Magnifuse II Demineralized Bone Graft

Similar documents
POSTERIOR LUMBAR FUSION SURGICAL TECHNIQUE USING A BONE VOID FILLER. Magnifuse. Bone Graft

CD Horizon Spire. CD Horizon Spire Z PHYSICIAN REIMBURSEMENT REIMBURSEMENT GUIDE. Spinal System and. Spinal System

REIMBURSEMENT GUIDE. Sovereign. Spinal System

CD Horizon Solera 5.5/6.0mm Fenestrated Screw Set

Corex HOSPITAL OVERVIEW AND TECHNICAL ASSESSMENT TECHNOLOGY OVERVIEW NEW TECHNOLOGY REFERENCE GUIDE. Minimally Invasive Bone Harvester

CPT CODING EXAMPLES FUSION PROCEDURES. Anterior Lumbar Interbody Fusion (ALIF)

REIMBURSEMENT GUIDE. Sovereign. Spinal System

GRAFTON DEMINERALIZED BONE: FIBER TECHNOLOGY AND PERFORMANCE IMPLICATIONS

A UNIQUE APPROACH TO SACROILIAC JOINT FUSION PROCEDURES. Rialto PROCEDURE OVERVIEW. SI Fusion System

A U X I L I A R Y C O N N E C T O R S Surgical Technique


Biomechanics of Interspinous Process Fixation and Lateral Modular Plate Fixation to Support Lateral Lumbar Interbody Fusion (LLIF)

4.5 System. Surgical Technique. This publication is not intended for distribution in the USA.

ADVANCED BONE GRAFT SYSTEM OVERVIEW

Prestige LP REIMBURSEMENT GUIDE. Cervical Disc System

Marrow Cellution Bone Marrow Aspirate (BMA) and Stem Cell Harvesting System

INTELLIGENT SPINAL SYSTEM

A Fusion of Versatility, Performance and Ease.

VIPER PRIME System Cadaver Time Study

CERVICAL PROCEDURES PHYSICIAN CODING

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

TM TM Surgical Technique

Table of Contents.

I. II. SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE

Bacterin International Incorporated Mr. Howard L. Schrayer 600 Cruiser Lane Belgrade, Montana August 18, 2015

The Fusion of. Strength, Design. Performance. and

BONE VOID FILLERS CONTAINING DONATED HUMAN TISSUE The following languages are included in this packet:

THE BUILDING BLOCKS OF BONE FUSION. Medline Demineralized Bone Allografts Safe and Effective Grafting Options

Cervical Solutions. Trinnect. Hydrated Anterior Cervical Spacer System. Surgical Technique Guide

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

Royal Oak IBFD System Surgical Technique Posterior Lumbar Interbody Fusion (PLIF)

Technique Guide. chronos Strip. Osteoconductive betatricalcium phosphate ( -TCP) composite.

July 10, X-spine Systems, Incorporated David Kirschman, MD Chief Medical Officer 452 Alexandersville Road Miamisburg, Ohio 45342

CELLPLEX TCP SYNTHETIC CANCELLOUS BONE

Y o u r Id e a s En g i n e e r e d t o Li f e

DEMINERALIZED BONE MATRIX

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

Patient Information MIS LLIF. Lateral Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

OPERATIVE TECHNIQUE. anterior cervical plating system

TABLE OF CONTENTS. ShurFit Anterior Cervical Interbody Fusion (ACIF) System Overview 2. Implant Specifications 3. Instrument Features 4

U.S. MARKET FOR MINIMALLY INVASIVE SPINAL IMPLANTS

Royal Oak Cervical Plate System

PRO-DENSE BONE GRAFT SUBSTITUTE

VTI INTERLINK PEDICLE SCREW SYSTEM

Zimmer Anterior Buttress Plate System. Surgical Technique

Original Date: October 2015 LUMBAR SPINAL FUSION FOR

Technique Guide KISSloc Suture System

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

Foot and Ankle Systems Coding Reference Guide

C-THRU Anterior Spinal System

nva Anterior Lumbar Interbody Fusion System

PILLAR AL. Anterior Lumbar Interbody Fusion (ALIF) and Partial Vertebral Body Replacement (pvbr) PEEK Spacer System OPERATIVE TECHNIQUE

Silverstone Interbody System Surgical Technique

nvp Posterior Lumbar Interbody Fusion System

nvt Transforaminal Lumbar Interbody Fusion System

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

Thunderbolt. surgical technique. MIS Pedicle Screw System. Where Nimble and Secure Intersect

SPINE BIOMATERIALS Crop Bleed

The following languages are included in this packet:

Thoracolumbar Solutions. Aspen. MIS Fusion System. Surgical Technique Guide

ALLOPURE. Bicortical Allograft Wedges Specific for Evans and Cotton Osteotomies SURGICAL TECHNIQUE

Ref: Q400-09T1 EBI Spine. September 05/VS02. c/o BIOMET Spain Orthopaedics, S.L.

USS Variable Axis Screw (VAS) System. For posterior fixation of the lumbar spine.

TABLE OF CONTENTS. Vault C Anterior Cervical Discectomy 2 and Fusion (ACDF) System Overview. Implants 3. Instruments 5. Surgical Technique 10

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

LBL-014. Rev

Patient Information MIS LLIF. Lateral Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

ACP1 CERVICAL PLATE SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE II.

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY - REDUCTION SCREWS. Surgical Technique. Hip Knee Spine Navigation

Corporate Medical Policy

Alamo T Transforaminal Lumbar Interbody System Surgical Technique

TREAT SPINAL METASTASES WITH REPRODUCIBLE PRECISION

Surgical Technique. Apache Posterior Lumbar Interbody Fusion Apache Transforaminal Lumbar Interbody Fusion

ProDisc-L Total Disc Replacement. Hospital Billing Guide.

T-PAL Spacer System. Transforaminal posterior atraumatic lumbar spacer system.

chronos STRIP Bone Void Filler

EXCELLA ll. Spinal System

2018 NuVasive Reimbursement Guide. Assisting physicians and facilities in accurate billing for NuVasive implants and instrumentation systems.

GIZA Surgical Technique

CODING SHEETS CHRONIC INTRACTABLE PAIN MANAGEMENT. Effective January 1, 2009 CODMAN 3000 NEUROMODULATION AND ONCOLOGY REIMBURSEMENT HOTLINE

Single-Thread Screw Available in 25-45mm lengths (5mm Increments) Dual-Thread Screw Available in 30-45mm lengths (5mm Increments)

Patient Information MIS TLIF. Transforaminal Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

Patient Information MIS TLIF. Transforaminal Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

Dymaxeon Spine System. Simple, Streamlined, Smart. Surgical Procedure

100 Interpace Parkway Parsippany, NJ

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

Am I eligible for the TOPS study? Possibly, if you suffer from one or more of the following conditions:

AVS ARIA TM Product Overview

NewBridge. Laminoplasty Fixation INTERNATIONAL EDITION

YOUR SUDDEN BACK PAIN MAY BE A FRACTURE

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

X-spine Surgical Technique

CSLP Quick Lock Screws. Preassembled expansionhead screw and locking screw for use with Cervical Spine Locking Plates (CSLP).

PARADIGM SPINE. Minimally Invasive Lumbar Fusion. Interlaminar Stabilization

T-PLIF Spacer. An allograft spacer for transforaminal posterior lumbar interbody fusion.

Customized Cranial and Craniofacial Implants. Instructions For Use. 7000revD_Instructions_For_Use. Page 1 of 8

POSTERIOR CERVICAL FUSION

3 Operative Technique U.S. EDITION

Transcription:

HOSPITAL OVERVIEW AND TECHNICAL ASSESSMENT Magnifuse II Demineralized Bone Graft Magnifuse II DBM is assembled at the time of use by the clinician. The clinician is able to combine the provided demineralized allograft with the recovered local autograft and then pack into a unique self-contained resorbable mesh using the disposable funnel and plunger. The surgeon can then place a fully contained construct in bone voids. Utilizes proprietary demineralized fiber technology PGA mesh bag provides a self-contained delivery mechanism PGA mesh bag helps prevent graft migration Disposable instruments facilitate the assembly process Radiopaque for assessment of graft location Conforms to patient anatomy TECHNOLOGY OVERVIEW Magnifuse II DBM is a human based allograft product. It contains human allograft bone that has been processed removing the mineral component leaving only the organic portion of bone. Bone void fillers (BVF) containing demineralized bone matrixes (DBM) have been shown to have osteoinductive potential when tested in an athymic rat assay. 1,2 Magnifuse II DBM is unique in that it is assembled with autograft tissue in a 1:1 matrix using a disposable plastic funnel and plunger and placed inside the resorbable mesh bags provided. Magnifuse II DBM does not use a carrier, providing a large volume of allograft per cc. The mesh bag is comprised of Polyglycolic Acid (PGA), commonly used in absorbable sutures. 1. Edwards JT, Diegmann MH, Scarborough NL. Osteoinduction of human demineralized bone: characterization in a rat model. Clin Orthop Relat Res. (357):219-28, 1998. 2. Animal studies are not always indicative of human clinical outcomes

TECHNOLOGY APPLICATION Magnifuse II DBM is intended for use as a bone graft substitute in bony voids or gaps of the skeletal system (i.e., the posterolateral spine and pelvis) not intrinsic to the stability of the bony structure. The voids or gaps may be surgically created defects or defects created by traumatic injury to the bone. Magnifuse II DBM is resorbed/remodeled and replaced by host bone during the healing process. Graft Preparation instructions 1. Open the outer packaging and transfer the inner packaging to the sterile field. 2. Using a syringe, inject sterile water, sterile saline, or blood into the pouch containing allograft material. Knead the allograft packaging to ensure complete hydration. Use the 5cc for the medium size and 10cc or the large size. 3. Open the allograft package and transfer the contents to a sterile bowl. Mix with morselized autograft to obtain a 1:1 ratio with the homogeneous allograft/ autograft mixture. te: Autograft size should be less than 2mm in diameter to help prevent clogging when inserting nto funnel/mesh. 4. Remove the funnel and mesh from the inner packaging. 5. Place the PGA mesh pouch on the funnel barrel until it is completely engaged. 6. Transfer half of the allograft/autograft mixture to the funnel and advance it into the barrel. 7. Insert the plunger and compress the allograft/ autograft mixture within the barrel. a. Verify the desired length of the bone graft. 8. Depress the plunger into the barrel and express the graft mass into the PGA mesh pouch. Disengage the mesh pouch from the barrel of the funnel. 9. Once the pouch is disengaged from the barrel, tighten the closure tie to prevent the graft material from loosening. 10. Cut the remaining mesh pouch with sterile surgical scissors. 11. Repeat steps 5 through 10 for a second graft. Please see surgical technique for an illustrated version of these instructions. Recommended Posterolateral Spine usage The Product should be placed between two well decorticated transverse process. Ensure the prepared graft site is in direct contact with the graft material. The Magnifuse II DBM can be packed and shaped to contour to the surgical site. The product can be secured to the graft site, if necessary, via sutures, staples, or wires. Alternative Treatment Options nsurgical treatment. nsurgical, conservative treatments, including spinal injections and physical therapy, are commonly used and are generally recommended or required before spinal fusion. Surgical decompression without fusion. Decompression of neural structures in the absence of fusion has demonstrated quality outcomes for certain indications, often related to pathologies in which there is no existing or iatrogenic deformity or instability of the spine. Spinal fusion without instrumentation. Fusion of vertebrae was originally attempted without the use of stabilizing implants. Uninstrumented lumbar spinal fusion procedures are rare due to risk of pseudoarthrosis, or failure to fuse. TECHNOLOGY PREPARATION Education Medtronic offers hospital staff a number of training opportunities on safe use of our products, including training on, where applicable, technologies, pathologies, and processes. Surgeon education and training events featuring Magnifuse II DBM are offered throughout the year at various locations. Please contact your local Medtronic sales representative for more information. Surgeons and hospital staff are also provided with other technology materials for review. Below is a list of a few of those educational items. Magnifuse II Surgical Technique using as a bone void filler PMD012924-1.0 LITMAGNBR14 Magnifuse DBM: Evaluation of bone formation potential in a sheep femoral defect white paper PMD006124 LITMGNSSWP11 Degradation and Removal of the graft delivery bag component of Magnifuse Bone Graft PMD009000 LITMAGWP13 2

TECHNOLOGY PREPARATION continued Sterilization Magnifuse II DBM products have been aseptically processed and tested for sterility according to the procedures in the current U.S. Pharmacopeia USP standard, as indicated by the package label. Pretreatment with low-dose gamma irradiation Medtronic may use low dose gamma irradiation as an adjunct to aseptic processing to reduce bioburden prior to the demineralization process. Magnifuse II DBM package labels containing pretreated with Gamma Irradiation indicate that low dose (1.0 1.8 megarads) gamma irradiation was used as a means of reducing the bioburden on the donor tissue. * Do not subject this allograft to additional disinfection or sterilization procedures. Please see the package insert for the most current sterilization information. CODING AND PAYMENT Inpatient ICD-10-PCS The insertion of demineralized bone allograft is included in the 6th character device value of a spinal fusion procedure code and not reported separately. Procedures outside of spinal fusion may require the use of an ICD-10-PCS code for the application of allograft bone. Medicare Severity-Diagnosis Related Groups (MS-DRG) Individual patient diagnosis(es) and the reporting of any surgical procedures performed will determine the appropriate MS-DRG. Spinal fusion procedures typically group to the following MS-DRGs. The use of this product may not affect MS-DRG assignment. 28 Spinal procedures w mcc 29 Spinal procedures w cc or spinal neurostimulators 30 Spinal procedures w/o cc/mcc 453 Combined anterior/posterior spinal fusion w mcc 454 Combined anterior/posterior spinal fusion w cc 455 Combined anterior/posterior spinal fusion w/o cc/mcc 456 Spinal fus exc cerv w spinal curv/malig/infec or extensive fusion w mcc 457 Spinal fus exc cerv w spinal curv/malig/infec or extensive fusion w cc 458 Spinal fus exc cerv w spinal curv/malig/infec or extensive fusion w/o cc/mcc 3 459 Spinal fusion except cervical w mcc 460 Spinal fusion except cervical w/o mcc 471 Cervical spinal fusion w mcc 472 Cervical spinal fusion w cc 473 Cervical spinal fusion w/o cc/mcc Under the MS-DRG system, cases may be assigned to a number of other MS-DRGs, based on individual patient diagnosis and presence or absence of additional surgical procedures performed. * MCC Major Complication and/or Comorbidity. CC Complication and/or Comorbidity. Outpatient CPT Code When using this product in a spinal application, report code +20930 (allograft, morselized, or placement of osteopromotive material, for spine surgery only). For non-spine related applications, the insertion of allograft may be included in the primary procedure code and not separately reported. Use the code most appropriate for the surgical procedure being performed. HCPCS Code There is not a Healthcare Common Procedure Coding System (HCPCS) Level II code assigned to this item. Payer Advocacy Refer to payer policies and guidelines for specific coverage criteria. Additional payment for implants may be allowed if negotiated as part of the contract with the commercial payer. Coding And Reimbursement Assistance Spineline Spine Coding and Reimbursement Support Provides coding, billing, and reimbursement assistance for spinal procedures performed using Medtronic products. Phone: 877-690-5353 Email: (Physicians) spinalcodingmd@medtronic.com (Hospital) spinalcodinghospital@medtronic.com Internet: www.medtronicsofamordanek.com/spineline The materials and information cited here are for informational purposes only and are provided to assist in obtaining coverage and reimbursement for health care services. However, there can be no guarantee or assurances that it will not become outdated, without the notice of Medtronic, Inc., or that government or other payers may differ with the guidance contained herein. The responsibility for coding correctly lies with the health care provider ultimately, and we urge you to consult with your coding advisors and payers to resolve any billing questions that you may have. All products should be used according to their labeling.

SUMMARY OF INDICATIONS, CONTRAINDICATIONS, AND WARNINGS Indications Magnifuse II DBM is intended for use as a bone graft substitute in bony voids or gaps of the skeletal system (i.e., posterolateral spine and pelvis) not intrinsic to the stability of the bony structure. The voids or gaps may be surgically created defects or defects created by traumatic injury to the bone. Magnifuse II DBM may be used in a manner comparable to autogenous bone or allograft bone. Magnifuse II DBM may be mixed with blood, sterile water or sterile saline in order to adjust the consistency and handling characteristics of the bone graft material. Magnifuse II DBM is resorbed/remodeled and replaced by host bone during the healing process. Contraindications The following are contraindications for the use of Magnifuse II DBM The presence of infection at the transplantation site. Treatment of spinal insufficiency fractures Caution This product may contain trace amounts of antibiotics (gentamicin), surfactant, and other solutions used in processing the bone tissue as well as the PGA mesh. Caution should be exercised if the patient is allergic to these antibiotics or chemicals. Precautions Extensive donor blood serum testing, medical and social history screening procedures, and tissue microbiological testing have been used in the qualification of all tissue donors. Despite the viral inactivation and extensive tissue donor selection and qualifications process used in providing this tissue graft, transmission of an infectious disease through the use of this tissue graft is still possible. Bacterial infection at the graft site may also occur. Any adverse outcomes potentially attributable to Magnifuse II DBM must be reported promptly to Medtronic. Adequate fixation should be used to stabilize the implant site during bone formation and healing in bony voids or gaps of the skeletal system. Indications The CD Horizon Spinal System with or without Sextant instrumentation is intended for posterior, non-cervical fixation as an adjunct to fusion for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, curvatures (i.e., scoliosis, kyphosis, or lordosis), tumor, pseudarthrosis, and/ or failed previous fusion. Except for hooks, when used as an anterolateral thoracic/lumbar system, the CD Horizon Spinal System may also be used for the same indications as an adjunct to fusion. With the exception of degenerative disc disease, the CD Horizon Legacy 3.5mm rods and the CD Horizon Spinal System PEEK rods and associated components may be used for the aforementioned indications in skeletally mature patients as an adjunct to fusion. The 3.5mm rods may be used for the specific pediatric indications noted below. When used for posterior non-cervical pedicle screw fixation in pediatric patients, the CD Horizon Spinal System implants are indicated as an adjunct to fusion to treat progressive spinal deformities (i.e., scoliosis, kyphosis, or lordosis) including idiopathic scoliosis, neuromuscular scoliosis, and congenital scoliosis. Additionally, the CD Horizon Spinal System is intended to treat pediatric patients diagnosed with the following conditions: spondylolisthesis/ spondylolysis, fracture caused by tumor and/or trauma, pseudarthrosis, and/or failed previous fusion. These devices are to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach. The CD Horizon Spire Plate is a posterior, singlelevel, non-pedicle supplemental fixation device intended for use in the non-cervical spine (T1-S1) as an adjunct to fusion in skeletally mature patients. It is intended for plate fixation/attachment to spinous processes for the purpose of achieving supplemental fixation in the following conditions: degenerative disc disease (as previously defined), spondylolisthesis, trauma, and/or tumor. In order to achieve additional levels of fixation, the CD Horizon Spinal System rods may be connected to the Vertex Reconstruction System with the Vertex rod connector. Refer to the Vertex Reconstruction System Package Insert for a list of the Vertex indications of use.

Additional Information Is the product implantable? How was the product cleared? Cleared via 510(k) path K122513(Copies available upon request or from the FDA web site http://www. accessdata.fda.gov/cdrh_docs/pdf13/k122513.pdf) Is your facility licensed and registered to distribute human tissue products? Yes (Copies of licenses and registrations available upon request) Does the product require additional instruments? te: this product should always be used in conjunction with supplemental fixation. Those systems will have their own instrumentation. Does the product need to be checked by Biomed? Does the product contain Mercury? Does the product contain Latex? Does the product contain Carbon-based tissue? Yes Human Is this product MRI safe? What temperature should the product be stored? Store this product at 15 30 C (59 86 F). Do not Freeze Is the tissue tracked? The product is tracked in accordance with Federal (USA) regulations under 21 CFR1271 established requirements for tracking human tissue products. Contact customer service or your sale representative for the most up-to-date version of the package insert or visit http://manuals.medtronic.com/manuals/main/region Product Ordering Information Part Number Description 7509505 Magnifuse II Regular 2.5cm 5cm 7509510 Magnifuse II Large 2.5cm 10cm Medtronic Spinal and Biologics Business Worldwide Headquarters 2600 Sofamor Danek Drive Memphis, TN 38132 Medtronic Sofamor Danek USA, Inc. 1800 Pyramid Place Memphis, TN 38132 (901) 396-3133 (800) 876-3133 Customer Service: (800) 933-2635 Please see the package insert for the complete list of indications, warnings, precautions, and other important medical information. Consult instructions for use at this website www.medtronic.com/manuals. te: Manuals can be viewed using a current version of any major internet browser. For best results, use Adobe Acrobat Reader with the browser. medtronic.com 2017 Medtronic. All Rights Reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. All other brands are trademarks of a Medtronic company. UC201804834 EN PMD012927-2.0