The INVOS Cerebral/Somatic Oximeter Monitors Cerebral Perfusion in: Carotid Endarterectomy (CEA)

Similar documents
MONITOR CEREBRAL PERFUSION IN CAROTID ENDARTERECTOMY (CEA)

MONITORING CEREBRAL PERFUSION IN CAROTID ENDARTERECTOMY

Measurements of oxygen saturation of brain, liver and heart areas in the supine and sitting position using near infrared spectrophotometry

Optical methods based on near-infrared spectroscopy. Tissue Oxygen Index Thresholds for Cerebral Ischemia Using Near-Infrared Spectroscopy

CEA and cerebral protection Volodymyr labinskyy, MD

On behalf of the education Committee of the SNACC

Local Haemodynamic Changes During Carotid Endarterectomy The Influence on Cerebral Oxygenation

IMPROVE PATIENT OUTCOMES AND SAFETY IN ADULT CARDIAC SURGERY.

Anesthesia and the beach chair position

The contribution of the external carotid artery to cerebral perfusion in carotid disease

Absolute Cerebral Oximeters for Cardiovascular Surgical Cases

Accuracy of Cerebral Monitoring in Detecting Cerebral Ischemia during Carotid Endarterectomy

Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusion

Cerebral monitoring during carotid endarterectomy by transcranial Doppler ultrasonography

INVOS System Inservice Guide for Pediatric Use. INVOS System Inservice Guide for Pediatric Use

Cerebral oxygen saturation is improved by xenon anaesthesia during carotid clamping

ISPUB.COM. Intraoperative Neurophysiologic Monitoring. M Dinkel, U Beese, M Messner OBJECTIVES AND METHODS

CERVICAL PLEXUS BLOCK FOR CAROTID ENDARTERECTOMY FOLLOWED BY GENERAL ANESTHESIA FOR ABDOMINAL AORTIC SURGERY

Stanford Neuroanesthesia Syllabus: Journal Article Directory (click on section heading)

Case Report. Gholamreza Moradi, MD, Fereydoun Sabzi, MD, Abdolhamid Zokaei, MD *, Naser Hemati, MD

TCD in Anaesthesiology

Cerebral Perfusion Directly Revealed INVOS Cerebral/Somatic Oximeter Improving Patient Outcomes and Safety in Adult Surgery

CEREBRAL OXIMETRY IS FREQUENTLY A FIRST ALERT INDICATOR OF ADVERSE OUTCOMES

Total Arch Replacement Using Bilateral Axillary Antegrade Selective Cerebral Perfusion

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

Tissue oxygenation index reflects changes in forearm blood flow after brief ischemia

Co chce/čeká neurochirug od anesteziologa během karotické endarterektomie?

The Clinical Utility of Cerebral Oximetry Monitoring

Introduction. Bumpei Kikuchi, 1 Kazuhiro Ando, 1 Satoshi Nakazawa, 2 Osamu Sasaki, 1 Masatoshi Watanabe, 1 and Akihiko Saito 1

University of Groningen

Cerebral Oximetry is Frequently a First Alert Indicator of Adverse Outcomes

Intraoperative Transcranial Doppler Sonography Monitoring during Carotid Surgery under Locoregional Anaesthesia

Effect of controlled hypotension on regional cerebral oxygen saturation during rhinoplasty: a prospective study

Emboli detection to evaluate risk of stroke

Study on the Associating Factors with Regional Cerebral Oxygen Saturation Values during Cardiopulmonary Bypass

Safety of perioperative cerebral oxygen saturation during debranching in patients with incomplete circle of Willis

Disclosures. Set up audience participation. Test question. Outline. Neuromonitoring What and When? IP for monitoring technology licensed to Medtronic

Chapter 43 Monitoring of Filter Patency During Carotid Artery Stenting Using Near-Infrared Spectroscopy with High Time-Resolution

Yuko Kondo, Kaoru Sakatani, Noriya Hirose, Takeshi Maeda, Jitsu Kato, Setsuro Ogawa, and Yoichi Katayama

Chapter 62 Monitoring of Hemodynamic Change in Patients with Carotid Artery Stenosis During the Tilt Test Using Wearable Near-Infrared Spectroscopy

Cerebral and Lower Limb Near-Infrared Spectroscopy in Adults on Extracorporeal Membrane Oxygenation

Near-Infrared Monitoring of Brain and Tissue Oxygenation: Is the Monitor on the Right Person?

Continuous Monitoring of Jugular Bulb Venous Oxygen Saturation for Evaluation of Cerebral Perfusion during Carotid Endarterectomy

Differentiation of Emboli

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

GUIDELINE FOR RECOVERY ROOM MANAGEMENT OF PATIENTS AFTER CAROTID ENDARTERECTOMY

Disclosures. State of the Art Management of Carotid Stenosis. NIH funding for clinical trials Consultant for Scientia Vascular and Medtronic

IOM at University of. Training for physicians. art of IOM. neurologic. injury during surgery. surgery on by IOM. that rate is.

Posted: 11/27/2011 on Medscape; Published Br J Anaesth. 2011;107(2): Oxford University Press

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Effect of Head and Neck Positioning on Cerebral Perfusion During Shoulder Arthroscopy in Beach Chair Position

CARDIOVASCULAR Near-infrared spectroscopy as an index of brain and tissue oxygenation

Letter to the Editor: test occlusion under monitoring of motor-evoked potentials for giant distal

Goals and Objectives of the Educational Program

Jacques T. YaDeau, MD, PhD Spencer S. Liu, MD Heejung Bang, PhD Pamela M. Shaw, BS Sarah E. Wilfred, BA Teena Shetty, MD Michael Gordon, MD

Effect of carotid revascularization on cerebral autoregulation in combined cardiac surgery

Neuro Quiz 29 Transcranial Doppler Monitoring

Carotid Stenting and Surgery in 2016 in Russia

Lisa T. Hannegan, MS, CNS, ACNP. Department of Neurological Surgery University of California, San Francisco

Carotid Disease and CABG: What is the best Treatment

Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy {

Kopp R, Puippe G, Rancic Z, Hofmann M, Pecoraro F, Pfammatter T, Lachat M.. University Hospital Zurich, Switzerland

Prediction of Cerebral Ischemic Tolerance During Carotid Cross-clamping by Angiographic Criteria

Shobana Rajan, M.D. Associate staff Anesthesiologist, Cleveland Clinic, Cleveland, Ohio

Development of a New Rehabilitation System Based on a Brain-Computer Interface Using Near-Infrared Spectroscopy

Open heart surgery or carotid endarterectomy. Which procedure should be done first?

Controversies in Carotid Endarterectomy

The Change in Regional Cerebral Oxygen Saturation after Stellate Ganglion Block

Chapter 19 Detection of ROSC in Patients with Cardiac Arrest During Chest Compression Using NIRS: A Pilot Study

SdO 2. p Hypothermic circulatory arrest: HCA n = 6 Continuous retrograde cerebral perfusion: retrograde cerebral perfusion: IRCP

Carotid endarterectomy as complex intraoperative monitoring

Carotid endarterectomy

State of the Art Multimodal Monitoring

PERIOPERATIVE MYOCARDIAL INFARCTION THE ANAESTHESIOLOGIST'S VIEW

Ann Thorac Cardiovasc Surg 2015; 21: Online June 30, 2015 doi: /atcs.oa Original Article

Current Reviews for Nurse Anesthetists

Comparison of carotid artery stenting results in primary stenosis and post-surgical restenosis

The Effect of Optimising Cerebral Tissue Oxygen Saturation on Markers of Neurological Injury during Coronary Artery Bypass Graft Surgery

TCAR: TransCarotid Artery Revascularization Angela A. Kokkosis, MD, RPVI, FACS

Transcranial Doppler Ultrasonography, 2e

Carotid Endarterectomy for Symptomatic Complete Occlusion of the Internal Carotid Artery

Surgical Treatment of Carotid Disease

Advances in the treatment of posterior cerebral circulation symptomatic disease

Association of Intraoperative Transcranial Doppler Monitoring Variables With Stroke From Carotid Endarterectomy

Transcranial Doppler and Electroencephalographic Monitoring

Endovascular treatment for pseudoocclusion of the internal carotid artery

noninvasive, nonionizing, portable, inexpensive, safe for serial or prolonged studies

Hyperperfusion syndrome after MCA embolectomy a rare complication?

Major Aortic Reconstruction; Cerebral protection and Monitoring

Accepted Manuscript. Perioperative renal function and thoracoabdominal aneurysm repair: Where do we go from here? Leonard N. Girardi, M.D.

General Anaesthesia versus Cervical Block and Perioperative Complications in Carotid Artery Surgery

The first oximetry system to put regional oximetry, pulse oximetry and ease of use at your fingertips.

Depth of Anesthesia Monitoring in Cardiac Surgery. Adam Dryden MD, FRCPC University of Ottawa Heart Institute

PREVENT COMPLICATIONS IN MAJOR SURGERY

Carotid Artery Stenosis

Protocol. Intraoperative Neurophysiologic Monitoring (sensoryevoked potentials, motor-evoked potentials, EEG monitoring)

CHAPTER 5. Symptomatic and Asymptomatic Retinal Embolism Have Different Mechanisms

010050,Inner Mongolia, China

MORTALITY AND MORBIDITY RISK FROM CAROTID ARTERY ATHEROSCLEROSIS. 73 year old NS right-handed male applicant for $1 Million life insurance

Case Discussions Cynthia A. Wong, M.D.

Transcription:

The INVOS Cerebral/Somatic Oximeter Monitors Cerebral Perfusion in: Carotid Endarterectomy (CEA) Common methods of monitoring the adequacy of bilateral perfusion and identifying the need for shunting during CEA under general anesthesia are electroencephalogram (EEG), stump pressure (SP), or transcranial Doppler (TCD) monitoring. EEG monitoring requires specialized staff, SP monitoring is not continuous, and some patients have an insufficient temporal bone window for TCD monitoring. Near infrared spectroscopy (NIRS) can be a practical, continuous method to monitor perfusion. The INVOS Cerebral/Somatic Oximeter is NIRS-based technology that can be used to monitor cerebral perfusion during CEA and help clinicians identify patients who may benefit from shunting. In a retrospective study of 594 CEA patients, INVOS monitoring technology was moderately sensitive and specific for identifying patients who would experience a postoperative neurologic deficit after intraoperative cerebral desaturation.1 In two prospective, observational studies in 100 or more CEA patients, INVOS monitoring technology was 76-100% predictive of the need for shunting compared to EEG.2,3 When paired with an interventional algorithm for responding to cerebral desaturation, a multicenter, randomized controlled trial in 253 patients demonstrated that INVOS monitoring technology could assist clinicians in selecting appropriate patients for shunting, significantly reducing the number of patients shunted compared to unmonitored patients with no increase in the incidence of neurological deficits.4 NEXT >

Mille T, Tachimiri ME, Klersy C, et al. Near infrared spectroscopy monitoring during carotid endarterectomy: which threshold value is critical? Eur J Vasc Endovasc Surg. 2004;27(6):646-50. Study design Arms Objective N 594 Single center, retrospective study (Italy) Single arm: INVOS monitoring Identify the relative change from baseline rso 2 values 2 minutes after clamping that is predictive of impending cerebral ischemia Population Threshold for intervention Results Conclusions CEA under general anesthesia No interventions were described and no shunts were placed 20/594 patients (3.4%) presented with neurological complications 16/594 patients (2.7%) showed an early decrease in rso 2 >20% from baseline 6/16 patients (37.5%) showing an early decrease in rso 2 >20% from baseline also presented with neurological complications 14/578 patients (2%) showing a decrease in rso 2 <20% from baseline presented with neurological complications (p=0.0001) An rso 2 decrease of 11.7% from baseline at 2 minutes post-clamping was identified as the optimal threshold to identify patients with a neurological complication Positive predictive value (PPV) = 10% Negative predictive value (NPV) = 99% Sensitivity = 75% Specificity = 77% A threshold of 20% was associated with lower sensitivity (30%), higher specificity (98%), and with a PPV and NPV of 37% and 98%, respectively, for identifying patients with neurological complications NIRS monitoring technology is a useful method to detect cerebral ischemia during CEA 2

practical method compared to EEG to Botes K, Le Roux DA, Van Marle J. Cerebral monitoring during carotid endarterectomy a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure. S Afr J Surg. 2007;45(2):43-6. Study design Arms Objective N 100 Single center, prospective observational study (South Africa) Single arm: concomitant INVOS, electroencephalogram (EEG), and stump pressure (SP) monitoring Compare the ability of INVOS monitoring technology to SP and EEG in detecting the need for shunting Population Definition of desaturation Threshold for intervention Results Conclusions CEA under general anesthesia rso 2 >20% from baseline value Shunt was placed when EEG detected an attenuation or loss of higher-frequency background activity and appearance or increase of regional delta activity 6/100 (6%) of patients were shunted based on EEG changes In 6/6 cases, rso 2 also dropped to >20% from baseline values In 12/94 of the remaining patients not shunted, rso 2 dropped to >20% from baseline values without EEG changes, although a change in blood pressure was observed 82 patients showed no change in EEG or rso 2 drop of >20% from baseline Compared to EEG, rso2 demonstrated the following with respect to indications for shunting Sensitivity = 100% Specificity = 87.2% PPV = 33.3% NPV = 100% False positives = 66.6% False negatives = 0% SP showed a PPV of 12% and NPV of 97% compared to EEG NIRS monitoring technology can be considered as a practical and non-invasive method to monitor ischemia, with the added benefit of providing an early warning for changes in blood pressure. 3

to inform shunt selection during CEA Pennekamp CWA, Immink RV, den Ruijter HM, et al. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy. Eur J Vasc Endovasc Surg. 2013;46(4):397-403. Study design Arms Objective N 151 Single center, prospective observational study (The Netherlands) Single arm: concomitant INVOS, EEG, and transcranial Doppler (TCD) monitoring Compare the ability of INVOS monitoring technology and TCD to EEG in detecting cerebral ischemia and determining the need for shunting to inform shunt selection during CEA Population Definition of desaturation Threshold for intervention Results Conclusions CEA under general anesthesia in patients with a sufficient TCD window rso 2 16% from baseline value Shunt was placed when EEG detected the occurrence of new delta or theta activity 17/151 (11%) of patients were shunted based on EEG changes In 16/17 cases, rso 2 also dropped to 16% from baseline value In 5/134 of the remaining patients not shunted, rso 2 dropped to 16% from baseline value without EEG changes 129 patients showed no change in EEG or rso 2 drop of 16% from baseline value Compared to EEG, rso 2 demonstrated the following with respect to indications for shunting PPV = 76% NPV = 99% Sensitivity = 94% Specificity = 96% Similar results were seen with TCD, although the PPV and specificity were lower at 53% and 90%, respectively Trend towards higher incidence of stroke in shunted patients was seen (11.8% vs 1.5%; p=0.06) NIRS monitoring technology may be effective for shunt selection, and the optimal threshold for shunt selection requires further study 4

need for shunt placement during CEA Zogogiannis ID, Iatrou CA, Lazarides MK, et al. Evaluation of an intraoperative algorithm based on near-infrared refracted spectroscopy monitoring, in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy. Middle East J Anaesthesiol. 2011;21(3):367-73. Study design Arms Objective Multicenter, prospective, randomized controlled trial (Greece) Group A: INVOS monitoring and use of an interventional protocol to restore rso 2 Group B: INVOS monitoring without the use of an interventional protocol Group C: Control, no INVOS monitoring used Examine the effect of using NIRS monitoring with an interventional protocol on the decision to place a shunt N 253 Population CEA under general anesthesia Threshold for intervention Results Conclusions rso 2 >20% of baseline value prompts employment of interventional protocol, including consideration to place a shunt The incidences of shunt placement were significantly different between groups (p<0.001): Group A= 27.7% Group B = 59.5% Group C= 100% Compared to Group A, patients in Groups B and C had a 3.7 times and 70.6 times greater likelihood of receiving a shunt, respectively Compared to Group B, Group C had a 19.4 times greater likelihood of receiving a shunt No difference in neurologic deficits was observed between the three groups NIRS monitoring technology paired with the use of a specific treatment algorithm may aid in the selective shunting of patients undergoing CEA 5

carotid endarterectomy surgery Pennekamp CWA, Immink RV, den Ruijter HM, Kappelle LJ, Bots ML, Buhre WF, Moll FL, de Borst GJ. Nearinfrared spectroscopy to indicate selective shunt use during carotid endarterectomy. Eur J Vasc Endovasc Surg. 2013;46(4):397-403. Uchino H, Nakamura T, Kuroda S, Houkin K, Murata J, Saito H. Intraoperative dual monitoring during carotid endarterectomy using motor evoked potentials and near-infrared spectroscopy. World Neurosurg. 2012;78(6):651-7. Picton P, Ramachandran SK, Shanks A, Dorje P, Mashour GA. Optimizing cerebral oxygenation in anaesthetized patients with carotid artery stenosis: the influence of inspired oxygen fraction. Br J Anaesth. 2012;108(2):326-7. Pennekamp CW, Immink RV, den Ruijter HM, Kappelle LJ, Ferrier CM, Bots ML, Buhre WF, Moll FL, de Borst GJ. Near-infrared spectroscopy can predict the onset of cerebral hyperperfusion syndrome after carotid endarterectomy. Cerebrovasc Dis. 2012;34(4):314-21. Zogogiannis ID, Iatrou CA, Lazarides MK, Vogiatzaki TD, Wachtel MS, Chatzigakis PK, Dimitriou VK. Evaluation of an intraoperative algorithm based on near-infrared refracted spectroscopy monitoring, in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy. Middle East J Anaesthesiol. 2011;21(3):367-73. Tambakis CL, Papadopoulos G, Sergentanis TN, Lagos N, Arnaoutoglou E, Labropoulos N, Matsagkas MI. Cerebral oximetry and stump pressure as indicators for shunting during carotid endarterectomy: comparative evaluation. Vascular. 2011;19(4):187-94. Ritter JC, Green D, Slim H, Tiwari A, Brown J, Rashid H. The role of cerebral oximetry in combination with awake testing in patients undergoing carotid endarterectomy under local anaesthesia. Eur J Vasc Endovasc Surg. 2011;41(5):599-605. Ali AM, Green D, Zayed H, Halawa M, El-Sakka K, Rashid HI. Cerebral monitoring in patients undergoing carotid endarterectomy using a triple assessment technique. Interact Cardiovasc Thorac Surg. 2011;12(3):454-7. 6

carotid endarterectomy surgery Moritz S, Schmidt C, Bucher M, Wiesenack C, Zimmermann M, Schebesch KM, Kasprzak P, Metz C. Neuromonitoring in carotid surgery: are the results obtained in awake patients transferable to patients under sevoflurane/fentanyl anesthesia? J Neurosurg Anesthesiol. 2010;22(4):288-95. Giustiniano E, Alfano A, Battistini GM, Gavazzeni V, Spoto MR, Cancellieri F. Cerebral oximetry during carotid clamping: is blood pressure raising necessary? J Cardiovasc Med (Hagerstown). 2010;11(7):522-8. Baikoussis NG, Karanikolas M, Siminelakis S, Matsagas M, Papadopoulos G. Baseline cerebral oximetry values in cardiac and vascular surgery patients: a prospective observational study. J Cardiothorac Surg. 2010;5:41. Picton P, Chambers J, Shanks A, Dorje P. The influence of inspired oxygen fraction and end-tidal carbon dioxide on post-cross-clamp cerebral oxygenation during carotid endarterectomy under general anesthesia. Anesth Analg. 2010;110(2):581-7. Pugliese F, Ruberto F, Tosi A, Martelli S, Bruno K, Summonti D, D Alio A, Diana B, Anile M, Panico A, Speziale F, Pietropaoli P. Regional cerebral saturation versus transcranial Doppler during carotid endarterectomy under regional anaesthesia. Eur J Anaesthesiol. 2009;26(8):643-7. Matsumoto S, Nakahara I, Higashi T, Iwamuro Y, Watanabe Y, Takahashi K, Ando M, Takezawa M, Kira JI. Near-infrared spectroscopy in carotid artery stenting predicts cerebral hyperperfusion syndrome. Neurology. 2009;72(17):1512-8. Stoneham MD, Lodi O, de Beer TC, Sear JW. Increased oxygen administration improves cerebral oxygenation in patients undergoing awake carotid surgery. Anesth Analg. 2008;107(5):1670-5. Lee TS, Hines GL, Feuerman M. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy. Ann Vasc Surg. 2008;22(1):58-62. Moritz S, Kasprzak P, Arlt M, Taeger K, Metz C. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Anesthesiology. 2007;107(4):563-9. 7

carotid endarterectomy surgery Botes K, Le Roux DA, Van Marle J. Cerebral monitoring during carotid endarterectomy a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure. S Afr J Surg. 2007;45(2):43-6. Fassiadis N, Zayed H, Rashid H, Green DW. Invos Cerebral Oximeter compared with the transcranial Doppler for monitoring adequacy of cerebral perfusion in patients undergoing carotid endarterectomy. Int Angiol. 2006 Dec;25(4):401-6. Rigamonti A, Scandroglio M, Minicucci F, Magrin S, Carozzo A, Casati A. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy. J Clin Anesth. 2005;17(6):426-30. El-Dawlatly AA. Carotid endarterectomy: a study of cerebral oxygen saturation vs stump pressure. Middle East J Anaesthesiol. 2004;17(6):1037-44. Mille T, Tachimiri ME, Klersy C, Ticozzelli G, Bellinzona G, Blangetti I, Pirrelli S, Lovotti M, Odero A. Near infrared spectroscopy monitoring during carotid endarterectomy: which threshold value is critical? Eur J Vasc Endovasc Surg. 2004;27(6):646-50. Kragsterman B, Pärsson H, Bergqvist D. Local haemodynamic changes during carotid endarterectomy the influence on cerebral oxygenation. Eur J Vasc Endovasc Surg. 2004;27(4):398-402. Cuadra SA, Zwerling JS, Feuerman M, Gasparis AP, Hines GL. Cerebral oximetry monitoring during carotid endarterectomy: effect of carotid clamping and shunting. Vasc Endovascular Surg. 2003;37(6):407-13. Hirofumi O, Otone E, Hiroshi I, Satosi I, Shigeo I, Yasuhiro N, Masato S. The effectiveness of regional cerebral oxygen saturation monitoring using near-infrared spectroscopy in carotid endarterectomy. J Clin Neurosci. 2003;10(1):79-83. Takeda N, Fujita K, Katayama S, Tamaki N. Neurol Med Chir (Tokyo). Cerebral oximetry for the detection of cerebral ischemia during temporary carotid artery occlusion. 2000;40(11):557-62. 8

carotid endarterectomy surgery Samra SK, Dy EA, Welch K, Dorje P, Zelenock GB, Stanley JC. Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anesthesiology. 2000;93(4):964-70. Fearn SJ, Picton AJ, Mortimer AJ, Parry AD, McCollum CN. The contribution of the external carotid artery to cerebral perfusion in carotid disease. J Vasc Surg. 2000;31(5):989-93. de Letter JA, Sie TH, Moll FL, Algra A, Eikelboom BC, Ackerstaff GA. Transcranial cerebral oximetry during carotid endarterectomy: agreement between frontal and lateral probe measurements as compared with an electroencephalogram. Cardiovasc Surg. 1998;6(4):373-7. Carlin RE, McGraw DJ, Calimlim JR, Mascia MF. The use of near-infrared cerebral oximetry in awake carotid endarterectomy. J Clin Anesth. 1998;10(2):109-13. de Letter JA, Sie HT, Thomas BM, Moll FL, Algra A, Eikelboom BC, Ackerstaff RG. Near-infrared reflected spectroscopy and electroencephalography during carotid endarterectomy in search of a new shunt criterion. Neurol Res. 1998;20 Suppl 1:S23-7. Duffy CM, Manninen PH, Chan A, Kearns CF. Comparison of cerebral oximeter and evoked potential monitoring in carotid endarterectomy. Can J Anaesth. 1997;44(10):1077-81. Samra SK, Dorje P, Zelenock GB, Stanley JC. Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia. Stroke. 1996;27(1):49-55. Williams IM, Vohra R, Farrell A, Picton AJ, Mortimer AJ, McCollum CN. Cerebral oxygen saturation, transcranial Doppler ultrasonography and stump pressure in carotid surgery. Br J Surg. 1994;81(7):960-4. 9

Now That You ve Read the Evidence Consider using INVOS monitoring in all Carotid Endarterectomy (CEA) Surgeries For more information, contact your Covidien representative or visit covidien.com/rms/products/cerebral-somatic-oximetry 10 < BACK 1. Mille T, Tachimiri ME, Klersy C, et al. Near infrared spectroscopy monitoring during carotid endarterectomy: which threshold value is critical? Eur J Vasc Endovasc Surg. 2004;27(6):646-50. 2. Botes K, Le Roux DA, Van Marle J. Cerebral monitoring during carotid endarterectomy a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure. S Afr J Surg. 2007;45(2):43-6. 3. Pennekam CWA, Immink RV, den Ruijter HM, et al. Near-infrared Spectroscopy to Indicate Selective Shunt Use During Carotid Endarterectomy. Eur J Vasc Endovasc Surg. 2013;46(4):397-403. 4. Zogogiannis ID, Iatrou CA, Lazarides MK, et al. Evaluation of an intraoperative algorithm based on near-infrared refracted spectroscopy monitoring, in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy. Middle East J Anaesthesiol. 2011;21(3):367-73. COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and internationally registered trademarks of Covidien AG. Other brands are trademarks of a Covidien company. 2015 Covidien. 15-PM-0117a