GLASS EXPANSION NEWSLETTER

Similar documents
Evaluating the performance of the OneNeb Series 2 Nebulizer with PerkinElmer Optima 7/8x00 Series ICP-OES systems

Determination of Copper in Green Olives using ICP-OES

US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Considerations when Analyzing Real-World Samples by ICP Spectrometry

Low-Pressure Chromium Speciation in P2O5 using the Spectro ARCOS MV ICP and the ESI SC-DX chromfast System

Savillex Technical Note

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES

Savillex Technical Note

Savillex Technical Note

Analysis of trace elements in nutraceuticals in compliance with USP chapter <2232> Elemental Contaminants in Dietary Supplements

ICP-OES/ICP-MS SUPPLIES & ACCESSORIES

Trace Metal Characterization of Soils Using the Optima 7300 DV ICP-OES

Determination of available nutrients in soil using the Agilent 4200 MP-AES

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

Application note. Determination of metals in soil by microwave plasma - atomic emission spectrometry (MP-AES) using DTPA extraction.

Selection and Optimization of the Sample Introduction System

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

AVIO 200 ICP-OES CONSUMABLES AND SUPPLIES. Consumables and Supplies Reference Guide

Ordering Information You may contact us via phone, fax, , or through our website.

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

G C6 C8. Considerations when Analyzing Real-World Samples by ICP Spectrometry. Dates and Events. In this issue:

STANDARD SAMPLE INTRODUCTION

Technology offer: High efficiency sample introduction nebulizer

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

MULTI-COMPONENT ANALYSIS OF HEAVY METALS

Innovations for ICP-OES & ICP-MS

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

Ordering Information You may contact us via phone, fax, , or through our website.

ICP-OES Organics Kit Installation Instructions

Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially- Viewed Plasma

Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially-Viewed Plasma

Forensic Analysis of Blood Alcohol Concentration

Approaches to Maximize Performance and Reduce the Frequency of Routine Maintenance in ICP-MS

of applications concentric Nebulizers for a wide variety Nebulizers MeiNHard Nebulizers MicroMist Nebulizers seaspray Nebulizers

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Ordering Information You may contact us via phone, fax, , or through our website.

The first MR with IQ. Philips Intera 1.5T With SmartExam

Determination of Amantadine Residues in Chicken by LCMS-8040

Analysis of Milk for Major and Trace Elements by ICP-MS

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

New Products for Volume 28

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Edgar Naegele. Abstract

COIL PROCESSING SOLUTIONS

Reliable, flexible & precise

Guidelines for Trouble Shooting and Maintenance of ICP-OES Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager

GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7

Agilent 7700x ICP-MS

Determination of metals in industrial wastewaters by microwave plasmaatomic emission spectrometry

INTERCHANGEABLE HEAD SYSTEM. Easily and quickly change between caries diagnosis and intraoral imaging. T r i t o n H D

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

More structural information with MS n

The majority of inductively coupled

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

NOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment

Contour Your Body Quickly and Comfortably!

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections

SECTIOn 3. Multi-Element ClP Standards for ICP & ICP-MS

Solutions at GE Inspection Technologies

Elemental Scientific. seafast S2. Elution Profiles. Elemental Scientific

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

LC-MS/MS Method for the Determination of Tenofovir from Plasma

MINISTAR DIGITAL AND CONTROL /// The new compact stirrers

AK 200 S AK 200 ULTRA S. A better way to better care

Guidelines for Troubleshooting and Maintenance of AA Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager

InTouch Center Local Customer Teams InTouch Agreements Parts Support

The New 6495 Triple Quadrupole LC/MS

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

Case Study. Complex Components Demand Innovative Ultrasound Solution

Agilent 1260 Infinity Analytical SFC System

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Comparison of a UPLC Method across Multiple UHPLC Systems

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

ASCO Power Control Systems Overview

QuickSplitTM Flow Splitters

USP <232> and <233> Understanding Your Path to Compliance with the New Elemental Impurity Chapters. Steve Wall Agilent Technologies

EDXRF APPLICATION NOTE

Join the mass movement towards mass spectrometry

Analysis of Organic Fertilizers for Nutrients with AAnalyst 800 Atomic Absorption Spectrophotometer

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

ACTIVITY SCANNER NEW. 3D Dental Scanner made in Germany.

Guidelines for Troubleshooting and Maintenance of ICP-MS Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Fibertec 1023 Dietary Fibre Solutions

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Pipeline Technology Conference 2007

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Transcription:

GLASS EXPANSION NEWSLETTER Quality By Design C Glass Expansion 2 February 2 CONTENTS Page Application Spotlight Improving the Performance of ICP Spectrometers... New Products PFA Spray Chamber for ICP-MS... PFTE Spray Chamber for ICP-OES... Niagara Rapid Rinse Accessory with Serial Communication... Instrument News From Agilent Technologies - Two new ICP-MS Educational Aids... From Teledyne Leeman - Measure Nitrogen by ICP-OES... From Spectro - A Sidelong Glance Into the Plasma... From Thermo - The World's Smallest ICP... Glass Expansion News New 2 Catalog Now Available... Website in Italian... Pittcon... APPLICATION SPOTLIGHT Improving the Performance of ICP Spectrometers INTRODUCTION This application note is based on a poster paper that was presented at the 2 Winter Conference on Plasma Spectrochemistry. The paper was authored by Jerry Dulude of our US office along with Vesna Dolic and Dr. Peter Liddell of our Australian office and was entitled, Approaching a Universal Pneumatic Nebulizer. As instrumentation for ICP-AES and ICP-MS spectrometry has evolved over the past 3 years, different 7 7 7 manufacturers have standardized on different operating conditions for the nebulizer. This is partly due to the implementation of a wide variety of sample introduction components during the development and maturation of the technology. Each specific choice was optimized with a unique combination of gas and liquid flows and pressures. These conditions were then generally passed on to newer models of spectrometer and sample introduction components were designed to accommodate the preset conditions. Today, many of the instrument manufacturers have standardized on concentric glass nebulizers used in conjunction with a cyclonic spray chamber. Companies such as Glass Expansion, who provide nebulizers customized for each manufacturer s make and model, have responded by designing specific nebulizers designed to run optimally under widely different conditions. For example, our nebulizers are manufactured to operate under any combination of the conditions shown in Table. Our investigation hinges on the theory that there is one optimal argon pressure that can be used to design a universal nebulizer that will perform optimally on all spectrometer systems when used with a cyclonic spray chamber. Based on this hypothesis, we developed a batch of nebulizers based on our successful SeaSpray design, and which were designed to run at pressure,.7l/min Ar flow and 2mL/min natural sample uptake. These nebulizers were tested at uptake rates of and 2.mL/min. This report compares the performance of these new nebulizers with the standard nebulizers for two separate ICP-AES systems. Table. Range of Nebulizer Conditions Available from Glass Expansion NEW 2 CATALOG Argon pressure (psi) Argon flow (L/min) Sample uptake (ml/min) 27 3 3 4 4.7.7....2.. 2. 3. To receive your personal copy, please send an email with your mailing address to enquiries@geicp.com. Glass Expansion Newsletter - February 2 - Page

EXPERIMENTAL The test nebulizers were operated with a Tracey cyclonic spray chamber. This system was evaluated with a Varian MPX Axial and a Perkin-Elmer Optima 2 Dual-View ICP- AES Spectrometer. Instrumental parameters were as shown in Table 2. VARIAN RESULTS Inter-nebulizer Reproducibility To determine the effects of subtle changes in parameters, it is necessary to first establish the inter-nebulizer variability within a given design. Figure demonstrates the internebulizer variability for a group of different psi nebulizers of the same configuration at two different sample uptake rates. (Results reflect the average of the same group of element lines used throughout the study and listed in Figure 3.) The consistent performance across the five nebulizers is due to the unique construction of the VitriCone sample channel in which a heavy glass capillary is machined to very tight tolerances. Note that even though the uptake rate has been decreased by a factor of, emission intensity counts are decreased by only about 2 to 2%. This is due to the much higher efficiency produced at lower uptake rates. Performance Results Figures 2 through 4 compare the performance of the nebulizers with the standard nebulizers on the Varian instrument for a range of element lines. The data in Figure 2 demonstrates that the nebulizer increased the sensitivity by 8% on average. It is believed that the increased gas pressure resulted in a smaller mean droplet size in the primary aerosol which in turn caused a significant enhancement in transport efficiency (tertiary aerosol). Figure 3 indicates that the stability of the sample introduction system was improved through the use of the high pressure nebulizer as well. Combining enhanced signal with lower noise should result in a significant improvement in detection limits which is borne out in Figure 4 for most elements; an improvement of 23% on average. The next step was to determine if the enhanced performance found with the nebulizer in the Varian system could be duplicated on the Perkin Elmer instrument. PERKIN ELMER RESULTS The tests above were repeated on the PE system (Figures through 7). Table 2. Instrumental Parameters Parameter Varian MPX Perkin Elmer Optima 2 Power (watts) Coolant flow (LPM) Aux. flow (LPM) Nebulizer gas flow (LPM) Viewing Read time (sec) 3..7 Axial 4.2.7 Axial Figure. Inter-nebulizer Reproducibility: 3.9% RSD at 2ml/min and.8% at ml/min 3 3 2 Counts 2 2ml/min ml/min 333 37 23 29 34 Nebulizer Glass Expansion Newsletter - February 2 - Page 2

Figure 2. Effect of Pressure on Performance - Signal Intensity (2ml/min uptake), Varian Results Normalized Emission Counts...9.9.8.8 23 34 37 29 333 8 78 4 777 3 AI 39.2 As 88.98 Ba 4.43 Ca 393.3 Cu 327.39 Mg 28.27 Mn 27. Mo 22.32 P 23.8 Avg. AR Avg. AR 3 Figure 3. Effect of Pressure on Performance - Long-term (2 hours) Stability (2ml/min uptake), Varian Results RSD% 4 3. 3 2. 2.. 23 34 37 29 333 8 78 4 777 3 AI 39.2 As 88.98 Ba 4.43 Ca 393.3 Cu 327.39 Mg 28.27 Mn 27. Mo 22.32 P 23.8 Si 2. Avg. AR Avg. AR 3 Figure 4. Effect of Pressure on Performance - Detection Limit (ml/min), Varian Results.4.2 Normalized DL..8..2. AI 39.2 As 88.98 Ba 4.43 Ca 393.3 Cu 327.39 K 7.49 Mg 28.27 P 23.8 S 8.972 Si 2. Glass Expansion Newsletter - February 2 - Page 3

Figure. Effect of Pressure on Performance - Signal Intensity (2ml/min uptake), Perkin Elmer Results Normalized Emission Counts.2..9.8.7...3.2 34 333 29 23 37 78 777 8 4 3 AI 39.3 As 88.979 Ba 233.27 Ca 37.933 Cu 327.393 K 7.49 Mg 28.27 Mn 27. Mo 22.3 Na 89.92 P 23.7 S 8.97 Si 2. Figure. Effect of Pressure on Performance - Long-term (2 hours) Stability (2ml/min uptake), Perkin Elmer Results RSD%. 4. 4 3. 3 2. 2.. 34 333 29 23 37 78 777 8 4 3 AI 39.3 As 88.979 Ba 233.27 Ca 37.933 Cu 327.393 K 7.49 Mg 28.27 Mn 27. Mo 22.3 Na 89.92 P 23.7 Si 2. Figure 7. Effect of Pressure on Performance - Detection Limit (2ml/min), Perkin Elmer Results 2.8..4 Normalized DL.2.8..2 AI 39.3 As 88.979 Ba 233.27 Ca 37.933 Cu 327.393 K 7.49 Mg 28.27 Mn 27. Mo 22.3 Na 89.92 P 23.7 S 8.97 Glass Expansion Newsletter - February 2 - Page 4

Similar enhancements in performance were observed with respect to sensitivity and stability. Figure 7 demonstrates the resultant improvement in detection limits; on average a 27% improvement with the nebulizer. This compares well with the 23% enhancement observed using the nebulizer on the Varian system. CONCLUSIONS A concentric glass nebulizer designed to operate at was manufactured and tested with respect to a number of performance criteria on two separate makes of ICP-AES spectrometer. This new design was found to be superior to the standard nebulizer for both systems. Future work will focus on the ability of this nebulizer to handle dissolved solids and its performance on ICP-MS instrumentation. NEW PRODUCTS PFA SPRAY CHAMBER FOR ICP-MS The extreme sensitivity of the ICP-MS technique demands exceptional purity in all sample introduction components. This is why we have developed a new range of PFA spray chambers for ICP-MS. The design is based on the established Tracey glass cyclonic spray chamber which is known for its excellent sensitivity and precision. Fast washout is also a feature of this design and enables the highest possible sample throughput. The PFA material is ultra-pure, making the new Tracey PFA44 spray chamber ideal for ultra-trace ICP-MS analyses. It is also totally inert, enabling the new spray chamber to be used with all common ICP-MS samples, including those containing HF. The Tracey PFA44 spray chamber incorporates the inert Helix nebulizer interface, which has minimal dead volume in order to minimise carry-over between samples. It can be teamed with the OpalMist PFA nebulizer to form the highest purity, most inert sample introduction system available. There is a system available to suit most ICP-MS models. Contact enquiries@geicp.com for more information. For ICP-OES analyses, PTFE (Teflon) represents a more cost-effective alternative. It is almost as pure as PFA and it offers the same inertness to all of the common samples, including those containing HF. We have now released a new range of PTFE spray chambers for ICP-OES. These are also based on the established Tracey cyclonic design with its renowned sensitivity, stability and fast washout. The Tracey TFE range also incorporates the inert Helix nebulizer interface to minimize carryover between samples. The Tracey TFE spray chambers are specially treated to ensure efficient drainage and they offer better sensitivity and precision than the old polypropylene spray chambers. They can be teamed with the PolyCon HFresistant nebulizers to form the ideal chemically inert sample introduction system for ICP-OES. There is a system available to suit most ICP-OES models. Contact enquiries@geicp.com for more information. Tracey TFE Spray Chamber - P/N 2-89-988 NIAGARA RAPID RINSE ACCESSORY WITH SERIAL COMMUNICATION The Niagara Rapid Rinse Accessory has been increasing ICP sample throughput and saving money for its users for about a year. A new model is now available which communicates with the autosampler through a serial cable rather than a trigger switch. This significantly simplifies the installation. The serial communications kit is available for most ICP/autosampler combinations and we are offering a free upgrade for existing users. Contact enquiries@geicp.com for details. Tracey PFA44 Spray Chamber - P/N 2-89-2 PTFE SPRAY CHAMBER FOR ICP-OES While the PFA material used for the Tracey PFA44 spray chambers has exceptional purity, it is relatively expensive. Niagara Rapid Rinse Accessory Glass Expansion Newsletter - February 2 - Page

INSTRUMENT NEWS FROM AGILENT TECHNOLOGIES Two new ICP-MS Educational Aids Free ICP-MS Primer This 8 page comprehensive guide to ICP-MS is designed to provide the reader with a clear understanding of the technique and its capabilities. The Primer describes the basic concepts of ICP-MS, moving to a closer look at the hardware design and finishing with an overview of all major applications. You can download a pdf of the ICP-MS Primer or request your own copy in paperback format via the Agilent ICP-MS website at www.agilent.com/chem/icpms. Agilent 7ce ORS Video Shows a sample s journey through the 7ce. This video describes the principles of ICP-MS, including an animated sequence of an ion s eye view as it travels through the 7ce. More information is found on the Agilent website. FROM TELEDYNE LEEMAN Measure Nitrogen by ICP-OES Teledyne Leeman Labs has developed an accessory for ICP-OES instruments which permits highly accurate determinations of elemental nitrogen in a variety of sample matrices. Nitrogen is an analyte of interest in materials ranging from phosphate-based fertilizers to organic compounds. In fertilizers, nitrogen (as ammonium) is a relatively expensive component and must be accurately measured to ensure both product quality and to contain production costs. While a variety of elements in fertilizers are routinely measured by ICP-OES, inorganic nitrogen has typically required alternate analytical techniques, such as the use of a dedicated nitrogen analyzer. Historically, there have been numerous limitations to the determination of inorganic nitrogen by ICP-OES. The primary limitations included high nitrogen blank levels from diffusion of laboratory air into the plasma and dissolution of air in the samples and standards. Leeman s new Nitrogen Accessory includes an air free optical path, a custom torch designed to prevent migration of nitrogen (from air) into the plasma and an innovative sample degassing device that is designed to work with conventional solution autosamplers. Together, these innovations allow the modern ICP to achieve levels of accuracy that used to require a dedicated nitrogen analyzer. To receive additional information, email LeemanLabsinfo@teledyne.com or visit their website at www.leemanlabs.com. FROM SPECTRO A Sidelong Glance Into The Plasma SPECTRO Analytical Instruments will introduce the new SPECTRO GENESIS SOP (Side-On-Plasma) with radial plasma observation at the Pittcon 2 Conference on March 3th. The ICP-OES records the entire spectrum between 7 and 777 nm, enabling the simultaneous determination of more than 7 elements. Based on similar technology to the SPECTRO GENESIS EOP introduced in 2, the SPECTRO GENESIS SOP utilizes an alternative transfer optic with radial observation of the plasma. The observation volume is smaller for radial observation of the plasma, explains Olaf Schulz, Product Manager for ICP at SPECTRO. The detection limits are not quite as low as for the EOP model of the instrument, but it makes up for this with a larger matrix tolerance: The instrument is much more precise for medium to high contents from the lower ppm to the percent range. The SPECTRO GENESIS SOP is designed to meet the requirements of industrial users. Typical applications include the examination of industrial waste water, the analysis of wear metals and additives in oils, and examination of soils and sludge in the agricultural industry. The instrument also can be used within the chemical industry to examine saline solutions or organic samples, for which axial plasma observation would not deliver satisfying results. Also currently available are the first packet of methods for use with the SPECTRO GENESIS SOP. FROM THERMO The World s Smallest ICP Thermo Electron Corporation announces the launch of its new icap Series, featuring the most compact ICP emission spectrometers available on the market, the icap 3 and the icap. Thermo s expertise within the ICP market has resulted in advanced, high efficiency optical design for these new instruments. The icap provides excellent resolution, stability and sensitivity and excellent detection limits which enable enhanced productivity, greater ease of operation and reduced cost of ownership. Thermo s new icap Series is equipped with a high power, solid state RF generator capable of handling all sample types. A distributed purge system offers reduced gas consumption and improved performance for elements Glass Expansion Newsletter - February 2 - Page

such as As, Sb, Se and Te. Fully automated wavelength calibration and offset correction ensure excellent longterm stability. The ergonomic design of a large 27 door o allows unrestricted access to a large sample compartment and peristaltic pump. A core part of any ICP spectrometer is the detector, and the icap series unique RACID8 fourth generation Charge Injection Device (CID) detector offers several unique benefits. Able to perform non-destructive readout, this detector allows high intensity signals to be read very rapidly while lower intensity signals are accumulated over a longer time, ensuring optimum signal to noise and resistance to saturation. The RACID8 detector allows selective Region Of Interest (ROI) and true random access pixel address, which greatly shortens analysis times and improves sample throughput. Japanese and Russian. Navigation is simple and you can switch languages at any time using the language buttons at the top of each page. PITTCON A wide selection of Glass Expansion products will be on display at Pittcon 2, Orlando, Florida, USA, March 3 -, 2. The display will include nebulizers, spray chambers, torches, RF coils and accessories (including the new Niagara Rapid Rinse Accessory). Glass Expansion specialists will be on hand to answer your questions and assist you to choose the optimum components for your ICP. Please visit us at Booth 429. The icap 3 offers fast, reliable and simplified performance for routine analysis and is available with either a dedicated Radial or Duo plasma source. The Radial view achieves optimum performance and minimum interference for difficult samples such as metals or used oils. Alternatively, the Duo offers the flexibility of axial view for lowest detection limits and Radial view for reduced interference, ideal for environmental samples. The icap provides ultimate flexibility and productivity, and is operated via powerful software with automated setup and automatic optimization. This system includes an intelligent operation mode which groups functions together, minimizing overhead time and ensuring a typical time saving of % for an analysis where both axial and radial measurements are being made. For more information about Thermo s new icap Series, please e-mail analyze@thermo.com or visit www.thermo.com/elemental. GLASS EXPANSION NEWS THE 2 CATALOG NOW AVAILABLE The new Glass Expansion catalog Issue is now available. This 32-page full color catalog lists nebulizers, spray chambers, torches, RF coils, ICP-MS cones, accessories and consumables for over 7 ICP-AES and ICP-MS models. If you would like your personal copy, please send your mailing address to enquiries@geicp.com and we will rush a copy to you. WEBSITE IN ITALIAN Most of the Glass Expansion website is now available in Italian. This is in addition to the previously available languages - English, French, German, Spanish, Chinese, Glass Expansion Newsletter - February 2 - Page 7