ORIGINAL PAPER. Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms

Similar documents
A Novel Technique of Microcatheter Shaping with Cerebral Aneurysmal Coil Embolization: In Vivo Printing Method

Usefulness of Coil-assisted Technique in Treating Wide-neck Intracranial Aneurysms: Neck-bridge Procedure Using the Coil Mass as a Support

ORIGINAL PAPER. 8-F balloon guide catheter for embolization of anterior circulation aneurysms: an institutional experience in 152 patients

Coil Embolization of Cerebral Tiny Aneurysms

Single-stage Coil Embolization for Kissing Aneurysms of the Internal Carotid Artery Using Enterprise Stent: Three Cases Reports

Three Cases with Wide-necked Cerebral Aneurysms in Whom the T-stent Technique Was Useful

Coiling of ruptured and unruptured intracranial aneurysms

CASE REPORT. Alpha horizontal stent delivery for coil embolization of a broad-necked large basilar apex aneurysm: a case report

Practical Feasibility and Packing Density of Endovascular Coiling Using Target Nano TM Coils in Small Cerebral

Pipeline Embolization Device

Endovascular treatment of intracranial aneurysms with bare

Long term follow-up of patients with coiled intracranial aneurysms Sprengers, M.E.S.

Repair of Intracranial Vessel Perforation with Onyx-18 Using an Exovascular Retreating Catheter Technique

Shallow aneurysms with wide necks pose a technical challenge

Endovascular treatment is increasingly used for ruptured

CASE REPORT. Department of Neurosurgery, Kariya Toyota General Hospital, Kariya, Japan ABSTRACT

Shallow aneurysms with wide necks pose a technical challenge

Report of Flow Diverter Clinical Trials in Japan

Endovascular treatment with coils has become an established

The Importance of Coil Packing

Subarachnoid hemorrhage secondary to ruptured intracranial

Posterior Cerebral Artery Aneurysms with Common Carotid Artery Occlusion: A Report of Two Cases

NIH Public Access Author Manuscript J Am Coll Radiol. Author manuscript; available in PMC 2013 June 24.

Endovascular treatment of intracranial aneurysms by coiling

Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm: A Case Report

Endovascular treatment (EVT) of intracranial aneurysms is an

Ex Vivo Release of Pipeline Embolization Device Polytetrafluoroethylene Sleeves: A Technical Note

Initial Experience with the New Double-lumen Scepter Balloon Catheter for Treatment of Wide-necked Aneurysms

A Case of Retrieval of a Migrated Coil with a Stent Retriever

Endovascular Embolization of Large Internal Carotid Artery Aneurysms: Single-center Experience with 10 Cases and Literature Review

Role, safety, and efficacy of WEB flow disruption: a review

CERECYTE Microcoils: Accessories: MICRUSPHERE Microcoil. PRESIDIO Microcoil. CASHMERE Microcoil. DELTAPAQ Microcoil. DELTAPLUSH Microcoil

THE POWER OF HYDROGEL

Kissing Aneurysms at Fenestrated Proximal Basilar Artery: Double-barrel Stent-assisted Coiling Using Dual Closed-cell Stents

Endovascular coil embolization of cerebral aneurysms is associated

Irretrievable unraveled coil remaining in the vascular lumen between the cerebral aneurysm and puncture site

Endovascular embolization of intracranial aneurysms

A single center comparison of coiling versus stent assisted coiling in 90 consecutive paraophthalmic region aneurysms

Mechanical Thrombectomy of Large Vessel Occlusions Using Stent Retriever Devices

Endosaccular aneurysm occlusion with Guglielmi detachable coils for obstructive hydrocephalus caused by a large basilar tip aneurysm Case report

Superior cerebellar artery aneurysms: incidence, clinical presentation and midterm outcome of endovascular treatment

RESEARCH HUMAN CLINICAL STUDIES

UPSTATE Comprehensive Stroke Center

Y-Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms

Use of a Flow Re-direction Endoluminal Device (FRED) for Wide-neck Large/Giant Cerebral Aneurysms

Making the difference with Live Image Guidance

Endovascular techniques have been gaining ground in the

Endovascular Treatment of Intracranial Anterior Circulation Aneurysms with Flow Diverters: A Single Centre Experience with Mid- and Long-Term Results

Endovascular therapy is a well-established treatment

12/5/2016. New Frontiers in Flow Diversion. Concepts for endovascular treatment of aneurysms. Disclosures:

Making the difference with Live Image Guidance

Ruptured intracranial vertebral confluence

Endovascular coiling for cerebral aneurysm: single-center experience in Egypt

Introducing a New Treatment Method for Brain Aneurysms

Aneurysms of the posterior inferior cerebellar artery

FDA Executive Summary

Y-Stent Assisted Coil Embolisation of Wide-Necked Aneurysms Using a New Fully Retrievable and Detachable Intracranial Stent: Report of Two Cases

Selective Endovascular Treatment of Intracranial Aneurysms with a Liquid Embolic: A Single-Center Experience in 39 Patients with 41 Aneurysms

Overview of Coil Trials and Registries

Horizontal Stent Assisted Coiling of Wide Neck Basilar Tip Aneurysm: Comparison of Two Cases

Ruptured aberrant internal carotid artery pseudoaneurysm presenting with spontaneous massive ear bleeding following a single sneeze: a case report

Embolization with detachable coils is a safe and effective

Initial experience with implantation of novel dual layer flow-diverter device FRED

Risk factors for the recurrence of an intracranial saccular aneurysm following endovascular treatment

Endovascular embolization with detachable coils has become

Large and giant aneurysms are associated with much worse outcomes

ORIGINAL PAPER. Overlap stenting for in-stent restenosis after carotid artery stenting

Endovascular coil embolization of cerebral aneurysms is now

The self-expandable Neuroform2 stent (Boston Scientific,

Novel non-occlusive temporary endoluminal neck protection device to assist in the treatment of aneurysms in a canine model

The treatment of wide-neck and giant intracranial aneurysms

Yoshikazu Matsuda, 1,2 Joonho Chung, 1,3 Kiffon Keigher, 1 Demetrius Lopes 1 ORIGINAL RESEARCH. New devices

Long-term effects of antiplatelet drugs on aneurysm occlusion after endovascular treatment

Endovascular treatment is now the first-line approach for both

Intravascular stents for intracranial internal carotid and vertebral artery aneurysms: preliminary clinical experience

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

SHA aneurysms are rare. They arise from the internal carotid

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

Late Reopening of Adequately Coiled Intracranial Aneurysms Frequency and Risk Factors in 400 Patients With 440 Aneurysms

COIL EMBOLIZATION OF WIDE NECK CEREBRAL ANEURYSMS USING BALLOON REMODELING TECHNIQUE-INITIAL EXPERIENCE IN PAKISTAN

WLNC 2018 ISTANBUL CASES

Treatment of Small Ruptured Intracranial Aneurysms: Comparison of Surgical and Endovascular Options

Epidemiology And Treatment Of Cerebral Aneurysms At An Australian Tertiary Level Hospital

Interlocking Detachable Coil Occlusion in the Endovascular Treatment of Intracranial Aneurysms: Preliminary Results

Comparison between Solitaire AB and Enterprise stent assisted coiling for intracranial aneurysms

Endovascular treatment of cerebral aneurysms using the Woven EndoBridge technique in a single center: preliminary results

Techniques in cerebral aneurysm surgery

Studying Aneurysm Devices in the Intracranial Neurovasculature

Spontaneous Recanalization after Complete Occlusion of the Common Carotid Artery with Subsequent Embolic Ischemic Stroke

Contaminated Wound: Report of a Cas

Endovascular Treatment of Symptomatic Vertebral Artery Dissecting Aneurysms

First experience in intracranial aneurysm occlusion by balloon assisted coiling technique

Published December 16, 2010 as /ajnr.A2314

Case Report. Case Report

Long term follow-up after endovascular treatment for intracranial aneurysms. Bart Emmer, MD, PhD

The incidence of subarachnoid hemorrhage (SAH) increases

Beneficial Remodeling of Small Saccular Intracranial Aneurysms after Staged Stent Only Treatment: A Case Series

Department of Neurosurgery, Juntendo University Faculty of Medicine, Tokyo, Japan; 2

Transcription:

Nagoya J. Med. Sci. 79. 505 ~ 513, 2017 doi:10.18999/nagjms.79.4.505 ORIGINAL PAPER Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms Tomotaka Ohshima 1, Shunsaku Goto 1, Taiki Yamamoto 1 and Kojiro Ishikawa 1 1 Department of Neurosurgery, Kariya Toyota General Hospital, Kariya, Japan ABSTRACT Despite major developments in treating intracranial aneurysms by endovascular coil embolization, complete occlusion of the entire aneurysmal neck remains a problem. We present a novel endovascular strategy for middle- and large sized aneurysms called the hemispheric divided coiling technique and compare the short-term follow-up results of this technique with those of conventional coil embolization. Ten patients (mean age, 69.7 ± 9.7 years) with middle- or large-sized ruptured or unruptured intracranial aneurysms (mean maximum aneurysmal diameter, 12.09 ± 3.6 mm) were treated by the hemispheric divided coiling technique, in combination with various adjunctive techniques. We compared the initial occlusion grade, volume embolization ratio, and recurrence rate in this group of patients (hemispheric group) with the results from 20 previous cases (conventional group: mean age, 62.8 ± 9.8 years; mean maximum aneurysmal diameter, 11.43 ± 3.5 mm). The mean volume embolization ratio of the hemispheric group was significantly higher than that of the conventional group (42.3% vs. 31.1%). The hemispheric divided coiling technique achieved a high volume embolization ratio for middle- and large sized intracranial aneurysms, with a low recurrence rate. Keywords: coil embolization, endovascular treatment, intracranial aneurysms This is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (http://creativecommons.org/licenses/by-nc-nd/4.0/). INTRODUCTION A higher volume embolization ratio after coil embolization for intracranial aneurysms is a factor involved in the prevention of recanalization and re-enlargement. 1,2) To achieve a high embolization rate, various techniques have been developed, such as bioactive coils and stent-assist technique. 3,4) However, large and giant aneurysms remain difficult to treat with a single procedure. We recently developed a hemispheric divided coiling technique to obliterate aneurysms by achieving a high volume embolization ratio. Here, we report the technical details of this procedure and compare the clinical outcomes and recurrence rates between aneurysm cases treated by the hemispheric divided coiling technique and matched cases treated by conventional coil embolization. Received: July 14, 2017; accepted: August 28, 2017 Corresponding author: Tomotaka Ohshima, M.D., Ph.D. Department of Neurosurgery, Kariya Toyota General Hospital 5-15 Sumiyoshi-cho, Kariya, Aichi 448-8505, Japan Phone: +81-566-21-2450, fax: +81-566-22-2493, e-mail: tmtkoh@gmail.com 505

506 Tomotaka Ohshima et al. MATERIALS AND METHODS Subjects This study was a retrospective analysis of 30 patients with middle- or large-sized aneurysms who received endovascular treatment at our hospital between January 2015 and May 2016. Middle- or large-sized aneurysms were defined as those with a maximum diameter between 7.0 and 25.0 mm. After January 2016, 10 of these 30 patients were treated with the hemispheric divided coiling technique (the hemispheric group). Before January 2016, 20 patients were treated by the conventional method, in which coils were inserted like an onion skin, with or without adjunctive techniques (the conventional group). Nine of the 30 patients (four in the hemispheric group and five in the conventional group) had ruptured aneurysms. Clinical outcomes, including initial occlusion grade, volume embolization ratio, and recurrence rate, were compared between the hemispheric and conventional groups. Aneurysmal evaluation Aneurysmal size was measured in three directions (height, length, and width) by 3D rotation cerebral angiography with a biplane angiograph (GE Healthcare, CT, USA). The degree of embolism was evaluated by the Raymond scale (RS) 5) : RS1, complete occlusion; RS2, aneurysmal neck remnant; and RS3, intra-aneurysmal contrast enhancement remnant (RS2 and RS3, incomplete occlusion). Aneurysmal volume and volume embolization ratio were calculated by the following formulae: Aneurysmal volume (mm 3 ) = 4/3π (length/2) (width/2) (height/2) Volume embolization ratio (%) = Σ { π (coil diameter/2) 2 coil length} /aneurysmal volume 100 For posttreatment assessment, 1.5T MRI and plain X-rays of the head were performed. The former was performed immediately after treatment and after 1 and 6 months. The latter was performed immediately after treatment, 1 week after treatment, and after 1 and 6 months. In patients with incomplete embolization, MRI was also performed 3 months after treatment. Patients with an increase in high intensity in the aneurysm on MR angiogram in comparison with that immediately after treatment or deformity of the coil mass on plain X-ray of the head were regarded as having recurrent aneurysms. In patients with suspected recurrence, cerebral catheter angiography was performed, and when there was a marked increase in intra-aneurysmal blood flow in comparison with that immediately after previous treatment, additional treatment was performed. Technical details of the hemispheric divided coiling technique This technique uses a single microcatheter with or without a stent. After the conventional frame with the first coil is made, the second coil is selected with half the diameter of the first coil. Then, it is deployed into the part of the aneurysmal fundus (Fig. 1). Next, the distal hemisphere is embolized by the conventional procedure. When the distal hemisphere is occluded, the proximal part is embolized with the conventional technique. The hemispheric divided coiling technique is aimed preventing early kick-out of the microcatheter and leaving a substantial coil-free dead space. In particular, when the microcatheter is unstable in the aneurysm, this technique allows it to stay in position until at least the distal hemisphere is occluded. In cases of stent-assist embolization, the jailed microcatheter should be retained as long as possible. Moreover, if the framing coil is vulnerable, this technique ensures that it is not broken by the following coils. Tightening of the unstable frame at the fundus with the second and third coils makes the frame rigid. Finally, a higher volume embolization can be achieved than with the conventional onion

Hemispheric divided coiling 507 Fig. 1 Schematic drawing of the hemispheric divided coiling technique. (A) After a frame has been made by the usual technique, the microcatheter is set around the center of the aneurysm. (B) A second coil is selected with half the diameter of the first coil. (C) The distal hemisphere is embolized by the conventional procedure before the proximal hemisphere. (D) When the distal hemisphere is occluded, the proximal part is embolized by the conventional technique. skin insertion technique. Statistical analysis The details of patient characteristics and clinical results are presented as means ± standard deviation for continuous variables and numbers (percentage) for categorical variables. Bivariate comparisons between the conventional and the hemispheric group used the unpaired t-test for continuous data, and Fisher s exact test for categorical data. For all statistical analyses, P < 0.05 was considered to indicate statistical significance. RESULTS The mean age of the patients was 65.1 ± 9.7 years, and 67% were women. A detailed summary of patient demographic and clinical characteristics is presented in Table 1. There were no significant differences between the two groups in age (P = 0.17), sex ratio (P = 0.58), proportion of ruptured aneurysms (P = 0.39), dome/neck ratio (P = 0.59), or maximum aneurysmal diameter (P = 0.72). In both groups, the most common location of the aneurysm was the internal carotid artery. The results of treatment are shown in Table 2. In all patients, the procedures were successfully performed. The mean volume embolization ratio in the conventional and hemispheric groups was 31.1% ± 3.6% and 42.3% ± 7.4%, respectively, with a significant difference between groups (P = 0.00013). There was no significant difference between the groups in the proportion of patients treated with stents (P = 0.78). The complete occlusion rates (RS1) immediately after treatment were 20% and 60%, showing a significant difference (P = 0.029). There were no perioperative complications in either group. In the conventional group, there were three cases of recurrence at the 6-month follow-up.

508 Tomotaka Ohshima et al. Table 1 Baseline characteristics of aneurysms. Conventional group Hemispheric group P value Number of aneurysm 20 10 Age (years) 62.8 ± 9.8 69.7 ± 9.3 0.17 Female 14 (70%) 6 (60%) 0.58 Ruptured 5 4 0.39 mean dome/neck ratio 1.87 ± 0.3 1.95 ± 0.5 0.59 Mean maximum aneurysmal diameter (mm) 11.43 ± 3.5 12.09 ± 3.6 0.72 Location: number ACoA 3 0 0.20 ICA 9 5 0.80 PCoA 3 2 0.73 MCA 1 1 0.61 BA 2 2 0.45 Others 1 0 0.47 ACoA, anterior communicating artery; BA, basilar artery; ICA, internal carotid artery; MCA, middle cerebral artery; PCoA, posterior communicating artery. Table 2 Comparison of relevant results between the conventional and hemispheric groups. Conventional group Hemispheric group P value n = 20 n = 10 Mean packing ratio (VER) (%) 31.1 ± 3.6 42.3 ± 7.4 0.00013 Stent assist 7 3 0.78 Balloon assist 4 0 0.12 Double catheter 9 0 0.010 Initial occlusion grade RS 1 4 (20%) 6 (60%) 0.029 RS 2 8 (40%) 2 (20%) 0.27 RS 3 8 (40%) 2 (20%) 0.27 Perioperative complication 0 0 1.00 Number of recurrence at 6-month 3 0 0.20 RS, Raymond score (RS 1 indicates complete obliteration; RS 2 indicates neck remnant without contrast filling of the aneurysmal sac; RS 3 indicates contrast filling of the aneurysmal sac); VER, volume embolization ratio. Representative case A 64-year-old woman was incidentally found to have a basilar apex aneurysm on brain MRI, and was referred to our hospital. Cerebral angiography showed an aneurysm (height 8.6 mm, length 8.3 mm, width 7.0 mm) at the apex of the basilar artery (Fig. 2A). Clopidgrel 75 mg and aspirin 100 mg were administered from 2 weeks before coil embolization. Under local anesthesia, a 6Fr Cerulean catheter DD6 115 cm (Medikit, Tokyo, Japan) was inserted as a guiding catheter into the right vertebral artery through the right radial artery. A Prowler SP microcatheter was navigated into the left posterior cerebral artery for stent delivery using a

Hemispheric divided coiling 509 Fig. 2 (A) Preoperative digital subtraction angiography showing a basilar apex aneurysm. (B) X-ray image showing deployed stent and a frame. (C) The distal hemisphere is embolized before the proximal hemisphere. (D) X-ray image showing the final configuration of the embolized aneurysm. (E) Postoperative digital subtraction angiography showing complete occlusion. (F) Skull X-ray image at 12-month follow-up reveals no coil compaction. CHIKAI 14 microguidewire (Asahi Intecc, Aichi, Japan). A Headway 17 straight microcatheter (Terumo, Tokyo, Japan) was guided into the aneurysm using the CHIKAI 14 microguidewire. After a frame was made using Cashmere 8 200 mm (Cordis, Johnson & Johnson, Fremont, CA, USA), an Enterprise 2 VRD 4.0 23 mm (Cordis) was deployed from the left posterior cerebral artery to the basilar artery (Fig. 2B). A Cashmere 4 80 mm was inserted into the aneurysm as the second coil. Then, the upper hemisphere of the aneurysm was embolized using four Target 360 coils (Stryker Neurovascular, Kalamazoo, MI, USA) and two Deltaplush coils (Cordis) (Fig. 2C). As the Headway microcatheter was kicked down into the lower hemisphere, a Cashmere 3 60 mm was deployed. In succession, three VFC coils (Terumo), two Deltapaq coils (Cordis), and four Deltaplush coils were inserted (Fig. 2D). Complete occlusion was achieved (Fig. 2E). The volume embolization ratio was calculated as 44.4%. The postoperative course was favorable, and the patient was discharged 5 days after coil embolization. Administration of aspirin was discontinued 1 month after treatment, and clopidgrel was continued. There has been no recurrence during the 12-month postoperative follow-up.

510 Tomotaka Ohshima et al. DISCUSSION The hemispheric divided coiling technique enabled a higher coil-packing attenuation in middleand large-sized aneurysms than that achieved by conventional techniques, possibly accounting for the significantly lower angiographic recurrence rate. Advantages of the hemispheric divided coiling technique The main advantages of this technique compared with the conventional onion skin or Russian doll-like coil insertion are the following: (1) The intra-aneurysmal microcatheter does not tend to be kicked back unexpectedly during coil insertion in the distal hemisphere. When we embolize ruptured aneurysms with a bleb, complete hemostasis can be achieved immediately with stable behavior of the microcatheter. (2) The framing coil can be stabilized with the distal hemispheric coils. In the conventional technique, the second or third coil tends to break the framing coil around the aneurysmal neck (Fig. 3). Our technique prevents the herniation of the framing coil into the parent artery. (3) Because the embolization begins from the aneurysmal fundus with relatively small-sized coils, coil-free dead space is not likely to remain. (4) Because the aneurysmal neck is not so dense with coils until the final stage, the positioning of the microcatheter can change easily. In particular, the trans-cell approach during the stent assist coiling is very effective (Fig. 4). We can navigate the microcatheter into the residual coil-free space wherever we want. Former hemispheric coils can prevent to penetrate the microcatheter which is likely to jump-in through the stent strut into the aneurysm. (5) As a result of these advantages, a higher volume embolization ratio can be achieved. Comparison with other adjunctive and innovative techniques A flow-diverting stent is one of the optional treatments for challenging intracranial aneurysms, including large and giant aneurysms. However, the rates of permanent morbidity and mortality with this treatment were reported to be 5.6% to 10.8%. 6, 7) Moreover, placement of flow-diverting stents for posterior circulation aneurysms resulted in a higher rate of ischemia in patients due Fig. 3 Schematic drawing of the conventional coiling technique. (A) After a frame has been made by the usual technique, the microcatheter is set around the center of the aneurysm. (B) When the second coil is inserted, one loop of the first coil unexpectedly protrudes towards the parent artery (arrow). (C) Because the movement of the tip of the microcatheter is large, it often kicks out. It is hard to navigate into the aneurysm again, because the coil density around the aneurysmal neck is already high.

Hemispheric divided coiling 511 Fig. 4 Schematic drawing of stent-assisted coil embolization with the conventional and hemispheric dividing techniques. (A) After a frame has been prepared by the usual technique, the microcatheter is set around the center of the aneurysm. (B) With the conventional technique, the tip of the microcatheter is likely to move the entire aneurysm during the second or third coil insertion. (C) Once the microcatheter is kicked out, it is difficult to navigate into the aneurysm again. (D) With the hemispheric dividing technique, the tip of the microcatheter remains. (E) The trans-cell approach can be accepted wherever appropriate. to perforator occlusion. 8) Therefore, a more effective strategy is required, particularly for large and giant posterior circulation aneurysms. Miyachi et al. reported the effectiveness of the one and a half round microcatheterization technique for stent-assisted coil embolization of large and giant intracranial aneurysms. 9) In this technique, a microcatheter is deeply inserted along the aneurysmal wall and withdrawn stepwise to result in homogeneous coil packing. We used this technique for several patients in our conventional group. In our experience, unexpected catheter kick-out often occurred when the loop of the microcatheter suddenly became small during coil insertion. We struggled to insert the microcatheter into the aneurysm again with the trans-cell approach, because the area around the aneurysmal neck was densely packed with coils. In the hemispheric group, the aneurysmal neck was not so dense with coils until the final stage; therefore, the microcatheter could be delivered easily with the trans-cell approach. Moreover, the straight microcatheter is more controllable and enables better visualization of the second marker than the extremely curved microcatheter. Ohta et al. reported a maze-making and solving technique that can achieve high coil-packing attenuation. 10) This technique is relatively complicated because it requires two microcatheters for coil delivery, one balloon catheter, and one microcatheter for stent placement. After the aneurysms are filled with larger-diameter coils, the coil dead spaces are filled in a stepwise fashion. This technique also uses the one and a half round microcatheterization technique. Although it is similar to our technique at the point of the piece-meal coil filling, we believe that simple manipulation with a straight microcatheter is more effective for dense packing than a complicated procedure. When unexpected catheter kick-out occurs, a large coil-free space may remain and result in insufficient embolization. With our technique, the course of a microcatheter that is kicked out

512 Tomotaka Ohshima et al. can be predicted. Therefore, we can select the most suitable length and thickness of the coil for each stage of coil embolization. Our technique requires fewer coils and thus has a lower cost than the maze technique. Limitations The small number of patients enrolled in this case series may not yield sufficient conclusions for estimation of long-term results. However, the homogeneous and higher coil-packing attenuation with the hemispheric divided coiling technique may help surgeons to avoid delayed recanalization of aneurysms. In this case series, there were no giant intracranial aneurysms. Giant aneurysms may require to be divided into three or more sections depending on the individual size and shape. CONCLUSIONS The hemispheric divided coiling technique achieved a high volume embolization ratio for middle- and large-sized intracranial aneurysms, with a low recurrence rate. With our technique, complicated aneurysms can be altered to the most preferred shape of aneurysm, which we are confident about, step by step. Studies of larger numbers of cases will be needed to confirm these initial findings and assess the efficacy of the technique. ACKNOWLEDGEMENTS The authors have no personal financial or institutional interest in any of the drugs, materials, or devices in the article. REFERENCES 1) Sluzewski M, van Rooij WJ, Slob MJ, Bescos JO, Slump CH, Wijnalda D. Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils. Radiology, 2004; 231: 653 658. 2) Leng B, Zheng Y, Ren J, Xu Q, Tian Y, Xu F. Endovascular treatment of intracranial aneurysms with detachable coils: correlation between aneurysm volume, packing, and angiographic recurrence. J Neurointerv Surg, 2014; 6: 595 599. 3) McDougall CG, Johnston SC, Gholkar A, Barnwell SL, Vazquez Suarez JC, Masso Romero J, et al. Bioactive vs. bare platinum coils in the treatment of intracranial aneurysms: the MAPS (Matrix and Platinum Science) trial. AJNR Am J Neuroradiol, 2014; 35: 935 942. 4) Shapiro M, Becske T, Sahlein D, Babb J, Nelson PK. Stent-supported aneurysm coiling: a literature survey of treatment and follow-up. AJNR Am J Neuroradiol, 2012; 33: 159 163. 5) Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, et al. Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke, 2003; 34: 1398 1403. 6) Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, et al. Pipeline for uncoilable or failed aneurysms: results from a multicanter clinical trial. Radiology, 2013; 267: 858 868. 7) Berge J, Biondi A, Machi P, Brunel H, Pierot L, Gabrillargues J, et al. Flow-diverter Silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study. AJNR Am J Neuroradiol, 2102; 33: 1150 1155. 8) Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke, 2013; 44: 442 447. 9) Miyachi S, Matsubara N, Izumi T, Asai T, Yamanouchi T, Ota K, et al. The one and a half round microcatheterization technique for stent-assisted coil embolization of intracranial aneurysm: technical case series. J Neurointervent Surg, 2014; 6: 357 362.

Hemispheric divided coiling 513 10) Ohta T, Nakahara I, Ishibashi R, Matsumoto S, Gomi M, Miyata H, et al. The maze-making and solving technique for coil embolization of large and giant aneurysms. AJNR Am J Neuroradiol, 2015; 36: 744 750.