Non surgical predicting factors for patient satisfaction after third molar surgery

Similar documents
MA. Hemodynamic and ventilatory changes during implant. with intravenous conscious sedation

Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction

MA. Anxiety before extraction of impacted lower third

Quality of life after upper third molar removal: A prospective longitudinal study

Flap repositioning versus conventional suturing in third molar surgery

Evaluation of the agreement by examiners according to classifications of third molars

Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT)

Coronectomy of impacted mandibular third molars: A meta-analysis and systematic review of the literature

Compliance of postoperative instructions following the surgical extraction of impacted lower third molars: A randomized clinical trial

Sensibility and taste alterations after impacted lower third molar extractions. A prospective cohort study

Preemptive analgesic effectiveness of oral ketorolac plus local tramadol after impacted mandibular third molar surgery

Javier Montero 1, Joaquín-Francisco López 2, María-Purificación Vicente 3, María-Purificación Galindo 4, Alberto Albaladejo 5, Manuel Bravo 6

Comparative Evaluation of Two Different Flap Designs and Postoperative Outcome in the Surgical Removal of Impacted Mandibular Third Molar

M. Angeles Fuster Torres 1, Jordi Gargallo Albiol 2, Leonardo Berini Aytes 3, Cosme Gay Escoda 4

Radiographic assessment of lower third molar prior to surgery: A report of four cases

Influence of first and second premolar extraction or non-extraction treatments on mandibular third molar angulation and position. A comparative study

CORONECTOMY OF MANDIBULAR WISDOM TEETH: A CASE SERIES AND BRIEF REVIEW OF LITERATURE

Kissing molars extraction: Case series and review of the literature

A Preferable Technique for Protecting the Inferior Alveolar Nerve: Coronectomy

Efficacy and complications associated with a modified inferior alveolar nerve block technique. A randomized, triple-blind clinical trial

extraction and describe the evolution of LN sensitivity as well as the prognosis of LN damage based on preoperative data.

Perceived influence of oral health upon quality of life in heart transplant patients.

oral surgeons tobacco-use-related knowledge and intervention behaviors.

Coronectomy versus surgical removal of the lower third molars with a high risk of injury to the inferior alveolar nerve. A bibliographical review

Functional Sensory Recovery After Trigeminal Nerve Repair

Osseointegrated dental implant treatment generally

Karmen Harutunian 1, Jordi Gargallo-Albiol 2, Rui Figueiredo 3, Cosme Gay-Escoda 4

R. Diagnostic criteria in proliferative verrucous leukoplakia: Evaluation.

Dental arch changes from adolescence to adulthood in a spanish population: A cross-sectional study

What are the risk factors for postoperative infections of third molar extraction surgery: A retrospective clinical study?

Cross-sectional study of correlation between mandibular incisor crowding and third molars in young Brazilians

Depression and anxiety disorders in a sample of facial trauma: A study from Iran

D.D.S., PhD., Assist. Prof., Department of Oral and Maxillofacial Surgery, Yuzuncu Yil University Faculty of Dentistry, Van, Turkey 2

Zygomatic implants are suitable for the restoration

Health-related quality of life of patients with zygomatic fracture

The use of pedicled buccal fat pad combined with sequestrectomy in bisphosphonate-related osteonecrosis of the maxilla

Comparative study of analgesia with bupivacaine 0.25% versus 0.5% for third molar removal under general anesthesia

Oral health status of a population with multiple sclerosis

Articaine versus lidocaine for third molar surgery: A randomized clinical study

Posterior mandible and vertical augmentation

Hydrodynamic ultrasonic maxillary sinus lift: Review of a new technique and presentation of a clinical case

Assistant Professor, Department of Oral and Maxillofacial Surgery, S.D. Dental College and Hospital, Parbhani, Maharashtra, India, 2

Association between general and oral health-related quality of life in patients treated for oral cancer

Surgical treatment of localized gingival recessions using coronally advanced flaps with or without subepithelial connective tissue graft

Immediate Loading with Flapless Implant Surgery for Rehabilitation of Single Bound Edentulous Space

PRE-OP and POST-OP SURGICAL CONSIDERATIONS

Upper lip malignant neoplasms. A study of 59 cases

Age as a Risk Factor for Third Molar Surgery Complications

FIVE-YEAR FOLLOW-UP OF IMPLANTS PLACED SIMULTANEOUSLY WITH INFERIOR ALVEOLAR NERVE LATERALISATION OR TRANSPOSITION

Psychological impact of third molar surgery: a 1-month prospective study de Jongh, A.; van Wijk, A.J.; Lindeboom, J.A.H.

Development of a computer application to help in the decision-making process in teaching dentistry

Pharmaceutical care for patients with COPD in Belgium and views on protocol implementation

Haemostatic agents in apical surgery. A systematic review

Evaluation of enamel pearls by cone-beam computed tomography (CBCT)

Narrow-diameter implants in premolar and molar areas

A Case of Incisiform Supernumerary Tooth Along With a Impacted Supplemental Tooth In Anterior Maxillary Region

Relation between the complex diagnostics and the complications of the wisdom-tooth surgery

Zygomatic Implants Using the Sinus Slot Technique: Clinical Report of a Patient Series

The internal responsiveness of the Oral Health Impact Profile-14 to detect differences in clinical parameters related to surgical third molar removal

Erupted odontomas: A report of three cases and review of the literature

Case report: Replacement of failing 2 stage implants by basal implants and conventional bridgework

Influence of bruxism on survival of porcelain laminate veneers

Clinical Perspectives

Relationship between indication for tooth extraction and outcome of immediate implants: a retrospective study with 5 years of follow-up

A. Immediate placement of single implant simultaneously with immediate

Is telephone follow-up really effective in early diagnosis of inflammatory complications after tooth extraction?

Validation of the oral health impact profile (OHIP-20sp) for Spanish edentulous patients

Focus of Today s Presentation. Partners in Healing Model. Partners in Healing: Background. Data Collection Tools. Research Design

ABSTRACT INTRODUCTION /jp-journals

01/05/2014. Background. Minimally invasive tooth extraction. Thomas Dietrich Professor of Oral Surgery University of Birmingham, School of Dentistry

Key words: Antibiotic prophylaxis, third molar surgery, oral surgery.

Immediate implants placed in fresh sockets associated to periapical infectious processes. A systematic review

Incidence of impacted mandibular and maxillary third molars: a radiographic study in a Southeast Iran population

Case Report Intraoral management of iatrogenically displaced lower third molar roots in the sublingual space: a report of 2 cases

Pre-operative evaluation of the volume of bone graft in sinus lifts by means of CompuDent

J Oral Maxillofac Surg 67: , 2009 Value of Informed Consent in Surgical Orthodontics Sander Brons, DDS,* Alfred G. Becking, DMD, MD, PhD, and

Prevalence of systemic diseases among patients requesting dental consultation in the public and private systems

Clinical parameters of implants placed in healed sites using flapped and flapless techniques: A systematic review

Facial blanching after inferior alveolar nerve block anesthesia: an unusual complication

A comparison of two anesthesia methods for the surgical removal of maxillary third molars: PSA nerve block technique vs. local infiltration technique

B U J O D. Original Research

Buccal approach in surgical removal of lingually embedded teeth: a report of 2 cases

Multiple supernumerary teeth not associated with complex syndromes: A retrospective study

Assessment of periapical status: A comparative study using film-based periapical radiographs and digital panoramic images

Etiology, risk factors and management of implant fractures

Children's relations and their subjective wellbeing in an ecological perspective. Shimoni & Ben-Arieh The Hebrew University of Jerusalem Seoul 2013

Efficacy of fentanyl transdermal patch in pain control after lower third molar surgery: A preliminary study

Introduction. Report of a Case BALKAN JOURNAL OF DENTAL MEDICINE ISSN

The extraction of an impacted mandibular. Reliability of panoramic radiography in evaluating the topographic relationship

Validation of the chinese version of the oral health impact profile for TMDs (OHIP- TMDs-C)

Australian Dental Journal

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Radiographic and computed tomography monitoring of a fractured needle fragment in the mandibular branch

Review Article A 5 Year Retrospective Study on the Clinical Outcomes of Performing Arthrocentesis in Basildon Hospital

A lingual orthodontic case with 3M Incognito Appliance System combined with orthognathic surgery.

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Malpractice claims related to tooth extractions. Koskela, Sanna

CIC Edizioni Internazionali

Master in Oral Surgery Implantology and Periodontology 2019

Clients perception of HIV/AIDS voluntary counseling and Testing (VCT) services in Nairobi, Kenya

Transcription:

Journal section: Oral Surgery Publication Types: Research doi:10.4317/medoral.20719 http://dx.doi.org/doi:10.4317/medoral.20719 Non surgical predicting factors for patient satisfaction after third molar surgery José-Carlos Balaguer-Martí 1, Amparo Aloy-Prósper 2, David Peñarrocha-Oltra 2, Miguel Peñarrocha-Diago 3 1 Master of Oral Surgery and Implantology. Valencia University Medical and Dental School 2 Collaborating Professor of Oral Surgery. Master of Oral Surgery and Implantology. Valencia University Medical and Dental School, Valencia, Spain 3 Professor of Oral Surgery. Director of the Master of Oral Surgery and Implantology. Valencia University Medical and Dental School Correspondence: Clínicas odontológicas Gascó Oliag 1 46021- Valencia, Spain miguel.penarrocha@uv.es Received: 14/03/2015 Accepted: 22/11/2015 Balaguer-Martí JC, Aloy-Prósper A, Peñarrocha-Oltra D, Peñarrocha-Diago M. Non surgical predicting factors for patient satisfaction after third molar surgery. Med Oral Patol Oral Cir Bucal. 2016 Mar 1;21 (2):e201-5. http://www.medicinaoral.com/medoralfree01/v21i2/medoralv21i2p201.pdf Article Number: 20719 http://www.medicinaoral.com/ Medicina Oral S. L. C.I.F. B 96689336 - pissn 1698-4447 - eissn: 1698-6946 email: medicina@medicinaoral.com Indexed in: Science Citation Index Expanded Journal Citation Reports Index Medicus, MEDLINE, PubMed Scopus, Embase and Emcare Indice Médico Español Abstract Background: In the third molar surgery, it is important to focus not only on surgical skills, but also on patient satisfaction. Classically studies have been focused on surgery and surgeon s empathy, but there are non-surgical factors that may influence patient satisfaction. Material and Methods: A cross-sectional study was performed on 100 patients undergoing surgical extractions of impacted mandibular third molars treated from October 2013 to July 2014 in the Oral Surgery Unit of the University of Valencia. A questionnaire (20 questions) with a 10-point Likert scale was provided. The questionnaire assessed the ease to find the center, the ease to get oriented within the center, the burocratic procedures, the time from the first visit to the date of surgical intervention, waiting time in the waiting room, the comfort at the waiting room, the administrative staff (kindness and efficiency to solve formalities), medical staff (kindness, efficiency, reliability, dedication), personal data care, clarity in the information received (about the surgery, postoperative care and resolution of the doubts), available means and state of facilities. Outcome variables were overall satisfaction, and recommendation of the center. Statistical analysis was made using the multiple linear regression analysis. Results: Significant correlations were found between all variables and overall satisfaction. The multiple regression model showed that the efficiency of the surgeon and the clarity of the information were statistically significant to overall satisfaction and recommendation of the center. The kindness of the administrative staff, available means, the state of facilities and the comfort at the waiting room were statistically significant to the recommendation of the center. Conclusions: Patient satisfaction directly depends on the efficiency of the surgeon and clarity of the clinical infor- e201

mation received about the procedure. Appreciation of these predictive factors may help clinicians to provide optimal care for impacted third molar surgery patients. Key words: Patient satisfaction, third molar, questionnaire. Introduction In the field of oral and maxillofacial surgery, impacted third molar surgery (ITM) is one of the most common procedures (1). ITM surgery appears to be a relatively minor operation with few complications and little morbidity. However, ITM surgery is often perceived by patients as an intensely frightening situation (2,3). Likewise, a patient is satisfied when a surgery performs better than expected and is dissatisfied when expectations exceed performance. Favorable outcomes leads to patient satisfaction (4,5). However, the relationship between surgeon and patient may be endangered by environmental factors not only surgical outcomes (1,2). Scher et al. (6) highlighted the importance of patient satisfaction within the basic principles in measuring quality. Satisfaction surveys are ways in which the patient is asked about their satisfaction on the health care provided. Moreover, the factors or causes that may influence the level of satisfaction, such as accessibility, technical competence of the professionals, the interpersonal relationships and humane treatment, and cleanliness must be considered. Badia et al. (7) conducted a study in 1998 on the aspects of dental care that are most valued by patients, and it was determined that not all factors are valued in the same way. The most important component for the patient satisfaction reported by the literature was the effectiveness of the surgeon, including technical skills and confidence (8), but there is a lack of evidence for the non-surgical factors related with the ITM surgery. Appreciation of the factors increasing patient satisfaction may guide clinicians to provide optimal care for their patients. Most clinicians, including oral and maxillofacial surgeons, focus only on a desirable surgical outcome when they treat ITM patients. However, a large gap exists between the provision of ideal care and patient recognition of ideal care, because most patients do not have sufficient knowledge to evaluate surgical outcomes. As the patient determines whether a service is acceptable or not, the clinician should know what patients need and prefer, to design and improve the assistance. For this reason, the aim of the present study was to determine significant factors predicting patient satisfaction regarding the center and care provided by practitioners and administrative staff after third molar surgery. Material and Methods - Sample selection An observational cross-sectional study was performed following the STROBE guidelines (9) including 127 patients that underwent surgical extraction of an impacted mandibular third molar (totally covered by bone, totally covered by soft tissues or partially covered by soft tissues) in the Oral Surgery Unit of the University of Valencia from November 2013 to July 2014. The study was approved by the Ethics Committee of the University of Valencia (H1435828552407). The inclusion criteria were healthy patients, older than 18 years, who completed the questionnaire and agreed to follow the postoperative instructions. All patients signed an informed consent to be included in the study. A questionnaire was prepared using a Likert-type scale, consisting of a set of 20 items rated from 1 to 10 (1, strongly disagree; 10, strongly agree) to assess the patient satisfaction related to all questions. The questionnaire assessed the ease to find the center, the ease to get oriented within the center, the burocratic procedures performed during the first day arriving at the center, the time from the first visit to the date of surgical intervention, waiting time in the waiting room the day of the intervention, the comfort at the waiting room, the administrative staff (kindness and efficiency to solve formalities), medical staff (kindness, efficiency, reliability, dedication), personal data protection, clarity in the information received (about the surgery, postoperative care and resolution of the doubts), available means and state of facilities (cleanliness, performance...). These items were selected and included in our questionnaire from different surveys that assessed the patient satisfaction with the Spanish National Health System. The questionnaire was provided to the patient one week after the ITM surgery. The meaning of the questions and the criteria of rating was explained. Subsequently, they were asked to fill in the questionnaire and instructed to give the most accurate rating to the prescribed set of questions. Furthermore, they were instructed to fill out the questionnaire in isolation of the operator or other relatives to avoid any bias in rating the answers to the questions. The patients were instructed to abstain from writing their names or putting their signatures on the questionnaire forms in an effort to protect their identity. e202

The filled questionnaire was collected by the administrative staff, different from the researcher. - Outcome measures Outcome variables to assess patient satisfaction were: the overall satisfaction (SP) and the recommendation of the center (ROC). - Surgical procedure All surgeries were performed using identical surgical instruments and material by one surgeon. The patients were referred from the Spanish National Health System. In all cases, the inferior alveolar, lingual and buccal nerves were anesthetized using 2 cartridges of 1.8 ml of articaine 4% and epinephrine anesthetic solution at 1:100000 Artinibsa (Inibsa, Lliça de Vall, Barcelona, Spain). A vestibular triangular mucoperiosteal flap was raised with a distal incision and vestibular release. The osteotomy and odontectomy were made using a rounded tungsten carbide drill, mounted in a hand piece, with abundant irrigation of sterile physiologic serum. After extracting the molar, the cavity was inspected and sutured with 3-0 silk (Lorca Marin, TB15, 3/8, Murcia, Spain). All patients were prescribed the same prophylactic antibiotic (500mg amoxicillin orally) one tablet every eight hours for one week, and ibuprofen (Bexistar, Laboratory, Bacino, Barcelona, Spain) 600 mg every 8 hours for 4 days. The patients were advised to consume a soft diet for the first 24 hours and to abstain from smoking during the first postoperative week. Brushing at the surgical site was limited to the occlusal or incisal surfaces of the teeth, with careful brushing of all other teeth (brushing 3 times daily). Sutures were removed one week after the surgery. - Statistical analysis The collected data was tabulated and statistically evaluated. Frequency distribution and percentage analysis were done. The internal consistency of the items included in the questionnaire was analyzed with the Cronbach s alpha to ensure that all the items measured the same outcome variable (satisfaction). Spearman s correlation coefficient was used for correlating the individual experience with the OS and ROC variables. Linear regression was used to find correlations between the studied variables and the outcome variables OS and ROC. The Cook s distance was used to assess if the atypical values influence the fit of the regression model. Stratification was performed at the age variable to compare data between ranges of twenty years. The level of statistical significance was established as 5% (a = 0.05). Statistical analysis was completed using SPSS 19.0 software (SPSS Inc., Chicago, IL). Results Of the 127 patients, 27 were excluded from the study for not completing the questionnaire correctly. A total of 100 patients (52 women and 48 men) were included. Their mean age was 31 years (SD 10.9) range 18 to 69. The internal consistency of the items included in the questionnaire was very high (α = 0.94). The mean values of the variables are in the table 1. - Overall satisfaction The mean of the OS variable was 9.43 (SD=1.07) [95% CI=9.22-9.64]. The Spearman s correlation coefficient showed a correlation higher than 0.7 between the OS and the kindness and efficiency of the management staff (0.727 and 0.711, respectively), the kindness, respectfulness and the time surgeon dedicated to talk and listen to the patient (0.767, 0.747 and 0.747 respectively), the efficiency of the surgeon (0.829), the clarity in the information received (0.807) and the state of facilities (0.808). The multiple regression model showed a high goodness of fit after deleting the atypical values (R2=0.759). The statistically significant variables in the model were the practitioner s efficacy (p<0.0001) and the clarity in the information received ( p=0.02). The most important factor was the practitioner s efficacy with a coefficient of 0.94, followed by the clarity of the information provided to the patient with 0.02. No statistically significant differences in the remaining variables were found. The Cook s distance was low in all the deleted atypical values (<0.2), therefore outliers did not influence the fit of the model. - Recommendation of the centre The mean of the ROC variable was 9.52 (SD=1.04) [95% CI=9.31-9.73]. A correlation higher than 0.7 was found between the ROC variable and the kindness and efficiency of the management staff (0.801 and 0.794), the kindness, respectfulness and efficiency of the medical staff (0.826, 0.819, 0.890), dedication (0.787), the clarity in the information received about the surgery and postoperative care (0.899 and 0.764, respectively), the resolution of doubts (0.840), the state of facilities (0.739) and the available means (0.893). The multiple regression model showed a high goodness of fit after deleting the atypical values (R2=0.88). The statistically significant variables in the model were the practitioner s efficacy (p<0.0001), the kindness of the administrative staff (p=0.005), the available means (p=0.005), the state of facilities (p=0.01), the comfort at the waiting room (p=0.01) and the clarity of the information received ( p=0.02). The most important factor was the practitioner s efficiency with a coefficient of 0.89, followed by the administrative staff efficiency (0.02), the available means (0.02), the state of facilities (0.019), the comfort at the waiting room (0.018) and the ease to find the center (0.015). No statistically significant differences in the remaining variables were found. The Cook s distance was moderate in three of the deleted atypical values (<0.35) and low in the two remaining (<0.02). e203

Table 1. Mean and SD of the items included in the questionnaire. Item Mean SD The ease to find the center. 7.2 2.2 The ease to orient within the center. 7.9 1.9 The burocratic procedures performed during the first day arriving at the center. 9.4 0.8 The time from the first visit to the date of surgical intervention. 9.2 0.9 The waiting time in the waiting room. 9.3 0.3 The comfort at the waiting room. 8.2 1.3 The kindness of the administrative staff. 9.8 0.4 The administrative staff is efficient. 9.7 0.5 The kindness of the medical staff. 9.8 0.3 The medical staff is respectful 9.9 0.3 The medical staff lets you talk and listen to you. 9.9 0.2 The medical staff is efficient. 9.7 0.5 The proper care of my privacy and personal data. 9.6 0.8 The clarity of the information received. 9.6 0.6 The resolution of my doubts about the procedure. 9.5 0.7 The state of the facilities (cleanliness, performance ). 8.8 0.9 The available means. 9.6 0.6 The postoperative clinic information received. 9.6 0.6 I will recommend the center. 9.5 0.6 Overall satisfaction. 9.5 0.6 Discussion Some studies in the literature have evaluated the correlation between surgical skills, intraoperative outcomes and postoperative variables with the satisfaction of the patient (8,10) but did not take into account the importance of other factors not directly related to the surgical procedure. This study was designed to assess patient satisfaction after ITM surgery related to the centre (administrative and medical staff and facilities), not intraoperative surgical factors. The OS of the patients was high (9.43), similar to results reported in the literature (11). The results of this study are consistent with other published findings that the most important determinant of patient satisfaction after ITM surgery is the practitioner s efficacy (8). Emmert et al. (12) found that the second most frequently concern of the patients is the practitioner kindness (38%), just after the practitioner s efficiency. Another important concern was dedication (35.9%). The relation of the patient with the professional is important in the overall satisfaction of the treatment (13). In the present study no statistically significant correlation was found between the kindnesses of the practitioner, dedication, and the OS or ROC, although mean values were high. However, the kindness of the staff was statistically significant. Trust between patient and practitioner is based on confidentiality, if the patient feels that their personal data are not treated properly may lead to hide relevant information for diagnosis. In the present study, information about personal data care was explained to the patient who signed an informed consent. This may explain the high mean values (9.5), although not significant, reported. Some complications strongly affect patient quality of life, such as paresthesia of the alveolar, lingual or buccal nerve. These sensory disturbances may be irreversible, so it is important to inform the patient of the existence of such complications before surgery (14). No statistically significant correlation was found between the information provided to the patient, both preoperative and postoperative; and the OS or ROC. The patients are unable to recall in detail much of the information provided to them (14), to avoid this possible source of bias the questionnaire was delivered when the patient came back to remove the suture. Moreover, an excess of information does not always guarantee a greater understanding by the patient (15), may even be counterproductive and increase the level of patient anxiety (16), although van Wijk et al. (17) indicate that the patient is more satisfied when he gets as much information as possible. No statistically significant differences were found between gender or age to overall patient satisfaction, which is consistent with the literature (10). e204

Conclusions Patient satisfaction directly depends on the efficiency of the surgeon and the clarity of the clinical information received about the procedure. Appreciation of these predictive factors may help clinicians to provide optimal care and increasing patient satisfaction after impacted third molar surgery. References 1. Worrall SF, Riden K, Haskell R, Corrigan AM. UK National Third Molar project: the initial report. Br J Oral Maxillofac Surg. 1998;36:14-8. 2. Desjardins PJ. Patient pain and anxiety: the medical and psychologic challenges facing oral and maxillofacial surgery. J Oral Maxillofac Surg. 2000;58:1-3. 3. Litt MD, Nye C, Shafer D. Preparation for oral surgery: evaluating elements of coping. J Behav Med. 1995;18:435-59. 4. Earl P. Patients anxieties with third molar surgery. Br J Oral Maxillofac Surg. 1994;32:293-7. 5. Hermes D, Matthes M, Saka B. Treatment anxiety in oral and maxillofacial surgery. Results of a German multi-centre trial. J Cranio- Maxillofacial Surg. 2007;35:316-21. 6. Scher M, Briggs T, Khan A, Cohen S. Patients satisfaction with care received in teaching settings. Academic-Psychiatry. 1990;14:21-6. 7. Badia X, del Llano J. [Health outcomes research]. Med Clin (Barc). 2000;114 Suppl 3:1-7. 8. Evans AW, Leeson RM, Petrie A. Correlation between a patientcentred outcome score and surgical skill in oral surgery. Br J Oral Maxillofac Surg. 2005;43:505-10. 9. Von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol. 2008;61:344-9. 10. Kim Y, Kim S, Myoung H. Independent predictors of satisfaction in impacted third molar surgery patients. Community Dent Oral Epidemiol. 2010;38:274-86. 11. Lopes V, Mumenya R, Feinmann C, Harris M. Third molar surgery: an audit of the indications for surgery, post-operative complaints and patient satisfaction. Br J Oral Maxillofac Surg. 1995;33:33-5. 12. Emmert M, Meier F, Heider AK, Dürr C, Sander U. What do patients say about their physicians? An analysis of 3000 narrative comments posted on a German physician rating website. Health Policy (New York). 2014;118:66-73. 13. Famiglietti RM, Neal EC, Edwards TJ, Allen PK, Buchholz TA. Determinants of patient satisfaction during receipt of radiation therapy. Int J Radiat Oncol Biol Phys. 2013;87:148-52. 14. Ferrús-Torres E, Valmaseda-Castellón E, Berini-Aytés L, Gay- Escoda C. Informed consent in oral surgery: The value of written information. J Oral Maxillofac Surg. 2011;69:54-8. 15. Christensen J, Matzen LH, Wenzel A. Effect of explaining radiographic information to the patient before third molar surgery. Dentomaxillofacial Radiol. 2010;39:176-8. 16. Torres-Lagares D, Heras-Meseguer M, Azcárate-Velázquez F, Hita-Iglesias P, Ruiz-de-León-Hernández G, Hernández-Pacheco E, et al. The effects of informed consent format on preoperative anxiety in patients undergoing inferior third molar surgery. Med Oral Patol Oral Cir Bucal. 2014;19:e270-3. 17. Van Wijk AJ, Buchanan H, Coulson N, Hoogstraten J. Preparatory information for third molar extraction: Does preference for information and behavioral involvement matter? Patient Educ Couns. 2010;79:94-9. Conflicts of interest The authors declare that there is no conflicts of interest regarding the publication of this paper. e205