The clinical use of endosseous implants has

Similar documents
The majority of the early research concerning

Osseointegrated dental implant treatment generally

Evaluation of peri-implant tissue response according to the presence of keratinized mucosa Abstract Purpose: Materials and methods Results:

Endosseous cylindric implants are well accepted

Case study 2. A Retrospective Multi-Center Study on the Spiral Implant

Endosseous dental implants initially showed very

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

The surgical placement of dental implants has

Mechanical and technical risks in implant therapy.

Preliminary Data of a Prospective Clinical Study on the Osseotite NT Implant: 18-month Follow-up

The Brånemark osseointegration method, using titanium dental implants (fixtures)

The Self-tapping and ICE 3i Implants: A Prospective 3-Year Multicenter Evaluation

Contemporary Implant Dentistry

The International Journal of Periodontics & Restorative Dentistry

Consensus Statements and Recommended Clinical Procedures Regarding Loading Protocols

A retrospective study on separate single-tooth implant restorations to replace two or more consecutive. maxillary posterior teeth up to 6 years.

Purpose: To assess the long term survival of sites treated by GTR.

John P. Zarb, BA, DDS George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

Implant osseointegration and successful restoration

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

Narrow-diameter implants in premolar and molar areas

The Use of Alpha-Bio Tec's Narrow NeO Implants with Cone Connection for Restoration of Limited Width Ridges

PALATAL POSITIONING OF IMPLANTS IN SEVERELY RESORBED POSTERIOR MAXILLAE F. Atamni, M.Atamni, M.Atamna, Private Practice Tel-aviv Israel

Rehabilitating a Compromised Site for Restoring Form, Function and Esthetics- A Case Report

Table of Contents. 1 Immediate occlusal loading of NanoTite PREVAIL Implants: A prospective 1-year clinical and radiographic study

The effect of peri-implant bone exposure on soft tissue healing and bone loss in two adjacent implants

During the last 30 years, endosseous oral

Influence of Patient Age on the Success Rate of Dental Implants Supporting an Overdenture in an Edentulous Mandible: A 3-year Prospective Study

Dental Implants: A Predictable Solution for Tooth Loss. Reena Talwar, DDS PhD FRCD(C) Oral & Maxillofacial Surgeon Associate Clinical Professor

Osseointegrated implant-supported

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

Immediate implant placement in the Title central incisor region: a case repo. Journal Journal of prosthodontic research,

The International Journal of Periodontics & Restorative Dentistry

For more than 20 years, the standard protocol for

The influence of radiotherapy on osseointegration

Implant Placement in Maxillary Anterior Region Along with Soft and Hard Tissue Grafting- A Case Report.

Interproximal Papilla Levels Following Early Versus Delayed Placement of Single-Tooth Implants: A Controlled Clinical Trial

NanoTite Tapered Implants: An Implant Designed For Performance. Review And Clinical Results

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

Factors influencing severity of periimplantitis

Esthetic management of multiple missing anterior teeth A Case report

Guided surgery as a way to simplify surgical implant treatment in complex cases

While the protocol for direct bone-to-implant

STABILITY OF IMPLANTS AND NATURAL TEETH MONTHS OF FUNCTION AS DETERMINED BY THE PERIOTEST OVER 60 CLINICAL

A simple approach to preserve keratinized mucosa around implants using a pre-fabricated implantretained stent: a report of two cases

Young-Jin Park, DDS,* and Sung-Am Cho, DDS, MS, PhD

The Influence of Controlled Occlusal Overload on Peri-implant Tissue. Part 3: A Histologic Study in Monkeys

Areview of recent studies concerning molar. Single Molar Replacement with a Progressive Thread Design Implant System: A Retrospective Clinical Report

ADEA COHAEP SYMPOSIA: TURF WARS

The International Journal of Periodontics & Restorative Dentistry

Pouch Roll Technique for Implant Soft Tissue Augmentation: A Variation of the Modified Roll Technique

The Importance of Implant Surface Characteristics in the Replacement of Failed Implants

INTRODUCTION TO DENTAL IMPLANTOLOGY HISTORY OF DENTAL IMPLANTS EUGENIA PROKOPETS, DDS LSU PERIODONTICS

Frequency and Type of Prosthetic Complications Associated with Interim, Immediately Loaded Full-Arch Prostheses: A 2-Year Retrospective Chart Review

Developing Keratinized Mucosa Around Nonsubmerged Dental Implants. Part I: The Use of Vascularized Flaps

Clinical Evaluation of Dental Implants with Surfaces Roughened by Anodic Oxidation, Dual Acid-Etched Implants, and Machined Implants

G03: Complications 12/7/2013 8:00AM 4:30PM

Creating emergence profiles in immediate implant dentistry

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

The restoration of partially and completely

Safety and esthetics with

MULTIDIRECTIONAL APPROACH OF ORAL REHABILITATION WITH IMPLANTS IN A PATIENT WITH LIMITED MOUTH OPENING: A CASE REPORT

Don t Let Life Pass You By Because Of Oral Bone Loss

Early Loading of Osseotite Implants 2 Months After Placement in the Maxilla and Mandible: A 5-year Report

A Long-term Retrospective Analysis of Survival Rates of Implants in the Mandible

Since the early 1980s, when the concept of

AO Certificate in Implant Dentistry Certificate

1- Implant-supported vs. implant retained distal extension mandibular partial overdentures and residual ridge resorption. Abstract Purpose: This

JMSCR Vol 06 Issue 07 Page July 2018

CHAPTER 1. General Introduction

Computer-guided minimally invasive

Flapless, Immediate Implantation & Immediate Loading with Socket Preservation in the Esthetic Area Using the Alpha-Bio Tec's NeO Implants

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

Please visit the C.E. Pavilion to validate your course attendance Or If There s a Line Go cdapresents.com


م.م. طارق جاسم حممد REMOVABLE PARTIAL DENTURE INTRODUCTION

The Endodontic / Implant Controversy

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Surgery All at Once : Socket preservation and immediate placement of an implant in an infected site in the anterior region a Case Report

Evidence-based decision making in periodontal tooth prognosis

Vertical and Horizontal Augmentation Using Guided Bone Regeneration. Ph.D. Thesis. Dr. med. dent. et univ. Istvan Urban

Mandibular implant-supported hybrid prostheses

This Presentation Is Trademarked by Lawrence H. Zager, D.D.S.

Controlling Tissue Contours with a Prosthetically Driven Approach to Implant Dentistry

Implants- immediate restoration of postextraction edentation both esthetically and functionally

SPECIAL SUPPLEMENT. Inside this issue: 2014 No. 3. Peri-implant disease Implant surface: An evolution Summaries of select scientific publications

Practical Advanced Periodontal Surgery

Dentatus ANEW Narrow Diameter Implants. Expanding Implantology with More Treatment Options

Hiron Andreaza da Cunha, MS 1 /Carlos Eduardo Francischone, DMD 2 /Hugo Nary Filho, DDS 3 / Rubelisa Cândido Gomes de Oliveira, BDS 4

Implant Site Development Part I

Long-term success of osseointegrated implants

The International Journal of Periodontics & Restorative Dentistry

Successful osseointegration of implants has been

Many of the problems reported by conventional

Overcoming and Preventing Dental Implant Complications: Abutment Fracture Case Report

Pressure Necrosis And Osseointegration: An Editorial White Paper*

Module 2 Introduction to immediate full arch fixed implant treatment - surgical options

Ankylos. Scientific Summary

More than pure esthetics. The natural and strong solution.

Transcription:

A Prospective Multicenter Clinical Trial of 3i Machined-Surface Implants: Results After 6 Years of Follow-up Dietmar Weng, DDS, Dr Med Dent 1 /Zhimon Jacobson, DDS 2 /Dennis Tarnow, DDS 3 / Markus B. Hürzeler, DDS, Dr Med Dent, PhD 4 /Ove Faehn, DDS 5 / Farshid Sanavi, DMD, PhD 6 /Pål Barkvoll, DDS, PhD 7 /Renée M. Stach, DDS 8 Purpose: In this prospective multicenter clinical study, 1,179 3i standard threaded and self-tapping implants were followed for up to 6 years and monitored according to established success criteria. Materials and Methods: A total of 493 patients (240 men and 253 women) with a mean age of 45.1 years at implant surgery were enrolled at 6 research centers after being screened for exclusion criteria. Implants were placed according to a 2-stage surgical protocol with a minimum of 4 months of submerged healing in the mandible and 6 months in the maxilla. Restorations included 633 prostheses, the majority of which were fixed partial dentures in the posterior mandible or maxilla or single-tooth replacements in the anterior maxilla. Results: One hundred four implants (8.8%) did not meet success criteria and were designated as failures, and 222 implants (18.8%) were lost to follow-up. The cumulative success rate according to life table methods was 91.1% at 6 years. Discussion: Sixty percent of the failed implants were short ( 10 mm long), and their cumulative success rate as a group at 6 years was 89.0%, compared to 93.1% for longer implants (P.05). Thirty-three percent of all failures were implants placed in the posterior maxilla, for a 5-year cumulative success rate of 87.4%. Conclusion: It appears that limited bone dimensions and poor-quality bone have an impact on the performance of these machined-surface implants. (INT J ORAL MAXILLOFAC IMPLANTS 2003;18:417 423) Key words: bone quality, clinical trial, endosseous dental implants, surface properties 1 Associate Professor, Department of Prosthodontics, School of Dental Medicine, Bavarian Julius-Maximilians-University of Würzburg, Germany. 2 Professor, Boston University School of Graduate Dentistry, Boston, Massachusetts. 3 Associate Professor and Chairman, Department of Implant Dentistry, College of Dentistry, New York University, New York, New York. 4 Private Practice, Institute for Periodontology and Implantology, Munich, Germany. 5 Private Practice, Oslo, Norway. 6 Clinical Associate Professor and Director of Periodontal Graduate Clinic and Implant Clinic, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania. 7 Professor and Head, Department of Oral Surgery and Oral Medicine, University of Oslo, Norway; Chairman, Institute of Clinical Dentistry, University of Oslo, Norway. 8 Medical Writer, Clinical Research Department, Implant Innovations, Palm Beach Gardens, Florida. Reprint requests: Dr Dietmar Weng, Department of Prosthodontics, School of Dental Medicine, Bavarian Julius-Maximilians-University of Würzburg, Pleicherwall 2, 97070 Würzburg, Germany. Fax: +49-931-20173000. E-mail: dietmar.weng@mail.uni-wuerzburg.de The clinical use of endosseous implants has enriched the therapeutic spectrum of restorative dentistry like few other innovations in the last century. Since the introduction of the first welldocumented implant system, 1 many others have followed, exhibiting similar as well as different material properties and design features. Because of the steadily increasing number of implant restorations, the necessity has emerged to establish objective, system-independent criteria for defining long-term success of dental implants. The search for such criteria was first initiated at the National Institutes of Health Harvard Consensus Development Conference in 1978. 2 The currently accepted and established criteria are based on a series of other proposals for implant success criteria 3,4 and were subsequently refined and reinforced in the Toronto Consensus Report in 1998. 5 To be considered successful, an implant must meet the following requirements 5 : The International Journal of Oral & Maxillofacial Implants 417

Fig 1 1. The resultant implant support does not preclude the placement of a planned functional and esthetic prosthesis that is satisfactory to both patient and dentist. 2. There is no pain, discomfort, altered sensation, or infection attributable to the implants. 3. Individual unattached implants are immobile when tested clinically. 4. The mean vertical bone loss is less than 0.2 mm annually following the first year of function. The objective of this study was to evaluate the long-term performance of 3i standard threaded and self-tapping implants (Implant Innovations, Palm Beach Gardens, FL). The following is the first description of a prospective clinical trial on 3i machined-surface implants with well-defined success criteria over an observation time of up to 6 years. MATERIALS AND METHODS The 3i self-tapping implant. Six research centers (5 university clinics and 1 private clinic) located in the United States (3 institutions) and in Europe (3 institutions) participated in this prospective, multicenter clinical trial. Patients had to be able to tolerate conventional surgical and restorative procedures and had to be willing and able to comply with all aspects of the treatment and follow-up schedule. The patients health status was evaluated in a preoperative screening. Presence of 1 or several of the following conditions, determined either by direct examination or historical documentation, was reason for exclusion from the study: alcoholism or drug abuse, mental illness, evidence or suspicion of unwillingness to comply with longterm follow-up, uncontrolled diabetes, hemophilia, metabolic bone disorder, history of renal failure, corticosteroid treatment, anticoagulant therapy, radiation treatment to the head or neck, previous bone graft at the intended site, current chemotherapy, untreated or uncontrolled periodontal pathology, current pregnancy at the time of evaluation, and severe bruxing or clenching habits. The test designs to be implanted in the patients were 3i standard threaded implants and 3i self-tapping implants (Fig 1). These implants feature a machined surface and an external hexagon. The lengths (7, 8.5, 10, 13, 15, and 18 mm) and diameters (3.25, 3.75, 4, 5, and 6 mm) of the individual implants varied from subject to subject, depending on the bone width and depth at each site. To standardize surgical procedures, all centers were equipped with the same surgical drill units, handpieces, and surgical instruments. Furthermore, study monitors assessed and reviewed all surgical procedures to ensure intercenter reliability. The implants were placed according to the manufacturer s guidelines in a 2-stage process to guarantee complete bony fixation before loading. Concomitant hard tissue grafting or augmentation procedures precluded inclusion in the study. At the time of surgery, the clinical assessment of bone quality was recorded based on hand-felt perception of the drilling resistance and categorized into 1 of 3 classes of bone quality. Bone quality was scored by the clinician as dense, normal, or soft. Surgical uncovering of the implants was done after a healing period of 4 months in the mandible and 6 months in the maxilla. During soft tissue healing after stage 2 surgery, fabrication of the prosthetic restorations was completed. At the time of prosthesis placement, baseline measurements were obtained. They consisted of clinical and radiographic parameters and were repeated at 6 months, 1 year, 18 months, and 2, 3, 4, and 5 years after prosthesis placement. Clinical parameters included the assessment of: Individual and unattached implant mobility, as determined by the lateral application of pressure by 2 opposing instruments to the implant Probing depths at mesial, distal, buccal, and lingual sites, ie, distance in mm between the mucosal margin and the bottom of the probable pocket with a non-standardized periodontal probe; care was taken not to disturb any soft tissue attachment Peri-implant mucosal health at 4 sites, including gingival levels, amount of keratinized gingiva, amount of recession, gingival inflammation, and presence of hyperplastic mucosa or suppuration 418 Volume 18, Number 3, 2003

Table 1 Distribution of Implants by Study Center No. of No. of No. of No. of Failure rate Center patients restorations implants placed implant failures by center 1 47 64 160 18 11% 2 126 133 267 24 9% 3 116 144 274 22 8% 4 48 77 149 14 9% 5 70 85 85 3 4% 6 86 130 244 23 9% Totals 493 633 1179 104 8.82% In measuring gingival levels, a standard reference point was established from which measurements were made in millimeters, ie, the implant/abutment interface. All measurements apical to the reference point were expressed as negative numbers; all coronally oriented measurements were reported as positive numbers. Gingival inflammation was categorized by severity using the following scale: 0 = no inflammation, 1 = mild inflammation (color change only), 2 = moderate inflammation (bleeding upon probing), and 3 = severe inflammation (spontaneous bleeding). Radiographic parameters were obtained from periapical and panoramic radiographs made at baseline, 6 months, and 1, 2, 3, 4, and 5 years and included mesial and distal bone level measurements as well as descriptions of peri-implant radiolucencies. Acquisition of periapical radiographs was standardized by use of a customized template fabricated at the time of prosthesis placement. Bone level measurements estimated to the nearest 0.01 mm were performed by 1 calibrated examiner on serial radiographs according to standard operating procedures. Average mesial and distal bone level measurements were calculated for all implants. The mean implant value was the average of the mean mesial and distal measurements. Bone loss was the difference in bone level measurements from the baseline established at prosthesis loading compared to each follow-up evaluation. In addition to the surgical and implant measurements, prosthodontic parameters were assessed at follow-up evaluations. Categories rated by the clinicians on a scale from 1 to 4 included prosthesis retention, prosthesis stability, esthetics, and phonetics. The Cornell Medical Index 6,7 was used to evaluate patient satisfaction in the categories comfort, fit, speech, appearance, ability to chew, ability to taste, and general satisfaction. Each category was graded as 1 (excellent), 2 (good), 3 (fair), or 4 (poor). Changes in medical status and disclosure of new adverse events (unanticipated negative effects, eg, implant failure, fracture of implant components) were also recorded at each recall visit. In this study an implant was considered successful If it was immobile when tested individually and unattached to other implants In the absence of peri-implant radiolucency While no persistent or irreversible signs and symptoms such as pain, discomfort, altered sensation, or infection attributable to the implant were observed If there was loss of marginal bone crestal levels no greater than 0.2 mm per year after the first year of function If the resultant implant support did not preclude the placement of a planned functional and esthetic prosthesis that was satisfactory to both patient and the investigator Implants were classified as successful, failed, or censored (eg, not used as a result of death, buried because of poor position for restoration, or if the patient was lost to follow-up) and analyzed by survival analysis distribution according to life table methods. RESULTS A total of 493 patients 240 men (49%) and 253 women (51%) with a mean age of 45.1 ± 15.1 years were enrolled in the study across 6 investigational centers. Of these, 78 (16%) were smokers and 1% had diabetes. A breakdown of enrollment by center is included in Table 1. A total of 1,179 implants were placed in the 493 patients. The diameters and lengths of implants used in this study are described in Table 2. The majority of implants (61.8%) were 3.75 mm in diameter. Of the implants placed, 48.5% were short in length, ie, 10 mm or less. Five hundred nine (41.4%) of the implants were placed in the maxilla and 972 (79.1%) in premolar or molar areas of the mandible or the maxilla. Two hundred seventy-four (23.2%) were located in the posterior maxilla The International Journal of Oral & Maxillofacial Implants 419

Table 2 Length and Diameter Distribution of Implants Implant length (mm) Implant diameter (mm) 7.0 8.5 10.0 13.0 15.0 18.0 20.0 Total 3.25 0 0 2 33 30 0 0 65 3.75 7 11 275 242 175 17 1 728 4.00 0 1 10 8 4 0 0 23 5.00 11 47 144 75 0 0 0 277 6.00 9 11 44 22 0 0 0 86 Total 27 70 475 380 209 17 1 1179 Percent of implants placed 75 50 25 0 Maxillary implants Mandibular implants Total Anterior Posterior Percent of restorations 70 60 50 40 30 20 10 0 Single-tooth replacement Short-span fixed prostheses ( 5 units) Long-span fixed prostheses ( 5 units) Fig 2 Proportion of implants placed by location. Fig 3 Distribution of prosthetic restorations. Percent cumulative success Fig 4 95 90 85 18 months 80 0 10 20 30 40 50 60 70 Life table distribution for all implants. (Fig 2). One hundred eighty-three (15.6%) implants were placed in bone described as dense, 816 (69.5%) in normal bone, and 175 (14.9%) in soft bone. Altogether, 633 prostheses were placed in the 493 patients. Distribution of these 633 prostheses can be seen in Fig 3. A majority of restorations (371, or 59%) were fixed partial dentures in the posterior areas of the mandible or the maxilla, followed by 253 (40%) single-tooth replacements, and a few long-span fixed prostheses (1%). The results of gingival assessments (gingival levels, keratinized gingiva, probing depths, and gingival inflammation) indicated that peri-implant mucosa maintained good health throughout the follow-up period, with only slight changes from baseline. Stable marginal crestal bone levels were observed throughout the follow-up period, with a mean bone loss of 0.67 mm between loading and 4- year evaluations. This report provides an interim analysis after a mean observation time of 72.0 ± 6.4 months after implant placement. Mean elapsed time from implant placement to stage 2 surgery was 6.8 months and from implant placement to loading was 15.5 months. Of the implants characterized as successful, 80.5% reached the 5-year evaluation time point. One hundred four implants (8.8%) did not meet success criteria and were designated as failures, and 222 implants (18.8%) were lost to follow-up. Reasons for loss to follow-up were death, geographic relocation, and economic reasons. Eight hundred fifty-three of the surviving 957 implants were considered successful according to the aforementioned 420 Volume 18, Number 3, 2003

Fig 5 Prosthetic outcomes for all restorations, as rated by clinicians. 0 months = Prosthetic loading date. Good 2.0 1.8 1.6 1.4 1.2 Excellent 1.0 Rating Retension Stability Esthetics Phonetics 0 3 6 12 18 24 36 48 Fig 6 Cornell Medical Index of patient satisfaction as scored by patients. 0 months = Prosthetic loading date. 1.4 1.2 Excellent 1.0 0 3 6 12 18 24 36 48 Comfort Fit Speech Appearance Ability to chew Ability to taste General satisfaction Percent cumulative success 95 90 85 All implants Short implants Implants in posterior maxilla Short implants in posterior maxilla Percent cumulative success 95 90 85 80 75 10 mm (n = 475) 8.5 mm (n = 70) 7 mm (n = 27) 80 0 10 20 30 40 50 60 70 70 0 20 40 60 Fig 7 Life table distribution for implants by length and location. Fig 8 Life table distribution for short implants by individual length. criteria. The cumulative success rate according to life table methods was 91.1% at 5 years post-loading, and the survival distribution is illustrated in Fig 4. Most implant failures (87, or 83.7%) occurred prior to prosthesis placement (ie, loading), and only 12 failures occurred 18 months post-prosthesis placement. Most of the 104 implants designated as failures were subsequently removed. The reasons for failure were mobility (84), continuous radiolucency (20), persistent pain (20), persistent signs of infection (14), violation of the mandibular canal (1), and/or other (11). Prosthetic outcomes and patient satisfaction with their prostheses were favorable and are illustrated in Figs 5 and 6. The type of occlusion observed for most prostheses was group function or anterior disclusion. Most clinicians rated the retention, stability, esthetics, and phonetics of the prostheses as excellent or good. Sixty percent of all failed implants were short ( 10 mm), and the cumulative success rate for these short implants was 89.0%, a significantly lower rate than the cumulative success rate for all implants of 91.1% (Fig 7). Failure of the short implants included 26% of 7-mm implants, 19% of 8.5-mm implants, and 9% of 10-mm implants (Fig 8). The International Journal of Oral & Maxillofacial Implants 421

Another group of implants that failed at a relatively higher rate were those placed in the posterior maxilla. These constituted 33% of all failures with a cumulative success rate at 5 years of 87.4% (Fig 7). DISCUSSION A major reason for the success of dental implants has been the development of implant designs and surgical procedures that result in a direct boneimplant interface that can be stable long term. This condition is generally referred to as osseointegration. It is achieved by careful control of the conditions of treatment, notably atraumatic surgical preparation of the implant site by the use of copiously irrigated drilling at low speed and high torque under aseptic conditions, use of biocompatible implant materials such as titanium, and the imposition of a healing period during which no load is placed on the implant. 8 Osseointegration is characterized by immobility of the implant, lack of radiolucency around the implant, and the absence of soft tissue between bone and the major portion of the implant surface on histologic examination. 9 Stable osseointegration can be considered a criterion of implant success, and the parameters established in the present study for implant success served to determine the existence of osseointegration. Since the initiation of this study, implant designs have evolved to include surface modifications with greater roughness that act to not only anchor the implant more firmly in the bone soon after placement, but also to promote better clot retention and bone regeneration. 10 Prospective clinical studies have shown that an implant with a dual acid-etched surface performs at a high success rate. 11 14 While the 1,179 machined-surface implants in the present long-term study showed a cumulative success rate of 91.1%, which falls within the guidelines for implant success of at least 85% at 5 years 3 and is similar to success rates reported for other machined-surface implants, 15 they did not achieve success rates as high as the more recently manufactured acid-etched implants. Because of the large number of implants in the current study, an attempt at failure analysis is possible. As can be seen from the Fig 4 life table distribution, there was a consistent decline in the cumulative success rate, and after 18 months the curve flattened out into a steady state with fewer failures. With respect to implant dimensions and locations, it appears that short implants ( 10 mm) failed at a higher rate than longer implants. This is also consistent with the findings of other clinical reports on machined-surface implants. The failure rate of these short implants increased as the length of the implant decreased. The cumulative success rate for the short implants was 88.7% at 6 years, which includes a 26% failure of 7-mm implants. In comparison, the 5-year cumulative success rate for long implants was 93.1%. Frequently, short implants are placed where there are inadequate bony dimensions and the bone tends to be of a softer clinically assessed quality, such as in the posterior maxilla where space is limited by the maxillary sinus. Implants are at greater risk in areas of the jaw where bone density is often quite low, the bone height is reduced, and functional load is high. In this report there was a greater percentage of implant failures in the posterior maxilla, where a cumulative success rate of 86.2% was achieved for 274 implants. One third of all implant failures were those implants placed in the posterior maxilla, where 27.4% of the implants were placed in bone described as soft, which is almost twice the frequency of soft bone for all implants. Furthermore, for the short implants placed in the posterior maxilla the success rate was only 80.6%, perhaps indicating the contribution of implant length and bone quality to clinical outcomes. It appears that the limitations of bone dimensions and more common occurrence of poor-quality bone had an impact on the outcome of machined-surface implants placed in the posterior maxilla. Another observation regarding the failure pattern in this study was that 95.2% of all implant failures (ie, 99 of 104) occurred within the first 3 years after implant placement. This finding is consistent with another study of machined-surface implants, 16 in which 97.9% of the failures occurred before the third year of follow-up (274 out of 280). Lindh and coworkers 17 conducted a meta-analysis of implants in partially edentulous patients. In 19 studies with a total of 2,686 predominantly machined-surface implants, 95.3% of all failures were recorded within 3 years after implant loading. These failure patterns seem to support the US Food and Drug Administration s recent proposal 18 to change the clinical follow-up period of root-form endosseous implants for Premarket Approval Applications from 5 to 3 years, at least as far as machined-surface implants are concerned. CONCLUSION Survival analysis indicated that after 6 years of follow-up, 3i machined-surface implants achieved a cumulative success rate of 91.1% in this patient population. Short implants failed at a higher rate (11.0%) than longer implants (6.9%), and more failures were located in the posterior maxilla (33% of 422 Volume 18, Number 3, 2003

all failures). Additional analyses of this data set will be published in subsequent manuscripts. ACKNOWLEDGMENTS This study was supported by Implant Innovations, Palm Beach Gardens, Florida. REFERENCES 1. Brånemark P-I, Hansson B-O, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1 132. 2. Schnitman PA, Shulman LB. Recommendations of the Consensus Development Conference on Dental Implants. J Am Dent Assoc 1979;98:373 377. 3. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11 25. 4. Albrektsson T, Isidor F. Consensus Report of Session V. In: Lang NP, Karring T (eds). Proceedings of the 1st European Workshop on Periodontology. London: Quintessence, 1993: 365 369. 5. Zarb GA, Albrektsson T (eds). Consensus report: Towards optimized treatment outcomes for dental implants. Int J Prosthodont 1998;11:389. 6. Monroe RT, Whiskin FE, Bonacich P, Jewell WO. The Cornell Medical Index questionnaire as a measure of health in older people. J Gerontol 1965;20:18 22. 7. Cheraskin E, Ringsdorf WM, Setyaadmadja AT, Barett RA. Predictive dentistry: The Cornell Medical Index health questionnaire (general response) and dental findings. NY J Dent 1967;34:104 107. 8. Adell R, Lekholm U, Brånemark P-I. Surgical procedures. In: Brånemark P-I, Zarb GA, Albrektsson T (eds). Tissue- Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago: Quintessence, 1985:211 232. 9. Brånemark P-I. Introduction to osseointegration. In: Brånemark P-I, Zarb GA, Albrektsson T (eds). Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago: Quintessence, 1985:11 76. 10. Davies JE. Mechanisms of endosseous integration. Int J Prosthodont 1998;11:391 401. 11. Sullivan DY, Sherwood RL, Porter SS. Long-term performance of Osseotite implants: A 6-year clinical follow-up. Compend Contin Educ Dent 2001;22:326 333. 12. Grunder U, Gaberthuel T, Boitel N, et al. Evaluating the clinical performance of the Osseotite implant: Defining prosthetic predictability. Compend Contin Educ Dent 1999; 20:629 640. 13. Lazzara RJ, Porter SS, Testori T, Galante J, Zetterqvist L. A prospective multicenter study evaluating loading of Osseotite implants two months after placement: One-year results. J Esthet Dent 1998;10:280 289. 14. Testori T, Wiseman L, Woolfe S, Porter SS. A prospective multicenter study of the Osseotite implant: A four-year interim report. Int J Oral Maxillofac Implants 2001;16: 193 200. 15. Esposito M, Hirsch J-M, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. Eur J Oral Sci 1998;106:527 551. 16. Albrektsson T, Dahl E, Enbom L, et al. Osseointegrated oral implants: A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. J Periodontol 1988;59: 287 296. 17. Lindh T, Gunne J, Tillberg A, Molin M. A meta-analysis of implants in partial edentulism. Clin Oral Implants Res 1998; 9:80 90. 18. U.S. Food and Drug Administration: Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Abutments; Draft Guidance for Industry and FDA. http://www.fda.gov/cdrh/ode/guidance/ 1389.html The International Journal of Oral & Maxillofacial Implants 423