FINITE ELEMENT ANALYSIS OF KNEE IMPLANT AND PROTOTYPE FABRICATION USING RPT PROCESS

Similar documents
[ICESTM-2018] ISSN Impact Factor

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Biomechanical Analysis of Different Knee Prosthesis Biomaterials Using Fem

Biomechanics of. Knee Replacement. Mujda Hakime, Paul Malcolm

International Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint

(c) B. Ravi, IIT Bombay 1

A Brief on Normal Human Gait Cycle and the Development of Artificial Prosthesis of Human Knee Along With Its Jigs and Fixtures

Total Knee Replacement

ADDITIVE MANUFACTURING AND ANALYSIS OF TIBIAL INSERT IN TOTAL KNEE REPLACEMENT IMPLANT

Knee Replacement Implants

Identify the role of the skeletal system particularly in relation to maintaining an upright stance and protecting vital organs.

YOU MAY NEED A KNEE REPLACEMENT

LING AND ANALYSIS PROSTHESIS WITH MODULAR STEM

Partial Knee Replacement

Biomechanical Investigations on the Total Knee Arthroplasty (TKA)

Full Function, Faster Medial-Pivot

Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty

PARTIAL KNEE REPLACEMENT

Modeling And Biomechanical Analysis Of Human Knee Joint

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

ISSN: [NCIME: October 2016] Impact Factor: 4.116

The Development and Analysis of an FEA Simulation on an Artificial Knee

KNEE ARTHROSCOPY. How the Normal Knee Works

Modeling of human knee joint and finite element analysis of landing impact motion

I want that next-generation knee

ANTERIOR CRUCIATE LIGAMENT INJURY

Unicompartmental Knee Resurfacing

Modeling and Static Analysis of Human Knee Joint by using Different Implant Materials

Département de génie mécanique, Ecole nationale polytechnique d Oran BP 1523 M naour, Oran Algeria.

Modal Analysis of Hip Joint Implant Used In the Human Body

A Patient s Guide to Knee Anatomy

High Tibial Osteotomy

Anatomy. Anatomy deals with the structure of the human body, and includes a precise language on body positions and relationships between body parts.

A Patient s Guide to Knee Anatomy. Stephanie E. Siegrist, MD, LLC

Anterior Cruciate Ligament (ACL) Injuries

Integra Cadence Total Ankle System PATIENT INFORMATION

Effect of the femoral stem size on femur bone quality towards THR

CHAPTER 8: THE BIOMECHANICS OF THE HUMAN LOWER EXTREMITY

Finite element analysis of prosthetic knee joint using ANSYS

Pre-Op Planning for your knee replacement surgery

Cranial Cruciate Ligament Disease

Case study for quality control & quality assurance in metal additive manufacturing: A dental bridge

It s your knee. Help keep it that way PERSONALIZED TOTAL KNEE IMPLANTS

Arthroscopy. Turnberg Building Orthopaedics

ACL RECONSTRUCTION HAMSTRING METHOD. Presents ACL RECONSTRUCTION HAMSTRING METHOD. Multimedia Health Education

A PATIENT S GUIDE TO REHABILITATION POST KNEE REPLACEMENT SURGERY

6 th International Conference on Trends in Agricultural Engineering 7-9 September 2016, Prague, Czech Republic

Total Knee Replacement

Summer Workshop of Applied Mechanics. Theoretical Analysis of Total Hip Joint Replacement of Sandwich design by FEM

Anterior Cruciate Ligament (ACL)

Product Information & Procedure Wall Chart

The Knee. Prof. Oluwadiya Kehinde

Why do I perform PFP? Fernando Fonseca, MD PhD Head of Department Orthopaedics

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

Your Practice Online

YOUR TOTAL KNEE REPLACEMENT

INTRODUCING THE VERASENSE KNEE SYSTEM

FINITE ELEMENT MODELING OF HUMAN KNEE JOINT - MENISCUS UNDER COMPRESSIVE LOAD

Knee Replacement Complications

Life Science Journal 2014;11(12) Surface Modification and Software Design of Customized Knee Joint

Comparative Study of Fixation Devices for Intertrochanteric Fractures

Effect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant

Win Your Life Back Through Knee Replacement

Development and Analysis of Composite Material for In-Situ Hip Prosthesis

Cruciate ligament injury

Shoulder Joint Replacement

Knee Anatomy Introduction Welcome to BodyZone Physiotherapy's patient resource about Knee problems.

Common Knee Injuries

36 1 The Skeletal System Slide 1 of 40

Anatomy and Physiology 1 Chapter 9 self quiz Pro, Dima Darwish,MD.

Examination of the Knee

A Patient s Guide to Partial Knee Resurfacing

Topology optimisation of hip prosthesis to reduce stress shielding

Integra. Salto Talaris Total Ankle Prosthesis PATIENT INFORMATION

A Guide to Common Ankle Injuries

TOTAL KNEE ARTHROPLASTY (TKA)

Advanced FE Modeling of Absorbable PLLA Screws

Freedom and safety in treatment

Revolution. Unicompartmental Knee System

Arthritis. What is arthritis? Who is affected? What treatment options are available?

New methods for the simulation with finite element of the human elbow

and K n e e J o i n t Is the most complicated joint in the body!!!!

Outline. Skeletal System. Functions of Bone. Bio 105: Skeletal System 3/17/2016. The material from this lecture packet will be on the lecture exam

A NEW CONCEPT IN FUNCTIONAL ORTHOSES

Other Culprits in Knee Dysfunction

Recognizing common injuries to the lower extremity

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

UNIT 2 - CHAPTER 8: JOINTS OF THE SKELETAL SYSTEM LEARNING OUTCOMES:

ANALYSYS & OPTIMIZATION OF HYDRAULIC EXCAVATOR BUCKET TEETH USING FEM

Effects of Variation in Surgical Technique on Range of Motion in Total Knee Replacement

BIOMECHANICAL EVALUATION OF DEGREE OF FREEDOM OF MOVEMENTS OF AN NOVEL HIGH FLEXION KNEE FOR ITS SUITABILITY IN EASTERN LIFESTYLES

Anterior Cruciate Ligament Injuries

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement

The Knee. Tibio-Femoral

Articulations. Articulation. Joint between bones. Does not mean movement! Some joints are immovable; sutures.

Transcription:

International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 12, December 2017, pp. 197 205, Article ID: IJMET_08_12_020 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=12 ISSN Print: 0976-6340 and ISSN Online: 0976-6359 IAEME Publication Scopus Indexed FINITE ELEMENT ANALYSIS OF KNEE IMPLANT AND PROTOTYPE FABRICATION USING RPT PROCESS B.Rajesh, L.Radhakrishna and K.Venkata Reddy Assistant Professor, Department of Mechanical Engineering, S R Engineering College, Warangal, Telangana, India ABSTRACT The aim of this research work is to do finite element analysis of patient specific knee implant and compare the stress analysis results with commercially available knee implant and Fabrication of prototypes of Patient Specific knee implant and commercially available knee implant are done using FDM additive manufacturing process. In this research, it is proposed to develop a three-dimensional model of knee implant from.stl file of knee joint using software s like meshlab, NetFabb and CATIA software s. The data is obtained from Sunshine Hospital, Secunderabad. Based on the dimensions of knee joint, it is proposed to Design a Knee implant in Catia software. Once the 3D CAD model is designed in Catia software, it is meshed in ANSYS and finite element analysis is performed for varying loads (500N-5000N). The obtained results are compared with the commercially available knee implant. According to walking condition the patient specific knee implant is analyzed for different flexion angles (15, 45, 60 degrees). Fabrication of prototypes of patient Specific knee implant and commercial available knee implants are done using FDM additive manufacturing process. Keywords: finite element, knee implant, RPT Cite this Article: B.Rajesh, L.Radhakrishna and K.Venkata Reddy, Finite Element Analysis of Knee Implant and Prototype Fabrication using Rpt Process, International Journal of Mechanical Engineering and Technology 8(12), 2017, pp. 197 205. http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=12 1. INTRODUCTION 1.1 KNEE JOINT The knee is one of the largest and most complex joint in the human body. The knee joins the thigh bone (femur) to the shin bone (tibia). The smaller bone runs alongside the tibia (fibula) and the knee-cap (patella) and the other bones that make the knee joint. Tendons connect the knee bones to the leg muscles that move the knee joint. Ligaments join the knee bones and provide stability to the knee joint: http://www.iaeme.com/ijmet/index.asp 197 editor@iaeme.com

Finite Element Analysis of Knee Implant and Prototype Fabrication using Rpt Process The anterior cruciate ligament prevents the femur from sliding backward on the tibia (or the tibia sliding forward on the femur). The posterior cruciate ligament prevents the femur from sliding forward on the tibia (or the tibia from sliding backward on the femur). The medial and lateral collateral ligaments prevent the femur from sliding side to side. Two C-shaped pieces of cartilage called the medial and lateral menisci act as shock absorbers between the femur and tibia. Numerous bursae, or fluid-filled sacs, help the knee move smoothly. Figure 1 Knee Implant Reasons for damage of Knee Implant: the main reasons for the damage of the knee joint are as follows: Wear and loosening: Friction caused by joint surfaces rubbing against each other wears away the surface of the implant causing bone loss and loosening of the implants. Infection: Large metal and plastic implants can serve as a surface onto which bacteria can latch. Fracture: Fractures around the knee implant that disrupt its stability may require revision surgery. Instability: A sensation of the knee "giving away" may mean that the soft-tissue surrounding the knee is too weak to support standing and walking. Improperly placed implants may also cause instability. Stiffness: Loss of range of motion which causes pain and a functional deficit.[12] Implant material Generally Implants are manufactured with materials like metals, and ceramics. The metals used like Titanium, cobalt, chromium and stainless steel as shown in Table 1 Material Table 1 Common metals and properties used for implants Density (g/cc) Compresive strength (Mpa) Elastic modulas (Gpa) Toughness (Mpa) Titanium 4.4-4.5 590-1117 55-117 55-115 Stainless steel 7.9-8.1 170-310 189-205 50-200 Co-cr-mo alloy 8.3-9.2 450-1896 200-253 100 http://www.iaeme.com/ijmet/index.asp 198 editor@iaeme.com

B.Rajesh, L.Radhakrishna and K.Venkata Reddy 2. PROBLEM STATEMENT Knee arthritis has been a serious problem facing around 70 million patients worldwide. Total knee replacement has become an acceptable method of treating severe arthritis of the knee. The operative procedure must be performed with precise skill and accuracy. Great care and importance is given while selecting a proper and suitable biocompatible material for fabricating an implant. To make a bio-compatible implant it is important to know where it is located in the body. For the structural mechanics of human body involving bones, tissues and organs, it is almost impossible to conduct mechanical experiments. The finite element model to simulate such mechanical experiments has thus become an effective tool. In this research, analysis of knee Implant is done which is designed according to the dimensions obtained from the STL file of knee joint and compared with the commercially available knee implant for three different bio-materials based on patient body weight acting on human body under different walking conditions. The patient specific knee implant is also analyzed for different flexion angles. Fabrication of designed and commercial knee implants is done using Fused Deposition Modeling RPT Process. 3. RESULTS AND DISCUSSIONS This chapter presents the results obtained after adopting the research methodolgy discussed in earlier chapter. The finite element analysis of the patient specific Knee implant is done under static condition for different Flexion angles viz 0,15,45,60 degrees. The zero degres of Flexion angle represents the normal standing condition of the human being. Analysis of patient specific Knee implant at zero degrees of three different biocompatible materials Load (N) Table 2 Comparison of Von-mises stress for different bio-compatible materials Von-mises stress (mpa) Ti-6Al-4V Co-Cr-Mo SS 316L 500 2.65 3.08 3.07 1000 5.30 6.16 6.14 1500 7.95 9.24 9.21 2000 10.60 12.32 12.29 2500 13.25 15.41 15.36 3000 15.90 18.49 18.43 3500 18.55 21.57 21.51 4000 21.20 24.65 24.58 4500 23.85 27.74 27.65 5000 26.50 30.82 30.73 Load (N) Table 3 Comparison of Total deformation for different bio-compatible materials Total deformation (mm) Ti-6Al-4V Co-Cr-Mo SS 316L 500 0.0027 0.0020 0.0021 1000 0.0055 0.0040 0.0042 1500 0.0083 0.0060 0.0064 2000 0.0111 0.0080 0.0085 http://www.iaeme.com/ijmet/index.asp 199 editor@iaeme.com

Finite Element Analysis of Knee Implant and Prototype Fabrication using Rpt Process 2500 0.0139 0.010 0.0106 3000 0.0165 0.012 0.0128 3500 0.0194 0.014 0.0149 4000 0.0222 0.016 0.0170 4500 0.0250 0.018 0.0192 Analysis of patient specific Knee implant of various flexion angles The 3D cad model of Knee implant assembly is rotated to 15,45,60 degrees in catia software, according to walking condition and are imported in ANSYS IGES format and analysis was carried out for three different materials with combination of ultra-high-molecular-weightpolyethylene (UHMWPE). The results were found out in the form of von-mises stress, total deformation and contact pressure at each degree of flexion Table 4 Comparison of Von-mises stress and Total deformation at Titanium alloy and different flexion angles Flexion angles (deg) Von-mises stress (Mpa) Total deformation (mm) 500N 2500N 500N 2500N 15 8.97 44.876 0.005 0.02 45 8.84 44.23 0.015 0.07 60 7.13 35.696 0.03 0.15 Figure 2 Graph plotted between Von-mises stress and Total deformation at Ti-4Al-6V Table 5 Comparison of Von-mises stress and Total deformation at SS 316 alloy and different flexion angles Flexion angles (deg) Von-mises stress(mpa) Total deformation (mm) 500N 2500N 500N 2500N 15 9.18 45.94 0.004 0.02 45 9.20 46.02 0.014 0.07 60 7.64 38.2 0.02 0.14 http://www.iaeme.com/ijmet/index.asp 200 editor@iaeme.com

B.Rajesh, L.Radhakrishna and K.Venkata Reddy Table 6 Comparison of Von-mises stress and Total deformation at Co-Cr-Mo alloy and different flexion angles Flexion angles (deg) Von-mises stress (Mpa) Total deformation (mm) 500N 2500N 500N 2500N 15 9.21 46.05 0.004 0.02 45 9.18 45.9 0.014 0.07 60 7.72 38.64 0.02 0.13 Figure 3 graph plotted between Von-mises stress and Total deformation at SS 316L Figure 4 graph plotted between Von-mises stress and Total deformation at Co-Cr-Mo Comparison of Analysis Results for patient specific and Commercial Knee Implants The von-mises stress and total deformation values obtained for the designed and commercially available Knee implants for three different bio-compatible materials are compared as shown in tables 6.8, 6.9,6.10 and correspondingly graphs are drawn as shown in figures. 6.4.1. For Titanium alloy The von-mises stress and total deformation values obtained for the patient specific and commercially available Knee implants for three different bio-compatible materials are compared as shown in tables 6.8 and graphs is plotted as shown in fig 6.20 and 6.21 http://www.iaeme.com/ijmet/index.asp 201 editor@iaeme.com

Finite Element Analysis of Knee Implant and Prototype Fabrication using Rpt Process Table 7 Comparison of Equivalent Stress and Total Deformation for patient specific and Commercial knee Implants made of Titanium alloy. LoadApplied (N) Equivalent Stress (MPa) Total Deformation (mm) Patient specific Commercial Patient Specific Commercial 500 2.65 3.15 0.0027 0.0066 1000 5.30 6.31 0.0055 0.013 1500 7.95 9.46 0.0083 0.019 2000 10.60 12.62 0.0111 0.026 2500 13.25 15.77 0.0139 0.033 3000 15.90 18.93 0.0165 0.039 3500 18.55 22.09 0.0194 0.046 4000 21.20 25.24 0.0222 0.053 4500 23.85 28.40 0.0250 0.059 5000 26.50 31.55 0.0278 0.066 Figure 5 Comparison of Equivalent Stress for Designed(patient specific) and Commercial Knee implants made of Titanium alloy. Figure 6 Comparison of Total Deformation for Designed (patient specific) and Commercial Knee Implants made of Titanium alloy. http://www.iaeme.com/ijmet/index.asp 202 editor@iaeme.com

B.Rajesh, L.Radhakrishna and K.Venkata Reddy 6.4.2. For SS 316L alloy hevon-mises stress and total deformation values obtained for the patient specific and commercially available Knee implants for three different bio-compatible materials are compared as shown in tables 6.10 and graphs is plotted as shown in fig 6.24 and 6.25. Table 6.10 Comparison of Equivalent Stress and Total Deformation for patient specific and Commercial knee Implants made of SS 316L alloy. Load Applied (N) Equivalent Stress (MPa) Total Deformation (mm) patient specific Commercial patient specific Commercial 500 3.07 4.20 0.0021 0.005 1000 6.14 8.41 0.0042 0.01 1500 9.21 12.62 0.0064 0.016 2000 12.29 16.83 0.0085 0.021 2500 15.36 21.04 0.01 0.026 3000 18.43 25.25 0.012 0.032 3500 21.51 29.46 0.014 0.037 4000 24.58 33.66 0.017 0.043 4500 27.65 37.87 0.019 0.048 5000 30.73 42.08 0.02 0.053 Figure 7 Comparison of Von-Mises stress for Designed(patient specific) and Commercial Knee implants made of SS 316L alloy. http://www.iaeme.com/ijmet/index.asp 203 editor@iaeme.com

Finite Element Analysis of Knee Implant and Prototype Fabrication using Rpt Process Figure 8 Comparison of Total Deformation for Designed (patient specific) and Commercial Knee implants made of SS 316L alloy. 7. CONCLUSIONS The aim of this research work is to do finite element analysis of patient specific knee implant and compare the stress analysis results with results of commercially available knee implant. Manufacturing of patient specfic knee implant and Commercial Knee implants Prototypes are done using FDM additive manufacturing process. Knee implant is designed by taking the dimensions from.stl file in CATIA software and analysis is performed in ansys software to determine the von-mises stress under various walking conditions. The values obtained are tabulated accordingly as mentioned in research and methodology. Following are the conclusions made from the Research Methodology adopted. For Proposed patient specific Knee implant, the von-misses stresses and deformation values obtained for different bio-materials under walking condition are as follows: For Ti-4A-l4V alloy, the maximum von-misses stress and total deformation values obtained are 26.50 MPa and 0.0278 mm respectively. For SS-316L material, the maximum von-misses stress and total deformation values obtained are 30.73 MPa and 0.02 mm respectively. For Commercially available Knee implant, the von-misses stresses and deformation values obtained for different bio-materials under walking condition are as follows: For Ti-4Al46V alloy, the maximum von-misses stress and total deformation values obtained are 31.55MPa and 0.066 mm respectively. For SS-316L material, the maximum von-misses stress and total deformation values obtained are 42.08 MPa and 0.053 mm respectively. For Cr-Co-Mo alloy, the maximum von-misses stress and total deformation values obtained are 43.28MPa and 0.041mm respectively. From the first study (FEM analysis when knee is in normal position) it is clear that even under extreme loading conditions, the prosthesis is safe (values obtained are below allowable stress) and gives good results for all selected biomaterials - Ti-6Al- 4V, Co-Cr, SS-316L, UHMWPE http://www.iaeme.com/ijmet/index.asp 204 editor@iaeme.com

B.Rajesh, L.Radhakrishna and K.Venkata Reddy At applied 5000 N load, least and maximum deformation values found for Cobalt alloy is 0.020 mm and for Titanium alloy is 0.027 respectively, similarly least and maximum equivalent stresses develop were Titanium alloy is 26.50 MPa, whose allowable stress is 880 MPa and Cobalt alloy is 30.82 MPa whose allowable stress is 612 MPa respectively. From the finite element analysis results obtained by rotating the designed knee implant at different flexion angles (15, 45, 60 degrees), it is observed that even if maximum load is applied i.e. 2500N the von misses stress values are obtained are 44.876 MPa for Titanium Alloy and 45.94 MPa for SS 316L Alloy and 46.05 MPa for Co-Cr-Mo alloy which are less compared to maximum allowable stress of three bio-compatible materials. For the two designs which are analysed in the thesis work, von-mises stress values obtained indicate that, titanium alloy material is best sutible compared to Co-Cr-Mo alloy and SS 316L. From this study it is found that stress induced for all selected biomaterials Ti-6Al- 4v,and Co-Cr-Mo alloy and SS 316 L are with in allowable limit for maximum force and least deformation among all cases was found to be for Cobalt alloy. Fabrication of patient specific and Commercial Knee implants are done using fused deposition Modeling machine. The printing time and material consumed for patient specific and Commercial Knee implants are 25 min, 9.24 gms and 50 min, 18 gms. REFERENCE [1] A. Sreenivasa Rao and K Venkata Rao. A Study on Machining Characteristics in Milling of Ti-6Al-4V using Experimental and Finite Element Analysis. International Journal of Civil Engineering and Technology, 8(7), 2017, pp. 457 469. [2] R. Deendayal, Behaviour of a Single Pile Located on Sloping Ground of a Soil Under Cyclic Loading: A Finite Element Analysis. International Journal of Civil Engineering and Technology, 8(10), 2017, pp. 925 932 [3] S. P. Chaphalkar and V. S. Byakod, Design and Analysis of Bridge with Two Ends Fixed on Vertical Wall Using Finite Element Analysis, International Journal of Civil Engineering and Technology, 7(2), 2016, pp. 34-44. [4] S. Jayavelu, C. Rajkumar, R. Rameshkumar and D. Surryaprakash, Design and Analysis of Vibration and Harshness Control For Automotive Structures Using Finite Element Analysis, International Journal of Civil Engineering and Technology, 8(10), 2017, pp. 1364 1370. http://www.iaeme.com/ijmet/index.asp 205 editor@iaeme.com