooth or, alternatively, require a sophisticated equivalent system of forces and 454 DOI: 10.2319/050714-330.1

ALIGNER FORCE SYSTEMS 455 moments applied to the tooth crown. 5,6 FE models have been used to simulate bodily tooth movements using bracket-based orthodontic mechanotherapy. 7 9 Thermoformed plastic aligner based orthodontic movement techniques have demonstrated limitations in the configuration of complex force systems, such as extrusion of central incisors and rotation and inclination of the canines, 10 as well as bodily tooth movement. The need to overcome these limitations has led to the development of biomechanically enhancing composite attachments bonded to the dental surface. These applications increase the aligners biomechanical capabilities by enabling the construction of more complex force systems, usually including couples or pairs. It is necessary to understand the biomechanical nature of these innovative tools in order to support their use protocols based on reliable evidence. FE models applied to new aligner-based orthodontic techniques allow a better understanding of their theoretical performance, allowing us to infer this understanding with regard to the clinical setting. For clear understanding of thermoformed aligner orthodontics, two fundamental differences between bracket-based and aligner-based biomechanics must be recognized: N In conventional orthodontic tooth movement, a force is applied to the bracket, which transmits this force to tooth structures, generating the mechanical-biological chain of events that results in displacement of the tooth. N In aligner-based tooth movement, an intentional, predetermined mismatch between the aligner and the tooth is programmed in each treatment stage, using a cast or virtual model set-up (alignment). The aligner, which corresponds to the new desired tooth position, is fitted on the dental arch, producing in each mismatch a force system that is directly transmitted to the tooth, generating a similar chain of events that results in a new position of the teeth. Although aligner-based rotation 11 and torque 12,13 movement have been explored, neither the mechanics of bodily tooth movement nor the role of the biomechanically enhancing composite attachments has been considered. The goal of this study is to describe, using a FE model, the force system and displacement patterns produced by plastic aligners in mechanics intended to produce bodily tooth movement with and without composite attachments. MATERIALS AND METHODS Two FE models were constructed, one model with composite attachments and a second model without Table 1. Properties Assigned to the Alveolar Bone, Tooth, Composite Attachments, and Plastic Aligner Material Young s Modulus, MPa Poisson Ratio Alveolar bone 13 1.37 3 10 3 0.30 Tooth 13 1.96 3 10 4 0.30 Composite attachments 12.5 3 10 3 0.36 Plastic aligner 528 0.36 composite attachments. A comparison was established between the two models, considering tension-compression stress patterns in PDL and tooth displacement patterns. For simulation of the involved structures, their physical characteristics were determined in the following manner: N Alveolar bone: A linear elastic isotropic and homogeneous behavior was assumed and mechanical properties were obtained from cancellous bone values from previous studies. 13 Differences in rigidity between different bone types were not contemplated, as they were not considered relevant to the objectives of the study (Table 1). N Tooth (upper right canine): A linear elastic isotropic and homogeneous behavior was assumed and mechanical properties were obtained from previous studies. 13 Differences in rigidity among enamel, dentin, and cement were not contemplated, as they were not considered relevant to the objectives of the study (Table 1). N Composite attachments: Assumed as an isotropic homogeneous linear elastic behavior, with mechanical properties referred by the manufacturer 14 (Filtek TM P60, 3M ESPE, 3M, St. Paul, MN, USA) (Table 1). Their location, size, and shape were determined by simulating a case of attachments designed for root control (Optimized Root Control AttachmentsH) of an upper right canine from a randomly selected InvisalignH (Align Technology, San Jose, Calif) case. N PDL: Assumed to be a nonlinear isotropic elastic and homogeneous material, with a stress-strain function based on the data reported in Toms and Eberhardt 15 as MP1 (Figure 1). N Thermoplastic aligner: A linear elastic isotropic and homogeneous behavior was assumed. The value of Young s Modulus (Table 1) was established after performing compression tests (using an InstronH Universal Testing Machine) on flat samples extracted from a plastic aligner. The Poisson Ratio was assumed to be 0.36, which is typical of polymers. 16 Construction of the Model CAD model. The CAD model of the tooth was obtained from three-dimensional (3D) scanning digitalization of an upper right human canine.

456 GOMEZ, PEÑA, MARTÍNEZ, GIRALDO, CARDONA Table 2. Number of Nodes and Elements of the Components of the Finite Element Model Component No. of Elements No. of Nodes Tooth 2225 4065 Attachments 434 949 Aligner segment 3150 6427 Bone 3834 6831 Periodontal ligament 3620 7302 Figure 1. Nonlinear properties of the periodontal ligament. The CAD geometry of bone, PDL, attachments, and aligner was constructed, using a top-down assembly feature of SolidWorksH software, from the CAD model of the tooth, as shown in Figure 2. The aligner segment was modeled following the tooth anatomy, with an average thickness of 0.3 mm. The average thickness of the modeled PDL was 0.2 mm. Subsequently the CAD assembly was imported to ANSYS 14.5H FE software. Meshing. The model meshing was constructed with tetrahedral elements. The number of nodes and elements for each component of the model are shown in Table 2. Contact conditions. A rigid union condition without relative displacement (bonded) was established in ANSYS 14.5H in the following interfaces: ligament-bone, tooth-ligament, and tooth-attachments. A Coulomb friction condition was established in contact interfaces between the aligner and tooth crown surface and attachments, with a friction coefficient of m 5 0.2, similar to values reported by Ramalho and Vale 17 in an in vitro wear test for enamel against composite. 17 Boundary Conditions and Restrictions A fixed support condition was established at the bone base, away from the areas of interaction between the surrounding bone and the tooth. Simulation of tooth movement. For coherent FE simulation of the effect of one of the treatment stages with plastic aligners on an individual tooth, one must consider a sequential difference between the FE model and the clinical setting. N In a clinical setting, for effective aligner-based tooth movement a predetermined mismatch between the tooth and the aligner (in this case, a distal bodily movement of the canine) would be programed in the plastic aligner, which is subsequently positioned Figure 2. CAD model assembly: (1) Alveolar bone, (2) Periodontal ligament, (3) Tooth, (4) Composite attachments, and (5) Plastic aligner. Figure 3. The effect of one treatment stage (aligner) was simulated by distally displacing the aligner segment 0.15 mm in the FE model.

ALIGNER FORCE SYSTEMS 457 Figure 4. (a) Tension-compression patterns at PDL, in a model without composite attachments. (b) Tension-compression patterns at PDL, in a model with composite attachments. actively on the dental arch, initiating the force system that produces the desired tooth movement, strictly limited to the preset mismatch. N In this FE simulation of a clinical event, a displacement of 0.15 mm in the distal direction was imposed on the simulated thermoplastic aligner segment that was previously incorporated passively on the tooth crown (Figure 3). RESULTS The 3DFE model showed the following: Figure 5. (a) Displacement patterns at the PDL in a model without composite attachments. (b) Displacement patterns at the PDL in a model without composite attachments. 1. Tension-compression patterns at the PDL, in the model without composite attachments: (a) Two localized compression areas (blue in Figure 4a) in disto-cervical and meso-apical areas. (b) Two localized tension areas (red in Figure 4a) in mesocervical and disto-apical areas. 2. Tension-compression patterns at the PDL with composite attachments: (a) A broad compression area (blue in Figure 4b) in all distal surfaces. (b) A broad tension area (red in Figure 4b) in all mesial surface.

458 GOMEZ, PEÑA, MARTÍNEZ, GIRALDO, CARDONA Figure 6. Equivalent stress patterns produced by aligner on active surfaces of attachments. Figure 7. Resultant force system acting on the tooth; 286 g net force (a) in distal direction, 3062 g 3 mm net counterclockwise moment (b). 3. Displacement patterns without composite attachments: The displacement of the model without attachments was equivalent to typical uncontrolled distal crown tipping (Figure 5a). 4. Displacement pattern with composite attachments: The displacement of the model with attachments was equivalent to typical distal bodily movement, as shown in Figure 5b. DISCUSSION The results of this study validate the proposal that composite attachments help generate a force system that approximates bodily movement of the studied tooth. When the aligner segment is displaced distally without attachments, a clockwise moment and distal inclination are produced on the tooth. The presence of composite attachments helps counteract this inclination, producing a counter-moment that in turn favors a bodily movement of the canine. The magnitude of this counter-moment is dependent on the amount of displacement imposed on the aligner segment and is produced by a complex force system that includes forces on the active surfaces of the attachments. Supporting this concept, compression zones (Figure 6) were observed at the active surface of attachments (mesial aspect of the gingival attachment and distal aspect of the incisal attachment). According to the model, the force system produced on the canine as a result of displacement imposed on the aligner consists of a 2.8-N (286-g) net force in the distal direction and a 30-N 3 mm (3062-g 3 mm) counterclockwise net moment (Figure 7). Both magnitudes are considered acceptable in the current clinical setting, generating a moment to force ratio of 10.7:1, in the optimal range reported by Cattaneo et al. 18 It is important to acknowledge that the net moment is the result of the sum of moments generated in the whole system, including the moment produced by forces on the active surfaces of the attachments, which is of particular relevance to the present study. Reinforcing the previous reasoning, the absence of composite attachments (and, consequently, the absence of the counterclockwise moment they help produce) in the same type of aligner movement generates a tipping movement (clockwise rotation) in which the center of rotation is located approximately between the middle and apical thirds of the root, as seen in Figure 5a. Concurring with the objectives of the present study, this basic, single-tooth model permits an initial exploration of poorly understood aligner-based force systems, grounded on simplified inferences. Supported by this work, the inclusion of additional dental units in future FE models will permit the analysis of the complex interaction of forces between multiple teeth and the aligner that acts upon them simultaneously. An unexpected finding with this model was a marked tendency of flaring of the buccal and palatal flanks of the aligner segment during distal displacement (Figure 8). This finding is interesting because it could suggest an intrusive effect on the tooth and/or an expulsive tendency of the aligner during its function.

ALIGNER FORCE SYSTEMS 459 Figure 8. Bucco-lingual flaring of the aligner segment during distal displacement. Because of the important clinical implications of both tendencies, attention to these findings in future studies is recommended. Recommendations This study offers valuable information from the theoretical point of view, but its findings must be clinically validated to support the new systems of plastic aligners with more solid evidence. One of the limitations of the current FE model lies in the difficulty associated with simulating the large displacements on the tooth as a result of the long-term application of orthodontic forces. This occurs because such effects depend on biological events (resorption-apposition) present in variable time frames. The ability to simulate these events has not yet been incorporated into FE simulation models. The possibility of developing this application to current FE models should be explored. The experience obtained with the present onetooth FE model suggests that a complete model of the dental arch would enable the exploration of the complex interaction of forces generated during simultaneous movement of multiple dental units, allowing for a better understanding of the clinical performance within different systems of orthodontic therapy. CONCLUSIONS N In a 3D FE model, the force system resulting from imposing a distal displacement on a plastic aligner segment incorporated onto an upper canine with composite attachments closely resembles bodily tooth movement. N The absence of composite attachments in the simulation of the same displacement produced a force system compatible with uncontrolled tooth inclination. REFERENCES 1. Hayashia K, Araki Y, Uechi J, Hiroki Ohno H, Mizoguchi I. A novel method for the three-dimensional (3-D) analysis of orthodontic tooth movement calculation of rotation about and translation along the finite helical axis. J Biomech. 2002; 35:45 51. 2. Jones ML, Hickman J, Middleton J, Knox J, Volp C. A validated finite element method study of orthodontic tooth movement in the human subject. J Orthod. 2001;28:29 38. 3. Cattaneo PM, Dalstra M, Melsen B. The finite element method: a tool to study orthodontic tooth movement. J Dent Res. 2005;84:428 433. 4. McGuinness BN, Wilson AN, Jones M, Middleton J, Robertson NR. Stresses induced by edgewise appliances in the periodontal ligament a finite element study. Angle Orthod. 1992;62:15 22. 5. Kusy RP. Influence of force systems on archwire-bracket combinations. Am J Orthod Dentofacial Orthop. 2005;127: 333 342. 6. Smith RJ, Burstone CJ. Mechanics of tooth movement. Am J Orthod Dentofacial Orthop. 1984;85:294 307. 7. Geramy A. Bodily labializing lateral incisors: 3D analysis using finite element method. Acta Odontol Scand. 2013;71: 570 576. 8. Tominaga JY, Chiang PC, Ozaki H, et al. Effect of play between bracket and archwire on anterior tooth movement in sliding mechanics: a three-dimensional finite element study. J Dent Biomech. 2012;3:1758736012461269. 9. Qian Y, Fan Y, Liu Z, Zhang M. Numerical simulation of tooth movement in a therapy period. Clin Biomech (Bristol, Avon). 2008;23(suppl 1):S48 S52. Epub 2007 Oct 17. 10. Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does Invisalign work? A prospective clinical study

460 GOMEZ, PEÑA, MARTÍNEZ, GIRALDO, CARDONA evaluating the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop. 2009;135:27 35. 11. Hahn W, Engelke B, Jung K, et al. Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor. Angle Orthod. 2010;80: 239 246. 12. Hahn W, Zapf A, Dathe H, et al. Torquing an upper central incisor with aligners acting forces and biomechanical principles. Eur J Orthod. 2010;32:607 613. 13. Liang W, Rong Q, Lin J, Xu B. Torque control of the maxillary incisors in lingual and labial orthodontics: a 3- dimensional finite element analysis. Am J Orthod Dentofacial Orthop. 2009;135:316 322. 14. Filtek TM P60 Posterior Restorative Material Mechanical Properties (n.d.). MatWeb online. Available at: http:// www.matweb.com/search/datasheet.aspx?matguid5 296bb60009ce4284a72b7771a6569bb1&ckck51. Accessed March 2014. 15. Toms SR, Eberhardt AW. A nonlinear finite element analysis of the periodontal ligament under orthodontic tooth loading. Am J Orthod Dentofacial Orthop. 2003;123:657 665. 16. Osswald TA, Menges G. Materials Science of Polymers for Engineers, 2nd ed. Kempton, Germany: Honser Publishing. 2003:391. 17. Ramalho A, Vale Antunes P. Reciprocating wear test of dental composites against human teeth and glass. Wear. 2007;263:1095 1104. 18. Cattaneo PM, Dalstra M, Melsen B. Moment-to-force ratio, center of rotation, and force level: a finite element study predicting their interdependency for simulated orthodontic loading regimens. Am J Orthod Dentofacial Orthop. 2008; 133:681 689.