References PRECISE DISSECTION MINIMAL THERMAL INJURY ELECTRICAL SILENCE IMPROVED PATIENT OUTCOMES. Advancing surgical possibilities

Similar documents
Ferromagnetic Dissection: A Comparison to Electrosurgery

ISOCOOL Bipolar Forceps

Lotus transducer Instructions for use

VirtuoSaph Plus. Endoscopic Vessel Harvesting System. Designed for Safety and Efficiency

INNOVATION. Harmonic INSPIRED BY TRADITION. HARMONIC FOCUS + Long Shears with Adaptive Tissue Technology

A revolutionary instrument designed for procedures requiring critically precise temperature control to reduce sticking and charring while

An In-Depth Examination of Radiofrequency Assisted Liposuction (RFAL)

Icon specifications. Handpiece compatibility

Cochlear Implants. Medical Procedures. for MED EL Implant Systems. AW33290_2.0 (English US)

lectrosurgery Accessories A comprehensive range of electrosurgery accessories for use with Eschmann electrosurgery units 05/16

Robotic thoracic surgery of total thymectomy

Driving performance, delivering versatility. Spetzler -Malis and SILVERGlide Non-Stick Bipolar Forceps

Arisa Ortiz, MD Director, Laser and Cosmetic Dermatology Assistant Clinical Professor Department of Dermatology UC San Diego

Treat Your Patients Better

Cochlear Implants. Medical Procedures. for MED EL CI Systems. AW33290_5.0 (English US)

New ATMOS RS 221 ENT. Now with automatic. thermal cut-out

Integra. Limit uncertainty by simplifying operation and maximizing performance with NXT Digital Architecture

How do you use the AiM Vascular Mapping Kit?

AccuracyMatters. Ultrasonic surgical aspiration system

FEB-2015 ISSUE. Dr. David Pudukadan

Bipolar Radiofrequency Energy

Clinical Decision Making. Haneul Lee, DSc, PT

Beaver-Visitec International. Ophthalmic and Microsurgical Product Catalog

Spine surgery with ultrasonic technology by Söring: maximum safety thanks to extreme precision.

Spine surgery with ultrasonic technology by Söring: maximum safety thanks to extreme precision

MORE EFFICIENT TONSILLECTOMIES 1-4,

Challenges in Rapid Evaporative Ionization of Breast Tissue: a Novel Method for Realtime MS Guided Margin Control During Breast Surgery

WHITE PAPER. Thermo-Optically Powered (TOP ) Surgery. Advances in Surgical Techniques. By Felix Feldchtein, Ph.D. Gregory B. Altshuler, Ph.D., D.Sc.

Grazedean Ltd. bipolar scissors. bipolar double joint instruments. function by design

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

Radiofrequency surgery

SUPER INDUCTIVE SYSTEM

REAL NON-STICK BIPOLAR FORCEPS & MICRO MONOPOLAR FORCEPS

CLINICAL EVALUATION REPORT ON THE EFFICACY AND SAFETY OF THE CORE SYSTEM FOR FACIAL ENHANCEMENT TREATMENTS

TissueMend. Arthroscopic Surgical Technique. Arthroscopic Insertion of a Biologic Rotator Cuff Tissue Augment After Rotator Cuff Repair

SPECIAL TOPIC. AboutSkin Dermatology & DermSurgery, Greenwood Village, CO b. The Aesthetic Clinique, Destin, FL c

Ultrasound Guided Peripheral Intravenous Access

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

Diabetic Foot Ulcers. A guide to help minimise pain, trauma and stress

TRANSANAL ACCESS PLATFORM

Studies Confirm Exilis Elite s Advantages for Tightening and Shaping

EVOLUTION. in Electrosurgery

Superior RF Multi-Treatment Platform

Ablation Lesion Assessment

QUESTIONS OF NEUROSURGERY

Superior RF Multi-Treatment Platform

A Smarter Way To Sculpt. Frequently Asked Questions

A Never Obsolete Face and Body Platform

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

Alper Toker, MD. VATS decortication. Istanbul University, Istanbul Medical School Department of Thoracic Surgery

Chapter 23 Unit 28. Therapeutic Modalities

Neurosurgery with ultrasonic technology by Söring: accurate preparation and effective aspiration.

Bipolar Resection Solution Systems

SPECIAL TOPIC. Cosmetic Dermatology Center, McLean, VA b. Art of Skin, MD, Solana Beach, CA c. Dermatology Associates, Seattle, WA

Service for Clinical Applications Responsible for Life

Easier minimally invasive technology to deliver the optimal vessel for CABG.

Maximize Safety in Trendelenburg

Department of Dermatology Faculty of Medicine Siriraj Hospital, Mahidol University Bangkok, THAILAND

Paolo Giorgio Arcidiacono MD FASGE

The right options for any turbinate anatomy. Explore our full portfolio of turbinate reduction options designed to address any anatomic situation.

What Determines Aortic False Lumen Growth Post Dissection?

A COMPARATIVE STUDY OF COLD AND HOT TONSILLECTOMY

Very versatile tool for minor cosmetic procedures High frequency AC radiowaves generate cellular heat Cells vaporised Radiowaves pass through the

INGUINAL HERNIA REPAIR PROCEDURE GUIDE

High Intensity Focused Ultrasound Facial Skin Lifting

Er:YAG Laser-in-Handpiece

English. New impulse in electrosurgery

SARASOTA MEMORIAL HOSPITAL

JuggerKnot Soft Anchor 1.0 mm Mini

Your Subcutaneous Implantable Cardiac Defibrillator (ICD)

DORO. NON-STICK Bipolar Forceps. DORO Simply Better Built Simply More Choices.

Focused Ultrasound Body-shaping system Beijing Sanhe Beauty S & T Co.,Ltd

Source: Physical Agents in Rehabilitation from Research to Practice, 4 th edition, by Michelle Cameron.

New Cardiac Technologies. Melva Meminger MSN, RN, CCRN

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

EndoBlade Soft Tissue Release System

Gross and histologic characteristics of laparoscopic injuries with four different energy sources

8/28/18. Anesthetic considerations for patients with implanted devices for treating chronic pain and more. Objectives:

Electrosurgery made simple

Mako Partial Knee Patellofemoral

Electrosurgery made simple

XSIGHT LUNG TRACKING SYSTEM

Soft tissue biopsy needles

New Energy Sources for Local Ablation Therapy. Jeong Kyong Lee, MD Ewha Womans University

THERAPEUTIC USE OF ULTRASOUND PURPOSE POLICY STATEMENTS INDICATIONS CONTRAINDICATIONS. To describe the safe use of ultrasound therapy

RF Ablation: indication, technique and imaging follow-up

SYSTEM OVERVIEW MINIMALLY INVASIVE ROBOTIC LASER THERMOTHERAPY

Negative Pressure Wound Therapy

DermaLock Surgical Procedure step-by step Stefan Jansson D

Soft tissue biopsy needles

OptiFix Absorbable Fixation System

Electrosurgery. marcut THE BIPOLAR KLS MARTIN SCISSORS FOR USE IN OPEN SURGERY

Ultrasound Guided HIFU Ablation (USgFUS)

Bone Graft Harvesting System. Surgical Technique

MULTI PLATFORM SOLUTION FOR FEMININE HEALTH CONCERNS

Simply Complete. VA-LCP Elbow Plating System.

SONOPET Ultrasonic Aspirator Product catalog

JuggerKnot Soft Anchor 1.0 mm Mini

Transcription:

References A precise hemostatic dissection instrument that cuts and coagulates soft tissue without passing electrical current through the patient. 1. Internal data on file. 2. MacDonald, J.D., Bowers, C.A., Chin, S.S. et al. Comparison of the effects of surgical dissection devices on the rabbit liver. Surg Today (2014) 44: 1116. doi:10.1007/s00595-013-0712-4 PRECISE DISSECTION produces a precise, surface-only thermal effect with tactile control and minimal tissue drag, even through dense adhesions and tumors. The clean dissection results in clear margins for reliable pathology specimens. 3. Weiss, J. Peter Manwaring, Preston et al. Freedom from electromagnetic interference between cardiac implantable electronic devices and the ferromagnetic surgical system. Journal of Clinical Anesthesia, Volume 25, Issue 8, 681 684. 4. Shinkawa T, Holloway J, Tang X, Gossett JM, Imamura M. A ferromagnetic surgical system reduces phrenic nerve injury in redo congenital cardiac surgery. Interact CardioVasc Thorac Surg 2017; doi:10.1093/icvts/ivw444. 5. Retrospective Cohort Study Comparing Redo Operations Using Ferromagnetic Dissection and Conventional Monopolar Dissection. Joanne P. Starr, MD, Richard N. Gates, MD, Brian A. Palafox, MD, Allison Quill, RN, BSN. Surgical Innovation Vol 23, Issue 5, pp. 511 514 MINIMAL THERMAL INJURY imparts as little as 1/10th the thermal injury compared to monopolar electrosurgery, with as few as 80 microns (0.08 mm) of thermal spread in some tissue types.1,2 6. Bowers, Christian A. et al. Comparison of tissue effects in rabbit muscle of surgical dissection devices. International Journal of Surgery, Volume 12, Issue 3, 219 223 7. Comparison of ferromagnetic induction and bipolar electrosurgery and suction in corticotomies in pig cerebrum, Bowers, Christian A. et al. International Journal of Surgery, Volume 16, 55-59 ELECTRICAL SILENCE No electrical current passes through tissue. No grounding pad is used, and no spark, arcing, or stray current is produced. Surgeons using the report no generation of cardiac dysrhythmia, and no interference with electrophysiological monitoring, ultrasound imaging, cochlear implants, or CIEDs.1,3 IMPROVED PATIENT OUTCOMES Reduction of injury to nerves4 Less unintended damage to tissue2 leading to reduced use of blood products during surgery5 Less post-operative edema and drainage5,7 Domain Surgical and are registered trademarks of Domain Surgical, Inc. All content is copyright of Domain Surgical, Inc. 2017. Visit www.omni-guide.com/patents for information about the coverage of this product by U.S. and/or foreign patent rights. LB-045 Rev. C 888.666.4484 617.551.8444 customerservice@omni-guide.com www.omni-guide.com Advancing surgical possibilities

PRECISE DISSECTION produces a precise, surface-only thermal effect with tactile control and minimal tissue drag, even through dense adhesions and tumors. The clean dissection results in clear margins for reliable pathology specimens. MINIMAL THERMAL INJURY imparts as little as 1/10th the thermal injury compared to monopolar electrosurgery, with as few as 80 microns (0.08 mm) of thermal spread in some tissue types. 1,2 ELECTRICAL SILENCE No electrical current passes through tissue. No grounding pad is used, and no spark, arcing, or stray current is produced. Surgeons using the report no generation of cardiac dysrhythmia, and no interference with electrophysiological monitoring, ultrasound imaging, cochlear implants, or CIEDs. 1,3 IMPROVED PATIENT OUTCOMES Reduction of injury to nerves 4 Less unintended damage to tissue 2 leading to reduced use of blood products during surgery 5 Less post-operative edema and drainage 5,7

is an intelligent thermal dissection device that precisely cuts and coagulates with a fraction of the tissue injury compared to monopolar electrosurgery 1,2, without passing any electrical current through the patient. 1,3 Non-stick precision dissection tips available in a variety of shapes and sizes to meet the most exacting requirements Onboard microprocessor continuously monitors and adjusts delivery of thermal energy 200 times per second Dissection tips activate instantly and cool in seconds 180 rotating tips available in 100 mm and 150 mm lengths FMmax mode for uniform hemostatic dissection in all soft tissue types FMmin mode for fine dissection, spot cautery, and pre-treating vessels Certain models are available with an integrated smoke evacuation feature. is a component of the FMX Ferromagnetic Surgical System.

PRECISE DISSECTION Tactile control with minimal tissue drag Predictable, char-free layer-by-layer dissection with optimal visualization of tissue planes Precise dissection in all soft tissues, including muscle and adipose, even in wet environments Effective dissection through dense adhesions and tumors Incision Margins: Histologic analysis of comparative incisions in rabbit liver using monopolar electrosurgery (left - Coag 40 Watts) and (right - 60 Watts). Incisions made with monopolar electrosurgery produce extreme variability, while the produces consistently uniform margins. 2 MINIMAL THERMAL INJURY Imparts as little as 1/10th the thermal injury compared to monopolar electrosurgery 1 As few as 80 microns (0.08 mm) of thermal spread in some tissue types 2 Clear margins for reliable pathology specimens Surgeons note less unintended damage to tissue, leading to reduced use of blood products during surgery, and less post-operative edema and drainage 5,7 Breadth of Thermal Injury: Comparative incisions were made in pig liver at equal depth using both monopolar electrosurgery (left - Coag 40 Watts) and the (right - 60 Watts). Histology data were analyzed to measure the exact depth of incision (thick black line), the area of collateral thermal injury (orange area), and lateral thermal spread shown in the table below. Lateral Thermal Spread 2 Brain: Liver: 80 microns (0.08 mm) 100 microns Area of Thermal Injury Undamaged Tissue Undamaged Tissue Muscle: 200 microns (0.20 mm) Monopolar electrosurgery routinely imparts over 1,500 microns (1.5 mm) of lateral thermal spread in various tissue types.

ELECTRICAL SILENCE No potentially dangerous electrical current passes through tissue No grounding pad is used No spark, arcing, or stray current produced Electromagnetic Interference: The ECG chart to the left shows electromagnetic interference caused when using monopolar electrosurgery (top), and no interference when using the (bottom) during the same surgery. 1 Surgeons and anesthesiologists report no generation of dysrhythmia, and no interference with electrophysiological monitoring, ultrasound imaging, cochlear implants, or CIEDs 1,2 IMPROVED PATIENT OUTCOMES Post-Operative Indicators: To test the impact of minimized collateral tissue damage on a body s natural healing response, 3 pigs underwent bifrontalparietal craniotomies with 2 cm linear incisions through cortex into white matter at a depth of 8 mm using both the traditional bipolar forcep/suction dissection method (left) and the (right). MR imaging was completed 1.5 hours post procedure to measure the edema depth surrounding the incision. Bipolar/Suction The incision made by the demonstrated about 1/2 the edema depth in brain tissue compared to the incision made with bipolar/suction. 7 Healing Studies: Incisions were made in rabbit paraspinous muscle using monopolar electrosurgery (left) and the (right) to compare healing characteristics. Histologic analysis was performed 14 days later. After 14 days, the incision made with the exhibited evidence of markedly superior healing compared to the incision made with monopolar electrosurgery. 6

References 1. Internal data on file. 2. MacDonald, J.D., Bowers, C.A., Chin, S.S. et al. Comparison of the effects of surgical dissection devices on the rabbit liver. Surg Today (2014) 44: 1116. doi:10.1007/s00595-013-0712-4 3. Weiss, J. Peter Manwaring, Preston et al. Freedom from electromagnetic interference between cardiac implantable electronic devices and the ferromagnetic surgical system. Journal of Clinical Anesthesia, Volume 25, Issue 8, 681 684. 4. Shinkawa T, Holloway J, Tang X, Gossett JM, Imamura M. A ferromagnetic surgical system reduces phrenic nerve injury in redo congenital cardiac surgery. Interact CardioVasc Thorac Surg 2017; doi:10.1093/icvts/ivw444. 5. Retrospective Cohort Study Comparing Redo Operations Using Ferromagnetic Dissection and Conventional Monopolar Dissection. Joanne P. Starr, MD, Richard N. Gates, MD, Brian A. Palafox, MD, Allison Quill, RN, BSN. Surgical Innovation Vol 23, Issue 5, pp. 511 514 6. Bowers, Christian A. et al. Comparison of tissue effects in rabbit muscle of surgical dissection devices. International Journal of Surgery, Volume 12, Issue 3, 219 223 7. Comparison of ferromagnetic induction and bipolar electrosurgery and suction in corticotomies in pig cerebrum, Bowers, Christian A. et al. International Journal of Surgery, Volume 16, 55-59 Domain Surgical,, and FMsealer are registered trademarks of Domain Surgical, Inc. All content is copyright of Domain Surgical, Inc. 2017. Visit www.omni-guide.com/patents for information about the coverage of these products by U.S. and/or foreign patent rights. LB-073 Rev. A Distributed by Lawmed Ltd. Russell House, Molesey Road Hersham, KT12 3PJ. United Kingdom T: +44 (0)845 241 1510 F: +44 (0)845 241 1520 E: enquiries@lawmed.co.uk www.lawmed.co.uk ADVANCING SURGICAL POSSIBILITIES