H.Pylori IgG

Similar documents
H.Pylori IgG Cat # 1503Z

H. pylori IgM. Cat # H. pylori IgM ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

H.Pylori IgM Cat # 1504Z

H.pylori IgA Cat #

See external label 2 C-8 C Σ=96 tests Cat # 1505Z. MICROWELL ELISA H.Pylori IgA Cat # 1505Z

H. pylori IgM CLIA kit

H. pylori Antigen ELISA Kit

Herpes Simplex Virus 2 IgG HSV 2 IgG

Herpes Simplex Virus 2 IgM HSV 2 IgM

Toxoplasma gondii IgM (Toxo IgM)

See external label 96 tests HSV 2 IgA. Cat #

DIAGNOSTIC AUTOMATION, INC.

See external label 2 C-8 C 96 tests Chemiluminescence. CMV IgM. Cat # Diluted samples, controls & calibrator 100 µl 30 minutes

See external label 2 C-8 C 96 tests CHEMILUMINESCENCE. CMV IgG. Cat # Step (20-25 C Room temp.) Volume

Chlamydia Trachomatis IgA

Helicobacter pylori IgA ELISA Kit

CHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) Toxoplasma IgG. Cat # (20-25 C Room temp.) Volume

Rubella virus IgG ELISA Kit

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

Human Cytomegalovirus IgM ELISA Kit

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

Toxoplasma gondii IgM ELISA Kit

Toxoplasma gondii IgM ELISA Kit

MICROWELL ELISA Measles IgM Catalog #

See external label 2 C-8 C Σ=96 tests Cat # EBV-VCA IgA. Cat # EBV -VCA IgA ELISA. ELISA: Enzyme Linked Immunosorbent Assay

EBV-EA IgG. Cat # 1415Z. EBV -EA IgG ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

Anthrax protective antigen IgG ELISA Kit

IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol

Mycoplasma pneumoniae IgG ELISA Kit

EBV-VCA IgA Cat #

HSV-1 IgM ELISA. Catalog No (96 Tests) For Research Use Only. Not for use in Diagnostic Procedures.

Treponema Pallidum Total Antibody ELISA

Measles IgM ELISA Kit

Chlamydia Trachomatis IgG ELISA Kit

Cotinine (Mouse/Rat) ELISA Kit

VZV IgG ELISA Catalog No (96 Tests)

Treponema pallidum Total ELISA Kit

Triiodothyronine (T3) ELISA

Chlamydia Trachomatis IgM ELISA Kit

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

Thyroid Stimulating Hormone (TSH) ELISA Catalog No. GWB , legacy id (96 Tests)

E. Histolytica IgG (Amebiasis)

ReQuest H. Pylori IgG

Treponema pallidum IgM ELISA Kit

T3 (Total) (Mouse/Rat) ELISA Kit

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Thyroid Peroxidase IgG ELISA

Thyroid Peroxidase IgG ELISA Kit

Insulin (Porcine/Canine) ELISA

Testosterone ELISA. Catalog No (96 Tests) For Research Use Only. Not for use in Diagnostic Procedures.

Follicle Stimulating Hormone (FSH) ELISA Catalog No (96 Tests)

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Bovine Insulin ELISA

Porcine/Canine Insulin ELISA

See external label 2 C-8 C = C-REACTIVE PROTEIN (CRP) LATEX SLIDE TEST

Influenza A IgG ELISA

Trichinella Cat #

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Cortisol (Sheep) ELISA Kit

Mouse C-peptide ELISA

Serum Amyloid A ELISA

Toxocara. Cat # Toxocara ELISA. Enzyme Linked Immunosorbent Assay. ELISA-Indirect; Antigen Coated Plate

Mouse Ultrasensitive Insulin ELISA

Mouse C-peptide ELISA

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Apolipoprotein A-1 ELISA

QUANTA Lite TM H. pylori IgA ELISA For In Vitro Diagnostic Use CLIA Complexity: High

H. pylori IgG Enzyme Immunoassay Test Kit For In Vitro Diagnostic Use Catalog No Tests

Taenia solium IgG ELISA Kit

Procine sphingomyelin ELISA Kit

Rapid-VIDITEST. Helicobacter pylori. One step Helicobacter pylori Blister test. Instruction manual

EliKine Free Thyroxine (ft4) ELISA Kit

Rat Proinsulin ELISA

Dengue IgG/IgM Dengue IgG and IgM ELISA. Enzyme Linked Immunosorbent Assay. ELISA-Indirect; Antigen Coated Plate

Instructions for Use. Tg Antibody ELISA

Human HIV (1+2) antigen&antibody ELISA Kit

AccuDiag Herpes Simplex 2 IgG. HSV 2 IgG ELISA

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

HBeAg and HBeAg Ab ELISA Kit

Adrenocorticotropic Hormone (ACTH) ELISA

ELEGANCE Chlamydia pneumoniae IgG ELISA KIT

Human Legionella ELISA Kit

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

Cryptosporidium Veterinary

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Mouse C3 (Complement Factor 3) ELISA Kit

Human Gliadin IgG ELISA Kit

SIV p27 Antigen ELISA Catalog Number:

FinTest TM IgG4 Screen 88 ELISA Kit

See external label 96 tests ULTRASENSITIVE THYROID STIMULATING HORMONE (u-tsh) TSH Ultra Sensitive

Mouse C-Peptide ELISA Kit

See external label 2 C-8 C Σ=96 tests Cat # 3122Z MICROWELL ELISA THYROID STIMULATING HORMONE (TSH) ENZYME IMMUNOASSAY TEST KIT TSH.

Human HBcAb IgM ELISA kit

Vedolizumab Drug Level ELISA

TSH Receptor Autoantibody ELISA

anti-ssa Enzyme Immunoassay

HIV-1 p24 ELISA Kit. Catalog Number KA assays Version: 06. Intended for research use only.

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Human Aldosterone ELISA Kit

Transcription:

DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external label 96 tests 1503-11 H.Pylori IgG 1503-11 Test Method Principle Detection Range Sample H.pylori IgG ELISA ELISA: Enzyme Linked Immunosorbent Assay ELISA - Indirect; Antigen Coated Plate Qualitative Positive; Negative control & Cut off 5ul Serum Specificity 97% Sensitivity 99 % Total Time Shelf Life ~ 75 min 12 Months from the manufacturing date * Laboratory results can never be the only base of a medical report. The patient history and further tests have to be taken into account DAI Code# 11 Page 1 of 6

SUMMARY OF ASSAY PROCEDURE Step (20-25 C Room temp.) Volume 1 Sample dilution 1:40 = 5 µl / 200 µl Incubation time 2 Diluted sample, calibrator & controls 100 µl 30 minutes 3 Washing buffer (3 times) 350 µl 4 Enzyme conjugate 100 µl 30 minutes 5 Washing buffer (3 times) 350 µl 6 TMB Chromogenic Substrate 100 µl 15 minutes 7 Stop solution 100 µl 8 Reading OD 450 nm NAME AND INTENDED USE DAI Helicobacter pylori IgG is intended for use in evaluating the serologic status to H. pylori infection in patients with gastrointestinal symptoms. SUMMARY AND EXPLANATION OF THE TEST Helicobacter pylori is a spiral bacterium cultured from human gastric mucosa by Marshall in 1982. Studies have indicated that the presence of H. pylori is associated with a variety of gastrointestinal diseases including gastritis, duodenal and gastric ulcer, non-ulcer dyspepsia, gastric adenocarcinoma and lymphoma. The organism is present in 95-98% of patients with duodenal ulcer and 60-90% of patients with gastric ulcers. The studies have also demonstrated that removal of the organism by antimicrobial therapy is correlated with the resolution of symptoms and cure of diseases. Patients who present with clinical symptoms relating to the gastrointestinal tract can be diagnosed for H. pylori infection by two methods: 1) invasive techniques include biopsy followed by culture or histologic examination of biopsy specimen or direct detection of urease activity. 2) non-invasive techniques include urea breath tests and serological methods. All of the testing performed on biopsy samples are subject to errors related to sampling and interference of contaminated bacteria. H. pylori IgG, testing the presence of H. pylori specific IgG antibody is the technique of choice for serologic tests because of its accuracy and simplicity. PRINCIPLE OF THE TEST Purified H. pylori antigen is coated on the surface of microwells. Diluted patient serum is added to wells, and the H. pylori IgG specific antibody, if present, binds to the antigen. All unbound materials are washed away. After adding enzyme conjugate, it binds to the antibody-antigen complex. Excess enzyme conjugate is washed off and TMB Chromogenic substrate is added. The enzyme conjugate catalytic reaction is stopped at a specific time. The intensity of the color generated is proportional to the amount of IgG specific antibody in the sample. The results are read by a microwell reader compared in a parallel manner with calibrator and controls. MATERIALS PROVIDED 1. Microwell Strips: Purified H. pylori antigen coated wells. (12 x 8 wells) 2. Sample Diluent: Blue color solution. 1 bottle (22ml) 3. Calibrator: Factor value ( f ) stated on label. Red Cap. 1 vial (150 l) DAI Code# 11 Page 2 of 6

4. Negative Control: Range stated on label. Natural Cap. 1 vial (150 l) 5. Positive Control: Range stated on label. Brown Cap. 1 vial (150 l) 6. Washing Concentrate 20x. 1 bottle (50 ml) 7. Enzyme Conjugate: Red color solution. 1 vial (12 ml) 8. TMB Chromogenic Substrate: Amber bottle. 1 vial (12 ml) 9. Stop Solution. 1 vial (12 ml) STORAGE AND STABILITY 1. Store the kit at 2-8 o C. 2. Always keep microwells tightly sealed in pouch with desiccants. We recommend you use up all wells within 4 weeks after initial opening of the pouch. 3. The reagents are stable until expiration of the kit. 4. Do not expose test reagents to heat, sun or strong light during storage or usage. WARNINGS AND PRECAUTIONS 1. Potential biohazardous materials: The calibrator and controls contain human source components which have been tested and found nonreactive for hepatitis B surface antigen as well as HIV antibody with FDA licensed reagents. However, as there is no test method that can offer complete assurance that HIV, Hepatitis B virus or other infectious agents are absent, these reagents should be handled at the Biosafety Level 2, as recommended in the Centers for Disease Control/National Institutes of Health manual, "Biosafety in Microbiological and Biomedical Laboratories." 1984 2. This test kit is designed for in vitro diagnostic use. 3. Do not pipette by mouth. Do not smoke, eat, or drink in the areas in which specimens or kit reagents are handled. 4. The components in this kit are intended for use as a integral unit. The components of different lots should not be mixed. 5. This product contains components preserved with sodium azide. Sodium azide may react with lead and copper plumbing to form explosive metal azide. On disposal, flush with a large volume of water. SPECIMEN COLLECTION AND HANDLING 1. Collect blood specimens and separate the serum. 2. Specimens may be refrigerated at 2-8 o C for up to seven days or frozen for up to six months. Avoid repetitive freezing and thawing of serum sample. PREPARATION FOR ASSAY 1. Prepare 1x washing buffer. Prepare washing buffer by adding distilled or deionized water to 20X wash concentrate to a final volume of 1 liter. 2. Bring all specimens and kit reagents to room temperature (20-25 oc) and gently mix. DAI Code# 11 Page 3 of 6

ASSAY PROCEDURE 1. Place the desired number of coated strips into the holder. 2. Prepare 1:40 dilutions by adding 5 µl of the samples, negative calibrator, positive calibrator, cut-off calibrator, and controls to 200 µl of sample diluent. Mix well. 3. Dispense 100 µl of diluted sera, calibrators, and controls into the appropriate wells. For the reagent blank, dispense 100 µl sample diluent in 1A well position. Tap the holder to remove air bubbles from the liquid and mix well. Incubate for 30 minutes at room temperature. 4. Remove liquid from all wells. Repeat washing three times with washing buffer. 5. Dispense 100 µl of enzyme conjugate to each well and incubate for 30 minutes at room temperature. 6. Remove enzyme conjugate from all wells. Repeat washing three times with washing buffer. 7. Dispense 100 µl of TMB Chromogenic Substrate to each well and incubate for 15 minutes at room temperature. 8. Add 100 µl of Stop Solution to stop reaction. Make sure there are no air bubbles in each well before reading. 9. Read O.D. at 450 nm with a microwell reader. CALCULATION OF RESULTS 1. To obtain Cut off value: Multiply the OD 450 of Calibrator by Factor ( f ) printed on label of Calibrator. 2. Calculate the IgG Index of each determination by dividing the OD values of each sample by obtained OD value of Cut off. This factor ( f ) is a variable. It is specific for a lot manufactured and printed on label of Calibrator. For example: If Factor ( f ) value on label = 0.30 Sample OD 450 Calibrator f = 0.3 Positive Control Negative Control Patient Sample 1 Patient Sample 2 1.836 1.791 1.425 1.396 0.254 0.191 1.126 1.209 0.374 0.355 Mean OD 450 (A) Calculated Cut off value (B) 1.814 0.544 INDEX A/B Interpretation 1.411 2.59 Positive 0.223 0.409 Negative 1.168 2.146 Positive 0.365 0.670 Negative QUALITY CONTROL The test run may be considered valid provided the following criteria are met: 1. The O.D. value of the reagent blank against air from a microwell reader should be less than 0.150. 2. If the O.D. value of the Calibrator is lower than 0.250, the test is not valid and must be repeated. 3. The IgG Index for Negative and Positive Control should be in the range stated on the labels DAI Code# 11 Page 4 of 6

INTERPRETATION Negative: H. pylori G Index of 0.90 or less are seronegative for IgG antibody to H. pylori. The serum sample may have been taken too early. Equivocal: H. pylori G Index of 0.91-0.99 is equivocal. Retest in a parallel fashion with a new serum sample drawn 3 weeks later. Positive: H. pylori G Index of 1.00 or greater are seropositive. PERFORMANCE CHARACTERISTICS A total of 347 patient samples were used to evaluate specificity and sensitivity of the test. The DIAGNOSTIC AUTOMATION INC. H. pylori IgG test results were compared to the endoscopic biopsy findings. DAI ELISA Endoscopic Biopsy N E P Total N 134(D) 0 2 (B) 136 E 6 0 5 11 P 4(C) 0 196(A) 200 Total 144 0 203 347 Sensitivity = A / (A + B) = 196 / 198 = 99% Specificity = D / (C + D) = 134 / 138 = 97% Accuracy = (A + D) / (A + B + C + D) = 330 / 336 = 98% The comparison of DIAGNOSTIC AUTOMATION INC. H. pylori IgG test to a commercial ELISA kit results are summarized. DAI ELISA Reference ELISA N E P Total N 96(D) 1 4 (B) 101 E 2 2 1 5 P 3(C) 0 105(A) 108 Total 101 3 110 214 Sensitivity = A / (A + B) = 107 / 109 = 96% Specificity = D / (C + D) = 96 / 99 = 97% Accuracy = (A + D) / (A + B + C + D) = 201 / 208 = 97% The precision of the assay was evaluated by testing three different sera eight replicates on 3 days. The intra-assay and inter-assay C.V. are summarized below: Negative Low positive Positive Intra-assay 9.1% 8.5% 6.4% Inter-assay 10.5% 8.9% 7.5% DAI Code# 11 Page 5 of 6

LIMITATIONS OF THE PROCEDURE 1. The assay should be used only to evaluate patients with clinical signs and symptoms suggestive of gastrointestinal disease. 2. A positive test result does not allow one to distinguish between active infection and colonization by H. pylori. It does not necessarily indicate that gastrointestinal disease is present. REFERENCES 1. Marshall, B.J. and J. R. Warren. Unidentified curved bacilli in the stomach of patients with gastritis and Peptic ulceration, Lancet 1:1311-1314, 1984. 2. Ruaws, E.A.J. and G.N.J. Tytgat. Cure of duodenal ulcer associated with eradication of Helicobacter pylori, Lancet 335:1233-35, 1990. 3. Perez-Perez, G.I., S.S. Wilkin, M.D. Decker and M.J. Blaswer. Seroprevalence of Helicobacter pylori infection in couples. J. Clin. Microbiol. 29:642-644, 1991. Date Adopted 2016-10-27 1503-11 DA-H.Pylori IgG DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 ISO 13485-2003 Revision Date: 2016-05-25 DAI Code# 11 Page 6 of 6