Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

Similar documents
Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up

Analysis of factors affecting range of motion after Total Knee Arthroplasty

Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system

Range of Motion of Standard and High-Flexion Posterior Stabilized Total Knee Prostheses A PROSPECTIVE, RANDOMIZED STUDY

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o

Knee kinematics after TKA depends on preoperative kinematics

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

Clinical evaluation of 292 Genesis II posterior stabilized high-flexion total knee arthroplasty: range of motion and predictors

Fixed bearing versus high flexion RP total knee arthroplasty (TKA): midterm results of a randomized controlled trial

Early Results of Total Knee Replacements:

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

NexGen Legacy LPS-Flex Knee. Brochure

Clinical Results of Lateral Unicompartmental Knee Arthroplasty: Minimum 2-Year Follow-up

The Egyptian Journal of Hospital Medicine (January 2019) Vol. 74 (7), Page

Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete

Noninvasive Assessment of Sagittal Knee Kinematics After Total Knee Arthroplasty

Clinical Performance of the Optetrak Total Knee Prosthesis: A 11-year Follow-up Study

Kinematic vs. mechanical alignment: What is the difference?

1 Introduction. 2 Data and method

PRE & POST OPERATIVE RADIOLOGICAL ASSESSMENT IN TOTAL KNEE REPLACEMENT. Dr. Divya Rani K 2 nd Year Resident Dept. of Radiology

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

15-Year Follow-up Study of Total Knee Arthroplasty in Patients With Rheumatoid Arthritis

Original Article. Introduction. Materials and Methods

Sasaki E 1,2, Otsuka H 2, Sasaki N 2, and Ishibashi Y 1

Evaluation of soft-tissue balance during total knee arthroplasty

Full Function, Faster Medial-Pivot

Dora Street, Hurstville 160 Belmore Road, Randwick

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY

Design modifications of high-flexion TKA do not improve short term clinical and radiographic outcomes

Kinematic analysis of posterior-stabilized total knee arthroplasty during standing up from and sitting down on a chair

Functional and radiological outcome of total knee replacement in varus deformity of the knee

Influence of Hip Position on Knee Flexion Angle in Patients Undergoing Total Knee Arthroplasty

Editorial Manager(tm) for Clinical Orthopaedics and Related Research Manuscript Draft

Comparison Between Standard and Gender-Specific Knee Designs in Total Knee Arthroplasty in Female Patients

Excellent vs. Good Range of Motion after TKA, What Makes the Difference?

Revolution. Unicompartmental Knee System

The Knee 21 S1 (2014) S10 S14. Contents lists available at ScienceDirect. The Knee

Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing?

SAIPH Knee System. Clinical Data Summary. Physiological Stability and Mobility for the Active Knee Without Compromise

ISSN X (Print) Original Research Article. *Corresponding author Dr Shaival Chauhan

Clinical Results of Genesis-I Total Knee Arthroplasty

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977)

Knee Surg Relat Res 2011;23(3): pissn eissn Knee Surgery & Related Research

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

Closing Wedge Retrotubercular Tibial Osteotomy and TKA for Posttraumatic Osteoarthritis With Angular Deformity

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

Condylar constrained system in primary total knee replacement: our experience and literature review

Estimating Total Knee Arthroplasty Joint Loads from Kinematics

Total Knee Original System Primary Surgical Technique

Anterior knee pain following total knee replacement caused by isolated Paget's disease of patella

Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty

Total Knee Replacement

Distal femoral condyle is more internally rotated to the patellar tendon at 90 of flexion in normal knees

The causes of OA of the knee are multiple and include aging (wear and tear), obesity, and previous knee trauma or surgery. OA affects usually the

THE KNEE SOCIETY VIRTUAL FELLOWSHIP

Magic Mobile bearing Potion I fall down when I was a kid. Mobile is better? Seb, For the nice cars, you need a good flexion! I can be objective!

Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA

Ju-Yeong Kwak, MD, Jae-Heon Jeong, MD*, Sang-Hak Lee, MD, Ho-Joong Jung, MD, Young-Bok Jung, MD

Why precision is powerful

Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis

Case Report Total Knee Arthroplasty in a Patient with Bilateral Congenital Dislocation of the Patella Treated with a Different Method in Each Knee

Medium term results of the Miller-Galante unicompartmental knee arthroplasty with 10 year survivorship

Insert dissociation after fixed bearing PS constrained Genesis II total knee arthroplasty. A case series of nine patients

Session 24: Primary TKA: The Impact of Technique

VARIABILITY OF THE POSTERIOR CONDYLAR ANGLE

Total Knee Arthroplasty in a Patient with an Ankylosing Knee after Previous Patellectomy

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

The Journal of Arthroplasty

DIFFICULT PRIMARY TKA: VALGUS KNEE

Knee Surg Relat Res 2013;25(1): pissn eissn Knee Surgery & Related Research

Effects of Variation in Surgical Technique on Range of Motion in Total Knee Replacement

ATTUNE Knee System: Stability in Total Knee Replacement

The UniSpacer : correcting varus malalignment in medial gonarthrosis

Is There A Difference In Uni- And Multi-compartmental Knee Arthroplasty Kinematics?

Medial Knee Osteoarthritis Precedes Medial Meniscal Posterior Root Tear with an Event of Painful Popping

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

Mædica - a Journal of Clinical Medicine

High flexion knee arthroplasty: the relationship between rotational angles and flexion angle after total knee arthroplasty

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

Think isometry Feel balance

A DISSERTATION SUBMITTED TO THE UNIVERSITY

EMPOWERING LIFE THROUGH NATURAL MOTION

BOOK CHAPTERS PUBLICATIONS

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

Biomechanics of the Knee. Valerie Nuñez SpR Frimley Park Hospital

Imaging assessment of Unicomp candidates!

Mini-Midvastus Approach Shows Improved Short- Term Outcomes in Primary TKA Compared to Medial Parapatellar Approach

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

Abramsohn Retractor 1

Anterior referencing versus posterior referencing in total knee arthroplasty: a prospective observational study

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY

Influence of Posterior Condylar Offset on Maximal Flexion and Outcome Scales Following TKA in Asian Patients

Tissue-sparing surgery with the bi-unicompartmental knee prosthesis: retrospective study with minimum follow-up of 36 months

No radiographic difference between patient-specific guiding and conventional Oxford UKA surgery

Bilateral Total Knee Replacements using Two Different Implant Designs - Preliminary Report

)289( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY RESEARCH ARTICLE

Transcription:

ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 14 Number 1 Comparison of high-flex and conventional implants for bilateral total knee arthroplasty C Martin-Hernandez, M Guillen-Soriano, A Castro-Sauras, J Ballester- Jimenez, T Espallargas-Doñate, A Fuertes-Vallcorba Citation C Martin-Hernandez, M Guillen-Soriano, A Castro-Sauras, J Ballester-Jimenez, T Espallargas-Doñate, A Fuertes-Vallcorba. Comparison of high-flex and conventional implants for bilateral total knee arthroplasty. The Internet Journal of Orthopedic Surgery. 2008 Volume 14 Number 1. Abstract Clinical and radiographical outcomes of conventional versus high-flex implants were compared in a prospective study in twenty patients one year after bilateral total knee replacement. First, a conventional posterior stabilized total knee arthroplasty (TKA) was implanted in one limb. Six to eight months later, the contralateral knee of each patient was replaced with a high-flexion design TKA. Clinical and radiological parameters including Knee Society objective and functional Scores (KSS), range of motion, tibial slope, position of the femoral component, angles between the components and the anatomical axis of femur and tibia and final varus or valgus alignment were evaluated one year after the operation.one year after surgery, for PS implants mean knee score and mean functional score were 79 points (range 72 to 93 points) and 81 points (range 70 to 100 points), whereas for RPF knees they were 86 points (range 76 to 93 points) and 91 points (range 75 to 100 points) respectively. Mean maximal flexion 97º in the PS group and 118º in the RPF knees. These results were significantly better for the High flex implants. No differences were found in the radiological results.we conclude that the high flexion TKA is associated with a higher range of motion of the knee resulting in better functional outcomes. INTRODUCTION Patient satisfaction after total knee arthroplasty (TKA) depends not only on pain relief but also on the range of motion [1,2]. A knee flexion of 90º to 100º is enough to allow most activities of daily living for elderly people in western countries. Climbing up and down the stairs and sitting on a chair requires 90 to 120º. This range of motion can be achieved with conventional TKA designs whose maximal flexion angle has been reported to range between 100 and 110º [3]. Apart from being influenced by the condition of the patient and surgical technique, the final outcome of a TKA, depends also on the implant design. Therefore, implant manufacturers have attempted to design TKAs that better accommodate knee mechanics in high flexion up to 155 [4,5] to allow patients activities such as squatting and sitting cross-legged which require knee flexion of 110 to 130º [6]. High-flexion implants were initially designed thinking of people who need more flexion in their professional, cultural and religious environments, specially in Asian countries. Nowadays, the demands made on TKA implants are increasing due to a reduction in the age of patients undergoing this procedure, thus high flexion designs are now more often implanted. The aim of this study was to compare the early clinical outcome and radiological results after bilateral total knee replacement first using in each patient a conventional posterior stabilized implant and later on a high flexion TKA in the contralateral side. MATERIALS AND METHODS In 2007, we included 20 patients (7 men and 13 women) who underwent total knee replacement in a prospective study. Mean age of the patients was 75 years (range 65 to 81years). All patients in this study were diagnosed with bilateral degenerative arthritis, had a body mass index (BMI) less than 30, no previous joint infection, no inflammatory disease, a varus deformity of less than 10 or a valgus deformity less than 5. Knee function according to the Knee Society objective and functional Scores (KSS) was recorded before the operation. Anterior, lateral, axial and long standing x-rays views were performed preoperatively. Patients were first operated on of one knee with a conventional posterior stabilized (PS) implant (Depuy PFC Sigma PS). Six to eight months later, surgery was performed 1 of 5

on the contralateral knee of each patient with a high flexion (RPF) TKA (Depuy PFC Sigma RP Flex). All surgeries were done by two well-trained surgeons. The operative procedures were the same for both the knees in each patient. In all procedures, a medial parapatellar approach was used. Both the anterior and posterior cruciate ligaments were resected in all the cases. Both femoral and tibial components were cemented. The patella was always resurfaced with a cemented implant. Tourniquet was used in every patient. Drains were removed 48 hours after surgery. The rehabilitation program during admission was the same for all the patients. Immediately after surgery they were encouraged to begin quadriceps strengthening exercises. Weight bearing and active ROM exercises were started 24 hours postoperatively and the patients were discharged 8 9 days after surgery. Follow-ups were scheduled 3 weeks, 3 months and one year after surgery. Clinical and radiological examinations were done in each visit. Clinical parameters including KSS, range of motion, maximal extension and flexion were finally evaluated one year after the operation. Preoperative and postoperative maximal flexion and extension were determined with a goniometer on the lateral side of the knee on supine position. Radiographic evaluation included both knee standing AP and lateral projections and lateral views in maximal flexion. In the lateral x-rays, the tibial slope, the position of the femoral component (angle between femoral axis and implant axis) and the maximal knee flexion degree were recorded. For long standing x-rays we analysed the accuracy of component position with respect to the anatomical references. We also recorded the alignment of the tibial component with respect to the centre of the ankle, the alignment of the femoral component with respect to the mechanical axis of the femur and the final varus or valgus limb alignment. All these measurements were performed by an independent radiologist. (range 15 to 70 points). Mean maximal flexion was 85º before the operation in the PS knees (range 60º to 120º) and 87º in the RPF group (range 60º to 115º). Preoperative alignment for PS knees was a varus deformity in 19 cases (mean 12º, standard deviation 3.5º) and a 7º valgus in one case. In the RPF group, the alignment was varus in 19 cases (mean 12.5º, SD 3.5º) and a 6º valgus in one case. Postoperative clinical results are summarized in table 1. One year after surgery, mean knee score and mean functional score were 86 points (range 74 to 90 points) and 81 points (range 70 to 100 points) for PS implants, whereas for RPF knees they were 88 points (range 76 to 93 points) and 91 points (range 75 to 100 points) respectively. There were no statistical differences in the KSS objective score (P=0.3), but the functional score was significantly higher in the PFC knees (P=0.0036). No flexion contractures were found after surgery. Maximal flexion was significantly higher in the RPF group (mean 119º, range 90º to 140º) (Fig.1) than in the PS group (mean 97º, range 80º to 120º) (Fig 2.) P=0.0007. Postoperative radiological data are presented in table 2. No statistical differences were found between both types of implant. Figure 1 Table 1. KSS scores and range of flexion The data were analyzed using paired Student t test and Student t test. Differences were considered statistically significant at P<0.05. RESULTS Preoperatively, the mean knee score was 41 points for the PS knees (range 11 to 60 points) and 40 for the RPF (range 13 to 58). The mean functional score was 44 points in the PS TKA (range 5 to 70 points) and 43 points in the RPF knees 2 of 5

Figure 2 Picture 1. Range of flexion of a RPF knee Figure 3 Picture 2. Range of flexion of the PS knee in the same patient depends on several factors including preoperative ROM [7], pain control and implant design [8]. It is well known that the range of motion after TKA is important for a patient s overall functional outcome [9]. ROM after TKA using conventional implants has been reported to be about 110º [10]. This range of motion allows most of the activities of daily living in elder people, such as climbing up and down the stairs or sitting and getting up from a chair. High-flexion implants were initially designed in an attempt to obtain higher degrees of flexion for those patients whose culture requires squatting, kneeling or sitting cross-legged [11]. Nowadays, as the average age of patients who undergo TKA continues to decrease, it is desirable for knee prosthesis to allow more flexion as it would be required for many lowimpact sporting activities. Results using high-flex implants are controversial. Huang et al [12] reported no difference in KSS results. However they found an average flexion 10º higher than using a conventional PS implant. Bin et al [13] also found a significantly higher maximal flexion in the high-flex TKA but no differences in the clinical or radiographical outcomes. To the contrary, Kim et al [14] did not find any differences in the flexion obtained in a prospective randomized study after bilateral TKA. In our study, the objective KSS score showed no differences between the two implants. This may be due to the fact that the knee score is only increased by only one point for each five degrees of flexion. To the contrary, we found a statistically significant difference in functional KSS scores when comparing high-flex and conventional PS TKA. These results were mainly determined by a better ability to climb up and down the stairs. Figure 4 Table 2. Mean values of the radiographic measurements (Posterior slope of the tibila component and flexion of the femoral component in the lateral x-rays. Angle between femoral and tibial components and their respective anatomical axis in the antero-posterior view) DISCUSSION The amount of flexion a patient with a TKA can obtain In all the patients except for one, RPF implants resulted in greater flexion of the knee joint than the PS implants. In concordance with the majority of reports, we did not find radiological differences when analysing the component position and alignment between our TKR groups. The main advantage of this study is that both kinds of implant were tested in the same patient, avoiding that demographic, body weight and subjective parameters could affect the results. The limitation is that the prosthesis were not implanted simultaneously, thus slight variations in the rehabilitation protocols could modify the outcomes. CONCLUSION 3 of 5

We conclude that the high flexion TKA is associated with a higher range of motion of the knee resulting in better functional outcomes. References 1. Anouchi YS, McShane M, Kelly F Jr et al. Range of motion in total knee replacement. Clin Orthop 2005; 331:87 92 2. Chew JTH, Stewart NJ, Hanssen AD et al. Differences in patellar tracking and knee kinetics among three different total knee designs. Clin Orthop 1997; 345:87 98 3. Dennis DA, Komistek RD, Colwell CE et al. In vivo anteriorposterior femorotibial translation of total knee arthroplasty : a multicenter analysis. Clin Orthop 1998; 356:47 57 4. Argenson JA, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM. In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 2005; 38:277 84. 5. Huang HT, Su JY, Wang GJ. The early results of high flexion total knee arthroplasty. A minimum of 2 years of follow up. J Arthroplasty 2005; 20:674 9 6. Dennis DA, Komistek RD, Stiehl JB et al. Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 1998; 3:748 52 7. Kotani A, Yonekura A, Bourne RB. Factors influencing range of motion after contemporary total knee artfroplasty. J Arthroplasty 2005;20:850-6 8. Laskin RS. The effect of a hig-flex implant on postoperative flexion after primary total knee arthroplasty. Orthopedics 2007; 30(8 suppl):86-8 9. Ritter MA, Campbell ED. Effect of range of motion on the success of a total knee arthroplasty. J Arthroplast 1987; 2:95 7 10. Bellemans J, Banks S, Victor J et al. Fluoroscopic analysis of the knee kinematics of deep flexion in total knee arthroplasty. Influence of posterior condyle offset. J Bone Joint Surg 2002; 84-B:50 3 11. Koshino T, Saitop T, Orito K, et al. Increase in ranger of knee motion to obtain floor sitting after high tibial osteotomy for osteoarthritis. Knee 2002; 122:156-60 12. Huang HT, Su JY, Wang GJ. The early results of highflex total knee arthroplasty: a minimum of 2 years of followup. J Arthroplasty. 2005; 20(5):674-9. 13. Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007;15(4):350-5 14. Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005; 87(7):1470-5. 4 of 5

Author Information Carlos Martin-Hernandez, M.D Melchor Guillen-Soriano, M.D Angel Castro-Sauras, M.D Juan J. Ballester-Jimenez, M.D Teresa Espallargas-Doñate, M.D Ariana Fuertes-Vallcorba, M.D. 5 of 5