BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.

Similar documents
ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Neuro-Audio Version 2010

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

III. Comprehensive. Efficient. Auditory EP Testing

Eclipse Evoked Potential System. 10 reasons to choose

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

UPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS

SLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;

James W. Hall III, Ph.D.

NEURO-AUDIO. Auditory EP (ABR, ASSR, ECochG), PTA and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Contents. Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface

Audiology Core Competencies Worksheet

The following describes general use of ELIOS device

Audiological Diagnosis after Newborn Screening

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

A full product range for your every need. World leading diagnostic solutions

ABR assesses the integrity of the peripheral auditory system and auditory brainstem pathway.

AccuScreen ABR Screener

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

KANSAS GUIDELINES FOR INFANT AUDIOLOGIC ASSESSMENT

NEURO-AUDIO. Auditory EP (ABR, VEMP, ASSR, ECochG) and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

OPEN ACCESS GUIDE TO AUDIOLOGY AND HEARING AIDS FOR OTOLARYNGOLOGISTS

the truly automated all-in-one hearing screener

Evoked Potenital Reading Session: BAEPs

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Speech Therapists and Audiologists 2007

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

Evoked Potenital Reading Session: BAEPs

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

AUTOMATED AUDITORY BRAINSTEM RESPONSE INFORMATION AND GUIDELINES FOR SCREENING HEARING IN BABIES

Quick Guide - eabr with Eclipse

General Catalogue. Product Line for Hearing Screening & Diagnostics

User Manual. Neuro-Audio.NET UM ( )

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

(Otoacoustic Emissions and Automated ABR)

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

Hearing Screening, Diagnostics and Intervention

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

AUDITORY STEADY STATE RESPONSE (ASSR)

The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Doctor of Audiology Post-Professional Program. Online Education for Practicing Audiologists. AuD. Curriculum Guide

EASY. Comprehensive EP testing

EMG/EP Measuring System MEB-9400K

Official CPT Description

Electrophysiologic Assesment II ASLP Spring, 2018

A full product range for your every need. World leading diagnostic solutions

by Maico Diagnostics

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

General Catalogue. Product Line for Hearing Screening & Diagnostics

Provisional guidelines for using Auditory Steady State Responses (ASSR) in babies. July 2009

Early Hearing Detection & Intervention Programs, Pediatricians, Audiologists & School Nurses use AuDX Screeners

Additional Information Eclipse

Recommended Procedure Cochlear Microphonic Testing

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Bio-logic AuDX PRO FLEX Quick start Quick start guide

EPH - International Journal of Medical and Health Science

PURPOSE OF THIS PRESENTATION GUIDELINES DEVELOPMENT CONFERENCE GUIDELINES DEVELOPMENT CONFERENCE: FACULTY GUIDELINES DEVELOPMENT CONFERENCE: OUTCOMES

SRINIVAS (IJHSP), ISSN: 1, 2, PUBLICATION

TEMPLATES FOR COMPREHENSIVE BALANCE EVALUATION REPORTS. David Domoracki PhD Cleveland Louis Stokes VA Medical Center

Thresholds of Tone Burst Auditory Brainstem Responses for Infants and Young Children with Normal Hearing in Taiwan

General Catalogue. Hearing Screening & Diagnostics

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Coding with Confidence:

Auditory Steady-State Response (ASSR): A Beginner's Guide by Douglas L. Beck, AuD, David P. Speidel, MS, Michelle Petrak, PhD

Additional Information Eclipse

2) What is the most robust distortion product evoked with DPOAEs? A. F1 B. F2 C. 2F1-F2 D. 2F2 F1

Name: Bahram Jalaei. Department of Audiology School of Rehabilitation Sciences Iran University of Medical Sciences Tehran, Iran

General Catalogue. Hearing Screening & Diagnostics

VEMP: Vestibular Evoked Myogenic Potential

Current Perspectives in Balance Assessment. Topics for Today. How are we doing? 3/5/2010. Scott K. Griffiths, Ph.D. March 26, 2010

Audiology (Clinical Applications)

first described by Starr 1996 as a subgroup of patients with

Using Electrocochleography to Assess the Afferent Pathway in the Cochlea. Senior Thesis

General Catalogue. Product Line for Hearing Screening & Diagnostics

AC40. The true clinical. hybrid

NEURODIAGNOSTIC TECHNOLOGIST SPECIALTY

Bio-logic AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide

The registration testing for audiometric device in CFDA

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

Simultaneous multiple stimulation of the auditory steadystate response (ASSR)

DOWNLOAD OR READ : VESTIBULAR EVOKED MYOGENIC POTENTIAL ITS BASICS AND CLINICAL APPLICATIONS PDF EBOOK EPUB MOBI

EDUCATION University of Texas at Dallas-Dallas, Texas Doctor of Philosophy-Audiology ( )

Operation Manual. The Eclipse Platform EP15, EP25, TEOAE25, DPOAE20, ABRIS, ASSR. Introduction. The Eclipse Hardware and Software Installation

VESTIBULAR FUNCTION TESTING

Transcription:

BIO-LOGIC NAVIGATOR PRO TRUSTED TECHNOLOGY. RELIABLE RESULTS. www.natus.com

THE BIO-LOGIC NAVIGATOR PRO SYSTEM DELIVERS A RELIABLE AND ACCURATE DIAGNOSTIC EVOKED POTENTIAL TESTING PLATFORM WITH AN ADAPTABLE DESIGN FOR SATISFYING CURRENT AND FUTURE CLINICAL NEEDS.

THE BIO-LOGIC NAVIGATOR PRO AEP SYSTEM IS FLEXIBLE, PORTABLE AND ADAPTABLE, PROVIDING RESULTS YOU CAN TRUST. DESIGNED BY AUDIOLOGISTS TO CONTINUOUSLY ADAPT TO EVOLVING CLINICIAN AND PATIENT NEEDS The Bio-logic Navigator Pro system offers a full range of AEP functionality. Portable and light weight Multiple waveform display configurations Active data analysis during collection Continuous EEG display Customizable protocols and reports Windows 7 compatible Multiple protocols available or create your own Dual, scrolling displays for unlimited waveforms FULL AEP FUNCTIONALITY INCLUDES: Click evoked ABR Tone burst ABR Electocochleography (ECochG)* Middle and late latency response (MLR, ALR) P300 Electrical ABR (EABR)* Vestibular Evoked Myogenic Potential (VEMP)** *required cables available at additional cost **not available in the U.S. Screening ABR Screening OAE Diagnostic DPOAE Diagnostic TEOAE Input/Output OAE functions MASTER II Auditory Steady State Response Electroneuronography (facial nerve testing) Vestibular Evoked Myogenic Potential Test**

THE BIO-LOGIC NAVIGATOR PRO AEP SYSTEM DESIGNED BY AUDIOLOGISTS FOR AUDIOLOGISTS. One small package meeting your needs... ADVANCED DATA COLLECTION AND ANALYSIS FEATURES Automatic electrode switching eliminating the need to manually switch electrodes during testing Residual noise calculation and Fsp optimizing response detection Waveforms saved automatically no lost data Flexible data analysis mark and compare waveforms during collection Collection protocols select from several built in protocols with commonly used parameters or easily create your own Quantifiable reproducibility mathematically correlate waveforms to ensure reliability GraphMaster create charts to compare latencies to published age referenced normative data FLEXIBLE REPORT SOFTWARE Save reports as pdf file allowing for simple transfer to the patient s electronic medical record (EMR) Customizable report templates creating professional reports to meet the needs of your practice Comprehensive patient database allowing for creation of optional folders to organize patient records Auditory Evoked Potentials Page 1 San Diego Medical Center Department of Audiology 500 Harbor Drive San Diego, CA 92101 619-555-5000 Patient: ID#: 2 channel, AC Click Adult Neuro Gender: Birth date: 1/1/2000 Test Date: 3/23/2011 10:54:48 AM Physician: A. B. Aare, MD Tested by: Mary Ormson, AuD History: This patient was referred by Dr. Aare for a neurodiagnostic ABR evaluation. He was previously seen in our office for a full audiologic workup, including pure tone audiometry and impedance testing. All results were within normal limits, consistent with normal hearing thresholds and normal middle ear compliance and pressure. Ipsilateral and contralateral acoustic reflexes were within normal limits in each ear, with no evidence of reflex decay. Medical history is significant for high blood pressure for which the patient is taking medication. He reports difficulty with balance, which was first noticed approximately one month after he bagan taking his blood pressure medication. There is no history of falls. He is able to work at his present job with no accommodations. He is able to drive and to complete most activities in his home without difficulty. Page 2 Results and Recommendations: Patient: ID#: Tested by: 2 channel, AC Click Adult Neuro Mary Ormson, AuD Gender: Birth date: 1/1/2000 Test Date: 3/23/2011 10:54:48 AM Physician: A. B. Aare, MD The ABR was recorded using a 4 electrode array and two channel recording to measure ipsilateral and contralateral responses. An 80dBnHL, 10.9 click per second rarefaction stimulus was presented to each ear individually through standard insert earphones. The absolute and interpeak latencies are within 2 standard deviations of the age-referenced normal values, bilaterally. Waveform morphology and reproducibility is excellent. There are no significant interaural latency differences noted. Test results are consistent with normal brainstem conduction and no retrocochlear pathology for each ear. Recommendations include returning to the referring physician for continued followup. Further evaluation to address the complaints of imbalance might include CDP with the NeuroCom SMART EquiTest to evaluate functional postural control, as well as VNG to assess the possibility of peripheral vestibular hypofunction. Latencies (ms) Label Index I II III IV V Interlatencies (ms) Label Index I-III III-V I-V A1 1.57 2.86 3.82 4.99 5.57 A1 2.25 1.75 4.00 B1 1.66 2.78 3.66 4.90 5.45 B1 2.00 1.79 3.79

THE BIO-LOGIC NAVIGATOR PRO FAMILY OF PRODUCTS. AEP Standard auditory evoked potentials including ABR, ECochG, MLR, ALR, P300 and EABR Scout Full range of OAE test capability including DPOAE and TEOAE ABaer Newborn hearing screening system including ABR, DPOAE and TEOAE MASTER II Multiple Auditory Steady-State Evoked Response (ASSR) technology ENoG External SEP stimulator option supports electroneuronography VEMP* EMG rectification for Vestibular Evoked Myogenic Potential test *Not available in the U.S. Scout ABaer MASTER II ENoG VEMP

Natus Medical Incorporated www.natus.com Register for the Neonatal Care Academy at www.neonatalcareacademy.com for expanded educational courses & more 2017 Natus Medical Incorporated. All Rights Reserved. All product names appearing on this document are trademarks or registered trademarks owned, licensed to, promoted or distributed by Natus Medical Incorporated, its subsidiaries or affiliates. P/N 006568D