Work partially supported by VisionRT

Similar documents
Overview of MLC-based Linac Radiosurgery

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

Frameless, real-time, surface imaging-guided radiosurgery: update on clinical outcomes for brain metastases

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Inter-fractional Positioning Study for Breast Cancer with Proton Therapy using a 3D Surface Imaging System

Protura Robotic Patient Positioning System. for efficiency + performance

Image Guided in Radiation Therapy (IGRT) Chumpot Kakanaporn Med Phys Radiation Oncology Siriraj Hospital

SRS Uncertainty: Linac and CyberKnife Uncertainties

EORTC Member Facility Questionnaire

Image Guided Stereotactic Radiotherapy of the Lung

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Case Study. Institution Farrer Park Hospital

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Leksell Gamma Knife Icon A New User s Perspective

Implementation of advanced RT Techniques

Dosisverifikation mit Delta 4 Discover während der Behandlung

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Unrivaled, End-to-End

ph fax

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Performance Evaluation of Calypso (R) 4D Localization and Kilovoltage Image Guidance Systems for Interfraction Motion Management of Prostate Patients

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

brain SPINE 2 SRS Matures into breast lung spine LUNG Dr. Robert Timmerman Discusses SBRT for Inoperable Lung Cancer BRAIN

Cyberknife Stereotactic Treatment

SRS Plan Quality and Treatment Efficiency: VMAT vs Dynamic Conformal ARCs

Credentialing for the Use of IGRT in Clinical Trials

Clinical evaluation of interfractional variations for whole breast radiotherapy using 3-dimensional surface imaging

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

pat hways Medtech innovation briefing Published: 16 May 2018 nice.org.uk/guidance/mib147

Many vendors are beginning to allow couch motion during radiation delivery.

Surface imaging-based analysis of intrafraction motion for breast radiotherapy patients

Dosimetric effects of positioning shifts using 6D-frameless stereotactic Brainlab system in hypofractionated intracranial radiotherapy

X-Ray Guided Robotic Radiosurgery for Solid Tumors

Motion gating and tracking techniques: overview and recent developments

IGRT/Adaptive Gating

I. Equipments for external beam radiotherapy

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

Leksell Gamma Knife Icon. Treatment information

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

A Patient s Guide to SRS

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University

The High-End Solution for Real-Time Patient Tracking

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

Estimation of patient setup uncertainty using BrainLAB Exatrac X-Ray 6D system in image-guided radiotherapy

02 CyberKnife: Treatment Delivery

Assessment of interfractional variation of the breast surface following conventional patient positioning for whole-breast radiotherapy

Minimal mask immobilization with optical surface guidance for head and neck radiotherapy

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Leila E. A. Nichol Royal Surrey County Hospital

Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Stereotactic Radiosurgery

Deep Inspiration Breath-Hold Techniques: a review of voluntary and controlled breath-hold maneuvers for left-side breast radiation therapy

Quality assurance in external radiotherapy

SBRT in early stage NSCLC

Chapters from Clinical Oncology

In-Room Radiographic Imaging for Localization

Additional Questions for Review 2D & 3D

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

1 : : Medical Physics, Città della Salute e della Scienza, Torino, Italy

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Disclosures. Overview 8/3/2016. SRS: Cranial and Spine

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Image Fusion, Contouring, and Margins in SRS

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Integrating the Radixact into a Highly Comprehensive Center

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

Trilogy Stereotactic System Stereotactic, IMRT, and 3D CRT in one system

In-Room Radiographic Imaging for Localization

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Tania Kaprealian, M.D. Assistant Professor UCLA Department of Radiation Oncology August 22, 2015

7/28/2012. Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures***

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Treatment accuracy without rotational setup corrections in intracranial SRT

Importance of daily portal imaging for Head and Neck IMRT treatments. Luciant Wolfsberger Brigham & Women s Hospital

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Proton Beam Therapy at Mayo Clinic

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Migration from full-head mask to open-face mask for immobilization of patients with head and neck cancer

Transcription:

Work partially supported by VisionRT

Background of frameless intracranial stereotactic radiosurgery UCSD SRS/SRT procedure Clinical Results Summary Total prescribed doses : order of 10 50 Gy Planning targets are small : from 1 to 35 cm 3. Positional and numerical accuracy in dose delivery are ±1mm and ±5%, respectively. Accurate determination of the target volume and its location with stereotactic techniques. Conformal Dose distributions : sharp dose fall off outside the target volume. Accurate knowledge of the total dose and fractionation scheme required for treatment of a particular disease.

Patient comfort Ease of treatment Similar or better accuracy of positioning Potential for hypofractionated treatments

IGRT techniques for accurate patient positioning / monitoring Radiographic localization Non radiographic localization Better precision of hardware in treatment machine High precision mechanics (Couch, Gantry, MLC etc.) Full automatic 6DOF couch Manual Head Adjuster for 3D rotation Real time setup and monitoring VisionRT surface imaging Immobilization approaches Passive Minimally Active

Stereo photography 3 cameras & visible light projector Reference image = Contours from DICOMRT, Previous AlignRT image Registration algorithm Minimize distance between reference image and real time surface Rotations & translations Compare AlignRT monitoring Zmed monitoring Observe motion due to couch movements Use calibration SRS phantom with ZMed Use Rando head phantom with AlignRT Cervino et al. Phys Med Biol. 2010

Results: Translations Difference in motions detected by Zmed and AlignRT (Average = 0.93mm) Cervino et al. Phys Med Biol. 2010 Results: Rotations Couch angle 90 deg. 45 deg. 315 deg. 270 deg. Vert. (mm) 0.4 0.2 0.2 0.4 Lat. (mm) 0.6 0.3 0.4 0.6 Lng. (mm) 0.8 0.8 0.3 0.1 Head yaw ( ) 0.2 0.1 0.2 0.2 Head pitch ( ) 0.1 0.0 0.3 0.7 Head roll ( ) 1.0 0.3 0.1 0.3 Cervino et al. Phys Med Biol. 2010

Detecting shifts with a torso phantom Sub millimeter accuracy (0.75 mm) for the 3 translational degrees of freedom and less than 0.1 for each rotation Bert et al. Med Phys. 2005 Detecting shifts with a head phantom 1D motion detection was 0.1 mm±0.1 mm, dependent on the CT skin definition with 0.4 mm variation Li et al. Med Phys. 2011 Patient Simulation CT Simulation Create mask & head cushion Plan and isocenter Planning Create body contour FMB Image registration Importing plan & body contour Select ROI Manual head adjuster Initial setup Start from bridge of nose Capturing new reference Image CBCT image registration Capture new reference surface Monitoring Treatment Adjust if needed

Varian TrueBeam Varian Eclipse V10 AlignRT V 5.0.517 with HD Camera Manual Head Adjuster Daily QA phantom Monthly QA phantom Not a real patient

Body contour Resolution of target structure Smaller calculation grid size Origin @ bridge of nose (shift information to isocenter) PTV margin info @ setup note Documenting AP/LAT BEV (Body contour) with graticule Plan evaluation 100 cm SSD for setup

Initial setup: moves from the bridge of nose with given shift numbers Two therapists: one looks after rotations another after shifts

Target: < 0.5 mm, < 0.5 Co registration to CBCT approved by a radiation oncologist New reference surface after CBCT based shifts Expect small deviations

Beam off if out of tolerance (depends on setup margin) General Tolerance Any translational < 1mm Any rotations < 1 3D MAG < 1.0 mm

Board with distinct pattern 100 cm SSD, Align with cross hair Verification of camera calibration

Level and set to lasers Precisely setup with AlignRT Test plan with deliberate shift 1 cm in each direction Verify with kv/kv, CBCT and MV Matching to fiducials has to show 10 mm shifts in each direction End to End test tolerance +/ 1.5 mm kv/kv + CBCT, move couch from CBCT, MV orthogonal pair

After couch moves Align RT report required shifts Have to match 10 mm shifts made This completes the loop including shifts seen by Align RT

Tolerance < 1 mm 44 patients 115 intracranial metastases Median follow up of 4.7 months 1 year actuarial local control rate was 84% 95% confidence interval: 69 99% Pan et al. Neurosurgery, 2012, 71 (4) : 844 852

Comparison of local control & survival for retrospective studies of brain metastases treated with radiosurgery Treatment System Pts (n) Actuarial 1y LC* (%) Actuarial 1y Survival (%) Frame-based linac 80 89 33 Frame-based Gamma Knife 205 71 37 Frameless linac 53 80 44 Frameless linac 65 76 40 Frameless, surface-imaging guided linac *LC: local control; -: not reported; estimated from Kaplan-Meier curve 44 84 37 Frameless SRS treatments with surface imaging are able to achieve the required level of accuracy Accuracy and precision of the system could be improved and verified with updated hardware (HD camera, 6D couch etc.) and an optimized QA program UCSD has established FMB intracranial stereotactic radiosurgery as its sole SRS/SRT technique

Todd Pawlicki, Ph.D. Steve Jiang, Ph.D. Vitali Moiseenko, Ph.D. Adam Paxton, Ph.D. UCSD SRS TEAM Kevin Murphy, M.D. Parag Sanghvi, M.D. Jona Hattangadi, M.D. Clark Chen, M.D. Grace Kim, Ph.D. Jane Uhl, CMD