You succeed your root canal treatments! Characteristics...page 4. Instruments...page 6. Protocol...page 10. Questions & Answers...

Similar documents
Safety and Simplicity!

Endo Easy Efficient. The efficient NiTi system. User Information.

Instructions for use: FlexMaster. the rotary NiTi-System for every case. Endo Easy Efficient

Endodontics. Patented partial heat treatment Improved safety

ENDO-EZE TM GENIUS ENDODONTIC SYSTEM WHERE SAFETY MEETS EFFICIENCY

WHERE SAFETY MEETS EFFICIENCY

Race family Endodontic NiTi rotary files

Endo Easy Efficient. The efficient NiTi system. Power in Control.

SINGLE FILE SYSTEM FOR MODERN ENDODONTICS SMART CONTRA-ANGLE HANDPIECE WITH RECIPROCATING MOTION

One Flare For a safer endo

Endo Easy Efficient. Single File Root Canal Preparation.

Innovative revolutionary approach to root canal preparation

Endodontics. Endodontic retreatment

Endo Easy Efficient one file endo

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

irace Quick, effective and safe

A great file. Even better.

one file endo Endo Easy Efficient

flexible performance Chemin du Verger 3 CH-1338 Ballaigues Switzerland

XP-endo Shaper. The One to Shape your Success

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

EndoWave. Enhanced safety for root canal preparation. Thinking ahead. Focused on life.

MICRO-MEGA INDEX. Endodontics. Obturation. Handpieces and Contra-Angles. Surgery Implantology. Air Programme. Hygiene. Maintenance.

Creating a glide path for rotary NiTi instruments: part two

Rooter S. Compact, Cordless Endodontic Motor

TriAuto mini Compact, Cordless Endodontic Handpiece

K3 Nickel-Titanium Files

Buy Direct. Buy Brasseler USA. Systems for Endodontic Excellence. R a Ce T M. Rotary Endodontic System with Safety Memo Disc. RaCe TM.08. RaCe TM.

Instructions For Use

Tools for Endodontic Success

KaVo Endodontic Program. Finger-tip feel for sensitive movements.

Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals

Instruments used in Endodontics

ENDODONTICS ENDODONTICS

ANATOMIC. XP-endo Finisher. optimal cleaning while preserving dentine

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

S5 Rotary Files. only. Manufacturer. Packing unit. Batch code. For professional use only (0)

Minimally Invasive Endodontics for Better and Safer Treatment

ENDODONTICS ENDODONTICS

Celebrating 30th Anniversary of DiaDent Specialized GUTTA PERCHA & PAPER POINTS REFERENCE GUIDE

Root Canal Treatment. with a mechanical treatment system. Clinical case

Endo Easy Efficient. one file endo. The RECIPROC Technique Steps to Success.

LegacyENDO. Create your own Legacy! Controlled Memory Cross Cut. Apex Access. Multi Taper. K-Files

Endo Easy Efficient.

1) INDICATIONS FOR USE These products have to be used only in hospital environments, clinics or dental offices by qualified dental personnel.

ProUltra ULTRASONIC SURGICAL TIPS

Case report for the new HyFlex CM NiTi File system of Coltene Endo

Field Guide to the Ultrasonic Revolution

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

Three-Dimensional, Dense and Durable Obturation of Root Canals

endodontics 88 MARCH 2013» dentaltown.com feature by Kenneth Koch, DMD and Ali Nasseh, DDS, MMSc

AlphaKite System. Mechanical preparation of root canals with nickel-titanium files

Totally lightweight, totally flexible, totally titanium.

ProUltra Ultrasonic Non Surgical Endo Tips

Case Note Retrieval of a separated file using Masserann technique: A case report

Advanced ESX Instrumentation:! Segmental Crown Down & Hybridization of Tapers!

People have Priority. Endodontics

Maxdent s.r.o.,ondračka Martin,tel:

Torsion Property and Cyclic Fatigue Fracture Behavior of. Nickel-Titanium Endodontic Instruments

Simple. Stress-free. The Newtron Ultrasonics Series

Root end preparation techniques Summary of papers

Use and description of endodontic instruments

BS EN ISO 14971: Risk Analysis and Risk Management Report

Classic Technique Guide

Our special deals spring & summer. valid until 31st of July vdw-dental.com

FS MTS. Micro Periodontal Tissue Scissors

Influence of cervical preflaring on apical file size determination - An in vitro study

Improve Your Root Canal Preparations with Adaptive Motion Technology

Our special deals spring & summer. valid until 31st of July vdw-dental.com

5/8/2012. Endodontics. Root Canal Preparation Root Canal Filling. Coronal Access. Isolation. Follow-up. Diagnosis

People have Priority. Endodontics

in simulated curved canals

Before we begin demonstrating the shock of paradigms on the instrumentation

Restoration & Prosthetics. Quieter, asts longer NEW

UNICLIP DIRECTIONS FOR USE REF C226U - 0,8 MM / 1 MM FOR DENTAL USE ONLY. FISDR / F EN / 11 / updated 06/2016 1/7

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

Effective cleaning and shaping of the root

Luxator. Design By Dentists. By DIRECTA

SWISS INSTRUMENTS PM

SWISS INSTRUMENTS PM

ORIGINAL ARTICLE INTRODUCTION

Shah. Management of a maxillary second premolar with an S-shaped root canal - An endodontic. Management of a maxillary second premolar

Shaping ability of progressive versus constant taper instruments in curved root canals of extracted teeth

CBCT Evaluation Of Glidepath Preparation By Different Rotary Nickel Titanium Glide Path...

IN VITRO EVALUATION OF ROOT CANAL PREPARATION WITH TWO ROTARY INSTRUMENT SYSTEMS PRO TAPER AND HERO SHAPER

Û MECTRON ULTRASONIC INSERTS

THE WORLD'S FIRST CORDLESS ULTRASONIC ENDO ACTIVATION DEVICE. Patent pending USA Engineered and Manufactured SCIENTIFIC EVIDENCE SUPPORTS SEE WHY

THE WORLD'S FIRST CORDLESS ULTRASONIC ENDO ACTIVATION DEVICE. Patent pending USA Engineered and Manufactured

Failure of ProFile instruments used with air, high torque control, and low torque control motors

Virtuosity is in your hands. Endodontic and Microsurgical Ultrasonic Instruments

Morita Endodontic Equipment. Thinking ahead. Focused on life.

Comparison of the Different Techniques to Remove Fractured Endodontic Instruments from Root Canal Systems

EXTERNAL FIXATION SYSTEM

KING SAUD UNIVERSITY College of Dentistry. Department of Restorative Dental Sciences DIVISION OF ENDODONTICS COURSE OUTLINE 323 RDS

Working length changes following straight-line access and different coronal flaring methods

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

ENDO- DONTICS ENDODONTIC THERAPY

Last Generation Endodontic Instruments. A Study of their. Drs. Siragusa and Racciatti are affiliated with the Department of

INSTRUCTIONS FOR USE AND CARE

A Collection of High Quality Orthodontic Instruments

Transcription:

We invent HERO Shaper. You succeed your root canal treatments! Summary Characteristics...page 4 Instruments...page 6 Protocol.....page 10 Questions & Answers...page 16 Clinical cases...page 19 2

Introduction Using HERO Shaper for orthograde treatment has never been quicker and simpler. Conditions such as irreversible pulp pathology, pulpitis and necrosis are easily managed using the HERO Shaper rotary nickel - titanium instruments at low speed. HERO Shaper files, with their pronounced tapers, are designed for use with the crown-down technique to progressively remove constraints and flare the canal. The coronal third is prepared using.06 taper HERO Shaper files and the apical third is prepared using.04 taper HERO Shaper files. The varying helical pitch and length of the cutting portion of the files provide them with an excellent combination of efficiency and flexibility. Using continuously rotating HERO Shaper files along the entire length of the root canals with circumferential filing optimises preparation. Cleaning is much more efficient because the progressive flaring of the canal as the instrument is introduced allows the irrigation needle to be inserted down to the apical third. Regular, tapered preparations with the resulting enlargement of the apical zone (no.30.04 taper) facilitate the adjustment and insertion of the gutta-percha master cone. It also ensures that the root canal system is filled completely and tightly by condensation of the filling material. Developed in 2001 by the MICRO-MEGA R&D Department, the HERO Shaper line is now available in an InGeT version like the R-Endo canal retreatment instruments. 3 MICRO-MEGA HERO Shaper

HERO Shaper An innovative pitch! Avoids screwing effects: the helical angle of the cutting edges varies from the tip to the shank. The new pitch also varies according to the taper: the more tapered an instrument is, the longer is its pitch; This can be described as an ADAPTED PITCH. Increased instrument performance: Efficiency / Flexibility / Strength. 4% 4% 6% 6% 4

A positive advance in root canal preparation The blade shows a triple helix cutting edge. The tip is inactive in order to follow the canal anatomy. Positive rake angle for excellent debris evacuation. This root canal treatment method is faster and allows: Improved patient comfort. Time saving: 10 seconds of use per instrument for efficient shaping. Reduced operator fatigue. Less instruments to handle. Reproducible results. Increased safety: - no screwing effect, - excellent debris evacuation. SEM view of the tip of a n 25.04 taper HERO Shaper Big inner core for excellent resistance to breakage. Anti Breakage Control: the instrument unwinds to prevent the risk of fracture. 3 edges for better force balance. See conditions of use page 18 5 MICRO-MEGA HERO Shaper

Innovative InGeT (Integrated Gear Technology) 1 Actual size Miniaturized head. Ergonomics. Visibility. Accessibility. The HERO Shaper line is available with InGeT shafts to be fitted on the micro head InGeT contra-angle 2 concepts: the choice and with Classics shafts (Ø 2.35) to be fitted on an endo reducing contra-angle (AX S Endo for instance). 2 Classics AX'S Endo contra-angle 6

instruments HERO Shaper InGeT series Blue.06 taper - n 30 Black rubber stop Blue.04 taper - n 30 Grey rubber stop Red.06 taper - n 25 Black rubber stop Red.04 taper - n 25 Grey rubber stop Yellow.06 taper - n 20 Black rubber stop Yellow.04 taper - n 20 Grey rubber stop 16 mm 21 or 25 mm 12 mm 21, 25 or 29 mm 16 mm 21 or 25 mm 12 mm 21, 25 or 29 mm 16 mm 21 or 25 mm 12 mm 21, 25 or 29 mm 7 MICRO-MEGA HERO Shaper

Innovative

instruments HERO Shaper Classics series Blue.06 taper - n 30 Black rubber stop Blue.04 taper - n 30 Grey rubber stop Red.06 taper - n 25 Black rubber stop Red.04 taper - n 25 Grey rubber stop Yellow.06 taper - n 20 Black rubber stop Yellow.04 taper - n 20 Grey rubber stop 16 mm 21 or 25 mm 12 mm 21, 25 or 29 mm 16 mm 21 or 25 mm 12 mm 21, 25 or 29 mm 16 mm 21 or 25 mm 12 mm 21, 25 or 29 mm 9 MICRO-MEGA HERO Shaper

Instrumentation sequences Protocol Yellow sequence Difficult canals, severely curved, possibly with significant hypercalcification, making any first penetration tricky with the finest hand files. Red sequence Canals of average difficulty with a moderate curvature and/or more hypercalcification, making first penetration with a n 10 K file hard to achieve. Blue sequence Easy canal preparation, low curvature, orifice and canal large enough to allow a n 15 K file to reach the apex. 10

according to canal type Rotation speed The rotation speed must be 300 to 600 rpm. First penetration The first penetration is performed with a conventional hand instrument (usually a n 10 K file-mmc n 10/21 mm). This is used to confirm the working length (WL), canal anatomy and diagnosis from the pre-operative X-ray. Canal mineralisation and curvature will determine the treatment difficulty and thus the most suitable instrumentation sequence for the clinical case. 6% 2/3 WL Penetration levels.06 taper files are brought to 2/3 of the working length. 04 taper files are brought to WL. An accurate determination of the working length between the passage of the.06 and.04 file is strongly recommended. Operating procedure HERO Shaper is positioned at the canal entrance. The motor is started and maintained at constant speed whilst the file is working and until it is completely withdrawn from the canal. The file is inserted to the desired working length with a short in and out movement using light pressure. HERO Shaper also allows circumferential filing to be achieved which permits the canal anatomy to be taken into account and in particular to shape lateral zones. Irrigation It is important to thoroughly irrigate the canal between the passage of successive instruments. 4% WL 11 MICRO-MEGA HERO Shaper

yellow 6% 4% 4% 4% 6% 4% 4% 4% 1 n 20 -.06 taper Bring the HERO Shaper n 20 -.06 taper to the 2/3 of WL. 2 n 20 -.04 taper Bring the HERO Shaper n 20 -.04 taper to WL. 12

sequence Complex cases 6% 4% 4% 4% 6% 4% 4% 4% 3 n 25 -.04 taper Bring the HERO Shaper n 25 -.04 taper to WL. 4 n 30 -.04 taper Bring the HERO Shaper n 30 -.04 taper to WL. 13 MICRO-MEGA HERO Shaper

Red sequence Intermediate cases 6% 4% 4% 6% 4% 4% 6% 4% 4% 1 n 25 -.06 taper Bring the HERO Shaper n 25 -.06 taper to the 2/3 of WL. 2 n 25 -.04 taper Bring the HERO Shaper n 25 -.04 taper to WL. 3 n 30 -.04 taper Bring the HERO Shaper n 30 -.04 taper to WL. 14

Blue sequence Simple cases 6% 4% 1I n 30 -.06 taper Bring the HERO Shaper n 30 -.06 taper to the 2/3 of WL. 6% 4% 2 n 30 -.04 taper Bring the HERO Shaper n 30 -.04 taper to WL. 15 MICRO-MEGA HERO Shaper

Questions & Answers What are the benefits of the InGeT system? A miniaturized head Very compact head: 6.5 mm diameter and 7.5 mm high. Increased visibility of the operative field. Better visibility of the instrument when it is inserted in the canal and a better vision of the instrument while working. This is particularly useful when treatment is made under magnification (magnifying loupe or microscope). Considerable reduction of the total length of the instrument + contra-angle head in the mouth. Exceptional working comfort. Reduced visibility Traditional contra-angle Wide visibility InGeT contra-angle Actual size Ergonomics Excellent stability in the hand. Straight handle as an extension of the hand: Better tactile sensitivity. Easy access to the operating field. Better access to posterior teeth. Increased working accuracy. A head angle especially designed for an excellent visibility and easier work in the most difficult access zones. Extremely simple head mechanism: Less interfaces more reliability. Reduced maintenance. Less vibration. Greater ease of cleaning. Increased safety. 16

Questions & Answers When should I confirm the working length? An initial estimation of the WL can be determined based on the pre-operative X-ray and after the first penetration of the N. 10 K file (MMC). After this, the HERO Shaper.06 file can be safely used to prepare the coronal third of the canal. Once most of the interferences have been eliminated, the WL can be determined with greater precision and the HERO Shaper.04 file can be safely used to prepare the apical third. How do I measure the WL? WL is measured using an apex locator such as Apex Pointer and/or a pre-operative X-ray. Is it necessary to pass a hand MMC file between each HERO Shaper? Passing a small-tip-diameter manual file (N 10 or 15) between each HERO Shaper makes it possible to determine whether dentine chips or pulp debris are blocking the canal. The use of a hand file is mainly recommended for difficult cases, especially fine canals. Should I verify apical patency? If so, how? Apical patency should be verified at the end of the preparation. A slightly pre-curved hand MMC N 10 file is especially suitable, generally sufficient and non aggressive for this procedure. Should I always follow the recommended sequences? You do not necessarily have to follow the recommended sequences, but it is preferable to do so. However, when an operating difficulty has been over or underestimated, the preparation sequence may be changed for one that uses a sequence of instruments that is better adapted to the difficulty. Is the rotation speed of great importance? HERO Shaper files, like all Ni-Ti preparation instruments, are used at a low rotation speed. The choice of speed is left to the practitioner, but must be between 300 and 600 rpm. It is, however, very important that the rotation speed remains constant and regular. Why the adapted pitch? The concept of the adapted pitch used for HERO Shaper files involves varying the length of the pitch or the cutting portion as a function of taper. The resulting instruments are thus very flexible and perfectly adapted to the work required of them. Why is there no.02 taper as with the HERO 642 system? Since HERO Shaper files are very flexible, a file with a.04 taper can be introduced down to the apical limit with no danger of deviation, which increases the flare of the canal and thus facilitates cleaning and filling. Is there any risk of screwing effect with highly tapered instruments? No, because the increased pitch of the.04 taper instrument considerably reduces the screwing risk. What should I do if I want to widen a large canal beyond n 30? If the canal is straight, the preparation can be continued down to the apex with a.06 file. If not, specific instruments must be used, i.e., HERO Apical files. 17 MICRO-MEGA HERO Shaper

Questions & Answers Why is the use of a torque control contra-angle or motor unnecessary? A torque control contra-angle or motor is used to limit torque. In the event of major constraints, for example when the instrument is forced or becomes stuck, the rotation stops. Since the design of the HERO Shaper files makes them very resistant to breakage, using a torque control contra-angle or motor is not necessary. In addition, the Anti Breakage Control allows the instrument to unwind in the event apical blockage occurs, considerably reducing the need for torque control. Should I clean the grooves between two passages? Yes. When the grooves are loaded with debris and sludge, HERO Shaper files are much less efficient. In addition, the risk of unwinding rises because the debris-filled grooves prevents the cutting edges from working efficiently. How should I clean the grooves of the HERO Shaper files? You can clean the HERO Shaper between two passages using a compress soaked in a sodium hypochlorite solution. How many sterilisation cycles can HERO Shaper files withstand? Metal fatigue of HERO Shaper files is caused more by the number of times the files are used than by the number of sterilisation cycles, so long as the recommended sterilisation conditions, time and temperature are respected. How many canals can I treat with a HERO Shaper file? From 6 to 10 canals can generally be treated with a single HERO Shaper file. However, major constraints can cause premature metal fatigue, which is most often seen with the unwinding of the grooves (Anti Breakage Control). It is thus essential to comply with the recommended technique and, especially, to avoid any pressure on the head of the contra-angle causing unwinding. It is also important to scrupulously check the files after cleaning and sterilisation. Instruments that show signs of wear and unwinding should be discarded. Why the HERO Shaper are not multi-tapered instruments? The HERO Shaper system is designed for use with the crown-down technique to progressively remove interferences and flare the canal. The system is made up of files with different tapers, each of which is designed for a specific use, i.e., to prepare a specific portion of the canal. Thus, progressive flaring of the canal is achieved. This limits the screw in phenomenon, which generates high stresses and can lead to instrument breakage. Can HERO Shaper files be used for endodontic retreatment (ERT)? HERO Shaper files are not designed for ERT. Their great flexibility means they can be used to prepare any canal, even the most difficult. However, they are not designed to deal with the stresses encountered when ERT is performed. The R-Endo files, on the other hand, are designed specifically for ERT. Drawings: C. RONCHINI. SEM photos: Dr. M. GUIGAND - Equipe Biomatériaux en Site Osseux, UMRCNRS6511, France. Unwound instrument should not be used as it will likely result in the breakage of the instrument. MICRO-MEGA cannot be held liable for any breakage caused by abnormal use of the instrument. 18

Clinical Cases Case 1 Canal treatment of a second lower molar (37). The debridement technique takes account of the flared form of the coronal half. Case 2 Pulpectomy and endodontic treatment of the upper right molar (17) that respect the initial canal axis perfectly. Pre-operative X-ray Post-operative X-ray Pre-operative X-ray Post-operative X-ray Case 3 Endodontic treatment of a second lower left molar. The curve in the apical portion of the mesial canal was negotiated without difficulty. The apical third was flared using a HERO Apical.06 and.08 sequence. Pre-operative X-ray Post-operative X-ray Clinical cases: Prof. Paul CALAS. 19 MICRO-MEGA HERO Shaper

MICRO-MEGA s products HERO Shaper ENDOFLARE Classics ENDOFLARE InGeT InGeT Endodontics Hand instruments. Rotary NiTi systems Handpieces and contra-angles Obturation Air Programme Motors. Turbines. Couplers Hygiene Turbocid HERO Shaper Classics R-Endo HERO Apical InGeT 08/06. Ref 60301517. - MICRO-MEGA reserves the right to modify the characteristics of its instruments without notice. HERO Apical Classics MICRO-MEGA France Distribution 5-12 rue du Tunnel F - 25006 BESANÇON cedex Tel.: +33 (0)3 81 54 42 36 - Fax: +33 (0)3 81 54 42 39 MICRO-MEGA International Distribution 133 rue de Genève CH - 1226 THÔNEX Tel.: +41 (0)22 860 85 30 - Fax: +41 (0)22 860 85 31 commercial@micro-mega.com mmid@micro-mega.com www.micro-mega.com