The abbreviated impactor measurement concept

Similar documents
EPAG Sponsored Workshop on Abbreviated Impactor Measurement (AIM) and Efficient Data Analysis (EDA) Concepts in Inhaler Testing. Overview of AIM EDA

Last updated: July 2011

Equivalence Evaluation of Valved Holding Chambers (VHCs) with Albuterol Pressurized Metered Dose Inhaler (pmdi)

Understanding cascade impaction and its importance for inhaler testing

What Do Cascade Impaction Measurements Tell Us: In Vitro Aspects. Context of Presentation

Caption: The equipment required for testing Fluticasone Propionate (FP) Inhalation Powder in line with a new product-specific monograph (USP36-NF31).

Assessing Quality of Inhaled Products And Links to Efficacy and Safety

Inhalation Product Research at FDA

PRACTICES OF COATING COLLECTION SURFACES OF CASCADE IMPACTORS: A SURVEY OF MEMBERS OF THE EUROPEAN PHARMACEUTICAL AEROSOL GROUP (EPAG)

Assessing the role of breathing simulators in OIP testing

INTRODUCTION. size and total nozzle area decrease with stage number. Volumetric air flow rate through

IMPROVING THE REALISM AND RELEVANCE OF MOUTH-THROAT MODELS FOR INHALED PRODUCT TESTING

OVERVIEW OF EFFECTIVE DATA ANALYSIS (EDA)

Characterizing the Performance of Metered Dose Inhalers with Add-On Devices: New Methods For Clinically Relevant Testing

Go With the Flow REGULATORY LANDSCAPE. Mark Copley at Copley Scientific

Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A. Phone: Fax:

EPAG Perspective - Regulatory Advances Related to Nasal Spray Pumps. Dr G.Williams Nasal Drug Delivery Management Forum London, 15 Apr 2010

Testing Inhaled Generics

VARIABILITY IN CASCADE IMPACTION: SOURCES, IMPACT AND STRATEGIES FOR REDUCTION

The Role of EPAG in Standards and Regulatory Guidance Development

Respiratory. Martin Jetzer DDL27 Edinburgh December 2016

University of Groningen. Technology in practice Lexmond, Anne

CLINICAL RELEVANCE OF IN VITRO PARTICLE SIZING DATA. Steve Newman, PhD Nottingham, UK November 2006

Draft Guidance on Fluticasone Propionate; Salmeterol Xinafoate. Fluticasone Propionate; Salmeterol Xinafoate. Powder/Inhalation

Adapting Pharmacopeial Testing for Pharmaceutical Equivalence Studies. Julie D. Suman, Ph.D. March 29, 2016

Optimising the application of in vitro test methods for the demonstration of bioequivalence in orally inhaled products

Device Design Similarity

SELECTION AND VALIDATION OF CASCADE IMPACTOR TEST METHODS

The effect of different coating materials on the prevention of powder bounce in the next generation impactor

AEROSOL THERAPY: THE PRACTICALITIES

COPLEY SCIENTIFIC. Quality Solutions for Inhaler Testing Edition. metered-dose inhalers dry powder inhalers nebulisers nasal sprays

Performance of a Fluticasone Propionate/Salmeterol Xinafoate 3M Taper DPI

Process Drift and it s Resolution in the Manufacture of Drug Products. MDI s and DPI s Metered Dose Inhalations and Dry Powder Inhalations

Lessons Learned from Approval of Generic Nasal Products

Misty Max 10 nebulizer

Metered Dose Inhalers (MDIs) In Vitro Measures to Confirm Patient Perceptions: HFA vs. CFC

MDI. Recommended Equipment

A NEW, ADVANCED HIGH- THROUGHPUT SYSTEM FOR AUTOMATED INHALER TESTING

Implications of the new CHMP Guideline on the Pharmaceutical Quality of Inhalation and Nasal Products

Next Generation Pharmaceutical Impactor (A New Impactor for Pharmaceutical Inhaler Testing). Part I: Design ABSTRACT

COPLEY SCIENTIFIC. Quality Solutions for Inhaler Testing. metered-dose inhalers dry powder inhalers nebulisers nasal sprays

Drug/Device Combination Products: Bioequivalence

COMMENTS. Submitted by The International Pharmaceutical Aerosol Consortium

Understanding Regulatory Global Requirements for Nasal Drug Products. Julie D. Suman, Ph.D. April 8, 2016

Predictive modeling of deposition, dissolution, absorption and systemic exposure

Metered Dose Inhaler Technology

21/03/2011 AEROSOL DEPOSITION AND THE ASSESSMENT OF PULMONARY DRUG DELIVERY. Fundamentals of aerosols

IPAC-RS/UF Orlando Inhalation Conference March 20, S.T. Horhota 1, C.B. Verkleij 2, P.J.G. Cornelissen 2, L. Bour 3, A. Sharma 3, M.

Year in review. Vit Perlik Director of Regulatory Science and Clinical Development

Current Challenges and Opportunities in Demonstrating Bioequivalence

DEBATING THE OPERATING CURVES FOR DDU TESTS ON MARKETED INHALERS

Dry Powder Inhaler. Developing an Efficient. 3M Conix DPI. White Paper / Spring Proven Solutions that Enable Your Success

Qualifying Container Closure Systems for OINDP: Current & Future Regulatory Expectations. Julie D. Suman, Ph.D. November 14, 2014

ISO Process and Standards Under Development. ISO Principles

OPTIMISING ANALYTICAL STRATEGIES FOR THE DEMONSTRATION OF BIOEQUIVALENCE IN A GENERIC NEBULISER

Best Practices for OINDP Pharmaceutical Development Programs Leachables and Extractables

DISSOLUTION TESTING - Exploring the Link Between Particle Size & Dissolution Behavior for OINDPs

Generic Inhaled Medications

Quality of Nasal and Inhalation Drug Products

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

OF COATING MATERIAL ON THE AERODYNAMIC PARTICLE SIZE DISTRIBUTION (PSD) OF OXIS TURBOHALER USING MIXING INLET WITH AN ANDERSEN CASCADE IMPACTOR (ACI)

Effect of Interval Between Actuations of Albuterol Hydrofluoroalkane Pressurized Metered-Dose Inhalers on Their Aerosol Characteristics

Patient. Device Clinician. Safety & efficacy

Nonclinical Safety Evaluation of Inhalation Drug Products

International Pharmaceutical Aerosol Consortium on Regulation and Science

The Use of Physics-Based Modeling to Better Design Drug- Device Interface. Yoen-Ju Son, PhD Merck Research Laboratory, Summit, NJ

Online supplementary material

Use of Math Modelling to Understand Delivery of Biopharmaceutical Molecules to the Lung

FRI aerosol. deposition. A unique way to look at regional inhaled drug deposition.

COMPARISON OF THE RESPIRABLE FRACTION FROM THREE DIFERENT DPI DEVICES

FRI aerosol. deposition. A unique way to look at regional inhaled drug deposition.

Considerations for Evaluation of Bioequivalence and Interchangeability of Orally Inhaled Products

Citation for published version (APA): Westerman, E. M. (2009). Studies on antibiotic aerosols for inhalation in cystic fibrosis s.n.

Lawrence X. Yu, Ph.D. Director (acting) Office of Pharmaceutical Science Food and Drug Administration

Case Study 1: Pharmaceutical Development of EXUBERA

Study designs and PD/Clinical endpoints to demonstrate therapeutic equivalence: European Views

IVIVC in Pediatric OIPs

UPDATE ON THE GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

Original Contributions

Biopharmaceutics of Non-Orally Administrated Drugs

SELECTING A DOSAGE FORM FOR DRUG DELIVERY TO THE LUNGS. Dr. Jay T. Holt, Ph.D., Sr. Director, Inhalation & Analytical

In Vitro Evaluation of Positive Expiratory Pressure Devices Attached to Nebulizers

Everything for Inhalation

First to Market or 505 (b)2 CMC Considerations IPAC-RS/UF Orlando Inhalation Conference Orlando, Florida

Orally Inhaled Corticosteroids to 2022

REDUCING VARIABILITY IN TEST RESULTS FOR OINDPS WITH AUTOMATED ACTUATION

Curriculum Vitae. Doctor of Philosophy, Pharmaceutical Sciences; University of Maryland, Baltimore. MD. University of Pune, India

RDD Europe 2009 Workshop

Technology and Quality of Inhalation Drug Products

FDA Expectations and Evaluation of Inhalation Toxicology Studies

Ensuring the Quality of Some Drug-Device Combination Products - FDA Perspective

Moving to More Realistic In Vitro Testing of OIDPs

ADDITIONAL TECHNOLOGIES FOR PRESSURIZED METERED DOSE INHALERS. Steve Newman Scientific Consultant Nottingham, UK

Challenges in Meeting International Requirements for Clinical Bioequivalence of Inhaled Drug Products

Next Generation Nebuliser Formulations Background

Novel Application of an Old Excipient L-Leucine- Improving Physical and. Aerosolization Stability of Spray Dried Amorphous DPI Formulations.

SELECTING A DOSAGE FORM FOR DRUG DELIVERY TO THE LUNGS

Pulmonary deposition of inhaled drugs

Hydrofluoroalkane- vs Chlorofluorocarbon-Beclomethasone Delivery in Neonatal Models. Tufts University School of Medicine, Boston, MA, and

Understanding the links between drug delivery route and in vitro test methods Mark Copley, Sales Director, Copley Scientific

Transcription:

AS APPEARED IN Inhalation JUNE 2009 www.inhalationmag.com The abbreviated impactor measurement concept A potentially faster and more precise way to assess quality of inhaled drug products Jolyon P. Mitchell, Mark W. Nagel, and Mark Copley Trudell Medical International and Copley Scientific The Quality by Design (QbD) initiative [1] provides a significant opportunity for the pharmaceutical industry to re-appraise how it builds quality into orally inhaled products (OIPs). QbD involves rigorous definition of how critical quality attributes (CQAs) relate to the knowledge, design, and control spaces that map OIP performance [2]. Aerodynamic particle size distribution (APSD) qualifies as a CQA for in vitro inhaler performance because of its relationship with particle deposition in the respiratory tract [3]. APSD measurements, therefore, serve an important purpose in the context of OIP quality control (QC) [4]. However, traditional multistage cascade impaction methods for measuring APSD require a great deal of labor [5], and operator inconsistency can make them subject to measurement variability [6]. Abbreviated testing methods have the potential to alleviate some of these problems, but several past attempts have failed to gain wide acceptance. The Twin Impinger [7] and Fisons 2-stage metal impactor [8] offered the earliest concepts for abbreviated testing and appeared as apparatuses A and B respectively in the European Pharmacopeia up to the 4th Edition (2002). In the mid 1990s, guidance for reducing the 8- stage Andersen Cascade Impactor (ACI) to abbreviated formats for pmdi and DPI assessments [9] appeared, but the regulators were not receptive to reducing size resolution in cascade impactor (CI) measurements at that time [10, 11]. Furthermore, the suggested apparatus configurations proposed at the time lacked theoretical support. The single stage impactor (SSI) option developed in 1997 to validate the time-of-flight-based Aerodynamic Particle Sizer (APS) spectrometer, which arguably qualifies as a two-stage abbreviated impactor, has demonstrated the ability to provide comparable performance with full resolution CIs for a few pmdi-based formulations [12]. However, the SSI works as part of the complete APS package and not as a stand-alone apparatus [13]. In the past year or so, Trudell Medical International and Copley Scientific have developed the abbreviated impactor measurement (AIM) concept as a viable alternative to full resolution cascade impactor (CI) measurement [14]. This new method of abbreviated cascade impaction has demonstrated the potential both to improve decision making in QC and to make the testing process itself more efficient. Theoretical aspects of the AIM concept A typical full resolution multi-stage CI such as the ACI or the Next Generation Pharmaceutical Impactor (NGI) does not represent an analogue of the human respiratory tract [15] due to the fact that regional particle deposition in the respiratory tract does not sharply resolve into multiple size-related fractions. Rather, a CI size fractionates incoming aerosol into discrete size bands that relate to individual stage collection characteristics [16]. On this basis, operators may choose metrics to characterize impactor-measured APSD that optimize precision instead of obtaining full resolution APSD data that likely offers less precision due to stages that collect little active pharmaceutical ingredient (API) [6]. In its simplest form, the AIM concept involves eliminating all stages from a multi-stage CI except those required to establish fine and coarse particle fractions [17] (Fig. 1). Where appropriate, the pre-separator is also included to eliminate over-size particles. AIM testing retains the induction port as specified in the pharmacopoeial methods [16]. By reducing the number of stages, the AIM concept reduces the 7 or 8 data points associated with the typical full resolution APSD to the 2 mass fractions assigned to fine (FPF) and coarse (CPF) particles. Multiplying the total mass captured by the impactor by the FPF gives the fine particle mass (FPM); multiplying total mass by the CPF produces the coarse particle mass (CPM). When the appa-

Figure 1 Impactor-measured APSD fractionated into fine (FPM) and coarse (CPM) components Figure 2 Augmentation of AIM concept to include extrafine fraction ratus includes the induction port and pre-separator, summing the FPM and CPM gives the mass that actually enters the abbreviated impactor. To match the specification provided in the European Pharmacopeia [18], operators can fix the boundary between the two fractions at 5.0 µm aerodynamic diameter. However, for determining product QC, this value does not necessarily have to relate to clinical performance in terms of likely lung deposition location. Indeed, examination of a large database of currently marketed OIP has shown recently that the ratio of CPM/FPM sensitively indicates shifts in APSD [19]. Moreover, this sensitivity increases as the boundary size approaches the mass median aerodynamic diameter (MMAD) for the drug product of interest. Furthermore, the sum of CPM and FPM captures changes in the amplitude of the full resolution APSD that affect the area under the curve when expressed in terms of the differential mass-weighted function i n ([ m i /(CPM FPM]) i 1 versus d ae, where m i is the mass on stage i of an n - stage system [19], a feature independent of sizerelated shifts in APSD. Analysts may also want to incorporate a third subfraction encompassing extra fine particles (EPM) as a refinement (Fig. 2), especially for solution-based pmdi formulations where the bulk of the aerosol entering the CI often approaches 1.0 µm aerodynamic diameter [17]. Although this augmentation provides more information about the overall shape of the APSD, the CPM/FPM ratio provides adequate information by itself, especially with the boundary fixed close to the MMAD for these formulations, so using EPM as a QC metric is unnecessary. The stage grouping method incorporates error associated with each stage into the aggregate API mass assigned to the group, and the stages that collect low amounts of API have a higher variability that adds significantly to the group error [19]. Improvements in measurement precision obtained through AIM should translate into better decision making capability in the QC environment. Despite the potential advantages of AIM-based systems, full resolution APSD measurements still have a role. Complete APSDs provide guidance in product pharmaceutical development and help to rationalize the outcomes of clinical development programs. Furthermore, analysts still need a definitive OIP APSD specification as the benchmark against which to evaluate shifts in CPM/FPM or CPM + FPM in the product QC environment. Experimental aspects Recent reviews of full resolution impactor method variability [5, 6] have highlighted the complexity and difficulty of these measurements, and current experimental proposals are backed by ongoing data-supported theoretical assessments that add necessary rigor to the development of AIM-based methods as practical tools, especially for OIP QC [19]. Manufacturers of CI equipment have begun to develop several different abbreviated systems based on these new studies for users to evaluate [17]. The Fast Screening Impactor (FSI) from MSP Corporation, a 2-stage abbreviated system based on a modified NGI pre-separator, avoids possible pitfalls of AIM equipment created by eliminating compo-

nents from a full resolution CI. Removing those components may simply relocate the typically small internal losses in the abbreviated apparatus that would normally be retained but not accounted for in the full resolution version. A range of inserts for the FSI provides a 5 µm cut-off diameter for flow rates from 30-100 L/min at 5 L/min intervals, achieving this flexibility by varying the nozzle sizes of the single stage impactor contained within the body of the device. Nozzles can also be manufactured to provide other specified cut-off diameters, e.g., 4.7 µm, which corresponds with Stage 2 of the ACI at 28.3 L/min. A filter collector located below the pre-separator body collects the fine fraction. Modifying the NGI by using deep cups to make selected stages non operational can convert it into an abbreviated 2- or 3-stage system. In addition, an insert for the stage 1 nozzle can reduce jet diameter to a desired size limit for the stage cut-point. Alternatively, inserting special exhaust- or inlet-carrying- O -cups in successive stages of the impactor can create an abbreviated NGI [20]. Using a nozzle insert, size fractionation takes place at the first stage, with the coarse fraction captured at that stage and the fine fraction transported via the first exhaust cup to a filter located immediately below. The cleaned gas flow then returns to the NGI via the second exhaust cup. Currently, no data have been published concerning the performance of these abbreviated NGI systems. Some proof of concept data already exists for 2 slightly different 3-stage versions of a short stack ACI, with one study involving dry particles and the other evaporating particles [21-23]. The Fast-Screening Andersen (C-FSA) impactors from Copley Scientific (Fig. 3) are the first abbreviated instruments based on the non-viable ACI. Two recent proof of concept studies using a version of the C-FSA and a similar but slightly modified version of an ACI (the T-FSA) developed at Trudell Medical International focused on pmdi-produced aerosols (Fig. 4). The T-FSA includes a non-operating ACI stage 0 inserted to provide comparable functional dead space before the first size-separating stage. Both studies investigated the potential for non-ideal behavior associated with particle bounce, internal losses and, in the second study, differences in evaporation behavior. The first study evaluated both the C- FSA and T-FSA with pmdi-based formulations, first with a formulation producing dry particles (Flovent- HFA fluticasone proprionate at 125 µg/actuation) and the second involved a formulation containing 8% ethanol (Qvar beclomethasone dipropionate at 100 µg/actuation) producing evaporating particles. Figure 3 Copley C-FSA Figure 4 Trudell version of the FSA with an additional stage to collect extra-fine particles as well as a nonoperating stage 0 to retain similar dead space to full resolution ACI for sampling aerosols containing volatile species

The use of surfactant- or grease-coated collection plates proved essential to minimize particle bounce and re-entrainment (Fig. 5) because the increased inertia of particles that would otherwise be collected by previous stages in the full resolution configuration enhances non-ideal behavior in abbreviated systems. With coated collection plates, both reduced impactors proved substantially equivalent to the full resolution ACI (Fig. 6). Similar behavior will likely occur with other AIMbased systems derived from full resolution CIs by the removal of non-operating stages. Interestingly, the small but measurable wall losses associated with stages in the full ACI that were removed to create the abbreviated designs transferred to the lower stage in the abbreviated impactors, but the effect resulted in only about a 2% increase in EPM. In the follow-on study, the introduction of additional dead space in the T-FSA compared with the C-FSA improved agreement with the ACI in terms of FPM by providing similar conditions for ethanol evaporation (Fig. 7). These validation experiments indicate that both fast screening ACI designs have the potential for use with other pmdi-delivered formulations. Currently, plans are under way within the Impactor Sub-Team of the European Pharmaceutical Aerosol Group (EPAG) to extend the database associated with proving the utility of all types of AIM-based systems with a range of different OIP types. In practice, implementing AIM will necessitate evaluation of the suitability of OIPs on a formulation-byformulation basis with a chosen system to establish substantial equivalency with full resolution (benchmark) CI data. This process, which will likely be essential to achieve regulatory acceptance for routine QC use in production, is best undertaken as a key part of the product development process. References 1. International Conference on Harmonization. (2005), Q8: Pharmaceutical development, ICH, Geneva Switzerland. Available at: www.ich.org 2. Peri, P. Quality by design approaches for orally inhaled and nasal products (OINDPs) in the USA, Dalby, R.N., Byron, P.R., Peart, J. and Suman, J.D. (eds), RDD Europe 2007, Davis Healthcare, River Grove, Illinois, 2007; 59. 3. G. Rudolph, Kobrich, R. and Stahlhofen, W. Modeling and algebraic formulation of regional aerosol deposition in man. J. Aerosol Sci. 1990; 21(S1):S403-S406. 4. Tougas, T., Christopher, D., Lyapustina, S., et al. Capabilities of aerodynamic particle size distribution (APSD) measurements based on analysis of a blinded Figure 5 Collection of FP particles onto uncoated collection plates in the C-FSA Figure 6 Collection of FP particles onto surfactant-coated collection plates in the C-FSA Figure 7 Comparison of C-FSA and T-FSA to ACI for ethanol-containing BDP particles

database. Respiratory Drug Delivery 2008, Davis Healthcare, River Grove, Illinois, 2008; 109-123. 5. Christopher, D., Curry, P., Doub, B., et al. Considerations for the development and practice of cascade impaction testing including a mass balance failure investigation tree. J. Aerosol Med., 2003; 16:235-247. 6. Bonam, M., Christopher, D., Cipolla, D., et al. Minimizing variability of cascade impaction measurements in inhalers and nebulizers. AAPS PharmSciTechnol., 2008;9(2):404-413. 7. Hallworth, G.W, and Westmoreland, D.G. The Twin Impinger: A simple device for assessing the delivery of drugs from metered dose pressurized aerosol inhalers. J. Pharm. Pharmacol., 1987; 39(12):966-972. 8. European Directorate for the Quality of Medicines and Healthcare (EDQM). Preparations for inhalation: aerodynamic assessment of fine particles. Section 2.9.18 - European Pharmacopeia - Apparatus B in versions up to 4th Edn. 2002. Council of Europe, 67075 Strasbourg, France. 9. Van Oort, M. and Roberts, W. Variable flow-variable stage-variable volume strategy for cascade impaction testing of inhalation aerosols. In R.N Dalby, P.R. Byron and S.J. Farr (eds.), Respiratory Drug Delivery-V, Interpharm Press, Buffalo Grove, IL, USA. 1996, 418-420. 10. Byron, P.R., Cummings, R.H., Nichols, S.C., et al. Selection and validation of cascade impactor test methods. Respiratory Drug Delivery-IX, Davis Healthcare, River Grove, IL, USA. 2004, 169-178. 11. US Federal Drug Administration (FDA). Draft guidance: Metered dose inhaler (MDI) and dry powder inhaler (DPI) drug products chemistry, manufacturing and controls documentation. Docket 98D-0997 (1998). 12. Mitchell, J.P. and Nagel, M.W. Time-of-flight aerodynamic particle size analyzers: Their use and limitations for the evaluation of medical aerosols. J. Aerosol Med., 1999;12(4):217-240. 13. Mitchell, J.P., Nagel, M.W., Wiersema, K.J., et al. Aerodynamic particle size analysis of aerosols from pressurized metered-dose inhalers: Comparison of Andersen 8-Stage cascade impactor, Next Generation pharmaceutical Impactor, and model 3321 Aerodynamic Particle Sizer aerosol spectrometer. AAPS PharmSciTechnol. 2003;4(4):Article 54. 14. Mitchell, J.P. The Role of aerosol measurement for aerodynamic particle size distribution (APSD) in a Quality-by-Design (QbD) environment. Davis Healthcare, River Grove, IL, 2008; 779-783. 15. Mitchell, J.P. and Dunbar, C. Analysis of cascade impactor mass distributions. J. Aerosol Med. 2005;18(4):439-451. 16. Mitchell, J.P. and Nagel, M.W. Cascade impactors for the size characterization of aerosols from medical inhalers: Their uses and limitations. J. Aerosol Med. 2003;16:341-377. 17. Mitchell, J.P. The Abbreviated Impactor Measurement (AIM) concept for aerodynamic particle size distribution (APSD) in a quality-by-design (QbD) environment. Proc. Biennial IPAC-RS Conference, Bethesda, MD, USA. 2008. 18. European Directorate for the Quality of Medicines and Healthcare (EDQM) Preparations for inhalation: aerodynamic assessment of fine particles. Section 2.9.18 - European Pharmacopeia: 6th Edn. Council of Europe, 67075 Strasbourg, France, 2009; 287-300. 19. Tougas, T.P., Christopher, D., Mitchell, J.P. et al. Improved methods for detecting differences in aerosol particle size distributions. JAMP 2009; 22(2):169. 20. Svensson, M. AstraZeneca, Lund, Sweden, Private communication, 2008. 21. Mitchell, J.P., Mackay, H., Avvakoumova, V., Ali, R. and Nagel, M. The Abbreviated impactor measurement (AIM) concept: Influence of particle bounce and re-entrainment application to the Copley Fast Screening Andersen Impactor (C-FSA). Drug Delivery to the Lungs 19, The Aerosol Society, Edinburgh, UK, 2008; B30-B33. 22. Mitchell, J.P., Nagel, M.W., Avvakoumova, V., et al. The Abbreviated impactor measurement (AIM) concept: Part 1 Influence of particle bounce and reentrainment evaluation with a dry pressurized metered dose inhaler (pmdi)-based formulation. AAPS PharmSciTechnol. 2009,10(1):243-251. 23. Mitchell, J.P., Nagel, M.W., Avvakoumova, V., et al. The Abbreviated impactor measurement (AIM) concept: Part 2 - Influence of evaporation of a volatile component evaluation with a droplet producing pressurized metered dose inhaler (pmdi)- based formulation containing ethanol as co-solvent. AAPS PharmSciTechnol. 2009, 10(1):252-257. Jolyon P. Mitchell is Scientific Director and Mark W. Nagel is Manager of the Aerosol Laboratory at Trudell Medical International, 725 Third Street, London, Ontario, Canada, N5V 5G4. Tel: +1 519 455-7060. jmitchell@trudellmed.com. Mark Copley is Technical Sales Manager, Copley Scientific, Colwick Quays Business Park, Private Road No. 2, Colwick, Nottingham UK NG4 2JY. Tel: +44 115 961 6229. m.copley@copleyscientific.co.uk