CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Similar documents
This is a CLIA-waived system. Policies and Procedures Manual

How to Use ENBREL : Vial Adapter Method

CoaguChek XS Plus System Whole Blood Protime/INR

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

System. User Manual for Self-Testing

Blood Glucose Monitoring System. User Guide

User Manual. This is a CLIA waived system.

Tips for Training New Customers

PROCEDURE. TITLE: Bedside Glucose Monitoring PC Laboratory. Issuing Department: Clinical Director Signature: Departments Involved:

Items in the package:

Roche CoaguChek XS Plus INR

Blood Glucose & Ketone Monitoring System

ONE-STEP WHOLE BLOOD H.PYLORI TEST. Product Code: 24529

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

User Guide For in vitro Diagnostic Use in Animals Featuring the AlphaTRAK 2 Meter

User manual for healthcare professionals

BLOOD COLLECTION GUIDELINES

Logic. Owner s Guide. Blood Glucose Monitor

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

CentriVet GK Blood Glucose & Ketone Monitoring System

Fraser Health Authority Accu-chek Inform II: Training Script

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

Before you use the TALTZ autoinjector, read and carefully follow all the step-by-step instructions.

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

Blood Glucose Monitoring System

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

IMPORTANT: PLEASE READ. Don t

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

EME. Self-Monitoring Blood Glucose System. Quick Reference Guide

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Dear HemoSmart GOLD Owner

How to Set Up and Infuse Your TPN

Instructions for Use. Welcome!

Blood Glucose Monitoring System. Owner s Booklet

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Instructions for Use. For use with. 10 mg vial

Instructions for Use Enbrel (en-brel) (etanercept) Single-use Prefilled SureClick Autoinjector

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

MDT2. Self-Monitoring Blood Glucose System. Quick Reference Guide

Blood Glucose Monitoring System

Owner s Booklet. 24/7 Customer Care English or Spanish Manufactured by:

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

PRIMA Lab SA Via Antonio Monti Balerna Switzerland 0041 (0) primahometest.com

Mixing Two Insulins. Getting Ready. What to Do

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

Blood Ketone and Glucose Monitoring System Owner s Guide For Veterinary Animal Use Only Not For Human Use

Blood glucose monitor. MediTouch 2

Lilly. Disposable Insulin Delivery Device User Manual

Management of Central Venous Access Devices. Blood Glucose Monitoring

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

Alere INRatio 2 METHOD AND SAMPLE COLLECTION

Dear HighQ Check System Owner :

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Syringe (75 mg/ml)

User s Manual. Blood Glucose Meter

Specimen Collection Policies

Blood Glucose Monitoring System

Education for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

Caution: Federal law restricts this device to sale by or on the order of a physician.

EasyMax Voice III Self-Monitoring Blood Glucose System. Quick Reference Guide

SELF-INJECTION TRAINING GUIDE

I can show you how to check my child s blood sugar

Pfizer, BeneFIX R2 Recombinant Factor IX

Table of Contents Section 1 Introduction... 1 Section 2 System Components... 4 Section 4 Initial Setup... 9 Section 5 Meter Setup and Options...

Applicable To NOTE: CAPILLARY PUNCTURE-DO NOT WIPE AWAY THE FIRST DROP OF BLOOD.

Blood Glucose Monitoring System

Unigold Recombigen HIV 1/2 Training for HIV Testing Sites. Updated: February 2018 Cicely Richard Office of HIV/AIDS

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

PATIENT INSTRUCTIONS FOR USE SINGLE- DOSE PREFILLED SYRINGE

INSTRUCTIONS FOR USE. EMGALITY TM (em-gal-it-ē) (galcanezumab-gnlm)

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

i-stat CHEM8 + Cartridge Quick Reference Guide

Inspection Window. Syringe Body

BLINDED MODE USERS GUIDE SUPPLEMENT

CoaguChek Outpatient Clinic: CoaguChek XS - Quick Reference Guide

PLEASE READ THIS USER MANUAL BEFORE USE

Performa BLOOD GLUCOSE METER. Operator s Manual

INSTRUCTIONS FOR USE. Norditropin NordiFlex Somatropin (rdna origin) injection 30 mg/3 ml Prefilled Pen

PEN USER MANUAL Byetta 5 micrograms solution for injection in pre-filled pen (exenatide)

Table of Contents. Section 1 Introduction... 1 Section 2 Getting Started... 2 Section 3 Components... 5

Point of Care testing refers to all laboratory testing that is done outside of the walls of the clinical laboratory in the proximity of the patient.

MYALEPT (MAI-uh-lept) (metreleptin) for injection for subcutaneous use

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

balance Owner s Booklet 24/7 Customer Consultation English or Spanish Manufactured by:

Dear Wellion LEONARDO GLU/CHOL (plus) Owner,

IMPORTANT: PLEASE READ

EduCare Knowledge & Skill Assessment Medication I Routes

Coag-Sense Prothrombin Time (PT)/INR Monitoring System Professional User s Manual

Point of Care Testing. Bedside Glucose Meter

Blood Glucose Monitoring System

For use only with INSTRUCTIONS FOR USE

User s Manual Blood Glucose Meter

Instructions For Use. SOLUTION FOR INJECTION IN PRE-FILLED PEN 250 micrograms

MICAFUNGIN MIXING

Transcription:

CoaguChek S System This is a CLIA-waived System Quick Reference Guide Coagulation Testing with Fresh Whole Blood May not print or view at 100% All unmarked prints black. Coag Swoosh prints gradients of PMS 300 on top and PMS 194 on bottom. Swoosh bleeds right. The letter S in the Coag logo prints PMS300 The word System in the Coag logo prints 50% black. Roche Logo prints PMS 300. Inside front and back covers are blank. Read your User s Manual for additional information.

Table of Contents Patient Testing...3 Liquid Quality Control Testing...8 Changing Result Units...12 Reviewing Memory...12 1

Patient Testing 1. What you need: CoaguChek S monitor Test Strips in foil pouch Test Strip Code Chip Cotton balls or tissue Alcohol wipe Code Chip ALCOHOL PREP For a capillary sample: Lancet Capillary tube and bulb Cat. No. 461 (REF 11621173001) (optional) Lancet device (optional) For a venous sample: Plastic syringe (anticoagulant-free) Syringe needle should be 23 gauge or larger. A 21 gauge or larger needle is recommended. Tourniquet 2. Test strips must be out of the refrigerator for at least five minutes before use. Keep remaining pouches in refrigerator. Make sure Test Strip Code Chip number matches the first three numbers after the lot symbol on the test strip pouch. If numbers do not match, see User s Manual. 3. For capillary sample: Prepare lancet device. Firmly insert end of capillary tube into capillary bulb to the line. For venous sample: Prepare a plastic syringe that is free of anticoagulant. 3

Patient Testing Patient Testing 4. Place monitor on a flat surface, free of vibrations, and turn on. Monitor displays code number. Make sure it matches the code number of the test strips you are using. The test strip icon flashes. 5. Open test strip pouch and remove the test strip. It must be used within FOUR minutes of opening. 6. Gently insert test strip in the direction of the arrows with printed side facing up. Push test strip in until it stops. Monitor displays the test strip icon. The clock icon flashes. Do not apply sample until the flashing blood drop icon appears. 01 7. When the flashing blood drop icon appears, the monitor begins a 180-second countdown, beeping every 30 seconds, until sample is applied. Sample must be applied before the countdown reaches zero. A flashing yellow light through the test strip indicates where to apply the blood. For a capillary sample: Clean the finger with an alcohol wipe or use soap and warm water. Dry thoroughly. Perform fingerstick and gently squeeze finger to develop a hanging drop of blood. Use the first drop of blood. For a venous sample: Disinfect venipuncture site with an alcohol wipe. Allow to dry. Draw sample into syringe. 8. For capillary collection only: Touch the capillary tube to the drop of blood. Keep the tube level and allow it to fill by capillary action. Fill the capillary tube halfway. Do not place finger over hole in bulb. Note: Blood may also be applied directly from the finger to the sample target area. 4 5

Patient Testing Patient Testing To apply a capillary sample: Place finger over hole in end of capillary bulb and gently push down on top of bulb until sample has been completely expelled onto the sample target area. Avoid introducing air bubbles when applying the sample. 11. Remove test strip and discard according to proper infection control guidelines. 12. The flashing test strip icon reappears on the display. If you are finished testing, turn monitor off. To apply a venous sample: Discard the first four drops of blood from the needle, then immediately place one drop of blood from syringe needle directly onto sample target area of test strip. Avoid introducing air bubbles when applying the sample. 9. Monitor displays the clock icon. Do not touch the test strip or add more blood. 10. The result appears in about one minute. Results are stored in memory. If an up or down arrow is in front of the result, the test result is higher than or lower than the measuring range of the system. Refer to the Unexpected Results section of the test strip package insert for more information. or or 6 7

Code Chip Liquid Quality Control Testing Liquid Quality Control Testing What you need: CoaguChek S monitor Test Strips in foil pouch Test Strip Code Chip CoaguChek S System Controls Level 1 and 2 Timer Place monitor on a flat surface, free of vibrations, and turn on. Monitor displays code number. Make sure it matches the code number of the test strips you are using. The test strip icon flashes. 1. Remove test strips and controls from the refrigerator. Test strips must be out of the refrigerator for at least five minutes before use. Please Note: Test strips may be stored at room temperature for up to 60 days. Controls may be stored at room temperature for up to 30 days. 2. Remove control seal by pulling tab. 4. To avoid the danger of injuries, it is recommended to always wrap a cloth or gauze tightly around the vial before squeezing it. Squeeze to break glass capsule. DO NOT BEND vial. Bending may cause glass to cut through the exterior wall of the vial. The capsule must break. 5. Start a timer for two and a half minutes. While timer runs, immediately tap vial HARD on table top ten times to mix contents. 6. Lay control on table for the rest of the two and a half minutes. 3. Tap vial to settle glass capsule to bottom of vial. 7. At the end of two and a half minutes, turn the monitor ON. 8. When the test strip icon flashes, open test strip pouch and remove test strip. 8 9

Liquid Quality Control Testing Liquid Quality Control Testing 9. Insert test strip. The test strip icon appears and the clock icon flashes. 12. Discard the first drop of control solution into cap. Discard cap with drop. 13. Apply the second drop of control solution to test strip. Avoid introducing air bubbles into the sample. A hanging drop must be formed on the bottle tip before applying the sample to the test strip. 10. Once the flashing blood drop icon appears, shake contents of vial down to dropper end. Shake down hard. Approximately three minutes should have elapsed since breaking the glass ampule. 14. Monitor beeps as it detects the drop. Do not disturb test strip while testing. Wait for result. Control result, followed by a c, appears in the display. Compare result to Control Value sheet. 11. With dropper end down, remove cap. 15. Remove test strip and dispose of control vial and test strip according to proper infection control guidelines. 16. Turn monitor off if you are finished testing. 10 11

Memory Changing Result Units Note: This procedure changes both the test results as well as the results stored in memory to the selected unit(s). You also have the option to switch from single unit display to dual unit display. See the User s Manual for specific instructions on dual unit display. 1. Place the monitor on a level surface and turn it on. 2. When the test strip icon flashes on the display, press the SET button located at the back of the monitor. The monitor enters the Set mode. 3. Press the SET button until the primary unit line flashes. 4. Press the Mem button to select the primary units. 5. Press the SET button. The secondary unit line flashes. 6. Press the Mem button to select the secondary units. 7. Press the SET button. 8. Turn the monitor off. Reviewing Memory Place monitor on a flat surface and turn it on. Wait for the flashing test strip icon to appear. Press the Mem button. The monitor stores the last 60 results in memory, along with the time and date. The most recent result is displayed first. Use the Mem button to scroll through the monitor s memory. The control test results are followed by a c. Turn the monitor off. 12

COAGUCHEK is a trademark of Roche. The CoaguChek S system (monitor and test strips) and its use are covered by one or more of the following U.S. Patents: 4,849,340; 5,110,727; 5,164,598; 5,300,779; 5,522,255; 5,710,622; 5,789,664; 5,792,944; and 5,886,252. The CoaguChek S monitor and its use are covered by one or more of the following U.S. Patents: 5,053,199; 5,526,111; 5,792,944; 5,841,023; and 5,886,252. The CoaguChek test strips are covered by U.S. Patent No. 5,488,816; and 5,975,153. 2005 Roche Diagnostics. All rights reserved. 12137909003-0705 Our medical professionals are ready to answer your questions, 24 hours a day, 7 days a week, 365 days a year. Call Roche Diagnostics Technical Service Center at 1-800-428-4674. Roche Diagnostics 9115 Hague Road Indianapolis, IN 46256 www.coaguchek.com