Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Similar documents
Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 2: Optic Nerve Head and Retinal

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Intro to Glaucoma/2006

Glaucoma Diagnosis. Definition of Glaucoma. Diagnosing Glaucoma. Vision Institute Annual Fall Conference

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

The Role of the RNFL in the Diagnosis of Glaucoma

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

OCT in the Diagnosis and Follow-up of Glaucoma

Evolving glaucoma management True diagnostic integration for the preservation of vision

Advances in OCT Murray Fingeret, OD

GLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES

Ganglion cell complex scan in the early prediction of glaucoma

Glaucoma: Diagnostic Modalities

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

21st Century Visual Field Testing

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Optical coherence tomography (OCT) is a noninvasive,

CLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

CHAPTER 13 CLINICAL CASES INTRODUCTION

CLINICAL SCIENCES. optic neuropathy characterized

Relationship Between Structure

Mark Dunbar: Disclosure

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

THE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS

Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)

Evaluating Optic Nerve Damage: Pearls and Pitfalls

1/25/2019 OCT & OCTA RETINAL IMAGING: HOW TO PREVENT RAGING GLAUCOMA! THE ORIGINAL RAGING GLAUCOMA OCT RETINAL IMAGING OPTIC NERVE HEAD EXAMINATION

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Is this glaucoma? Leo Semes, OD Michael Chaglasian, OD Danica Marrelli, OD. Optometry s Meeting 2015 Seattle, WA

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Evaluation of ONH Pallor in Glaucoma Patients and Suspects. Leticia Rousso, O.D. Joseph Sowka, O.D

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Jong Chul Han, Da Ye Choi, and Changwon Kee. 1. Introduction

EXPERIMENTAL AND THERAPEUTIC MEDICINE 6: , 2013

Assessment of Retinal Nerve Fiber Layer Changes by Cirrus High-definition Optical Coherence Tomography in Myopia

Question 1: Comment on the optic nerve appearance of each eye.

Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

Structural examina.on: Imaging

Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects

Sequential non-arteritic anterior ischemic optic neuropathy (NAION) Jonathan A. Micieli, MD Valérie Biousse, MD

RETINAL NERVE FIBER LAYER

How to Be Efficient and Effective. Disclosure. Topics CASE CM. Case JF 2007 OHTN / POAG? How to Be Efficient and Effective with. with New Technology

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

PREVALENCE OF GLAUCOMA AMONG FISHERMEN COMMUNITY OF MUNDRA TALUKA OF KUTCH DISTRICT- A CROSS- SECTIONAL STUDY

tracking progression we can better manage our patients. Like any tool, any instrument you ve got to

Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

THE STRUCTURE-FUNCTION JUNCTION

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

Linking structure and function in glaucoma

MATERIALS AND METHODS

Early Detection Of Glaucoma Clinical Clues. Points To Live By. Glaucoma Risk Factors 10/3/2014

10/27/2013. Optic Red Herrings

International Journal Of Basic And Applied Physiology

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION

The Optic Nerve Head In Glaucoma. Clinical Pearl #1. Characteristics of Normal Disk 9/26/2017. Initial detectable damage Structure vs function

Collaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012

New Concepts in Glaucoma Ben Gaddie, OD Moderator Murray Fingeret, OD Louis Pasquale, MD

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

Clinical Study Glaucoma Diagnostic Accuracy of Machine Learning Classifiers Using Retinal Nerve Fiber Layer and Optic Nerve Data from SD-OCT

OtticaFisiopatologica

Glaucoma THE STRUCTURE-FUNCTION JUNCTION. Measuring Structure and Function. Structure-Function Relationship. Structure-Function Relationship

A Review Of Risk Factors. Early Detection Of Glaucoma Clinical Clues. A risk factor analysis is critical. Points To Live By

Patterns of Subsequent Progression of Localized Retinal Nerve Fiber Layer Defects on Red-free Fundus Photographs in Normal-tension Glaucoma

OPTOMETRY RESEARCH PAPER

CLINICAL SCIENCES. (FDP) was designed to emphasize the response characteristics of the parasol

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

Rates of Abnormal Retinal Nerve Fiber Layer and Ganglion Cell Layer OCT Scans in Healthy Myopic Eyes: Cirrus Versus RTVue

CLINICAL SCIENCES. Effect of Partial Posterior Vitreous Detachment on Retinal Nerve Fiber Layer Thickness as Measured by Optical Coherence Tomography

Beyond the C/D Ratio: Evaluating a Glaucomatous Optic Nerve. Marcus Gonzales, OD, FAAO Cedar Springs Eye Clinic COPE ID#: GL

Relationship between GDx VCC and Stratus OCT in juvenile glaucoma

PRESCRIBING IN GLAUCOMA: GUIDELINES FOR NZ OPTOMETRISTS

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

Clinical decision making based on data from GDx: One year observations

Glaucoma Pearls and Grand Rounds Vision Expo East 2016

Optic Nerve: Clinical Examination

Early detection and control of disease progression or

PRACTICAL APPROACH TO MEDICAL MANAGEMENT OF GLAUCOMA

Peripapillary Retinal Thickness. Maps in the Evaluation of Glaucoma Patients: A Novel Concept.

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP

著者最終稿 (author final version) post.

Generally, myopia is a condition of the eye that makes it

Non-arteritic anterior ischemic optic neuropathy (NAION) with segmental optic disc edema. Jonathan A. Micieli, MD Valérie Biousse, MD

Transcription:

Original Article Philippine Journal of OPHTHALMOLOGY Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 1: Categorical Outcomes Based on a Normative Database Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD International Eye Institute St. Luke s Medical Center Quezon City, Philippines Correspondence: Noel Atienza, MD, MSc St. Luke s Medical Center Quezon City, Philippines Email: njatienza@yahoo.com Disclosure: Supported by a grant from the Research and Biotechnology Division of St. Luke s Medical Center. ABSTRACT Objective: To determine the accuracy of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) parameters using the Stratus OCT in diagnosing glaucoma among Filipino patients and to determine the validity of the OCT measurements compared with a reference standard. Methods: Glaucoma suspects were recruited consecutively from patients undergoing diagnostic tests. The results of the Stratus OCT fast RNFL protocol were analyzed against the independent assessment by glaucoma experts who were blinded. Outcomes included RNFL thickness values of 5 percentile and 1 percentile of the normative database for each RNFL sector, quadrant, and for the average RNFL thickness. Estimates of diagnostic accuracy with 95% confidence intervals were calculated. Results: A total of 119 subjects assessed as glaucoma and 397 subjects assessed as normal were included in the analysis. Using the best categorical criterion for abnormality (average RNFL thickness of 1 percentile of the normative database), the OCT had a specificity of 98% (95% CI 96-99) and a sensitivity of 37% (95% CI 28-46). The criterion with the highest sensitivity was the presence of at least one sector with thickness at 5 percentile. Conclusion: The Stratus OCT demonstrated a specificity of 98% and a sensitivity of 37% for the diagnosis of glaucoma using as a criterion an average RNFL thickness of 1 percentile of the normative database. It was a poor screening test for glaucoma suspects, although it showed some promise as a confirmatory test. Keywords: Glaucoma, Glaucoma suspects, Optical coherence tomography, Glaucoma imaging Philipp J Ophthalmol 2012; 37:3-10 January - June 2012

Glaucomatous optic nerve damage is a result of retinal ganglion cell (RGC) death with progressive loss of axons located in the retinal nerve fiber layer (RNFL). Several clinical studies showed that optic nerve head (ONH) damage and thinning of the RNFL occur earlier than the appearance of abnormalities in the visual field. 1 The European Glaucoma Society (EGS) stated in the 2008 Clinical Practice Guidelines that at least 50% of patients with glaucoma remain undiagnosed while more than 50% of patients currently receiving treatment for glaucoma do not actually have glaucoma. The EGS cited the need to improve on the sensitivity and specificity of diagnostic tests for glaucoma. 2 The newer diagnostic modalities, such as the optical coherence tomography (OCT), are primarily directed at demonstrating the presence of decreased thickness of the retinal nerve fiber layer (RNFL) around the optic nerve head in glaucoma patients. The OCT is an accurate and reproducible method that measures and analyzes RNFL thickness and ONH parameters to help differentiate glaucomatous eyes from normal eyes. In its most recent technology assessment published in 2007, the American Academy of Ophthalmology reviewed the evidence from articles related to the diagnosis of glaucoma using the OCT and other imaging devices. 3 A review of 159 articles on diagnostic studies showed that these were mostly Phase II studies with no independent masked comparison with a gold standard. The current best evidence from diagnostic studies on the OCT for glaucoma was level II evidence. There was no level I evidence from current published literature due to the lack of a masked independent comparison on a set of consecutive subjects that represented the target population for OCT testing. 3 The early models of the OCT had a dilemma of deriving the abnormal value using the quantitative data available from the OCT. A study by Budenz using the fast RNFL protocol on 109 normal and 63 glaucoma subjects determined the sensitivity and specificity of the Stratus OCT RNFL thickness measurements in diagnosing glaucoma using the standard automatic perimetry as the gold standard. 4 One major source of bias from this study was that the normal subjects did not undergo visual field testing. The researchers relied purely on a complete eye examination and the decision to perform the perimetry was determined by the clinical exam. Sensitivity and specificity estimates were determined without an independent blinded comparison with the reference standard. The sensitivity and specificity of the different parameters in the Stratus OCT are tabulated in Table 1, showing that it has high specificity and moderate sensitivity. At an average RNFL thickness measurement of <1 percentile, the sensitivity was only 68% and the highest sensitivity achieved using either one quadrant or sector at <5 percentile was 89% (Table 1). Budenz also recommended that studies on the OCT be performed on specific populations since RNFL differences were noted between ethnic groups. Statistical adjustments were recommended for RNFL parameters in order to provide better sensitivity and specificity for glaucoma detection among these specific target populations. 5 This study, therefore, determined the accuracy of the ONH and RNFL parameters using the Stratus OCT in diagnosing glaucoma among Filipino suspects. It was a cross-sectional diagnostic validation study with a phase 3 design 6 that analyzed the ability of the OCT to assess patients that represented the target population. METHODOLOGY This validation study focused on the OCT parameters using the fast optic disc and fast RNFL protocols of the Stratus OCT machine as applied to glaucoma suspects. A prospective recruitment of glaucoma suspects was undertaken from September Table 1. Sensitivity and Specificity of the Stratus OCT (Budenz, 2005). 4 Criteria for Sensitivity Specificity Abnormality (95% CI) (95% CI) Average RNFL 84% (75-93) 98% (96-100) <5 percentile Average RNFL 68% (57-80) 100% <1 percentile 1 quadrant with RNFL 89% (81-97) 95% (90-99) <5 percentile 1 quadrant with RNFL 83% (73-92) 100% <1 percentile 1 clock hour RNFL 89% (81-97) 92% (87-97) <5 percentile 1 clock hour RNFL 83% (73-92) 100% <1 percentile 4 Philippine Academy of Ophthalmology

Philippine Journal of OPHTHALMOLOGY 2008 to October 2010 at the St. Luke s International Eye Institute. Subjects were enrolled based on the inclusion and exclusion criteria enumerated below. Inclusion Criteria Patients were Filipinos aged 20 years or older with best corrected visual acuity of at least 20/40. A glaucoma suspect was defined as a patient with probable glaucomatous optic neuropathy based on the presence of any of the following findings on clinical examination: 1. Increased intraocular pressure (IOP 23 mmhg by applanation tonometry); 2. Optic cup-to-disc ratio greater than 0.5; 3. Optic cup-to-disc ratio asymmetry of >0.2; 4. Suspicious optic disc findings, such as thinning or notching of the neuroretinal rim, bayoneting of the optic nerve head vessels, and optic disc hemorrhage; 5. Loss of the RNFL reflex ( RNFL drop-out ), especially on the superior and inferior areas of the ONH; 6. A history of iridescent vision, ocular pain and redness accompanied by corneal edema, and a middilated pupil. Exclusion Criteria Subjects were excluded when any of the following were present: 1. Best corrected visual acuity worse that 20/40; 2. Presence of eye conditions that can affect the visual fields, such as neuroophthalmologic conditions, diabetic retinopathy, chorioretinitis, and maculopathy; 3. Severe glaucomatous cupping of 1.0 and a tunnel vision with remaining visual field of less than 3 degrees; 4. Previously diagnosed cases of chronic glaucoma with established glaucomatous visual field defects on perimetry. Sample Size Determination The sample size was determined based on a previous study that reported an overall sensitivity of 77% and a specificity of 77% 1. With a margin of error of 5%, and a 95% confidence level, the minimum sample size required to estimate the sensitivity was computed as: n = (0.77)(1 0.77) [1.96]2/(.05)2 or n = 272 subjects per group. The same number was needed to estimate specificity. A prevalence of 50% was assumed based on the opinion of glaucoma specialists. The total sample size was estimated at 544 subjects: n / 0.5 = 272 / 0.5 = 544 total subjects Ethical Considerations The study was approved by the institutional scientific and ethics board of the St. Luke s Medical Center Q.C. The protocol conformed to the Declaration of Helsinki. An informed consent was secured from all patients which ensured confidentiality of data. Data Collection Baseline data collected during the screening included the following: age, gender, refractive error (spherical equivalent), snellen visual acuity, intraocular pressure by applanation tonometry, and chamber angle by gonioscopy. Patients underwent the following diagnostic tests on the same day: 1. Standard automated perimetry (SAP) (Octopus or Humphrey perimetry); 2. Optical coherence tomography (Stratus OCT Model 3000, Carl Zeiss Meditec, Dublin, CA with Version 4.0.1 Software) using the fast optic disc and fast RNFL (3.4) protocols; 3. Optic nerve head photography with a Zeiss fundus camera and VISUPAC system. Figure 1 shows the flowchart of diagnostic procedures starting from screening to the different glaucoma tests. Standard automated perimetry (SAP) was done using either the Octopus 101 (G2 program) or the Humphrey Field Analyzer (central 30-2 test, size III white stimulus, Sita-standard strategy). The fast optic disc protocol included six 4-mm radial linear scans centered on the optic disc and acquired in 1.92 seconds which produced two printouts: the Individual Radial Scan Analysis and the Optic Nerve Head Analysis. The fast RNFL protocol included three 3.4-mm circular scans centered on the optic disc and acquired in 1.92 seconds which produced the Fast RNFL Analysis printout. The reference standard determination was performed by two glaucoma specialists who were blinded to the OCT results and who independently examined the clinical records, the optic disc images January - June 2012 5

Test Arm OCT Analyses Data Encoding Screening/Interview Slit Lamp Examination/ Refraction/Visual Acuity/Tonometry/ Gonioscopy/ Funduscopy Standard Automated Perimetry (Octopus or Humphrey) Stratus OCT: Fast Optic Disc / Fast RNFL Protocols Stereoscopic Optic Disc Photography Figure 1. Flowchart of diagnostic procedures. Reference Arm Clinical Data: Age, Visual acuity, Intraocular Pressure, Angle Visual Field Analyses Optic Disc Color and Red Free Photos Clinical Assessment by Glaucoma Experts on standard photos, and the results of the visual field tests. Each assessor gave his assessment without knowledge of the other expert assessment, and a diagnosis of glaucoma or no glaucoma was made based on a consensus of the two glaucoma specialists. In cases of disagreement, a third glaucoma expert was consulted to resolve the disagreements by an independent examination. The glaucoma specialists based their assessment of glaucoma on the presence of any of the following features: 1) Optic cupping to the disc margin with associated enlargement of peripapillary atrophy with or without detectable abnormalities on SAP; 2) Abnormalities of the optic nerve head characteristic of glaucomatous excavation, such as notching, disc asymmetry of more than 0.2 between the two eyes, focal or diffuse atrophy of the RNFL, vertical cup/ disc ratio of more than 0.6; and 3) An abnormal visual field on SAP characteristic of glaucoma with a minimum criteria of: a cluster of three or more nonedge points in a location typical for glaucoma, all of which were depressed on pattern deviation plot at p<.05 level and one of which was depressed at p<.01 level. The absence of all of the above conditions was the basis for an assessment of no glaucoma or normal. One eye per subject was included in the analyses. In cases of unilateral disease, the diseased eye was chosen. In cases where one eye was excluded due to severe glaucoma, the other eye was included. In all other cases of bilateral glaucoma and for normal subjects, one eye was chosen at random using a computer generated code. Statistical Analysis: Categorical Outcomes Categorical outcomes for the OCT were encoded based on the color-coded results from the OCT RNFL printouts. Red highlighted values had RNFL thickness values of 1 percentile of the normative database. Yellow highlighted values had thickness values of 5 percentile but >1 percentile of the normative database. Six different criteria for abnormality were defined as a basis for a determination of normal or abnormal OCT results. These were, namely; 1. Average RNFL thickness 1 percentile 2. Average RNFL thickness 5 percentile 3. The presence of at least one quadrant 1 percentile 4. The presence of at least one quadrant 5 percentile 5. The presence of at least one clock hour sector 1 percentile 6. The presence of at least one clock hour sector 5 percentile Outcome results for the OCT were encoded for each of the six criteria for all subjects. An abnormal value at 5 percentile included OCT results colorcoded yellow or red. An abnormal value at 1 percentile included OCT results color-coded red only. All green-coded results were considered within normal. The baseline data, the categorical OCT outcomes, and the results of the expert assessment were analyzed using the SPSS version 16.0 software. For the categorical outcomes, estimates of diagnostic accuracy were determined with a 95% confidence interval. The following estimates of diagnostic accuracy were computed: sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratio for a positive result, and the likelihood ratio for a negative result. RESULTS A total of 547 glaucoma suspects were screened and tested, and 31 subjects were excluded from the final analysis (Figure 2). The reasons for these exclusions were: 10 were less than 20 years; 10 had findings highly suggestive of a neuroophthalmological condition; 9 had retinal disease and pathologic myopia; 2 6 Philippine Academy of Ophthalmology

Philippine Journal of OPHTHALMOLOGY Standard Automated Perimetry and Optic Disc Photography Gold standard: Clinical Assessment 547 Subjects Screened had advanced bilateral glaucoma. Optical Coherence Tomography 10 Subjects Excluded Age <20 years 21 Subjects Excluded: 2 subjects - Advanced Glaucoma 9 subjects - Retinal Disease 10 subjects - Neuroophthalmologic Disease 516 Subjects Included in the Analysis Glaucoma (119) No Glaucoma (379) Figure 2. Flowchart of the study recruitment process. The age of the sample ranged from 20 to 93 years, with a mean of 52.7 years (±12.9). There were 327 female (63.4%) and 189 (36.6%) male subjects. The subjects were also categorized into age brackets similar to the normative database of the OCT. The 40-49, 50-59, and 60-69 year age categories contained 399 subjects which comprised 77.3% of the total sample (Table 1). All 516 subjects included in the analysis had open anterior chamber angles. There were no cases of acute or chronic angle closure glaucoma. Intraocular pressures were within normal in 471 eyes (91.3%) and were elevated (IOP >22 mmhg) in 45 eyes (8.7%). The refractive errors of the sample had a mean spherical equivalent of -0.07sph (±1.84sph) and median of 0.00sph. Two glaucoma specialists (AT and JM) examined the datasets of 547 subjects (1094 eyes). There was agreement in the status of 972 eyes (88.8%) and disagreement in 122 eyes. A third glaucoma expert (ML) examined the datasets and gave the final assessment for the 122 eyes. Of the 516 subjects included in the analyses, 119 eyes (23.1%) were diagnosed to have glaucomatous optic neuropathy and 397 eyes (76.9%) were classified as normal. The mean age for the glaucoma group was 58.7 years (±10.9) and for the normal group 50.9 years (±12.9); this difference was statistically significant (p=0.03). The glaucoma patients were older than the normal patients by a mean difference of 7.8 years (95% CI:5.2 10.3). Among the 45 eyes with elevated IOP, 19(42.2%) were assessed to have glaucoma. Among the 471 eyes with normal IOP, 100(21.2%) were assessed to have glaucoma. The mean IOP for the glaucoma eyes was 18.1 mmhg (±7.3) and for the normal eyes 16.7 mmhg (±4.2). The t-test for the difference in means was significant with a mean IOP difference of 1.4 mm Hg (95% CI: 0.37 2.47). Table 1. Age Distribution of the Study Sample Divided into Categories by Decades (n=516). Age Category (years) Frequency (%) 19 29 24 (4.7%) 30 39 60 (11.6%) 40 49 116 (22.5%) 50 59 147 (28.5%) 60 69 136 (26.4%) 70 79 26 (5.0%) 80 94 7 (1.4%) Total 516 Table 2. Distribution in Age, Gender, and IOP Between the Glaucoma and No Glaucoma Groups. Totals No Characteristic Glaucoma Glaucoma (%) a n=119 (%) a n=397 Age (years) 19-29 0 (0%) 24 (100%) 24 30-39 9 (15%) 51 (85%) 60 40-49 15 (13%) 101 (87%) 116 50-59 31 (21%) 116 (79%) 147 60-69 49 (36%) 87 (64%) 136 70-79 13 (50%) 13 (50%) 26 80-94 2 (29%) 5 (71%) 7 Gender Male 64 (34%) 125 (66%) 189 Female 55 (17%) 272 (83%) 327 Intraocular pressure Elevated IOP 19 (42%) 26 (58%) 45 Normal IOP 100 (21%) 371 (79%) 471 a row percentages January - June 2012 7

The mean refractive error in the glaucoma group was -0.26 sph (±1.73) and in the normal group -0.01 (±1.87). The glaucoma group was slightly more myopic (Mean difference: -0.25 sph, 95% CI: -0.62-0.13) but the difference was not statistically significant (p=0.37). The average RNFL thickness was the OCT parameter that served as a global index for the fast RNFL protocol. Table 3 shows the 2 x 2 contingency table values for the six different criteria for abnormality. The criterion with the highest sensitivity (or true positive rate) was at least 1 sector at 5 percentile with a value of 73%. The criterion with the highest specificity was the average RNFL thickness at 1 percentile with a value of 98%. Table 3. Comparative 2x2 Contingency Table for the Six Different Criteria for Abnormality in RNFL Thickness (N=516). Criteria for Sensitivity Specificity RNFL (True False False (True Thickness Positive Positive Negative Negative Below Normal Rate) Rate Rate Rate) Ave RNFL Thickness 44 (37%) 9 (2%) 75 (63%) 388 (98%) 1 Ave RNFL Thickness 56 (47%) 28 (7%) 63 (53%) 369 (93%) 5 percentile At least 1 RNFL Quadrant 49 (41%) 18 (5%) 70 (59%) 379 (95%) 1 At least 1 RNFL Quadrant 64 (54%) 57 (14%) 55 (46%) 340 (86%) 5 At least 1 RNFL Sector 61 (51%) 35 (9.6%) 58 (49%) 362 (91.2%) 1 At least 1 RNFL Sector 87 (73%) 91 (23%) 32 (27%) 306 (77%) 5 Table 4. Statistical Estimates and Predictive Values for the Six Different Criteria for Abnormality in RNFL Thickness (N=516). OCT LR LR Abnormal- Sensitivity Specificity Positive Negative ity Criteria (95% CI) (95% CI) (95% CI) (95% CI) Ave 37% 98% 16.31 0.64 Thickness 1 (28 46) (96 99) (8.20 32.43) (0.56 0.74) Ave 47% 93% 6.67 0.57 Thickness 5 (38-56) (90-95) (4.45 10.00) (0.48 0.68) 1 Quad- 41% 95% 9.08 0.62 rant RNFL 1 (32 50) (93 98) (5.51 14.97) (0.53 0.72) 1 Quad- 54% 86% 3.75 0.54 rant RNFL 5 (45 63) (82 89) (2.8 5.02) (0.44 0.66) 1 Sector 51% 91% 5.81 0.53 RNFL 1 (42 60) (88 94) (4.05 8.35) (0.44 0.64) 1 Sector 73% 77% 3.19 0.35 RNFL 5 (65 81) (73 81) (2.58 3.94) (0.26 0.47) Sensitivity, specificity, and likelihood ratios were computed for each of the six criteria with 95% confidence intervals (Table 4). Sensitivity values ranged from 37% to 73%, while the specificity values ranged from 77 to 98%. When the criteria for abnormality was 1 percentile, the sensitivity was also lower while the specificity became higher when compared with the 5 percentile criteria. None of the six criteria exhibited high values for both sensitivity and specificity. Confidence intervals for the sensitivity were wide in comparison to the narrow confidence intervals of the estimates for specificity. This could be due to the low prevalence of glaucoma (23%) in this study. The sample size was computed with a projected prevalence of 50%, and the narrow intervals for the specificity was due to 8 Philippine Academy of Ophthalmology

Philippine Journal of OPHTHALMOLOGY the larger percentage of subjects assessed to have no glaucoma. High likelihood ratios for positive results were seen in the average thickness (LR+ 16.3) and quadrant average (9.08) at 1 percentile of the normative database. The outcome with the highest sensitivity of 73% was the presence of at least one clock-hour sector at 5% of the normative database, but this was accompanied by a lower specificity of 77%. DISCUSSION The Phase 3 diagnostic study design assessed the ability of the OCT to discriminate between glaucoma and normal patients from among glaucoma suspects that best represented the target population. The inclusion and exclusion criteria used for the study were designed to ensure the presence of diagnostic uncertainty. The exclusion of patients with established field defects or with far advanced glaucoma were aimed at producing a population with an intention to diagnose glaucoma. The resulting prevalence of 23% from the sample of glaucoma suspects was lower than the projected 50% used in the determination of the sample size. The relatively low prevalence of glaucoma in the study explained the low accuracy of the estimates of sensitivity and positive predictive value. In contrast, the larger number of normal subjects resulted in narrow confidence intervals for the specificity and the negative predictive values of the OCT. Accuracy of the OCT in the Diagnosis of Glaucoma The most salient observation derived from the study was a high specificity of 98% and a low sensitivity of 37% when using the categorical outcome of average thickness at 1 percentile as the criterion for abnormality. The high specificity of the OCT was accompanied by a low false-positive rate, with only 9 false-positive readings out of 397 normal subjects. In contrast, there was a high false-negative rate of 63% with 75 diagnosed glaucoma subjects classified as normal based on the stop-sign color scheme of the Stratus OCT. Considering that the stoplight color coding was applied to the sectors, quadrants, and the average thickness, the OCT will at best be able to confirm glaucoma in three out of four cases. Using the most sensitive criterion (at least one RNFL sector at 5 percentile), the OCT will falsely classify 1 in 4 glaucoma cases as being normal and will also misdiagnose 1 in 4 normal subjects as having glaucoma. The SpPin (Specificity is so high that a Positive result rules in the diagnosis) principle applies to the OCT because with its high specificity a positive result will virtually rule-in the disease. On the other hand, the SnNout (Sensitivity is so high that a Negative result rules out the diagnosis) principle cannot be applied to the OCT because with a low sensitivity a negative result may not rule out the disease. Thus, the OCT is a poor screening test for glaucoma suspects, although it showed some promise as a confirmatory test. The sensitivity estimates found in our study were much lower than those from previous studies by Hougard (72% sensitivity and 95% specificity) 7 and Budenz (68% sensitivity and 100% specificity) 6. The decrease in performance of the OCT in our study was partly because of the inclusion criteria that focused on glaucoma suspects. The studies by Hougard and Budenz were Phase 2 studies on known normal and glaucomatous eyes. The normal subjects used in these studies had no suspicious findings of the disease and were generally required to have normal optic disc appearance. In contrast, the normal subjects in our study had suspicious optic discs. A clinician using the OCT software and its stoplightcoded outputs would have difficulty in differentiating the normal subjects from those with definite glaucoma. The objective of this study was to estimate global test performance using the stoplight color-coded printouts of the OCT. These were based on the normative database derived for the OCT. The estimates of test accuracy and validity may have been affected by the choice of the reference standard. Sensitivity is underestimated most when the prevalence of the condition is low. Miscalculation of the reference standard will tend to result in underestimation of test accuracy. The gold standard used in this study placed much importance on expert clinical assessment of the optic nerve head and the SAP. The criteria for a positive diagnosis of glaucoma include a combination of structural and functional evidence such that a diagnosis of glaucoma could be made with certainty with or without an accompanying visual field defect. The visual field defect must also be typically January - June 2012 9

glaucomatous. Thus, the global indices were less useful for this study. There is no widely accepted gold standard for the diagnosis of glaucoma. 4 In future researches, it is essential that a gold standard for the definition of glaucoma be established. One possible gold standard would be the clinical evidence of progression of glaucomatous damage. Much research has been done on repeated visual field assessment to document evidence of progression in field damage. It is possible that the Stratus OCT and other imaging devices, such as the HRT II and the Cirrus OCT, will be used in future research in glaucoma diagnostics. The architecture of diagnostic research. Br Med J 2002; 321:539-541. 7. Hougaard JL, Heijl A, Bengtsson B. Glaucoma detection by Stratus OCT. J Glaucoma 2007; 16:302-306. In summary, glaucoma suspects undergoing the OCT cannot be assessed for the presence of glaucoma based purely on the results of the OCT. The Stratus OCT using the fast RNFL protocol with its internal software gave categorical results with high specificity but low sensitivity. At the present time, the Stratus OCT cannot replace the gold standard of clinical assessment of structural and functional damage in the diagnosis of glaucoma. Because of its high specificity, the Stratus OCT may be used as a confirmatory test. With its low sensitivity, the OCT may not be useful as a screening test for glaucoma suspects. Acknowledgements We would like to thank Dr. Jose Ma. Martinez and Dr. Margaret Lat-Luna who served as the glaucoma experts for this study, together with Dr Tumbocon. Statistical analyses were performed in consultation with Dr. Jacinto Blas Mantaring and Prof. Cynthia Cordero from the Department of Clinical Epidemiology at the UP College of Medicine. REFERENCES 1. American Academy of Ophthalmology. Ophthalmic Procedures Assessment: Optic nerve head and retinal nerve fiber layer analysis - a report by the American Academy of Ophthalmology. Ophthalmology 1999;106:1414-1424. 2. European Glaucoma Society (EGS). Terminologies and Guidelines for Glaucoma, 3rd ed, 2008. Downloadable from www.eugs.org. 3. American Academy of Ophthalmology. Ophthalmic Procedures Assessment: Optic nerve head and retinal nerve fiber layer analysis: a report by the American Academy of Ophthalmology. Ophthalmology 2007;114:1937 1949. 4. Budenz DL, Michael A, Chang RT, et al. Sensitivity and specificity of the Stratus OCT for perimetric glaucoma. Ophthalmology 2005;112:3 9. 5. Budenz DL, Anderson DR, Varma R, et al. Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. Ophthalmology 2007;114:1046-52. 6. Sackett DL, Haynes RB. Evidence base of clinical diagnosis: 10 Philippine Academy of Ophthalmology