Diffusers Beam Splitters Refractive Microlens Arrays

Similar documents
Diffractive Optic Elements (DOE)

XF Microlens Optic and XD Microlens Compression Optic for Non-Ablative Fractional Skin Treatment with the Palomar Icon System

Mona SC-2 Ultra Pulse Co2 Fractional laser system. Beijing Sanhe Beauty S & T Co.,Ltd

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

Improvement of Column Spacer Uniformity in a TFT LCD Panel

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

Supporting Information

Supplementary Figure 1. Sample preparation schematic. First (Stage I), square islands of MoO 3 are prepared by either photolithography followed by

Exceptional versatility without compromise

Er:YAG Laser-in-Handpiece

Warranty. Any attempt by an unauthorized person to alter or repair the product is also not covered by the warranty.

Automated Fusion Splicing of Circular and D-shaped Fiber with Elliptical Core

Microtubule Teardrop Patterns

aberration induced by laser

LENS PROTECTIVE WINDOWS Issue 1. Intelligent Solutions, Manufacturing & Development

Cornea/Anterior Segment OCT. User Experience

Stress Wave Focusing Transducers

MULTIDIODE PDT 630 TM

RayOne Trifocal IOL. The preloaded platform that performs again and again MADE IN UK

(2) A response is caused when information in the nervous system reaches an effector. the two different types of effector

Round Duct Slot Diffusers Model SKD-13

Straight Through Hole Drilling in Machinable Ceramics

ACOUSTORAPHY Acousto-Optical (AO) Ultrasonics & Its Applications

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

LASIK. Lens. Cornea. Iris. Vitreous. Macula. Retina

Sulcoflex Trifocal Supplementary IOL. When expectations and outcomes align. An elegant solution for the correction of presbyopia MADE IN UK


Icon specifications. Handpiece compatibility

VisuMax from ZEISS Defining the pulse rate in refractive surgery

CATARACT SURGERY GUIDE

Linkam Scientific Instruments

OFFICE DIAL BEZEL, 18" With brass liner, 18" flange and fitted glass. Screw on with four quarter point

Calibration Standards

Real Time 2D Ultrasound Camera Imaging: A Higher Resolution Option to Phased Array Bob Lasser Randy Scheib Imperium, Inc.

Our Mission. Our intention is to work in partnership with our dealers and dentists to help build a better business. talking business and Dentistry

Real-Time Intraoperative Fluorescence Imager for Microscopic Residual Tumor in Breast Cancer

Scrub In. What is the function of vitreous humor? What does the pupil do when exposed to bright light? a. Maintain eye shape and provide color vision

SAXS on lipid structures

Optical cochlear implant project

High Grade Universal Testing Machines

SCLERAL CONTACT LENSES 1. EPSILON SCLERAL

GAFCHROMIC MD-55 RADIOCHROMIC DOSIMETRY FILM FOR HIGH-ENERGY PHOTONS CONFIGURATION, SPECIFICATIONS AND PERFORMANCE DATA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ilearnalignment Training topics covered in the introduction and master versions

Ultrasound & Laser Therapy

Custom-Made Products / Scientific Research Instruments

HEINE Dermatoscopes. Magnification Magnification x 40x* (digital)

Evaluation of handles in a maximum screwdriving torque task

PATIENT COUNSELING. 1

Ophthalmology. Caring For Your Eyes. Jurong Medical Centre

RLE (Refractive Lens Exchange)- Bootcamp. Christopher Blanton, MD April 28,2018

Investigation of Near Field Transducer for HAMR Application

Saratov, Russia September 24, 2015

Comparison of the visual outcomes of abifocal refractive versus atrifocal diffractive IOL

:- HEINE EN 100 Diagnostic Centre

SpiderX. Portable Residual Stress X-Ray Diffractometer.

M & T srl. medical & technology

7. Sharp perception or vision 8. The process of transferring genetic material from one cell to another by a plasmid or bacteriophage

Preparation of Cholesteryl Ester Liquid Crystals

Keratoconus Clinic. Optometric Co-management Opportunities

Fee $20 $30 $60 $35 $65 $55 $45 $15 $30. Fee $55 $75 $85 $105 $60 $80 $115 $80 $105 $140 $170 $875 $135 $155 LENS OPTIONS. Fee $500 $600 $700

Diabetes Eye Q Quiz. 1) Diabetes is the leading cause of new blindness among adults in the US under the age of 74.

Cataract Surgery Patient Information

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

stock catalog food Excellence is in the details.

Far. Intermediate. Near. The first trifocal

Assistive Technology for Early Intervention

Handheld optical coherence tomography device for photodynamic therapy

Welcome to the Future of Dental & Vision Benefits Today!


10 Years Experience in Industrial Phased Array Testing of Rolled Bars

Isometric view Scale 3:1. Scale 1:1. QTR sensor

Laser Effects on Skin Melanin

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

Recent Progress in Vacuum Photon Detectors at Hamamatsu

Ultrasonic arrays are now widely used in underwater sonar

Presentation Product & clinics

Multifocal Toric Swiss Army Knife For the Cataract and Refractive Surgeon

Device Equivalence Evaluation Form

Neptune Brick Red Bank. Ralph G. Del Negro, DO

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

Corporate Medical Policy

FineVision lets you look at the world with a fresh pair of eyes. Learn how you can enjoy the freedom of vision without spectacles.

iflap Intralase Facts

MultiPulse PRO - CO 2 Laser -

Successful Splicing Made Easy

have more than two decades of experience in the field of manufacturing, supplying and exporting a wide range of surgical and medical hospital

SCLERAL CONTACT LENSES EPSILON SCLERAL

SOLASE DENTAL DIODE LASER

Biocard. 1. Troponin I

CoolTouchCTEV. Endovenous 1320nm Laser Treatment for Varicose Veins

Veridiam Tissue Arrayer

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

Innovative NDT Solutions. Ultrasonic Sensor Technology Phased-Array Search Units. An AREVA and Siemens company

Cataract and Refractive Surgery Patients: Still Two Different Breeds?

ophthalmoscopy seeing the eye from greek: ophthalmos - the eye skopeos to see

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

PRK Wavefront Guided idesign Photorefractive Keratectomy

PIEZOTRANSDUCERS WITH ACOUSTIC LENSES FORMING NARROW WEAKLY DIVERGING ULTRASONIC BEAMS

Transcription:

Stock Products Diffusers Beam Splitters Refractive Microlens Arrays For Custom Designs, Prototypes, or Production Quantities Contact Us Directly: MEMS Optical, Inc. 205 Import Circle Huntsville, AL 35806 Tel: (256) 859-1886 Fax: (256) 859-5890 Email: info@memsoptical.com Web: www.memsoptical.com

Diffractive Micro Optics Diffusers and Beam Splitters Our diffractive optic diffuser and beam splitter will convert your beam to any shape. Most standard items are available in acrylic and fused silica for immediate shipping. If you can t find what you need in our selection, we can design and manufacture a custom pattern for you. Diffractive Micro Optics Multifunction Micro Optics Diffuser Stock Items Unmatched Values High Volume Custom Designs High Performance APPLICATIONS Beam Splitter Scanning Systems Sensors LIDAR Laser Radar Applications Diffuser Lithography Exposure Tools Laser Machining Laser Sensors Communications

Stock Fused Stock Silica Diffusers Micro Lens Array Part # Material Shape (Horizontal) (Vertical) Note: FS = Fused Silica (Glass) and PL = Plastic (Acrylic / Polycarbonate) = degrees Line Width D001 FS, PL Rectangle 5 3.3 - D002 FS, PL Rectangle 5 3.6 - D003 FS, PL Rectangle 5 3.9 - D004 FS, PL Scope 10 10 0.4 D005 FS, PL Rectangle 5 4.3 - D006 PL Scope 10 10 0.2 D007 FS, PL Scope 5 5 0.4 D008 FS Scope 5 5 0.2 D009 FS, PL Scope 2 2 0.3 D010 FS Scope 2 2 0.1 D011 FS, PL Scope 1.1 1.1 0.2 D012 FS, PL Rectangle 5 3.1 - D013 FS, PL Crosshair 10 10 0.9 D014 FS, PL Crosshair 10 10 0.4 D015 FS Crosshair 10 10 0.2 D016 FS, PL Crosshair 5 5 0.9 D017 FS, PL Crosshair 5.1 5.1 0.4 D018 PL Crosshair 5 5 0.2 D019 FS, PL Crosshair 1 1 0.4 D020 FS Crosshair 1 0.9 0.2 D021 FS, PL Rectangle 2 1 - D022 FS, PL Rectangle 5 2.5 - D023 FS, PL Rectangle 10 5 - D024 FS Rectangle 20 10 - D025 FS Rectangle 20 14.8 - D026 FS Rectangle 15 11.2 - D027 FS Rectangle 10 7.4 - D028 FS, PL Rectangle 5 3.8 - D029 FS, PL Rectangle 2 1.5 - D030 FS Rectangle 1 0.9 - D031 FS Rectangle 14.8 11.9 - D032 FS, PL Rectangle 13.1 8 - D034 FS Square 19.4 - - D035 FS Square 14.7 - - D036 FS Square 9.9 - - D037 FS Square 5 - - D038 FS, PL Square 2 - - D039 FS, PL Square 1 - - D040 FS, PL Square 0.5 - - D041 FS, PL Ellipse 9.9 2 - D042 FS, PL Ellipse 9.9 5 - D043 FS Round 28.2 - - D044 FS Round 19.3 - -

Stock Diffusers Part # Material Shape (Horizontal) (Vertical) Note: FS = Fused Silica (Glass) and PL = Plastic (Acrylic / Polycarbonate) = degrees Line Width D045 FS Round 14.7 - - D046 FS Round 9.8 - - D047 FS Round 5 - - D048 FS, PL Round 2 - - D049 FS Round 1 - - D050 FS, PL Round 0.5 - - D051 FS, PL Lines (1) 10-1 D052 FS Lines (1) 14.8-0.9 D053 FS, PL Lines (100) 14.4 14.4 0.1 D054 FS Lines (50) 11.4 11.4 0.1 D055 FS Lines (50) 14.2 14.2 0.2 D056 FS Lines (25) 10.7 10.7 0.2 D057 FS Lines (25) 8.6 8.6 0.2 D058 FS, PL Lines (10) 6.7 6.7 0.4 D059 FS, PL Lines (10) 5 5 0.2 D060 FS Lines (1) 14.8-0.2 D061 FS Grid (99x99 square) 21.4 21.4 0.1 D062 FS Grid (49x49 square) 21.4 21.4 0.1 D063 FS, PL Grid (24x24 square) 14.1 14.1 0.2 D064 FS, PL Grid (24x24 square) 10.6 10.6 0.2 D065 FS, PL Grid (24x24 square) 6.5 6.5 0.1 D066 PL Grid (9x9 square) 15 15 0.1 D067 FS, PL Grid (9x9 square) 5 5 0.2 D068 FS, PL Grid (9x9 square) 2.7 2.7 0.1 D069 FS, PL Rectangle 5 3.5 - D070 FS, PL Ring/Concentric (24) 21-0.2 D071 FS, PL Ring/Concentric (10) 9.7-0.2 D072 FS, PL Ring/Concentric (9) 9.9-0.2 D073 FS, PL Ring (1) 11.4-0.7 D074 FS, PL Ring (1) 10.3-0.2 D075 FS, PL Ring (1) 5.4-0.2 D076 FS, PL Rectangle 5 3.2 - D077 FS, PL Rectangle 5 4.2 - D078 FS, PL Rectangle 5 4.5 - D079 FS, PL Ring/Concentric (25) 11.3-0.1 D080 PL Ring (1) 1.4-0.2 Logo Diffuser Diffractive Structure

Stock Beam Splitters Part # Material Number of Spots Note: FS = Fused Silica (Glass) and PL = Plastic (Acrylic / Polycarbonate) = degrees Efficiency 1003 FS Line 4 6.9 70 % 1004 FS Line 4 3.5 70 % 1005 FS Line 5 1.6 78 % 1006 FS, PL Line 5 0.8 78 % 1009 FS Line 7 1.1 80 % 1010 FS Line 7 0.9 80 % 1011 FS Line 8 2.7 74 % 1012 FS Line 8 1.4 74 % 1013 FS, PL Line 9 1.6 72 % 1015 FS Line 10 3.5 74 % 1016 FS Line 10 1.7 74 % 1017 FS Line 15 2.7 72 % 1019 FS Line 16 5.6 77 % 1020 FS, PL Line 16 2.9 77 % 1021 FS, PL Line 31 7.9 81 % 1023 FS, PL Cross 5 4.6 64 % 1025 FS Cross 9 3.1 71 % 1026 FS, PL Cross 9 1.6 71 % 1027 FS Cross 17 6.1 66 % 1028 FS Cross 17 3.1 66 % 1029 FS, PL Circle 8 6.1 63 % 1030 FS Circle 8 3.3 63 % 1031 FS Circle 16 7.7 42 % 1032 FS Circle 16 3.8 42 % 1033 FS Scope 32 7.6 61 % 1034 FS Box 16 3.1 68 % 1035 FS Box 16 1.6 68 % 1036 FS Star of David 12.6 48 % 1037 FS Malcom Cross 3 66 % 1038 FS French Cross 5.4 67 % 1039 FS Bow Tie 5.3 63 % Scope Pattern Beam Split Into 16 Components With Center Spot Crosshair Diffuser Passed Through a Beam Splitter

Stock Stock Fused Silica Microlens Lens Arrays Finest Quality Microlens Arrays Available! Microlens arrays are a vital part of today s optical systems. From telecommunications to machine vision, microlenses are impacting the way we live. Our refractive microlens arrays are some of the best performing optics on the market. If our stock microlens arrays do not meet your requirements, we will design a unique custom solution to meet your specifications. Applications Aspherical Shapes Increase Fill Factor Short Distant Image Relay Diode Array Prototypes Mass Production Limited Aspherical Shape Control Positive & Negative Arrays Two Optical Powers

Stock Microlens Arrays Lens Shape Circular Square Cylindrical Hexagonal Part # Pitch Sag Focal Length Radius of Curvature Fill Factor Circular Shape, Square Packing, 5 um Gap Between Lenses 3006 50 10.1 62.39 28.7 3007 75 19.6 99.3 45.7 68% 3008 100 20.7 153.8 70.7 71% 3011 250 22 795.9 366.1 75% Square Shape, Square Packing, 5 um Gap Between Lenses 3018 50 10.4 179.78 82.7 3019 75 20.8 96.1 44.2 87% 3023 250 22.6 776.1 357 96% Cylindrical Shape, Square Packing, 2 um Gap Between Lenses 3026 15 6.9 16.4 7.5 87% 3028 25 7.9 30.1 13.8 92% 3029 30 8.2 38.7 17.8 93% 3030 50 8.94 64.57 29.7 Cylindrical Shape, Square Packing, 5 um Gap Between Lenses 3034 200 16.6 602.4 277.1 98% Hexagonal Shape, Hexagonal Packing, 5 um Gap Between Lenses 3042 50 10.5 64.57 29.7 3044 100 20.9 152.7 70.3 90% Circular Shape, Hexagonal Packing, 2 um Gap Between Lenses 3054 50 10.4 61.3 28.2 Circular Shape, Hexagonal Packing, 5 um Gap Between Lenses 3055 75 19.6 99.3 45.7 59% 3056 100 20.6 154.3 71 61% 3058 200 21.6 526.7 242.3 65% Notes: Focal lengths are based on 550 nm wavelength. Part size is 10 mm square by 1 mm thick. Dimensions in microns. Material fused silica. Array Output