What is a CGM? (Continuous Glucose Monitor) The Bionic Pancreas Is Coming

Similar documents
PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS)

The In-Clinic Close Loop Experience in the US

Diabetes Management with Continuous Glucose Monitoring & Multiple Daily Injections. Aaron Michels MD

Inpatient Studies of a Kalman-Filter-Based Predictive Pump Shutoff Algorithm

Reduction in Hypoglycemia and No Increase in A1C with Threshold-Based Sensor-Augmented Pump (SAP) Insulin Suspension: ASPIRE In-Home

Diabetes Management: Current High Tech Innovations

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?

Insulin Pumps and Glucose Sensors in Diabetes Management

More Than 1 Year of Hybrid Closed Loop in Pediatrics. Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes?

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

Update on Continuous Glucose Monitoring (CGM) Technology in Diabetes. Elena Toschi, MD November 12, 2016

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)

Making the Most of Continuous Glucose Monitoring

Supplementary Appendix

Sensor-augmented pump systems provide insulin delivery

Artificial Pancreas Device Systems

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico

Diabetes through my eyes. Rick Mauseth, M.D. W.A.D.E. April 2013

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

The Impact of Accelerometer Use in Exercise-Associated Hypoglycemia Prevention in Type 1 Diabetes

Continuous Glucose Monitoring

Diabetes Management in Toddlers/Preschoolers (<6 yo)

Advances Towards the Bionic Pancreas.

Welcome to CareLink Pro

Medical Policy. MP Artificial Pancreas Device Systems

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

Artificial Pancreas Device System (APDS)

How I use the latest technology to investigate and treat a person with Type 1 Diabetes. Dr Pratik Choudhary

Report Reference Guide

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

Continuous Glucose Monitoring: Changing Diabetes Behavior in Real Time and Retrospectively

Real-Time Continuous Glucose Monitoring: From Application to Evaluation

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

When Will CGM Replace SMBG? Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida

Advances in Managing Diabetes in Youth. March 1, 2012

CGM: Continuous Glucose Monitoring Making Sense of It All AW: ANCO/GEND/1016/0117

Incorporating CGM Into Clinical Decision Making. Etie Moghissi, MD, FACE Clinical Associate Professor, David Geffen School of Medicine UCLA

The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections

King s Research Portal

The Realities of Technology in Type 1 Diabetes

Effective Health Care Program

Emerging Automated Insulin Delivery Systems

Medical Education. Personal Continuous Glucose Monitoring Protocol. Innovating for life.

CGM and Closing The Loop

Optimizing Therapy and Clinical Outcomes Using Real-Time Continuous Glucose Monitoring (AADE PRODUCT THEATRE) August 7, 2014 Orlando, FL

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

The next five years in diabetes technology: closed-loop systems

Update on Diabetes Technology

Florida Network Symposium

Future Direction of Artificial Pancreas. Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida

JDRF Perspective on Closed Loop

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018

Objectives. Glucose Monitoring Today. Tracking Glucose ISO Standards. Continuous Glucose Monitoring & Diabetes Management 3/7/2015

Paradigm/Guardian CGM Screens. CareLink Online Reports. Make Your Own Jackson Pollack. CGM by Jackson Pollack. How To Read CGM Screens/Reports

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER

Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose Monitoring

Diabetes Care 34: , 2011

Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier??

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Hybrid Closed Loop Status & Practical Challenges in Implementation

VIRTUAL PATIENTS DERIVED FROM THE

Pump and Sensor Data Interpretation. Irl B. Hirsch, MD University of Washington School of Medicine

WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION

NEWS BRIEFING Advances in Technology. moderated by: Irl Hirsch, MD University of Washington Medical Center

Clinical Value and Evidence of Continuous Glucose Monitoring

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures

CARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT CARELINK REPORTS GUIDE

Continuous Glucose Monitoring (CGM)

Technology in Diabetes Management Irl B. Hirsch, MD University of Washington

Exercise Prescription in Type 1 Diabetes

Advances in Diabetes Care Technologies

Agreement between Glucose Trends Derived from Three Simultaneously Worn Continuous Glucose Sensors

Artificial Pancreas Technologies: New Tools to Improve Diabetes Care Today and Tomorrow

DIABETES & ENDOCRINE DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid

1. What s the point of a network the case for research? 2. How to use CSII effectively

PROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY

Current Glucometers. Junior s s Glucose Log. All have advantages and disadvantages Answer 2

Insulin pump therapy. Healthy Living with Diabetes

Interpretation of Continuous Glucose Monitoring (CGM) Data

You are the parent or guardian granting consent for a minor in this study.

Evidence and Guidelines TECHNOLOGY 2016 Tina Kader, MD

Norbert Hermanns, PhD 1,2, Beatrix Schumann, MD 2, Bernhard Kulzer, PhD 1,2, and Thomas Haak, MD 1,2. Original Article

National Medical Policy

Comparing the use of SMBG vs. CGM data to Optimize Glucose Control in T2DM

Corporate Medical Policy

Making Sense of Glucose Monitoring. My Journey with Glucose Monitoring Over the Last 37 Years 8/7/2017

15 th Annual DAFNE collaborative meeting Tuesday 28 th June 2016

Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes

Dexcom Current and Future Technology Innovations. Jorge Valdes Chief Technical Officer

Advances in Diabetes Care Technologies

Transcription:

The Bionic Pancreas Is Coming Montana Diabetes Professional Conference October 23, 2014 H. Peter Chase, MD Professor of Pediatrics University of Colorado Barbara Davis Center Stanford: Bruce Buckingham, Darrell Wilson UCSB: Frank Doyle, Eyal Dassau Rensselaer Polytechnic Institute: Wayne Bequette, Hyunjin Lee, Fraser Cameron JAEB: Roy Beck, John Lum, Craig Kollman, Judy Sibayan Disclosure- Research Grant from DexCom 1 Q: What is an Artificial ( Bionic ) Pancreas? (also known as closed-loop pancreas ) Answer: An insulin pump, continuous glucose monitor (CGM) and a receiver with algorithms to regulate insulin output based on the CGM glucose values. 2 What is a CGM? (Continuous Glucose Monitor) A device that provides real-time glucose readings from a sensor embedded in skin. Reads the glucose levels every 1-5 minutes ( 10 minute delay behind blood glucose) Provides alarms for high and low glucose levels and trend information The 3rd era in diabetes management 3 1

Who Should Use a CGM? 1) Children AND parents must both want a CGM 2) Willing to wear the sensor (and carry the receiver) 3) Practices good diabetes care (4 BGs/day) 4) Good support system 5) Adequate body real estate 6) Can afford ongoing cost 4 Three Parts to All CGMs: A. Sensor B. Transmitter C. Receiver/Monitor 5 A)Sensor 6 2

B)Transmitter 7 C)Receiver or Monitor 8 What type of data will we get? 1) Real-time (Immediate) feedback Trend graphs Glucose alerts Trend arrows Barbara Davis Center 9 3

Trend Graphs Trend graphs Knowing a glucose level is 240 mg/dl may not be as important as knowing the trend. Rate of Change Arrows and Alerts Glucose rising quickly >2 (mg/dl)/min Glucose rising 1 to 2 (mg/dl)/min Stable glucose -1 to 1 (mg/dl)/min Glucose falling -1 to -2 (mg/dl)/min Low glucose alert Glucose falling quickly >-2 (mg/dl)/min Second type of data: (Retrospective, must download) 2) Retrospective Data A.Sensor overlays B.Charts and graphs C.Data Tables 12 4

A) Sensor Overlay Tracings of Individual Days 13 B) Charts and graphs BG, Carbs, Bolus Amount and LGS 14 C) Low Glucose Suspend and Bolus History 15 5

USE OF CGM RESULTS: Fine-tuning of Diabetes Management Important not to overwhelm families *** 1-2 insulin changes at a time *** Look for patterns 3 out of 4 days Can identify behavior issues: missed boluses, snacking, exercise, etc Do not make changes too often 16 WHY use CGM? 1. Prevention of high blood sugars 2. Prevention of low blood sugars 3. Minimize wide glucose fluctuations 4. Behavior Modification 5. Prevention of Complications (?) 17 Snapshot of BG levels 18 6

Continuous Glucose Monitoring 19 50% 40% Hyperglycemia is common, especially after meals 30% 20% Breakfast Lunch Dinner 10% 0% < 180 181-240 241-300 > 300 Barbara Davis Center Boland et al, Diabetes Care 24:1858, 2001 20 WHY USE CGM? 1. Prevention of high blood sugars 2. Prevention of low blood sugars ***most helpful with artificial pancreas*** 3. Minimize wide glucose fluctuations 4. Behavior Modification 5. Prevention of Complications (?) 21 7

INSULIN PUMP and CGM COMBINED (Sensor Augmented Pump [SAP]) Major Clinical Studies in the Past Five Years 1) JDRF: MDI or CSII Half randomized to use CGM (NEJM 359, 1464, 2008) 2) Star 3: MDI Half randomized to insulin pump (CSII) plus CGM (sensor augmented pump or SAP) (NEJM 363:311, 2010) 3) Bionic- closed loop pancreas I) Low-Glucose Suspend (LGS) II) ASPIRE: In Clinic and In-Home Studies: US III) Predicted Low Glucose Suspend 22 Use of Continuous Glucose Monitoring (CGM) With Pump or MDI JDRF-RCT (NEJM 359:1464,2008) 322 (of 451) subjects 8-69 yo on CSII or MDI 10 Centers/JAEB coordination Randomized to CGM or Control x 6 mo 23 JDRF Cohort with HbA1c 7.0% (NEJM 359:1464,2008) Primary outcome = in HbA1c @ 6 mo Found only in subjects > 25 yo (p < 0.001) CGM: 7.6 7.1, vs Control: 7.6 7.4 Secondary endpoints (CGM vs. Control group > 25 yo) i) in A1c > 10% (p = 0.0003) ii) A1c < 7.0% @ 6 mo (p = 0.005) iii) More time in 71-180 mg/dl range (p < 0.001) 24 8

Conclusions: CGM is good if it is used! 1) Use of Insulin pump + CGM (SAP) reduces HbA1c > MDI (STAR-3) 2) CGM lowers HbA1c for patients on pump or MDI if the CGM is used 6 days/week (JDRF study) 3) Next: Three studies to demonstrate reduction of hypoglycemia with bionic pancreas: i) Low Glucose Suspend (LGS) in clinic ii) LGS at home iii) Predictive Low Glucose Suspend (PLGS) (NEJM 363:311, 2010) STAR 3 was a large-scale, multicenter, randomized, controlled trial of 485 patients, ages 7 to 70 years, with T1D at 30 Centers 26 Results Over Time: 485 Patients The SAP group achieved a greater A1C reduction vs. MDI at 3 months and sustained it over 12 months A1C Reduction for SAP and MDI Groups = SAP = MDI n = 244 n = 241 Values are means ± SE. Comparisons between SAP group and MDI group are significant for each time period (P<0.001). 27 9

A1C Reduction is Correlated with Increased Sensor Use The majority of patients used sensors >60% of the time Patients who used sensors 81% of the time reduced their mean A1C by 1.2% at 1 year vs. baseline n =27 n =46 n =108 n =56 Values are the difference between the means ± SE. p=0.003 for association between sensor wear and A1C reduction at 1 year. Only 7 participants had sensor use of 20% or less, with a change in A1C of -0.43 at 1 year vs. baseline. 28 I. Hypoglycemia Prevention with Use of Low Glucose Suspend (LGS) in Sensor-Augmented Pumps (SAP) Source Patients/ Methods Results 21 youth with T1D from 3 centers in Germany 2 wks=sap 4 wks=sap with LGS Danne, T. et al., Diab. Tech. Ther. 13, 1129, 2011 Choudhary, P. et al., Diabetes Care 34, 2023, 2011 Agrawal, P. et al., J. Diab. Sci Tech. 5, 1137, 2011 31 adults with T1D in. 2 wks=sap 3 wks= SAP with LGS 935 patients 28,401 pt days/278 pts. > 3mos LGS feature in Real World SAP with LGS= 1) No SH or DKA 2) Decrease time spent (and decrease number of episodes) <70mg/dL 3) Positive device satisfaction SAP with LGS= 1) No deterioration of glucose control 2) time of nocturnal hypoglycemia in those with highest quartile of hypoglycemia at baseline 3) All subjects found LGS useful and 93%= (more secure at night) 1) Sensor glucose @ 2 hours=150±69 mg/dl 2) Significant reduction in BG values < 50 mg/dl when LGS in use (p < 0.001). Summary: in initial studies, time spent in hypoglycemia is reduced as a result of the use of the LGS feature. 29 ASPIRE: I. Randomized Trial of LGS after Exercise in Clinic 10

ASPIRE In-Clinic Study: Results Mean YSI Glucose Values by Time for LGS On and LGS Off Sessions Garg S, Brazg RL, Bailey TS, et al. Diabetes Technol Ther. 2012;14:205-209. ASPIRE In-Clinic Study: Results Duration and Severity of Hypoglycemia Duration of hypoglycemia (minutes) Nadir (mg/dl) End-Observation YSI (mg/dl) LGS On 138.5 ± 76.68 59.6 ± 5.72 91.4 ± 41.84 LGS Off 170.7 ± 75.92 57.6 ± 5.69 66.2 ± 13.48 P 0.006 0.015 <0.001 95% CI -57.7 to -7.8 0.3-3.8 12.3-38.1 Mean + SD Garg S, Brazg RL, Bailey TS, et al. Diabetes Technol Ther. 2012;14:205-209.c Threshold Suspend Control 247 patients were randomized to low glucose (threshold) suspend or control arms for a 3 month study. Age 41.6 ± 12.8 44.8 ± 13.8 % Male 38 39.7 Diabetes Duration 27.1 ± 12.5 26.7 ± 12.7 BMI, kg/m 2 27.6 ± 4.7 27.1 ± 4.3 Bergenstal RM, Klonoff DC, Garg SK et al. N Engl J Med 2013; 369: 224 232 33 11

ASPIRE In-Home Study: Reduction in Nocturnal Hypoglycemia (Bergenstal RM, Klonoff DC, Garg SK et al. N Engl J Med 2013; 369: 224 232) 38% reduction p<0.001 1547 (2035) 980 (1200) 1406 (1950) 1568 (1995) Mean AUC of Nocturnal Hypoglycemia events was 38% lower in the Threshold Suspend Group. Similar A1c values at the End of the Study Similar Benefits in Children and Young Adults 34 ASPIRE In-Home Study: Percentage of time that SG values were in the <50, 50 to <60, and 60 to <70 mg/dl ranges. Bergenstal, Klonoff, Garg et al: NEJM 2013 35 II. Hypoglycemia Prevention With Use of Predictive Low Glucose Suspend (PLGS) A) Two day admissions to CRC 1) Use of Navigator CGM 2) Increase basal rate up to 180% 3) No PLGS=85% low (BG <60mg/dL; <2.2mmol/L) 4) With PLGS=28% low Diabetes Care 2010, 33:1013-1017 36 12

II. Predictive Low Glucose Suspend (PLGS) 37 B. Initial outpatient (in-home) PLGS studies Use of MiniMed and Paradigm Real-time Revel System 21 night randomized trial with PLGS on or off (2:1) PLGS occurred on 53% of 77 intervention nights Hypoglycemia (<70mg/dL; [<3.9mmol/L]) occurred in 16% of PLGS nights versus 30% of control nights 38 System Description 39 13

C) Home Study: 2000 nights Demographics Value Age (yr) median (15-45 years) 30 (22, 39) Male / Female 21 / 24 Race White non-hispanic 42 (93%) Hispanic 2 (4%) Black 1 (2%) Weight (kg) median (IQR) 70 (62, 85) Height (cm) median (IQR) 172 (163, 178) Body-mass index (BMI) median (IQR) 24 (22, 27) Glycated hemoglobin (%) median (IQR) 6.8 (6.4, 7.6) Diabetes duration (yr) median (IQR) 15 (12, 26) Daily insulin dose (U/day) median (IQR) 45 (32, 60) 40 Predictive Low Glucose Suspend (PLGS) Home Study Randomization Did not meet hypoglycemia criteria N=4 Enrolled N= 50 Randomized 45 participants 2,007 nights Did not meet complete system use criteria N=1 Control 1,002 nights Intervention 1,005 nights <4 hrs of CGM data 32 nights Analyzed 970 nights Analyzed 942 nights <4 hrs of CGM data 63 nights Study Results 41 Safety Rules 1. Suspend for no more than 120 out of every 150 minutes. 2. Suspend for no more than 180 min/night. 3. Do not suspend when the glucose is rising 4. Suspend if CGM<70 mg/dl 5. Do not suspend if the CGM is above 230 mg/dl. 6. Do not suspend if the CGM is dropping by more than -8 mg/dl/min. Algorithm Description 42 14

Example Plot Figure 1. Sample overnight data profile for intervention night System Description 43 Overall Results Control 45 Participants Intervention 45 Participants P-value 125 (98, 163) 132 (110, 163) <0.001 Overnight Mean Glucose median (IQR) Percentage of glucose between 70-180 75% (46%, 82% (54%, <0.001 mg/dl median (IQR) 93%) 99%) Morning BG mg/dl a median (IQR) 129 (96, 173) 144 (114, 186) <0.001 % mornings with BG 60 mg/dl 4% <1% <0.001 70 mg/dl 9% 2% <0.001 71-180 mg/dl 70% 70% 0.82 >180 mg/dl 21% 27% 0.001 >250 mg/dl 6% 6% 0.83 mornings w/ blood ketone >1 mmol/l b 0.3% 0.1% 0.62 c mornings w/ urine ketones 15 mg/dl d 2% 3% 0.07 a 1 morning blood glucose measurement in the control arm was missing b 9 blood ketone measurements in the control arm and 10 blood ketone measurements in the intervention arm were missing c P value computed using Fisher s exact test, which does not account for the correlated data. Too few events (3 in control arm vs. 1 in intervention arm) to detect any significant difference. d 12 urine ketone measurements in the control arm and 12 urine ketone measurements in the intervention arm were missing 44 Overall Results Control Intervention 45 Participants 45 Participants P-value # Nights 970 942 Bedtime BG mg/dl median (IQR) 152 (114, 197) 144 (115, 195) # measurements per night 96 (84, 110) 96 (85, 107) % nights with >1 value 60 mg/dl 33% 21% <0.001 % nights with >1 value 50 mg/dl 19% 10% <0.001 % nights with >1 value 70 mg/dl 45% 32% <0.001 Low blood glucose index median (IQR) 0.7 (0.0, 3.5) 0.4 (0.0, 1.8) <0.001 % nights with >1 value >250 mg/dl 20% 20% 0.93 % nights with >1 value >180 mg/dl 57% 59% 0.17 % nights with >1 value >300 mg/dl 5% 6% 0.37 High blood glucose index median (IQR) 1.9 (0.3, 6.2) 2.4 (0.5, 6.5) <0.001 45 15

Hypo and Hyperglycemia Control N=45 Participants Intervention N=45 Participants P-value # Nights 970 942 Hypoglycemia % nights with glucose 60 mg/dl for > 30 min 24% 12% <0.001 > 60 min 18% 8% <0.001 > 120 min 11% 3% <0.001 > 180 min 8% 1% <0.001 Hyperglycemia % nights with glucose >250 mg/dl for > 30 min 12% 13% 0.80 > 60 min 9% 8% 0.74 > 120 min 5% 6% 0.35 46 Outpatient Glucose Levels Percent of nights with a CGM 60 mg/dl at a given time (dashed lines) 47 Pump Suspension Duration # Nights 942 Nights with Pump Suspension All durations 719 (76%) 1 30 min 185 (20%) 31 60 min 114 (12%) 61 120 min 262 (28%) >120 min 158 (17%) Shutoff Duration Per Night (minutes) a median (IQR) 71 (29, 115) a Restricted to 719 nights with at least one pump suspension. 48 16

Morning Blood and Urine Ketones Control N=45 Participants Intervention N=45 Participants # Mornings 970 942 Morning Measures % mornings with a blood ketone a 0 mmol/l 14% 14% 0.1 mmol/l 64% 63% 0.2 0.3 mmol/l 19% 20% 0.4 0.6 mmol/l 2% 2% 0.7 mmol/l 0.6% 0.6% % mornings with a urine ketone b 40 mg/dl 0.7% 0.2% 80 mg/dl 0.1% 0 a-9 blood ketone measurements in the control group and 10 blood ketone measurements in the intervention group were missing b-12 urine ketone measurements in the control arm and 12 urine ketone measurements in the intervention arm were missing 49 Summary Bionic or Artificial Pancreas (AP) I. Low Glucose (Threshold) Suspend (LGS) - a reality II. Predictive Low Glucose Suspend (PLGS) - Will still need Phase III clinical trials III. Overnight Glucose Control - Studies in progress throughout the world IV. Complete AP - Studies in progress/other advances needed THANK YOU 17