Chlamydia trachomatis

Similar documents
Chlamydia trachomatis

BEIPH Final Report. EQA Programme 2011 Chlamydia trachomatis (CTDNA11A) William G Mackay on behalf of QCMD and its Scientific Council April 2011

BEIPH Final Report. EQA Programme 2011 Chlamydia trachomatis B (CTDNA11B) Prepared on behalf of QCMD and its Scientific Council October 2011

FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION CLINICAL BIOLOGY SECTION

Hepatitis C Virus (RNA)A

B19 Virus EQA Programme Final Report QAV (B19DNA14)

BEIPH Final Report. QCMD 2009 Neisseria gonorrhoeae (NGDNA09) EQA Programme

QUALITY CONTROL for MOLECULAR DIAGNOSTICS Quality issues highlighted through international external quality assessment

Fifteen years of molecular EQA: progress and challenges

DEFINITIVE GLOBAL ANNUAL REPORT Molecular Biology Microbiology 2015

Research Article External Quality Assessment for the Detection of Chlamydia trachomatis in Urine Using Molecular Techniques in Belgium

UPDATE MOLECULAR DIAGNOSTICS IN SEXUAL HEALTH. Dr Arlo Upton Clinical Microbiologist Labtests Auckland

Controls for Chlamydia trachomatis and Neisseria gonorrhoea

Controls for Chlamydia trachomatis and Neisseria gonorrhoea

Scottish Bacterial Sexually Transmitted Infections Reference Laboratory (SBSTIRL) User Manual Jan 2018

DETECTION OF NEISSERIA GONORRHOEAE USING MOLECULAR METHODS

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2018Oct26

New CT/GC Tests. CDC National Infertility Prevention Project Laboratory Update Region II May 13-14, 2009

BACTERIOLOGY PROFICIENCY TESTING PROGRAM

Performance of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acid amplification assays using low level controls

Technical Bulletin No. 98b

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2017Oct27

BACTERIOLOGY PROFICIENCY TESTING PROGRAM

2014 CDC GUIDELINES CHLAMYDIA & GONORRHEA DIAGNOSTICS. Barbara Van Der Pol, PhD, MPH University of Alabama at Birmingham

Development of a NIST Standard Reference Material for Cytomegalovirus

Programme Groupings. For 2013, the preliminary molecular external quality assessment (EQA) programme schedule has been displayed by Disease Group.

HPV Testing What are EQAS and QC data telling us?

The use of QCMD proficiency testing panels in clinical virology.

AMPLIRUN TOTAL A RELIABLE QUALITY CONTROL SOURCE FOR NUCLEIC ACID TESTS

6/11/15. BACTERIAL STDs IN A POST- HIV WORLD. Learning Objectives. How big a problem are STIs in the U.S.?

Results of the College of American Pathologists (CAP) Proficiency Program for CMV, EBV, and BKV Viral Load Testing

Laboratory for Clinical and Biological Studies, University of Miami Miller School of Medicine, Miami, FL, USA.

Commercial Assays an Overview. Molecular Workshop

4. RED AND BLUE TOP COLLECTION SWABS WILL NO LONGER BE SUPPLIED FOR BACTERIAL CULTURE

LABORATORY VALIDATION OF XPERT CT/NG AND TV TESTING AS PERFORMED BY NURSES AT THREE PRIMARY HEALTHCARE FACILITIES IN SOUTH AFRICA

New HIV Tests and Algorithm: A change we can believe in

Evaluation of the Abbott RealTime CT/NG Assay in Comparison to the Roche Cobas Amplicor CT/NG Assay

Quality Management 333 Liam Whitby 1.2 Liam Whitby 24-Jul Jul-2016 unknown

RealLine Mycoplasma genitalium Str-Format

Industry Sponsored Symposia. Québec City, CANADA JULY 10 TO 13,

on the road to harmonisation?

Diagnostic Methods of HBV infection. Zohreh Sharifi,ph.D of Virology Research center, Iranian Blood Transfusion Organization (IBTO)

CHLAMYDIA/GC AMPLIFIED RNA ASSAY

DX CT/NG/MG AUTO ASSAY

Guidelines for the Laboratory Detection of Chlamydia trachomatis, Neisseria gonorrhoeae and Treponema pallidum Testing

Reliable, cost-effective CT/GC testing For labs with low to medium throughput needs. The BD ProbeTec ET System

Update from ISS on following EQA studies: ISS EQA Tri-NAT (HCV, HIV and HBV) 2012 ISS EQA NAT HBV 2012 ISS EQA NAT WNV 2012

VQA HIV DNA Control SOP Version 5.0 HIV DNA Testing 13 March 2012

Trends in molecular diagnostics

2018 HIV and HCV Diagnostic Testing Survey

Menu and flexibility with the QIAscreen HPV PCR Test

Guidance on the use of molecular testing for Neisseria gonorrhoeae in Diagnostic Laboratories 2011

Validation of a Laboratory Developed Real-Time PCR Protocol for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Urine

Instructions for Use. RealStar Influenza Screen & Type RT-PCR Kit /2017 EN

1 VU University Medical Centre, Department of Medical Microbiology & Infection Control, Laboratory of

FINAL REPORT HBV Serology External Quality Assessment Scheme

Comparison of Three Nucleic Acid Amplification Tests for Detection of Chlamydia trachomatis in Urine Specimens

Neonatal Pneumonia-2 assay

Be sure! Your Power for Health. PelvoCheck CT/NG Your test kit for Chlamydia trachomatis screening and Neisseria gonorrhoeae infections

Performance of the Abbott RealTime CT/NG for the Detection of Chlamydia. trachomatis and Neisseria gonorrhoeae

PERFORMANCE OF THE COBAS CT/NG TEST COMPARED TO THE APTIMA AC2

Prevalence of human papillomavirus and bacteria as sexually transmitted infections in symptomatic and asymptomatic women

Molecular Diagnosis Future Directions

Performance of the Abbott RealTime CT/NG for Detection of

WHO recommendations. Diagnostic testing in infants

NIH Public Access Author Manuscript Sex Transm Infect. Author manuscript; available in PMC 2013 June 04.

Instructions for Use. RealStar Influenza S&T RT-PCR Kit /2017 EN

Evaluation of CDC-Recommended Approaches for Confirmatory Testing of Positive Neisseria gonorrhoeae Nucleic Acid Amplification Test Results

Product # Kit Components

FINAL REPORT HBV Serology External Quality Assessment Scheme

HBV PUBLIC HEALTH IMPLICATIONS

Rare pitfalls associated with the routine use of real time PCR

Diagnostic Methods of HBV and HDV infections

Schedule of Accreditation

CDC Laboratory Update

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP)

for Microbiology Quality Assessment Programmes for HPV and MRSA Effect of change to assessment categories for HBV DNA Dr Vivienne James SoGAT 2009

Leukemia BCR-ABL Fusion Gene Real Time RT-PCR Kit

MolecularMD. One-Step qrt-pcr BCR-ABL Kit. Product Description and User Manual. For Quantitative RT-PCR Analysis of BCR-ABL. Contact Us.

Innovations in nucleic acid amplification technologies. Automated platforms for NAT. Microfluidics Digital PCR Innovations in nucleic acid microarrays

Performance of the Abbott Real Time CT/NG assay in urines and cervicovaginal samples from Senegal

Xpert CT/NG. Detect it in here. Stop it out there. Three targets, 90 minutes. No repeat testing. Xpert CT/NG. Xpert. A better way.

Multilaboratory Evaluation of Real-Time PCR Tests for Hepatitis B Virus DNA Quantification

HTLV Serology Quality Assessment Program Summary for Panel HTLVSER 2017Apr19

About HPV. Human papillomavirus (HPV) is a group of viruses that are extremely common worldwide. Theree are more than 100 types of HPV, of which at

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Abbott RealTime HIV-1 (m2000sp) Number: PQDx

Assessment of co-infection of Sexually Transmitted pathogen microbes by

Bioruptor DNA QC kit. Track the efficiency of your Bioruptor Pico. Cat. No. C

Consolidated Donor Funded Procurement of HIV Diagnostics

Nucleic Acid Amplification Testing for the Diagnosis of TB

Integrating HIV Screening Into

July VQAAB Minutes VQA Advisory Board (VQAAB) Members

NRL EQAS for NAT: Assessing the variability and performance of molecular assays for clinical pathogens

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for use with the PrimePCR Reverse Transcription Control Assay

CALIBRATION OF ANALYTICAL STANDARDS FOR HBV-DNA, HCV-RNA AND HIV-1 RNA IN GENOME COPIES BY A REFERENCE METHOD

Panther has new prey

Microsart Calibration Reagent

HIV Serology Quality Assessment Program Revised Summary for Panel HIVSER 2017Oct27

Testing Railway Safety Critical Workers for Drugs and Alcohol

Transcription:

Chlamydia trachomatis 2012 EQA Programme A Final Report QAB004101 (CTDNA12A) Dr Anton M van Loon Scientific Experts on behalf of QCMD Report authorised by the QCMD Executive in May 2012 A UKAS accredited proficiency testing provider (no. 4385) Not to be reproduced or quoted without permission of QCMD. Any queries about this report should be addressed to the QCMD Neutral Office. Unit 5, Technology Terrace, Todd Campus, West of Scotland Science Park, Glasgow, G20 0XA, Scotland Tel: +44 (0)141 945 6474, Fax: +44 (0)141 945 5795, Email: info@qcmd.org, Web: www.qcmd.org

Percentage of datasets 2012 Chlamydia trachomatis A 1. Programme aims To determine the qualitative performance of participants testing for Chlamydia trachomatis (C. trachomatis) using molecular technologies. To determine the incidence of false positive results and to compare performance with previous distributions. Participants are encouraged to read the QCMD Participants' Manual, which can be downloaded from the QCMD website. Any queries about this report should be addressed to the QCMD Neutral Office (neutraloffice@qcmd.org). 2. Programme details CTDNA12A Date of panel distribution 06/02/2012 Number of respondents 236 (97%) Number of participants 244 Number of datasets submitted 263 Number of countries 33 Number of qualitative datasets submitted 260 (99%) Number of qualitative and quantitative datasets submitted Eight participants did not return results. Three of these withdrew officially, citing 'assay not offered' (n=2) and 'technical issues' (n=1). 3 (1%) 3. Panel composition content * matrix conc.** Copies/vial status type CTA12-05 C. trachomatis Urine 4,000 1,000 Frequently detected Core CTA12-03 C. trachomatis Urine 1,000 250 Detected Core CTA12-04 C. trachomatis Urine 250 63 Detected CTA12-01 C. trachomatis Swedish Variant Urine 2,000 500 Detected CTA12-02 Ct. negative urine Urine Negative Core CTA12-07 C. trachomatis Sim. Swab 6,250 1,563 Frequently detected Core CTA12-06 C. trachomatis Sim. Swab 1,250 313 Frequently detected Core CTA12-08 C. trachomatis Sim. Swab 250 63 Detected Core CTA12-10 C. trachomatis Sim. Swab 50 13 Detected CTA12-09 Ct. negative swab Sim. Swab Negative Core : QCMD panel sample codes for the samples distributed to participants. content: bacterial content of the panel samples. matrix: material used as a matrix in preparation of the panel samples. conc.: consensus values calculated from all of the data returned by participants, once outliers had been removed. The values are not technology specific and should not be used by participants for method comparison or as a target for individual laboratory assessment. status: the sample status assigned to each panel sample. Please see Appendix A for more information. type: panel samples classified as core proficiency samples. *Urine: Chlamydia trachomatis-negative urine collected from healthy adult volunteers. Sim. Swab: containing 1/10 dilution of TE buffer designed to simulate a clinical swab sample when reconstituted with sample transport medium. ** The EQA panel consisted of five lyophilized urine samples that participants were instructed to reconstitute with 4.0 ml of water, and 5 lyophilized simulated swab samples that participants were instructed to reconstitute with 4.0ml of their CT transport medium for swabs. 4. Programme results 4.1. Qualitative performance on the core proficiency samples 100.0% 90.0% 80.0% 70.0% 60.0% 50.0% 40.0% 30.0% 20.0% 10.0% 0.0% 87.5% 6.5% 4.9% 0.4% 0.8% 0.0% 0.0% 0.0% 7/7 6/7 5/7 4/7 3/7 2/7 1/7 0/7 Number of core samples correct The QCMD EQA panels contain a range of samples, designed to look at different aspects of assay performance. Panel members are designated core proficiency samples on the basis of scientific information, clinical relevance and clinical experience (published literature and professional clinical guidelines) and, where available and appropriate, established target performance limits taken from previous QCMD EQA distributions. Laboratories are expected to correctly analyse and report the core proficiency samples in order to show acceptable proficiency. 2 of 7 www.qcmd.org

4.2. Qualitative analysis of the EQA data for all panel samples The number (percentage) of correct qualitative results are presented below. Qualitative data were returned by participants as 'positive', 'negative' or 'not determined'. Not determined results were counted as incorrect for all panel samples (positive or negative). QCMD organises datasets according to commercial and in-house technology groups, which are Conventional PCR, Real time PCR, NASBA, SDA, TMA and bdna. Where datasets were reported as other for a technology or kit method this was reviewed by the QCMD Neutral Office and assigned to an appropriate group where possible. Table i: Number of correct qualitative results per panel member and technology type conc. content datasets n=263 n=16 n=5 n % n % n % n % n % n % n % CTA12-05 C. trachomatis 1,000 256 97.3 15 93.8 4 80.0 167 98.8 23 95.8 23 95.8 24 96.0 CTA12-03 C. trachomatis 250 248 94.3 15 93.8 4 80.0 163 96.4 22 91.7 21 87.5 23 92.0 CTA12-04 C. trachomatis 63 175 66.5 10 62.5 1 20.0 118 69.8 19 79.2 14 58.3 13 52.0 CTA12-01 C. trachomatis Swedish Variant 500 181 68.8 5 31.3 3 60.0 119 70.4 21 87.5 16 66.7 17 68.0 CTA12-02 Ct. negative urine 257 97.7 15 93.8 4 80.0 169 100.0 22 91.7 24 100.0 23 92.0 CTA12-07 C. trachomatis 1,563 263 100.0 16 100.0 5 100.0 169 100.0 24 100.0 24 100.0 25 100.0 CTA12-06 C. trachomatis 313 258 98.1 16 100.0 4 80.0 168 99.4 23 95.8 22 91.7 25 100.0 CTA12-08 C. trachomatis 63 245 93.2 16 100.0 3 60.0 161 95.3 22 91.7 18 75.0 25 100.0 CTA12-10 C. trachomatis 13 191 72.6 12 75.0 3 60.0 132 78.1 16 66.7 7 29.2 21 84.0 CTA12-09 Ct. negative swab 260 98.9 16 100.0 5 100.0 169 100.0 23 95.8 24 100.0 23 92.0 PCR Total Conventional Real time SDA f TMA g Commercial a In-house b Commercial c In-house d n=169 n=24 n=24 n=25 Table ii: Qualitative performance scores per technology type Total PCR All technologies Conventional Real time SDA f TMA g status Commercial a In-house b Commercial c In-house d n=263 n=16 n=5 n=169 n=24 n=24 n=25 0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3 CTA12-05 Frequently detected 256 0 0 7 15 0 0 1 4 0 0 1 167 0 0 2 23 0 0 1 23 0 0 1 24 0 0 1 CTA12-03 Detected 248 0 15 0 15 0 1 0 4 0 1 0 163 0 6 0 22 0 2 0 21 0 3 0 23 0 2 0 CTA12-04 Detected 175 0 88 0 10 0 6 0 1 0 4 0 118 0 51 0 19 0 5 0 14 0 10 0 13 0 12 0 CTA12-01 Detected 181 0 82 0 5 0 11 0 3 0 2 0 119 0 50 0 21 0 3 0 16 0 8 0 17 0 8 0 CTA12-02 Negative 257 0 0 6 15 0 0 1 4 0 0 1 169 0 0 0 22 0 0 2 24 0 0 0 23 0 0 2 CTA12-07 Frequently detected 263 0 0 0 16 0 0 0 5 0 0 0 169 0 0 0 24 0 0 0 24 0 0 0 25 0 0 0 CTA12-06 Frequently detected 258 0 0 5 16 0 0 0 4 0 0 1 168 0 0 1 23 0 0 1 22 0 0 2 25 0 0 0 CTA12-08 Detected 245 0 18 0 16 0 0 0 3 0 2 0 161 0 8 0 22 0 2 0 18 0 6 0 25 0 0 0 CTA12-10 Detected 191 0 72 0 12 0 4 0 3 0 2 0 132 0 37 0 16 0 8 0 7 0 17 0 21 0 4 0 CTA12-09 Negative 260 0 0 3 16 0 0 0 5 0 0 0 169 0 0 0 23 0 0 1 24 0 0 0 23 0 0 2 Key to Table i and ii : QCMD panel sample codes for the samples distributed to participants. content: bacterial content of the panel samples. conc.: consensus values calculated from all of the data returned by participants, once outliers had been removed. The values are not technology specific and should not be used by participants for method comparison or as a target for individual laboratory assessment. Total datasets: number and percentage of datasets reporting the correct qualitative result for each panel sample. status: the sample status assigned to each panel sample. Please see Appendix A for more information. Total. All technologies: number of datasets awarded each score (0 to 3). A breakdown of the results for all datasets is also provided based on technology type. a: Hain Lifescience GenoQuick CT (n=1), Roche Amplicor CT/NG (n=4), Roche COBAS Amplicor CT/NG (n=8), Sacace Chlamydia trachomatis 330/740 IC (n=1), Seeplex STI Master ACE Detection (n=2). b: Details not presented. c: Abbott RealTime CT (n=5), Abbott RealTime CT/NG (n=40), ABI Chlamydia trachomatis RG detect (n=1), BD ProbeTec CT Qx Amplified DNA Assay (n=1), Bio-Rad Dx CT/NG/MG Assay (n=1), Diagenode Dia-CT/NG-050 (n=9), GeneProof Chlamydia Trachomatis PCR Kit (n=2), Goffin Presto CT-NG assay (n=4), IAB C. trachomatis RG detect (n=3), Minerva Biolabs Onar Ct qpcr Kit (n=1), Nanogen Chlamydia tr. Q-PCR Alert Kit (n=5), QIAGEN artus C. trachomatis PCR Kit (TM) (n=2), QIAGEN artus C. trachomatis Plus PCR Kit (LC) (n=5), QIAGEN artus C. trachomatis Plus PCR Kit (RG) (n=7), Roche cobas 4800 CT/NG Test (n=37), Roche COBAS TaqMan CT Test v2.0 (n=34), Sacace N. gonorrhoeae/c. trachomatis/t. vaginalis/m. genitalium Real-TM (n=1), Seegene Anyplex CT/NG Real-time Detection (n=1), Seegene Anyplex II STI-7 Detection Assay (n=1), Seegene Seeplex STD6 ACE Detection (n=4), Siemens Versant CT/GC DNA 1.0 assay (n=2), TIB MOLBIOL LightMix Kit (n=3). d: Details not presented. f: BD Diagnostics BD ProbeTec ET System (n=7), BD Diagnostics Viper ProbeTec ET (n=2), BD Probetec ET CT/GC Amplified DNA Assay (n=6), BD Probetec ET CT/GC/AC Amplified DNA Assay (n=9). g: Gen-Probe APTIMA Combo 2 Assay (n=19), Gen-Probe APTIMA CT Assay (n=6). 3 of 7 www.qcmd.org

4.3. Qualitative analysis of the EQA data by assay target gene Participants were asked to specify the target gene of their assay when submitting their results. Out of the 263 datasets received by QCMD 255 (97%) contained information on the target gene. conc. content Total datasets Cryptic plasmid Cryptic plasmid + other target n=263 n=127 n=94 n % n % n % n % n % n % n % CTA12-05 C. trachomatis 1,000 256 97.3 123 96.9 94 100.0 25 96.2 5 100.0 2 66.7 7 87.5 CTA12-03 C. trachomatis 250 248 94.3 119 93.7 93 98.9 24 92.3 4 80.0 2 66.7 6 75.0 CTA12-04 C. trachomatis 63 175 66.5 82 64.6 71 75.5 14 53.8 2 40.0 1 33.3 5 62.5 CTA12-01 C. trachomatis Swedish Variant 500 181 68.8 85 66.9 67 71.3 18 69.2 2 40.0 1 33.3 8 100.0 CTA12-02 Ct. negative urine 257 97.7 124 97.6 94 100.0 24 92.3 5 100.0 3 100.0 7 87.5 CTA12-07 C. trachomatis 1,563 263 100.0 127 100.0 94 100.0 26 100.0 5 100.0 3 100.0 8 100.0 CTA12-06 C. trachomatis 313 258 98.1 124 97.6 94 100.0 26 100.0 5 100.0 2 66.7 7 87.5 CTA12-08 C. trachomatis 63 245 93.2 116 91.3 91 96.8 26 100.0 3 60.0 2 66.7 7 87.5 CTA12-10 C. trachomatis 13 191 72.6 93 73.2 67 71.3 21 80.8 3 60.0 2 66.7 5 62.5 CTA12-09 Ct. negative swab 260 98.9 126 99.2 94 100.0 24 92.3 5 100.0 3 100.0 8 100.0 n=26 n=5 Other* n=3 Not reported : QCMD panel sample codes for the samples distributed to participants. content: bacterial content of the panel samples. conc.: predefined specifications for QCMD internal purposes only. Values should not be used by participants for method comparison or as a target for individual laboratory performance assessment. Total datasets: number and percentage of datasets reporting the correct qualitative result for each panel sample. A breakdown of the results for all datasets is also provided based on target gene. * 16S and ompa (n=1), inca AF276502 (n=1), pmph Gene (n=1). rrna ompa n=8 4.4. Quantitative results per laboratory Three participants provided quantitative results; these are shown below content conc. (copies/ml) Summary statistics (log 10 ) Mean SD %CV Lab a Lab a Lab b ii dataset 1 i copies/ml dataset 2 i copies/ml copies/ml CTA12-05 C. trachomatis 1,000 2.528 0.651 25.7 152 133 1,900 CTA12-03 C. trachomatis 250 2.016 0.852 42.3 32 35 1,000 CTA12-04 C. trachomatis 63 0.874 0.589 67.3 7 2 30 CTA12-01 C. trachomatis Swedish Variant 500 1.719 0.397 23.1 33 29 150 CTA12-07 C. trachomatis 1,563 3.385 0.886 26.2 845 665 25,500 CTA12-06 C. trachomatis 313 2.616 0.678 25.9 160 176 2,500 CTA12-08 C. trachomatis 63 1.887 0.654 34.7 26 41 430 CTA12-10 C. trachomatis 13 1.389 0.910 65.5 6 9 272 : QCMD panel sample codes for the samples distributed to participants. content: bacterial content of the panel samples. conc.: predefined specifications for QCMD internal purposes only. Values should not be used by participants for method comparison or as a target for individual laboratory performance assessment. Summary statistics (log10): the mean, standard deviation and coefficient of variation expressed as a percentage are presented. These values were calculated from the log concentration of participants results. The following assays were used. i: QIAGEN artus C. trachomatis PCR Kit (TM) ii: Real time in-house PCR on the ABI PRISM 7900 HT. 4 of 7 www.qcmd.org

5. Comments General observations The number of participants in the 2012 QCMD Chlamydia trachomatis (CT) A EQA programme increased by 9.4% from 223 in 2011A to 244 in this EQA programme. The majority of datasets were generated using commercial kits, with only 11.0% (n=29) of datasets utilising inhouse assays. PCR was the dominant technology in this EQA programme, with 81.4% datasets returned using this technique. The majority of PCR datasets were generated using real time PCR assays (90.2%; n=193). Of the real time PCR datasets 87.6% were generated using commercially developed kits. Qualitative performance All core samples were detected by 87.5% of participants. This is an increase on the 80.5% of the datasets that detected all core samples in the 2011 CT A EQA programme. The 2012 CT A EQA panel contained dilution series containing Chlamydia trachomatis in both urine and simulated swab. Most participants (over 90%) were able to detect all but the lowest concentration samples in both dilution series. Little difference in performance was observed based on technology group, although both in-house and commercial real time PCR assays look to have performed slightly better than other technology groups particularly on the lowest concentration samples in both dilution series. Four not determined and two false positive results (0.7%) were reported on the negative urine panel sample CTA12-02. One not determined and two false positive results (0.7%) were also reported on the negative simulated swab panel sample CTA12-09. This gives an overall false positivity of (0.7%) which compares favourably to the percentage of false positive results reported in the 2011A C. trachomatis EQA programme (1.1%). Results for the Swedish variant Chlamydia trachomatis Panel sample CTA12-01 contained the Swedish variant (Ripa et al: 2007) of C. trachomatis at lower concentration. For most technology groups the percent range of correct positive results was between 60% and 90%. For Conventional Commercial PCR technologies it was much lower at only 31.3%, however this does represent a continued improvement on previous EQA programmes. Results by assay target gene The most commonly used target gene in datasets received by QCMD was the cryptic plasmid (n=127; 49.8%) only, or in combination with another target gene (n=88; 36.7%). This represents an increase in the proportion of datasets returned using another target gene as well as the cryptic plasmid. No major differences in performance were observed between assay targets genes used. Analysis of the quantitative EQA data Only three quantitative datasets were returned to QCMD which did not allow full quantitative analysis. Individual quantitative results returned to QCMD are presented in section 4.5. Although the numbers of quantitative results remains low (2010: n=3) this area may develop in the future. The variability in the quantitative results returned indicates that the availability of EQA and reference materials will be of value in the establishment of quantitative assays. References Ripa T, Nilsson PA. A Chlamydia trachomatis strain with a 377-bp deletion in the cryptic plasmid causing false-negative nucleic acid amplification tests. Sexually Transmitted Diseases, 2007; 34(5):255-256. Acknowledgements Data analysis and report generation were performed by the QCMD Neutral Office. QCMD 2012. The QCMD EQA programme samples, associated reports and data generated during this programme are intended for External Quality Assessment (EQA) and Proficiency Testing (PT) purposes only. QCMD operates according to a strict Code of Practice which is in line with ISO/IEC 17043 and associated standards. Data reported in QCMD programmes is representative of a laboratory s standard diagnostic testing protocols irrespective of the technology they use. The data provided in the reports are based on technical information provided by the individual laboratories as part of the assessment process, as such it does not constitute a formal technology method comparison. All text and images produced by QCMD are the property of QCMD unless otherwise stated. The reproduction and use of these materials is not permitted without the express written consent of QCMD. The use of the information provided in QCMD reports for commercial purposes is strictly prohibited. 5 of 7 www.qcmd.org

Appendix A Assigning the sample status status is assigned by peer-group consensus, based on the qualitative results returned by all participants. It is not a measure of the 'strength' of a positive sample nor is it technology-dependent, and is used solely for the scoring of the EQA data. The rationale for the sample status is: Frequently detected: More than 95% of datasets recorded the correct positive result. Detected: Between 65% and 95% of datasets recorded the correct positive result. Infrequently detected: Less than 65% of datasets recorded the correct positive result. Negative: A panel sample that does not contain the target and produces an unequivocal negative result. Scoring system for qualitative EQA data The scores awarded for qualitative EQA data were based on the sample status. The scoring system is represented in the following table, where 0 is 'highly satisfactory' and 3 is 'highly unsatisfactory'. Colour has been included as an extra visual aid. Scoring system based on the assigned sample status status Participant's result Negative Not determined Positive Frequently detected 3 3 0 Detected 2 2 0 Infrequently detected 1 1 0 Negative 0 3 3 6 of 7 www.qcmd.org

Appendix B: Manufacturers' Section All commercial manufacturers of molecular diagnostic assays are encouraged to independently test the EQA panel and present the results of their own analysis of the EQA panel in this section of the report. The information and data are provided independent of QCMD and at the sole discretion and liability of the assay manufacturer. The "manufacturers' section" is intended to provide EQA users of a particular commercial manufacturer's assay with additional information and is based on data and information supplied independent of the QCMD EQA process. Whilst every effort has been made to ensure that the content of this section of the report is both reliable and accurate, QCMD advises that the information should not be relied upon in any way as representing a comprehensive description of the commercial manufacturer's assay and that users should discuss this detail directly with the manufacturer concerned. QCMD also advises that it cannot guarantee, and assumes no legal liability or responsibility for, the accuracy, reliability or completeness of the information contained within this section of the report. B.1.1. Panel results provided by Roche Molecular Systems Roche Molecular Systems, Pleasanton, CA tested the QCMD CTDNA12A EQA panels and a summary of their qualitative results is provided in Table B1. The results from all EQA participant laboratories are presented for comparison. B.1.2. Qualitative analysis of the EQA data The number (percentage) of correct qualitative results is presented in Table B1. Qualitative data were returned as 'positive', 'negative' or 'not determined'. Not determined results were counted as incorrect for all panel samples (positive or negative). Table B1: Number of correct qualitative results per panel member and technology type Total content matrix conc. datasets type n=263 Total Roche datasets Roche technologies Cobas 4800 a Cobas TaqMan b Cobas Amplicor c results d n=83 n=37 n=34 n=12 n=1 n % n % n % n % n % n % CTA12-05 C. trachomatis Urine 1,000 Core 256 97.3 83 100.0 37 100.0 34 100.0 11 91.7 1 100.0 CTA12-03 C. trachomatis Urine 250 Core 248 94.3 83 100.0 37 100.0 34 100.0 11 91.7 1 100.0 CTA12-04 C. trachomatis Urine 63 175 66.5 59 71.1 32 86.5 20 58.8 6 50.0 1 100.0 CTA12-01 C. trachomatis Sv Urine 500 181 68.8 49 59.0 32 86.5 15 44.1 1 8.3 1 100.0 CTA12-02 Ct. negativ e urine Urine Core 257 97.7 83 100.0 37 100.0 34 100.0 11 91.7 1 100.0 CTA12-07 C. trachomatis Sim. Swab 1,563 Core 263 100.0 84 101.2 37 100.0 34 100.0 12 100.0 1 100.0 CTA12-06 C. trachomatis Sim. Swab 313 Core 258 98.1 84 101.2 37 100.0 34 100.0 12 100.0 1 100.0 CTA12-08 C. trachomatis Sim. Swab 63 Core 245 93.2 82 98.8 36 97.3 33 97.1 12 100.0 1 100.0 CTA12-10 C. trachomatis Sim. Swab 13 191 72.6 62 74.7 27 73.0 25 73.5 9 75.0 1 100.0 CTA12-09 Ct. negativ e swab Sim. Swab Core 260 98.9 84 101.2 37 100.0 34 100.0 12 100.0 1 100.0 Roche Key to Table B1 : QCMD panel sample codes for the samples distributed to participants. content: bacterial content of the panel samples. matrix: material used as a matrix in preparation of the panel samples. conc.: predefined specifications for QCMD internal purposes only. Values should not be used by participants for method comparison or as a target for individual laboratory performance assessment. type: panel samples classified as core proficiency samples. Total datasets: number and percentage of datasets reporting the correct qualitative result for each panel sample. Roche technologies: number and percentage of datasets Roche Molecular Systems technologies reporting the correct qualitative result for each panel sample a: Qualitative results returned by EQA participants using the Roche cobas 4800 CT/NG Test. b: Qualitative results returned by EQA participants using the Roche COBAS TaqMan CT Test v2.0. c: Qualitative results returned by EQA participants using the Roche COBAS Amplicor CT/NG Test. d: Qualitative results returned from Roche Molecular Systems using Roche cobas 4800 CT/NG Test. 7 of 7 www.qcmd.org