Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom

Similar documents
Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Computed tomography Acceptance testing and dose measurements

Assessment of effective dose in paediatric CT examinations

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Multislice CT versus cone beam CT: dosimetric and image quality comparision.

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Accounting for Imaging Dose

Radiation Dose To Pediatric Patients in Computed Tomography in Sudan

Measurements of Air Kerma Index in Computed Tomography: A comparison among methodologies

Conventional and spiral CT dose indices in Yazd general hospitals, Iran

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

A multicentric study on patient dose in multislice CT

Survey of patients CT radiation dose in Jiangsu Province

Patient dose in routine X-ray examinations in Yazd state

Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)

Introduction and Background

Dosimetric Consideration in Diagnostic Radiology

Adopting DAP as a dose metric in CT

Why is CT Dose of Interest?

Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng

CT Radiation Risks and Dose Reduction

Regional diagnostic reference levels and collective effective doses from CT scanners in India

Thoracic examinations with 16, 64, 128 and 256 slices CT: comparison of exposure doses measured with an anthropomorphic phantom and TLD dosimeters

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

A more accurate method to estimate patient dose during body CT examinations with tube current modulation

Managing Radiation Risk in Pediatric CT Imaging

Patient dose assessment of CT perfusion scanning at the RSCH

CT Dose Reduction in Pediatric Patients

An Assessment of Organ and Effective Dose of Patients who Undertake CT Examinations in two Teaching Hospitals of Mashhad&Isfahan

Medical Physics and Informatics Original Research

Doses from Cervical Spine Computed Tomography (CT) examinations in the UK. John Holroyd and Sue Edyvean

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

A comparison of radiation doses from modern multi-slice Computed Tomography angiography and conventional diagnostic Angiography:

Radiochromic film dosimetry in water phantoms

Prepublication Requirements

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Skyscan 1076 in vivo scanning: X-ray dosimetry

CT Dose Estimation. John M. Boone, Ph.D., FAAPM, FSBI, FACR Professor and Vice Chair of Radiology. University of California Davis Medical Center

CT Quality Control Manual FAQs

Article. Reference. Comparison of organ doses and image quality between CT and flat panel XperCT scans in wrist and inner ear examinations

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

Optimizing radiation dose by varying age at pediatric temporal bone CT

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

State of the art and future development for standardized estimation of organ doses in CT

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

FDG-18 PET/CT - radiation dose and dose-reduction strategy

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Calculation of Effective Doses for Radiotherapy Cone-Beam CT and Nuclear Medicine Hawkeye CT Laura Sawyer

Combined Anatomical and Functional Imaging with Revolution * CT

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

ABSTRACT. Objectives: To investigate the radiation dose received by patients undergoing routine plain x-ray

Applications in brachytherapy

A Standardised Approach to Optimisation

National Cancer Institute

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Chief Radiographer TEI Clinical Associate 2016

Bone Densitometry Radiation dose: what you need to know

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Use of Monte Carlo Simulation Software for Calculating Effective dose in Cone Beam Computed Tomography

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Dianna Cody, PhD, DABR, FAAPM Professor & Clinical Operations Director Imaging Physics U.T. M.D. Anderson Cancer Center Houston, TX

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

Bureau of Laboratory Quality Standards

Ultralow Dose Chest CT with MBIR

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Estimating Patient Radiation Dose from Computed Tomography

Computed tomography of the head: An experimental study to investigate the effectiveness of lead shielding during three scanning protocols

Radiologic Units: What You Need to Know

Radiation Dose Estimations to the Thorax Using Organ-Based Dose Modulation

X-Ray & CT Physics / Clinical CT

Radiation Dose Reduction Strategies in Coronary CT Angiography

Prof. Dr. Doğan BOR Ankara University Institute of Nuclear Science

Collateral Exposure: The Additional Dose From Radiation Treatment

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

EFFECTIVENESS OF PROTECTIVE PATIENT EQUIPMENT FOR CT: AN ANTHROPOMORPHIC PHANTOM STUDY Barbara Ott 1, *, Anja Stüssi 2 and Roberto Mini 1

Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range

Radiation dose optimization in CT planning of corrective scoliosis surgery. A phantom study.

Patient / Organ Dose in CT

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Quanitative and qualitative analysis of Image Quality and Imaging Dose of KV CBCT from XVI Elekta Linac.

CT Dosimetry in the Clinical Environment: Methods and Analysis

EFFECTIVE DOSE ESTIMATION AND CANCER RISK ASSESSMENT DUE TO SOME SELECTED CT EXAMINATIONS AT SWEDEN GHANA MEDICAL CENTRE (SGMC)

A Snapshot on Nuclear Cardiac Imaging

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Managing Patient Dose in Computed Tomography (CT)

An Update of VirtualDose Software Used for Assessing Patient Organ Doses from CT Examinations

Estimated Radiation Dose Associated With Low-Dose Chest CT of Average-Size Participants in the National Lung Screening Trial

Cone Beam CT Protocol Optimisation for Prostate Imaging with the Varian Radiotherapy OBI imaging system. Dr Craig Moore & Dr Tim Wood

Application of dose-area product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology

DETERMINATION OF ENTRANCE SKIN DOSE FROM DIAGNOSTIC X-RAY OF HUMAN CHEST AT FEDERAL MEDICAL CENTRE KEFFI, NIGERIA

Transcription:

Original Article Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom Seyedeh Fatemeh Seyedatashi 1, Mitra Athari 1, Ahmad Bitarafan-Rajabi 2, Hadi Hasanzadeh 3, *, Mehravar Rafati 4, Hamid Reza Pouraliakbar 5, and Ali Mohammadzadeh 5 1- Islamic Azad University, Science and Research Branch, Tehran, Iran. 2- Cardiovascular interventional research center, Department of nuclear medicine, Rajaei Cardiovascular, Medical & Research Center, Iran University of medical sciences, Tehran, Iran. 3- Cancer Research Center and Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran 4- Department of Medical Physics, Faculty of Paramedical Sciences, Kashan University of Medical Science, Kashan, Iran. 5- Rajaei Cardiovascular, Medical & Research Center, Radiology Department, Iran University of Medical sciences, Tehran, Iran. Received: 14 November 2014 Accepted: 15 January 2015 Keywords: Multidetector computed tomography, Film dosimetry, Phantoms, Imaging, Radiation dosage. ABSTRACT Purpose- The most general form to report dose in Multislice CT is the CTDI and DLP which are computed for several slices. The goal of the current study was to estimate actual doses and dose distribution during CT examinations in a head and neck anthropomorphic phantom. Methods- After construction of the head and neck phantom using natural bone and paraffin wax with NaCl as impurity, several places were considered in different sites to fill with badges of Gafchromic film. These places include brain, Parotid, Thyroid and Lens of eye. Phantom was scanned at CT Angio and Spiral protocols with 10 and 256 slice scanners. Results- Our findings showed that in 10 slice scanner, selected organ doses were in the range of 0.09-23.1 msv while in the 256 slice scanner, it was in the range of 0.14-18.01 msv. The CT Angio protocol has a higher organ dose at all. Conclusion- In CT Angio protocol, organ dose (except for the lens of eye) is lower in 10 slice compared to 256 slice CT; the brain dose in both protocols has no difference statistically. In the spiral protocol, the dose in 256 slice scanner is lower than the 10 slice scanner which might be due to higher number of detector arrays in 256 slice scanner.thyroid dose is mainly due to scattered radiation and because of strict beam collimation; it has a small value in all protocols. 1. Introduction X-rays in medical imaging modalitieshas the greatest man-made source of radiation to the population which has significantly increased the cumulative exposure to ionizing radiation; from 15% of the total annual exposure of the population in the United States from all * Corresponding Author: Hadi Hasanzadeh, PhD Semnan University of Medical Sciences, Semnan, Iran. Tel: (+98) 2333354171-525/ Fax: (+98) 2333448999 E-mail: Hasanzadeh.h@semums.ac.ir sourcesin 1987 to about 50% in 2006 [1-3]. Recently, the number of CT examinations has been raised significantly due to the wide-spread use of multislice CT scanners [4, 5]. Performing a detailed dose measurement is important to keep radiation doses during CT examinations as low as reasonably achievable is of great importance. 31

Seyedeh Fatemeh Seyedatashi et al. Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom March 2015, Volume 2, Issue 1 There are several ways to express dose in CT such as CTDI, CTDIvol and DLP which measurements are based on ionization chambers [6-9]. A better way of estimating doses to patients undergoing CT examinations is to directly measure organ dosesor to perform computer simulations in anthropomorphic phantoms [10]. There exist several candidates to measure dose such as TLDs, gels and films [11-13]. Film has been used for dosimetric measurements for decades with the advantage of its high spatial resolution. Gafchromic film has a spatial resolution on the order of 25 μm [13-16], a high sensitivity and reasonable uniformity. The purpose of this study was to assess patient s radiation exposure in several standard protocols in MSCT. To do so, a 2D film dosimetry was applied for dose measurements using XR-QA radiochromic film MSCT examinations carried out on anthropomorphic head phantom. Performing a detailed dose measurement is important to keep radiation doses during CT examinations as low as reasonably achievable. 2. Materials and Methods 2.1. Phantom Natural human skull and paraffin wax with different amounts of NaCl as impurity was used for bone, soft tissue and fat, respectively. Two hollow plastic tubes were placed to consider trachea and esophagus and a hollow plastic box was placed to consider the mouth cavity. Two cylinders were considered vertically and horizontally from the upper limit of skull downwards and from left parotid to right parotid on the base of skull to place films in order to estimate total brain dose (arrows in Figure 1). The left and right extremes of the later were used to estimate parotid dose. Besides, two cylinders were considered at side lobes of thyroid in order to place films vertically and measure thyroid dose. Radiation dose to eye was measured at the surface in place of each eye. )a) (b( Figure 1. (a) lateral and (b) AP radiographs of the head & Neck phantom. 2.2. Calibration of Dosimeters To obtain calibration curve, films were cut into multiple pieces; divided into 7 groups each consisting 3 pieces, deliver a known dose which was measured using a solid state real-time dose monitor device (Pehamed, Germany) in the range of 0-21 mgy to each batch. The following equation was used to obtain the net optical density (netod): netod=od exp -OD unexp = log 10 [(PV unexp -PV bg )/(PV exp -PV bg )] Where PVunexp refers to the pixel value of blank film, PVexp refers to pixel value of exposed film, and 32

PVbg refers to pixel value of opaque black cardboard. Reading the film with scanner was performed after a certain time. Some correction is needed for scanner artifacts such as scanner fluctuation and light scattering effect. After obtaining optical density and dose values, a calibration curve with certain parameters and equation was obtained. 2.3. Imaging Protocols Two common imaging protocols as spiral CT and CT Angio were conducted on the phantom with two existing CT machines (Siemens Somatom definition flash 256 slice and Somatom sensation 10 slice, Germany, healthcare). It is notable that imaging condition was identical to an adult patient with a similar head size (kv p =120). 2.4. Dosimetric Measurements Organ doses were measured using calibrated radiochromic films embedded in the phantom. The exposed radiochromic film was read-out using a flatbed scanner in reflection mode which red channel was extracted in Matlab (version 7.8, Mathworks, USA) to convert to dose using calibration equation described earlier. In order to increase reproducibility and reduce temporal noise, each measurement was repeated 3 times. 3. Results Figure 3 shows the calibration curve for Gafchromic films used in this study with its calibration equation and correlation coefficient. 25 20 Dose (mgy) = 95.764(NOD) 2 + 53.896(NOD) + 0.008 R 2 = 0.984 Dose (mgy) 15 10 5 0 0 0.05 0.1 0.15 0.2 0.25 0.3 NOD Figure 3. The calibration curve for films used with the calibration equation. (a) (b) Figure 2. The head phantom placed at the (a) 256 slice and (b) 10 slice CT. In this graph, the horizontal axis shows the net optical density (NOD) as described before and the vertical axis shows dose values in mgy. Because we used 120 kv p for imaging the head phantom, the calibration was performed at this condition, too. Table 1 shows the absorbed dose to brain, left and right parotid (as mean depth dose), lens of eye (as mean surface dose) and thyroid (as mean depth dose). It is notable that to measure brain dose, two perpendicular directions was selected and by inserting appropriate applicators to insert films, the average brain dose was estimated. Besides, using similar applicators, parotid and thyroid depth dose at both sides was measured. The obtained results for both protocols in each system with the CTDI vol are presented in Table 1. 33

Seyedeh Fatemeh Seyedatashi et al. Dosimetric Evaluation of Multislice CT Using Anthropomorphic Head Phantom March 2015, Volume 2, Issue 1 Table 1. Mean organ dose (SD) in mgy and CTDI VOL at CT Angio and spiral protocols in 10 and 256 slice CT systems. Protocol Parotid Thyroid Brain Lens of eye CTDI vol 10 slice 256 slice CT Angio 2.15 (0.04) 0.09 (0.01) 8.41 (0.03) 7.53 (0.17) 23.32 Spiral 7.06 (0.02) 0.77 (0.14) 23.11 (0.47) 23.04 (0.06) 54.43 CT Angio 7.16 (0.001) 0.14 (0.05) 8.99 (0.1) 5.32 (0.5) 28.84 Spiral 6.01 (0.12) 0.68 (0.08) 18.01 (0.15) 17.15 (0.01) 50.92 4. Discussion There are many variables within each CT examination procedure that influence patient dose, in particular, slice thickness and the tube current time product (mas). Slice thickness and mas are linked through image noise [4]. One method to report dose in computed tomography is to compute CTDI and DLP for a single slice or several slices in a reference phantom. These parameters have the merits of simple calculation, considering scan parameters such as pitch factor, detector rotation time and beam filtration; but they do not consider patient size and tissue types and mass which disturbs dose distribution in patient s body. Anthropomorphic phantoms with appropriate tissue substitutes allow simulating clinical situations more accurately. Films are capable to provide continuous dose distribution at each site they embedded in the phantom. In order to measure doses in clinical situations, standard protocols for a patient with same size as the phantom without any modification was used. As it is observed from Table 1, in CT Angio protocol organ dose (except for the lens of eye) is lower in 10 slice CT compared to 256 slice CT; the brain dose in both protocols has no difference statistically. This agrees with the results of NRPB survey which compared 4 slice scanners with scanners capable to obtain 8 or more slices simultaneously [17]. Yates et al compared SSCT with MSCT scanners and found that on average the mean effective dose levels for MSCT were about 35% higher than SSCT [18]. This significant difference might be due to different protocols used in two scanners. In the case of eye, the difference could be due to surface measurements and its position relative to slices and also beam collimation. In the spiral protocol, it is observed that the dose in 256 slice scanner is lower than the 10 slice scanner. This is due to higher number of detector arrays in 256 slice scanner which leads to lower organ doses and it is possible to perform a scan with the same quality and lower dose levels. In the case of thyroid, received dose is mainly due to scattered radiation and because of strict collimation of radiation, has a small value in all protocols. In some studies, the effective dose was estimated from DLP and EDLP values without any direct measurement of organ dose using TLD or any other clinical dosimeters [17, 19]. Among the studies on organ dose in CT examination on phantoms, our study agrees with study of Cohnen et al [20] which used TLD and anthropomorphic phantom but has some differences with findings of Feng et al [21] study which is due to considering pediatric phantom and some differences in scanners. It is notable that the risk of inducing a fatal cancer is estimated to be about 0.05/Sv which equates to a fatal cancer risk of 1 in 20,000 for every 1 msv [22] for low doses, such as in diagnostic CT. So, estimation of dose levels in CT helps to estimate public dose and increase in the probability of cancer induction. In conclusion, according to different studies and the radiation carcinogenesis, it is necessary to estimate organ effective dose in different protocols in newer systems to assure that dose levels and indeed public dose are being kept low and no increase in the risk of cancer induction. It is suggested to perform such study for other imaging protocols and systems. Acknowledgment This work was made possible with kind collaboration of department of radiology of Rajaei cardiovascular, Medical & Research Center. 34

References 1- Amis ES, Jr., Butler PF. ACR white paper on radiation dose in medicine: three years later. Journal of the American College of Radiology. vol. 7, pp. 865-870, 2010. 2- NCRP. Ionizing radiation exposure of the population of the United States. Report 93, 1987. 3- NCRP. Ionizing radiation exposure of the population of the United States. Report 103, 2009. 4- McCann C, Alasti H. Comparative evaluation of image quality from three CT simulation scanners. Journal of applied clinical medical physics. vol. 5, pp. 55-70, 2004. 5- Nakae Y, Oda M, Minamoto T. [Patient dose simulation in X-ray CT using a radiation treatment-planning system]. Nihon Hoshasen Gijutsu Gakkai Zasshi. vol. 5, pp. 935-943, 2003. 6- EUR 16262 EN: European guidelines on quality criteria for computed tomography. European Commission Report, 1999. 7- FDA. Performance standards for ionizing radiation emitting products. Sec 1020.33, Computed Tomography (CT) equipment. Food and Drug Administration. Bureau of Radiological Health, 1980. 8- Garvey CJ, Hanlon R. Computed tomography in clinical practice. British medical journal. vol. 324, pp. 1077-1080, 2002. 9- Siemens AG MS. Siemens Sensation 64. Available from: www.siemens.com/medical. 10- Brenner DJ. Is it time to retire the CTDI for CT quality assurance and dose optimization? Medical Physics. vol. 32, pp. 3225-3226, 2005. 11- Attix FH. Introduction to radiological physics and radiation dosimetry. New York: Wiley; 1986. 12- McKinlay AF. Thermoluminescence dosimetry. Bristol: Adam Hilger in collaboration with the Hospital Physicists Association; 1981. 13- Cohnen M, Poll L, Puttmann C, Ewen K, Modder U. Radiation exposure in multi-slice CT of the heart. ROFO FORTSCHR GEB RONTGENSTR NUKLEARMED. vol. 173, pp. 295-299, 2001. 14- Ebert MA, Asad AH, Siddiqui SA. Suitability of radiochromic films for dosimetry of very-low energy X-rays. Journal of applied clinical medical physics. vol. 10, pp. 2957, 2009. 15- Chiu-Tsao ST, Ho Y, Shankar R, Wang L, Harrison LB. Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies. Medical Physics. vol. 32, pp. 3350-3354, 2005. 16- Rampado O, Garelli E, Deagostini S, Ropolo R. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams. Physics in Medicine and Biology. vol. 51, pp. 2871-2881, 2006. 17- Shrimpton PC, Hillier MC, Lewis MA, Dunn M. NRPB - W67 Doses from Computed Tomography (CT) Examinations in the UK - 2003 Review. NRPB. 2005. 18- Yates SJ, Pike LC, Goldstone KE. Effect of multislice scanners on patient dose from routine CT examinations in East Anglia. British Journal of Radiology. vol. 77, pp. 472-478, 2004. 19- Bongartz G, Golding S, Jurik A, Leonardi M. European guidlines on quality critria for CT. EUR 16262 EN, 1999. 20- Cohnen M, Poll LJ, Puettmann C, Ewen K, Saleh A, Modder U. Effective doses in standard protocols for multi-slice CT scanning. European Radiology. vol. 13, pp. 1148-1153, 2003. 21- Feng ST, Law MW, Huang B, Ng S, Li ZP, Meng QF, et al. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: a phantom study. European Journal of Radiology. vol. 76, pp. e19-23, 2010. 22- ICRP. Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. vol. 21, pp. 1-3, 1991. 35