Single Use Curlew TM Multiple Biopsy Forceps

Similar documents
Initial placement 24FR Pull PEG kit REORDER NO:

Initial placement 20FR Guidewire PEG kit REORDER NO:

St. Jude Medical 8-Channel Adapter. Clinician's Manual

CLARIVEIN INFUSION CATHETER

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

AXS Catalyst Distal Access Catheter

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Advisor FL Circular Mapping Catheter, Sensor Enabled D-AVSE-D10-F20, D-AVSE-DF10-F20, D-AVSE-D10-F15, D-AVSE-DF10-F15. Instructions for Use

Device Preparation (all steps to be performed per standard interventional technique)

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

RD180 SP TECHNOLOGY GUIDE READ THIS PRODUCT INSERT THOROUGHLY BEFORE USE

Instructions for Use Reprocessed Arthroscopic Shavers

Directions For Use. All directions should be read before use

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

ER REBOA Catheter. Instructions for Use

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

Technique Guide Small Bone Fusion System

Cardiva Catalyst III INSTRUCTIONS FOR USE

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Ponsky * PEG Safety System - "Pull" Bard * PEG Safety System - "Guidewire" Information for Use

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

The following languages are included in this packet:

Step by Step Description Use of Bonopty Coaxial Bone Biopsy System

Step by step description - Use of Bonopty Bone Biopsy System, 12 gauge

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

TJF-160F/VF Cleaning and Disinfection Checklist

Step by step description - Use of Bonopty Bone Biopsy System, 14 gauge

TruGuard Custom Tongue and Jaw Positioner Instructions for Use

with Blom-Singer Gel Cap Insertion System

Passer. Sterile. D i. Do Not PASSER DESCRIPTION. The Ceterix. Page 1

Peel-Apart Percutaneous Introducer Kits for

INSTRUCTIONS FOR USE AND CARE

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

AXIOS Stent and Electrocautery Enhanced Delivery System. Quick Reference Guide

Tissue Acquisition. Introducing our large range of single use accessories for the collection of histology and cytology in the GI tract.

Technique Guide KISSloc Suture System

Lotus transducer Instructions for use

PRO-DENSE BONE GRAFT SUBSTITUTE

for the ideal insertion of peritoneal dialysis catheter (patent pending)

Directions For Use. All directions should be read before use. Page 1 of 8

Figure 1: Revolution TM Peripheral Atherectomy System Diagram. Table 1: Revolution TM Peripheral Atherectomy System Specifications Minimum Burr

WallFlex Biliary Metal Stents

low ProfIle neuro PlaTIng system

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

Low Profile Neuro Plating System. Surgical Technique

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

Inspection Window. Syringe Body

3.5 mm Locking Attachment Plate

Peritoneal Drainage System

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Correction System. Surgical Technique

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Altus Product description / Instructions for Use IFU 6 Rev. 1

Doc no: IFU/CPL Issue date: Rev no: 00 Rev date: 1

Oral Specimen Collection Device

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

Marrow Cellution Bone Marrow Aspirate (BMA) and Stem Cell Harvesting System

INSTRUCTIONS FOR USE

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

BACTISEAL Endoscopic Ventricular Catheter (REF & )

RECOMMENDED INSTRUCTIONS FOR USE

SURGICAL TECHNIQUE GUIDE

How to Use ENBREL : Vial Adapter Method

Integra SURGICAL TECHNIQUE. MemoFix Super Elastic Nitinol Staple System. Super Elastic Nitinol Staple System

Guidance for. implant removal. Straumann Dental Implant System

Instructions for Use. For use with. 10 mg vial

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

Instructions. Fibrlok Optical Fiber Splicing System. Issue 6, August 1991

8 Performing Medical Procedures

Transjugular liver access and biopsy

Instructions for Use io-flex Probe

CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique

COR. Precision Targeting Cartilage Repair System. Arthroscopic Technique for Repair of Osteochondral Defects

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Instructions for Use 1

Instructions for Use. Welcome!

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

MEDICAL CORPORATION Asbury Rd., P.O. Box 758, Farmingdale, NJ USA Fax

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

Instructions for Use Reprocessed 3D Diagnostic Ultrasound Catheters

Quick Reference Guide

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

FS MTS. Micro Periodontal Tissue Scissors

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

NONGYNECOLOGICAL CYTOLOGY FINE NEEDLE ASPIRATION SPECIMENS

Doc no: IFU/CC Issue date: Rev no: 04 Rev date:

eptfe Vascular Graft Instructions for Use

Aspira* Peritoneal Drainage Catheter

Transcription:

Single Use Curlew TM Multiple Biopsy Forceps 13 SPECIMEN WITH METAL STORAGE CYLINDER With In Situ Fixation, Batch or Single Specimen Collection US Patents 5,782,747; 5,980,468; 6,071,248; foreign patents and pending INSTRUCTIONS FOR USE Read this document in its entirety prior to use Rx Only Caution: Federal (USA) Law restricts this device to sale by or on the order of a physician Warning: This Device is Sharp! Use same care as for any other surgical device to avoid punctures or cuts to hands, gloves, etc. Caution: A thorough understanding of the technical principles, clinical application and risks associated with multiple biopsy is necessary before using this instrument Indications: Biopsy forceps are intended for use in collecting tissue samples for histological examination. Page 1 of 8

Contraindications: None known within the scope of the indicated use. Warning: For single use only. Do not reuse, reprocess or sterilize. Reuse, reprocessing or re-sterilization may compromise the structural integrity of the device and/ or lead to device failure which, in turn, may result in patient injury, illness or death. Inspection: Warning: Inspect the package containing the forceps. If any damage is noticed, do not use the instrument as sterility may be compromised. Peel open the pouch and remove the forceps. Visually inspect the forceps for kinks, loose or broken parts. With forceps coiled in 8 inch loops: (2) for 230cm; (1) for 160cm; (1) for 110cm, verify forceps operate freely with no hesitation, and smoothly with no grinding, friction or clicking. Warning: Do not use if any abnormalities are found or if the instrument is not operating properly. Device Overview The Curlew Multiple Biopsy forceps collects and stores up to 13 biopsies 2.0mm in diameter in a separable perforated metal storage cylinder for in situ fixation and transport to pathology with minimum handling and staff exposure to human material, sharps and solvents. In situ fixation is fixation of the entire 13 specimen biopsy series within the metal storage cylinder. This minimizes the work, exposure to sharps and human material previously required to separate the biopsies from the biopsy device in endoscopy. The metal storage cylinder maintains, collects and orients stored specimens in acquisition order as documented in the Curlew Multiple Biopsy Endoscopy Log (Attached to last page of the Pathology Laboratory Instructions) through histopathological processing with minimum handling in pathology. Multiple sections are mounted on slides in acquisition order for reading by the pathologist. Curlew Multiple Biopsy forceps requires a minimum 3.2mm endoscope channel. For biopsy the jaws are pushed out of the storage cylinder and inserted into the tissue to surround the specimen. During jaw closure and retraction, biopsies are cut, captured, oriented and collected in the storage cylinder in acquisition order. This action: (1) retains specimens in the storage cylinder Page 2 of 8

during and after endoscope withdrawal, during in situ fixation and transport to pathology; (2) protects staff during multiple biopsy use; (3) prevents endoscope instrument channel damage during passage and withdrawal. The Curlew label on the pouch and fixative vial indicate the maximum number of specimens collected in a single endoscopic pass and held in the storage cylinder for in situ fixation. The Curlew Multiple Biopsy Endoscopy Log (Attached to last page of the Pathology Laboratory Instructions) completed by the endoscopist identifies the number of specimens, biopsy sites, acquisition order and indications to the pathologist. When in situ fixation is not used, numerous multiple biopsy passes are supported. Operation: For hot multiple biopsy forceps; connect an Olympus compatible active cord to the instrument and ensure the connection is tight. Inspect the active cord for kinks, bends, breaks and exposed wires. If any abnormality is found, do not use the cord. The cord should snap onto the handle. If the cord is loose, call your sales representative who can provide you with the proper cord. Connect the other end of the cord to the electrosurgical generator and follow the manufacturer s instructions regarding operation and proper grounding. NOTE: IT IS IMPORTANT TO USE AN OLYMPUS COMPATIBLE PLUG. OTHER PLUG CONFIGURATIONS CAN LEAD TO FAULTY OPERATION. Warning: Connection to equipment not complying with EN 60601-2-2 could compromise patient safety. Prepare the Curlew Multiple Biopsy Endoscopy Log (Attached to last page of the Pathology Laboratory Instructions) to record the site, sequence and indication of each biopsy. Extend the biopsy jaws by gently pulling back on the thumb loop and retract by advancing the thumb loop to the stop to confirm easy biopsy action. Page 3 of 8

Do not open and close the jaws without straightening the shaft as that may alter the precise biopsy action. Observe that the jaws retract fully into the biopsy storage cylinder when the thumb loop is advanced to the handle stop. Full jaw retraction ensures that the endoscope instrument channel is not damaged during passage or withdrawal and that the biopsy specimens are retained in the storage cylinder during withdrawal from the endoscope. Close the forceps jaws before inserting the instrument into a 3.2mm endoscope channel. Use short motions when inserting the forceps to avoid kinking. If the scope is equipped with an elevator, lower the elevator fully before loading. If resistance is met when the bending tip of the forceps is angulated, release the bending angle slightly until the instrument passes smoothly. Do not force the forceps into an angulated scope as this could damage the endoscope. To take a biopsy, place the instrument tip close to the desired biopsy site and gently retract the thumb loop to extend the jaws while visualizing the procedure through the scope. Advance the open jaws into the tissue to surround the biopsy site. Close the jaws by gently advancing the thumb loop to the handle stop. The closing jaws cut, capture, orient and store the specimen in the storage cylinder, in the order of acquisition. Inspect the biopsy site for the bleeding mucosal defect indicating biospy capture. Capture failure is caused by not inserting the open jaws into the tissue as with a biopsy pin. Note the biopsy site, sequence and indication on Page 4 of 8

the Curlew Multiple Biopsy Endoscopy Log (Attached to last page of the Pathology Laboratory Instructions). Repeat until up to 13 biopsies, or the desired number of biopsies, are obtained. Caution: Do not use excessive force to close the jaws as this could damage the instrument. When the biopsy sequence is complete, fully retract the jaws into the biopsy storage cylinder and slowly withdraw the instrument from the scope while keeping the jaws closed. If the scope has a forceps elevator, it must be lowered before withdrawing the forceps. If the jaws will not close completely, do not force the forceps out of the endoscope. Remove the endoscope with the forceps still in place and then manually close the jaws before removing the instrument from the scope. Retrieval and Fixation of Batched or Individual Multiple Biopsy Specimens: After removing the biopsy instrument from the endoscope, keep the jaws closed inside the metal storage cylinder by pressing the thumb loop against the handle stop. This prevents loss of the specimens and protects staff from contact with sharps, jaws and potentially infectious tissue or fluid. With storage cylinder over the fixative vial, retract the thumb loop to open the storage cylinder. Cut the black cable ½ inch from the metal storage cylinder with a heavy wire cutter. (Do not cut or damage the metal cylinder as this may prevent specimen removal in pathology.) Place the metal storage cylinder in labeled fixative vial for transport to pathology. Affix a matching label to the Curlew Multiple Biopsy Endoscopy Log (Attached to last page of the Pathology Laboratory Instructions) for transport to pathology. Page 5 of 8

Batch Collection of Specimens without in situ fixation: (Irrigation of specimen batches from the storage cylinder into fixative) Prepare a blunt 20G needle on a 3ml syringe filled with fixative. Remove Multiple Biopsy forceps device from the endoscope and hold the storage tip over the fixative vial. Retract the thumb loop to open the storage cylinder. Identify an open proximal storage cylinder hole (not blocked by forceps mechanism). Insert irrigation needle in an open proximal storage cylinder hole. Irrigate specimens into fixative. Examine the storage cylinder to ensure all specimens have been removed. Repeat if specimens remain. Single Specimen Collection without in situ fixation: Each biopsy specimen is held within the biopsy jaws until pushed into the storage cylinder by the subsequent biopsy. Individual specimens may be collected from the sharp biopsy jaws by removing the Multiple Biopsy forceps from the endoscope, opening the jaws and placing the specimen in fixative. Disposal: Page 6 of 8

Warning: After use, this product may be a potential biohazard. Handle or dispose of it in accordance with accepted medical practice and applicable local, state and federal laws and regulations. Storage: Store sterile instruments at room temperature. Do not expose to solvents, radiation, UV light or any other substance or environment that could compromise the sterility of the unit. Warranty: Endo-Therapeutics Inc. warrants that the instrument will be free from defects in materials and workmanship for use in a single procedure. This warranty does not apply to use beyond the expiration date. This device is not intended to be reprocessed. The user assumes responsibility for any consequences related to the use of reprocessed instruments. Endo- Therapeutics obligations under this warranty are limited to the replacement of the instrument. Page 7 of 8

Symbols used on labeling Consult Instruction for Use Warning - Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Caution - Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Single use Do not reuse Ethylene Oxide Sterilization Catalog Number / Product Code Lot Number Use by Date Rx Only Federal (USA) Law restricts this device to sale by or on the order of a physician Authorized Representative Manufacturer Page 8 of 8