QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only

Similar documents
QUICK REFERENCE INSTRUCTIONS For use with Sofia only.

QUICK REFERENCE INSTRUCTIONS

Sofia Influenza A+B FIA

Next Generation Rapid Diagnostics

Sofia Lyme FIA. For use with Sofia Analyzer only CLIA Complexity: Moderate for serum and plasma specimens

FOR USE WITH SOFIA AND SOFIA 2. For in vitro diagnostic use only. The Sofia Lyme FIA may be used with Sofia or Sofia 2.

For use with Sofia 2 CLIA Complexity: Waived for Finger-stick Whole Blood

FOR USE WITH SOFIA. For in vitro diagnostic use.

Influenza A & B Screening

contact your Medicare and B viral directly from samples. viruses: A, B,

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

Rapid Detection FAQs

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

Human Influenza A (Swine Flu) Rapid test

For use with Sofia only

Rapid-VIDITEST. Influenza A+B

NEPHROCHECK Liquid Control Kit Package Insert

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

Rapid-VIDITEST Swine Flu

CLIA Waived for swab samples Non-Waived for Nasal Aspirate/Wash and swabs stored/transported in media.

CLIA Complexity: Waived

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Rapid-VIDITEST. Influenza A

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

AVIAN INFLUENZA COMMODITIES TRAINING GUIDE MODULE 3 - SAMPLING, RAPID TESTING AND PACKAGING PARTICIPANT HANDOUTS

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

Hepatitis C Virus (HCV) Antibody Test

NEPHROCHECK Liquid Control Kit Package Insert

CLIA Complexity: WAIVED INTENDED USE SUMMARY AND EXPLANATION

NEPHROCHECK Calibration Verification Kit Package Insert

G1 - Specimen collection

Helicobacter pylori Antigen Test

Sulfamethazine Test Kit 20 Tests

CLIA Complexity: WAIVED

Chlamydia trachomatis (CHLa)Test Kit

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

Merry Christmas! Faith makes all. Hope makes all. Love makes all. things possible, things work, things beautiful,

Catalog # 0W009 0W010 Test Cassettes, murine monoclonal antibody to human IgG (Test Line) and rabbit polyclonal antibody (Control Line)

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

Rapid-VIDITEST. Astrovirus Card

TB LAM Ag Lateral Flow Assay Standard Operating Procedure

NEGATIVE POSITIVE. Rev , 06/11. 5 min. Mono Test. For fi ngertip. blood: 1 DROP 1 DROP For serum, whole blood. plasma or. samples.

Unigold Recombigen HIV 1/2 Training for HIV Testing Sites. Updated: February 2018 Cicely Richard Office of HIV/AIDS

CDIA TM Rubella IgG/IgM Rapid Test Kit

NexScreen Cup. Urine Drug Screen * READ POLICY PRIOR TO STARTING TUTORIAL

Strep-a-Test Twister Test

Catalog # 0W009 0W010 Test Cassettes, murine monoclonal antibody to human IgG (Test Line) and rabbit polyclonal antibody (Control Line) Reagents

Malaria Pf/pan antigen Rapid Test

Tips for Training New Customers

Management of Central Venous Access Devices. Blood Glucose Monitoring

PROCEDURE. Sekisui Diagnostics OSOM ifob Rapid Test. Title: Procedure #: Institution: Prepared by: Date: Title: Accepted by: Date adopted: Title:

Abbott PXP Glucose Meters Resource: Lin Gustafson, MT(ASCP) Point of Care Coordinator, Laboratory

Lilly. Disposable Insulin Delivery Device User Manual

HAV IgM Rapid Test(Cassette)

RG12T. For In Vitro Diagnostic Use. Passive Particle-Agglutination Test for Detection of Antibodies to HTLV-

SAMPLE PROCEDURE 907-9, 06/11

Mono Test 1 DROP 1 DROP. For fingertip blood: For serum, plasma or whole blood samples in tubes: Rev , 05/09

Rubella Latex Agglutination Test

Dear HighQ Check System Owner :

HBeAg and HBeAg Ab ELISA Kit

Rapid-VIDITEST. Strep A Card. One step Strep A Card for the detection of Group A Streptococcal antigen from throat swabs or culture.

Rapid-VIDITEST. Rota-Adeno Blister. One Step Rotavirus and Adenovirus Antigen Blister test. Instruction manual

GeneXpert HIV-1 Quantitative assay Natasha Samsunder

Rapid-VIDITEST. Strep A Blister. One step Strep A Blister for the detection of Group A Streptococcal antigen from throat swabs or culture.

CLIA Complexity: WAIVED

Product Training & Certification

PROCEDURE MANUAL. Procedure: CLIA Complexity: Waived for Whole Blood, Moderate for Serum, Plasma. Prepared By Date Adopted Supersedes Procedure #

WHO Prequalification of Diagnostics Programme PUBLIC REPORT

FOR INFORMATIONAL USE ONLY

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

TITLE: Whole Blood Glucose Monitoring Using the Nova StatStrip Meter

CMV FEP ALA For nucleic acid amplification of CMV DNA and Fluorescence detection with End Point analysis (FEP) on Aladin (Sacace)

Fraser Health Authority Accu-chek Inform II: Training Script

Human HBcAb IgM ELISA kit

Instructions For Use. SOLUTION FOR INJECTION IN PRE-FILLED PEN 250 micrograms

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

Influenza A IgG ELISA

Human Cytomegalovirus IgM ELISA Kit

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

CLIA Complexity for Whole Blood: WAIVED. Intended Use. Summary and Explanation

INSTANT-VIEW H. pylori Rapid Test CLIA WAIVED Test for Whole Blood QUALITATIVE IN-VITRO DIAGNOSTIC TEST FOR EXTERNAL USE ONLY

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

PROCEDURE MANUAL. Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

Standard Operating Procedure

1. Intended Use New Influenza A virus real time RT-PCR Panel is used for the detection of universal influenza A virus, universal swine Influenza A vir

i-stat CHEM8 + Cartridge Quick Reference Guide

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

DiagCORE Respiratory Panel 2. Instructions for use PL /2018-EN

Title/Description: Point of Care Glucose Testing-Waived Department: Organization Wide Personnel: All Effective Date: November 29, 2016 Revised:

Procedure for Blood Analysis. 1.0 Purpose - This procedure specifies the methods for performing blood analysis in forensic casework.

Treponema Pallidum (TP) Antibody Test

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

Protn-Latex. For Determination of Protein in Latex. (Cat. # Latex, Latex) think proteins! think G-Biosciences

ifob Test Rev. P5576-A, 04/16 5. Read the result in 5-10 minutes. RESULTS AFTER 10 MINUTES. Important: DO NOT READ

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Transcription:

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only Test Procedure Study the Package Insert and User Manual thoroughly before using Quick Reference Instructions. This is not a complete Package Insert. CLIA Complexity: Waived for direct nasal swab, nasopharyngeal swab and nasopharyngeal aspirate/wash specimens CLIA Complexity: Moderate for nasopharyngeal swab and nasopharyngeal aspirate/wash specimens eluted in transport media IMPORTANT! Read instructions carefully before beginning. The test procedure below is unique to the Sofia Influenza A+B FIA and may differ from other Sofia FIA procedures. NOTE: The procedures for testing swab specimens versus liquid specimens in viral transport media are different. Read carefully. All specimens must be at room temperature before testing. Expiration date: Check expiration date on each individual test package or outer box before using. Do not use any test past the expiration date on the label. Swab Test Procedure (Nasal/Nasopharyngeal) Verify that Sofia or Sofia 2 is set to the desired Mode: WALK AWAY or READ NOW. See the Using Sofia or section for more information. Dispense all of the Reagent Solution into the Reagent Tube. Swirl the Reagent Tube to dissolve its contents. Place the patient swab sample into the Reagent Tube. Roll the swab at least 3 times while pressing the head against the bottom and side of the Reagent Tube. Roll the Swab head against the inside of the Reagent Tube as you remove it. Dispose of the used Swab in your biohazard waste. Fill the provided Small, Clear 120 µl Fixed Volume Pipette with patient sample from the Reagent Tube. To fill the Fixed Volume Pipette with the patient sample: a) FIRMLY squeeze the top bulb. b) Still squeezing, place the Pipette tip into the sample. c) With the Pipette tip still in the sample, release pressure on bulb to fill the Pipette. Firmly squeeze the top bulb to empty the contents of the Small, Clear 120 µl Fixed Volume Pipette into the Test Cassette sample well. Extra liquid in the overflow bulb is OK. NOTE: The Fixed Volume Pipette is designed to collect and dispense the correct amount of patient sample. Discard the Pipette in your biohazard waste. NOTE: Do not pour sample from the Reagent Tube. Use the provided Small, Clear 120 µl Fixed Volume Pipette. Proceed to the Using Sofia or section to complete the test. 120 µl Pipette

Liquid Specimens Test Procedure Verify that Sofia or Sofia 2 is set to the desired Mode: WALK AWAY or READ NOW. See the Using Sofia or section for more information. Dispense all of the Reagent Solution into the Reagent Tube. Swirl the Reagent Tube to dissolve its contents. Fill the provided Large, Pink 250 µl Fixed Volume Pipette with patient sample from the collection cup. To fill the Fixed Volume Pipette with the sample: a) FIRMLY squeeze the top bulb. b) Still squeezing, place the Pipette tip into the patient sample. c) With the Pipette tip still in the patient sample, release pressure on bulb to fill the Pipette. NOTE: To obtain accurate results, avoid mucoid substances when filling the Large, Pink 250 µl Fixed Volume Pipette with patient sample from the collection cup. Firmly squeeze the top bulb to empty the contents of the Large, Pink 250 µl Fixed Volume Pipette into the Reagent Tube. Extra liquid in the overflow bulb is OK. NOTE: Once the sample is added to the Reagent Tube, vigorously mix prior to adding the sample to the Test Cassette. NOTE: The Fixed Volume Pipette is designed to collect and dispense the correct amount of patient sample. Discard the Pipette in your biohazard waste. Fill the provided Small, Clear 120 µl Fixed Volume Pipette with patient sample from the Reagent Tube. Firmly squeeze the top bulb to empty the contents of the Small, Clear 120 µl Fixed Volume Pipette into the Test Cassette sample well. Extra liquid in the overflow bulb is OK. NOTE: Do not pour sample from the Reagent Tube. Use the provided Small, Clear 120 µl Fixed Volume Pipette. Proceed to the Using Sofia or section to complete the test. 250 µl Pipette 250 µl Pipette 120 µl Pipette

Using Sofia WALK AWAY/READ NOW Modes Refer to the Sofia User Manual. Sofia may be set to two different modes (WALK AWAY and READ NOW). The procedures for each mode are described below. WALK AWAY Mode In WALK AWAY Mode, the user immediately inserts the Test Cassette into Sofia. Sofia will automatically time the test development, and the results will be displayed in 15 minutes. READ NOW Mode Allow the test to develop for the FULL 15 minutes BEFORE placing it into Sofia. The user places the Test Cassette onto the counter or bench top for 15 minutes (outside of Sofia). The user manually times this development step. The Test Cassette MUST remain on the bench for 15 minutes to get an accurate result. Then, the user inserts the Test Cassette into Sofia. In READ NOW Mode, Sofia will scan and display the test result in 1 minute. Note: Results will remain stable for an additional 15 minutes after the recommended development time of 15 minutes. RUN TEST 1. Input the User ID with the barcode scanner or enter the data using the key pad. NOTE: If you scan the wrong barcode, use the Arrow Keys on Sofia to re-highlight the field and simply rescan using the correct barcode. The previous one will be overwritten with the right barcode. 2. Input the Patient ID or Order # with the barcode scanner or enter the data using the key pad. 3. Press Start Test and the Sofia drawer will open. 4. Verify that the correct mode (WALK AWAY or READ NOW) has been selected. Insert the Test Cassette into the drawer. Then gently close the drawer. 5. Sofia will start automatically and display the progress. In WALK AWAY Mode, the test results will be displayed in approximately 15 minutes. In READ NOW Mode, the test results will be displayed in 1 minute. See Sofia Interpretation of Results section.

Sofia Interpretation of Results When the test is complete, the results will be displayed on the Sofia screen. The results can be automatically printed on the integrated printer if this option is selected. Test Lines will not be visible to the naked eye. Results: The Sofia screen will display results for the procedural control as being valid or invalid. If the control is invalid, retest with a new patient sample and new Test Cassette. Reader Display Positive Negative Valid Negative Positive Valid Positive Positive Valid Negative Negative Valid Invalid Invalid Invalid Interpretation Positive Test for Flu A (influenza A antigen present) Positive Test for Flu B (influenza B antigen present) Positive Test for both Flu A and Flu B (influenza A and B antigen present) Negative Test for Flu A and Flu B (no antigen detected) Result Invalid Sofia External Quality Control (External Positive and Negative Swabs are supplied in the kit) From the main menu, select Run QC. Follow the prompts on the screen. Scan the QC Card (located on the kit box). Sofia prompts the user to select the desired mode (WALK AWAY or READ NOW). Run the External Control Swabs. Follow the Swab Test Procedure of this Quick Reference Instructions. First test the Positive Swab, followed by the Negative Swab. After both the Positive and Negative Swabs have been run, the results will be displayed as Passed or Failed.

Using Sofia 2 WALK AWAY/READ NOW Modes Refer to the Sofia 2 User Manual. Sofia 2 may be set to two different modes (WALK AWAY and READ NOW). The procedures for each mode are described below. WALK AWAY Mode In WALK AWAY Mode, the user immediately inserts the Test Cassette into Sofia 2. Sofia 2 scans the Test Cassette periodically during the test development time. Positive test results will be displayed between 3 and 15 minutes. Negative test results will be displayed at 15 minutes. READ NOW Mode Allow the test to develop for the FULL 15 minutes BEFORE placing it into Sofia 2. The user first places the Test Cassette onto the counter or bench top for 15 minutes (outside of Sofia 2). The user manually times this development step. The Test Cassette MUST remain on the bench for 15 minutes to get an accurate result. Then, the user inserts the Test Cassette into Sofia 2. In READ NOW Mode, Sofia 2 will scan and display the test result within 1 minute. Note: Results will remain stable for an additional 15 minutes after the recommended development time of 15 minutes. RUN TEST 1. Input the User ID with the integrated barcode scanner or manually enter the data using the key pad. NOTE: If you scan the wrong barcode, re-highlight the field using the touchscreen on Sofia 2. The previous one will be overwritten with the right barcode. 3. Verify that the correct mode (WALK AWAY or READ NOW) has been selected. Press and open the Sofia 2 drawer. 4. Insert the Test Cassette into the drawer. Then gently close the drawer. 2. Input the Patient ID and Order # (if applicable) with the integrated barcode scanner or manually enter the data using the key pad. 5. Sofia 2 will start automatically and display the progress. In WALK AWAY Mode, the test results will be displayed in approximately 15 minutes. In READ NOW Mode, the test results will be displayed within 1 minute. See Sofia 2 Interpretation of Results section.

Sofia 2 Interpretation of Results When the test is complete, the results will be displayed on the Sofia 2 screen. Test Lines will not be visible to the naked eye. Results: The Sofia 2 screen will display results for the procedural control as being or. If the control is, retest with a new patient sample and new Test Cassette. Reader Display Interpretation Positive Test for Flu A (influenza A antigen present) Positive Test for Flu B (influenza B antigen present) Positive Test for both Flu A and Flu B (influenza A and B antigen present) Negative Test for Flu A and Flu B (no antigen detected) Result Invalid Sofia 2 External Quality Control (External Positive and Negative Swabs are supplied in the kit) From the main menu, select Run QC. Follow the prompts on the screen. Scan the QC Card (located on the kit box). Sofia 2 prompts the user to select the desired mode (WALK AWAY or READ NOW). Run the External Control Swabs. Follow the Swab Test procedure of this Quick Reference Instructions. First test the Positive Swab, followed by the Negative Swab. After both the Positive and Negative Swabs have been run, the results will be displayed as or. INTENDED USE The Sofia Influenza A+B FIA employs immunofluorescence to detect influenza A and influenza B viral nucleoprotein antigens in direct nasal swab, nasopharyngeal swab, and nasopharyngeal aspirate/wash specimens and nasopharyngeal swab and nasopharyngeal aspirate/wash specimen in transport media from symptomatic patients. This qualitative test is intended for use as an aid in the rapid differential diagnosis of acute influenza A and influenza B viral infections. The test is not intended to detect influenza C antigens. A negative test is presumptive and it is recommended these results be confirmed by viral culture or an FDA-cleared influenza A and B molecular assay. Negative results do not preclude influenza virus infections and should not be used as the sole basis for treatment or other patient management decisions. The Sofia Influenza A+B FIA may be used with Sofia or Sofia 2. Reference the Package Insert for Warnings and Precautions, Specimen Collection and Handling, and Quality Control. ASSISTANCE If Sofia, Sofia 2 or the assay do not perform as expected, contact Quidel Technical Support 800.874.1517 (in the U.S.), 858.552.1100 (outside the U.S.), technicalsupport@quidel.com, or your local distributor. Study the Package Insert and User Manual thoroughly before using Quick Reference Instructions. This is not a complete Package Insert. Quidel Corporation San Diego, CA 92121 USA quidel.com 1219205EN00 (06/17)