In case of spillage: Absorb with inert material. Collect in closed containers and dispose in accordance with Federal, State and local regulations. Avoid skin contact, wear protective equipment. Waste Disposal: Dispose in accordance with Federal, State, and local regulations. Page1of 1. Chemical Product and Contact Information Product Name: Nano-Bond Adhesive Material Safety Sheet Number: 00183 Date of Issue: 01/22/02 Revision Date: 11/05/09 Company Identification: Pentron Clinical 1717 West Collins Ave. Orange, CA 92867 Phone: 800-551-0283 203-265-7397 Emergency Information Chemtrec: 800-424-9300 Chemtrec International: 202-483-7616 MATERIAL SAFETY DATA SHEET Page 1 of 2 M.S.D.S.#00183 2. Composition/Information on Ingredients 3. Hazard Identification Those people known to be allergic to methacrylate resins should avoid the use of this product. 4. First Aid Measures Contact with eyes: Rinse with plenty of water and consult an opthamologist. Contact with skin: Wash with soap and water. After ingestion: Seek medical attention immediately. 5. Fire Fighting Measures Extinguishing media: CO2, water, dry chemical. Protective equipment: Unknown. 6. Accidental Release Measures 7. Handling and Storage Refrigeration required. Store at 2-8 C. Store away from direct sunlight, initiators, oxidizing, and/or reducing agents. Over time spontaneous polymerization may occur. Chemical characteristics: Methacrylate monomers in Acetone Description: Mixture of PMGDM, a condensation product of PMDA and Glycerol Dimethacrylate HEMA and Dimethacrylates and POSS in ethanol and/or acetone with photo initiator, amine accelerator & stabilizer. Hazardous components: Element CAS # HEMA 868-77-9 N.E. N.E. TMPTMA 3290-92-4 N.E. N.E. PMGDM N.E. N.E. N.E. Photo Initiator System Various N.E. N.E. N.E. N.E. Acetone 67-64-1 2400 1188 Ethanol Poss 64-17-5 01-30-01 1900 1880 Exposure Limit mg/m3 OSHA PEL ACGIH TLV Nano_Bond_Adhesive_MSDS_Web_05J332_Rev07 MATERIAL SAFETY DATA SHEET PagePa2geo1fof2 M.S.D.S.#00183 9. Physical and Chemical Properties Appearance: Form: Liquid. Color: Slight yellow, clear. Odor: Acetone Melting point/melting range: Unknown. Boiling point: Unknown. Flash point: About 101 C. Autoigniton temperature: 360 C. Danger of explosion: Unlikely. Density: 1.0 Vapor Pressure: 184. Viscosity: Unknown. ph: Not applicable. Solubility in/miscibility with:
Water: Yes. Content of resin: >60%. Organic solvents: >20%. Water: 5%. 10. Stability and Reactivity 11. Toxicological Information 12. Ecological Information Unknown. Stability: Stable. Conditions to avoid: Heat, sparks & open flames. Incompatibility: Acids, oxidizing agent, alkalis, amines, ammonia and chlorinated compounds. Carcinogenicity: None of the components of this material are listed by IARC, NTP, OSHA, or ACIGH as carcinogens. TLV: Oral rat 5.2 ml/kg. Primary Routes of entry: Inhalation, skin, and eyes. 13. Disposal Considerations 14. Transport Information 15. Regulatory information 16. Other Information Dispose of in accordance with Federal, State, and local regulations. Not classified as dangerous goods. Unknown. 8. Exposure Controls/Personal Protection Respiratory protection: Face mask recommended for prolonged exposure. Eye protection: OSHA approved goggles. Protective gloves: Yes. The information and recommendations set forth herein (hereinafter "information") are presented in good faith and believed to be correct as of the date hereof. Pentron Clinical however, makes no representations as to the completeness or accuracy of this information and supplies it on the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Pentron Clinical be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.
Personal precautions: Protective gloves, goggles and others are recommended. Environmental precautions: None known. Methods for cleaning up: Collect by mechanical means after binding with absorbing material (saw dust/sand/vermicullite, soda ash, etc.) and dispose appropriately. Remove residues with paper towel. Additional information: Unknown. Page1of 1. Chemical Product and Contact Information Product Name: Nano-Bond Self Etch Primer Material Safety Sheet Number: 00186 Date of Issue: 03/12/02 Revision Date: 11/05/09 Company Identification: Pentron Clinical 1717 West Collins Ave. Orange, CA 92867 Phone: 800-551-0283 203-265-7397 Emergency Information Chemtrec: 800-424-9300 Chemtrec International: 202-483-7616 MATERIAL SAFETY DATA SHEET Page 1 of 2 M.S.D.S.#00186 2. Composition/Information on Ingredients Chemical characteristics: Acidic monomer solution. Description: AMPS and hydrophilic monomers solution. Hazardous components: Ethyl alcohol. 4. First Aid Measures General information: Unknown. After skin contact: Remove with copious amounts of water and paper towel. Consult a physician if irritation occurs. After eye contact: Flush 15 min. with copious amounts of water, an opthamologist is needed. Rinse/flush with alkaline/saline solution under physician care. After swallowing: Consult a physician immediately. Rinse oral cavity with water and exude or expectorate. Induce vomiting. Seek fresh air. Prolonged contact: Eyes, corneal abrasions, skin-oral mucosa - sensitivity, burning sensation, lesions, inflammation and ulcerations. 5. Fire Fighting Measures Extinguishing media: Carbon dioxide, dry chemical powder or appropriate foam. Protective equipment: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes. 6. Accidental Release Measures 7. Handling and Storage Refrigeration required. Store at 2-8 C. Avoid oxidents, acids, alkalies, salt, metals, amines, peroxide catalysts; cap after usage. Avoid skin, mucous membrane, oral mucosa and gingival (gum tissue) contact. Avoid eye contact and ingestion. Ventilation: Yes. Local Exhaust: Yes. Isolation: Goggles, gloves, intraoral rubber dam recommended. Use fresh brush tips for dispensing/application with each patient. Avoid cross contamination. 3. Hazard Identification Avoid eye contact. Severe eye irritation, and possible risk of irreversable damage to the eye may occur after contact. Avoid ingestion/inhalation. Avoid contact with skin, mucous membrane and oral mucosa. Component CAS # Exposure Limit mg/m3 ACGIH TLV OSHA PEL Camphorquinone 10373-78-1 N/E N/E Water 7732-18-5 N/E N/E AMPS 15214-89-8 N/E N/E HEMA 868-77-9 N/E N/E Nano_Bond_SelfEtch_MSDS_Web_05J333_Rev02 MATERIAL SAFETY DATA SHEET PagePa2geo1fof2 M.S.D.S.#00186 9. Physical and Chemical Properties Appearance: Form: Water-like Liquid. Color: Slight yellow. Odor: Ester-like. Information on change in the physical state Melting point/melting range: Not applicable. Boiling point/boiling range: Not applicable. Flash point: Not applicable. Autoignition temperature: Unknown. Danger of explosion: Unlikely. Density: about 1.0 g/cm3.
Vapor pressure: Not applicable. Viscosity: Not applicable. ph: About 1.5. Solubility in/miscibility with: None. Water: Dissolve in water. Content of solvents: 90%. Organic solvents: 1%. Water: >10%. Content of solids: >1%. 10. Stability and Reactivity 11. Toxicological Information 12. Ecological Information General information: Data not available. Classification of water endangerment: Unknown. Incompatibility with other substances: Strong bases, finely powdered metals. Hazardous discomposition products: Smoke, carbon monoxide, and others. Acute toxicity: May be harmful if absorbed through the skin, if swallowed. Material is destructive to the mucous membranes, upper respiratory tract, eyes and skin. TLV: Unknown. Primary Routes of entry: Inhalation, skin, and eyes. 13. Disposal Considerations 14. Transport Information 15. Regulatory information Disposal consideration: Dispose in accordance with Federal, State, and local regulations. Not classified as dangerous goods. Classification according to EEC guidelines: Unknown. National Prescriptions: Unknown. Classification according to VbF: Unknown. The information and recommendations set forth herein (hereinafter "information") are presented in good faith and believed to be correct as of the date hereof. Pentron Clinical however, makes no representations as to the completeness or accuracy of this information and supplies it on the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Pentron Clinical be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS. 16. Other Information 8. Exposure Controls/Personal Protection Personal protective equipment: Wear protective clothing, lab coat, goggles, face mask (inorganic) and gloves. General measure of protection and hygiene: Normal hygienic measures. Respiration: Unknown. Hands: Protective gloves. Eyes: OSHA approved goggles.
In case of spillage: Absorb with inert material. Collect in closed containers and dispose of as recommended. Avoid skin contact, wear protective equipment. Waste Disposal: Dispose in accordance to Federal, State, and local regulations. 1. Chemical Product and Contact Information Product Name: Nano-Bond Dual Cure Activator Material Safety Sheet Number: 00185 Date of Issue: 03/12/02 Revision Date: 11/05/09 Company Identification: Pentron Clinical 1717 West Collins Ave. Orange, CA 92867 Phone: 800-551-0283 203-265-7397 Emergency Information Chemtrec: 800-424-9300 Chemtrec International: 202-483-7616 2. Composition/Information on Ingredients 3. Hazard Identification Those people known to be allergic to methacrylate resins should avoid the use of this product. 4. First Aid Measures Contact with eyes: Rinse with plenty of water and consult an opthamologist. Contact with skin: Wash with soap and water. After ingestion: Seek medical attention immediately. 5. Fire Fighting Measures Extinguishing media: CO2, water, dry chemical. Protective equipment: Unknown. 6. Accidental Release Measures 7. Handling and Storage Refrigeration required. Store at 2-8 C. Store material away from direct sunlight, initiators, oxidizing, and/or reducing agents. Over time spontaneous polymerization may occur. 8. Exposure Controls/Personal Protection Respiratory protection: Face mask recommended for prolonged exposure. Eye protection: OSHA approved goggles. Protective gloves: Yes. Chemical characteristics: Methacrylate initiator in Ethanol and/or Acetone. Hazardous components: Self-curing initiators dissolved in acetone. MATERIAL SAFETY DATA SHEET Page 1 of 2 M.S.D.S. #00185 Element Acetone Benzoyl Peroxide CAS # Exposure Limit mg/m3 67-64-1 94-36-0 2400 5 1188 5 OSHA ACGIH TLV NanoBond_DCA_MSDS_05J334_Rev03 9. Physical and Chemical Properties Appearance: Form: Liquid. Color: Slight yellow, clear. Odor: Acetone and/or alcohol-like. Melting point/melting range: Unknown. Boiling point: Unknown. Flash point: About 101 C. Autoigniton temperature: 360 C. Danger of explosion: Unlikely. Density: < 1. Vapor Pressure: 184. Viscosity: Unknown. ph: Not applicable. Solubility in/miscibility with: Water: Yes. Content of resin: 5%. Organic solvents: 90%. Water: 5%. 10. Stability and Reactivity 11. Toxicological Information 12. Ecological Information
Unknown. Stability: Stable. Conditions to avoid: Heat, sparks & open flames. Incompatibility: Acids, oxidizing agent, alkalis, amines, ammonia and chlorinated compounds. Carcinogenicity: None of the components of this material are listed by IARC, NTP, OSHA, or ACGIH as carcinogens. TLV: Oral rat 5.2 ml/kg. Primary Routes of entry: Inhalation, skin, and eyes. 13. Disposal Considerations 14. Transport Information 15. Regulatory Information 16. Other Information Dispose of in accordance with Federal, State, and local regulations. Not classified as dangerous goods. Unknown. The information and recommendations set forth herein (hereinafter "information") are presented in good faith and believed to be correct as of the date hereof. Pentron Clinical however, makes no representations as to the completeness or accuracy of this information and supplies it on the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. In no event will Pentron Clinical be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information. NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OF ANY OTHER NATURE ARE MADE HEREUNDER WITH RESPECT TO INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS. MATERIAL SAFETY DATA SHEET Page 2 of 2 M.S.D.S. #00185