Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Similar documents
Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability

A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique

Radiobiological Impact of Acuros XB Dose Calculation Algorithm on Low-Risk Prostate Cancer Treatment Plans Created by RapidArc Technique.

Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick

Dosimetric and radiobiological impact of intensity modulated proton therapy and RapidArc planning for high-risk prostate cancer with seminal vesicles

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

VMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media

WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

Leila E. A. Nichol Royal Surrey County Hospital

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 3, 2014

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

IMRT Planning Basics AAMD Student Webinar

Dosimetric Comparison: Acuros XB vs AAA

Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

New Technologies for the Radiotherapy of Prostate Cancer

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

Verification of performance of Acuros XB Algorithm (AXB) Implemented on Eclipse Planning System

IMAT: intensity-modulated arc therapy

The bootstrap method to improve statistical analysis of dosimetric data for radiotherapy outcomes

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams

Linac Based SBRT for Low-intermediate Risk Prostate Cancer in 5 Fractions: Preliminary Report of a Phase II Study with FFF Delivery

Application of asi-kvcbct for Volume Assessment and Dose Estimation: An Offline Adaptive Study for Prostate Radiotherapy

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Evaluation of the Dynamic Arc-Therapy in Comparison to Conformal Radiation Therapy in Radiotherapy Patients

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Department of Radiotherapy & Nuclear Medicine, National Cancer Institute, Cairo University, Cairo, Egypt.

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Commission, Ganakbari, Savar, Dhaka, Bangladesh

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Clinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations

RapidArc vs Conventional IMRT for Head and Neck Cancer Irradiation: Is Faster Necessary Better?

International Multispecialty Journal of Health (IMJH) ISSN: [ ] [Vol-3, Issue-9, September- 2017]

To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence

Sanja Ognjenovic A PROJECT. submitted to. Oregon State University. University Honors College

Address for Correspondence: Department of Medical Physics, Khwaja Yunus Ali University, Enayetpur, Sirajgonj ,

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons

Monitor unit optimization in RapidArc plans for prostate cancer

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Relationship of segment area and monitor unit efficiency in aperture-based IMRT optimization

Development of a novel low-radiation-absorbent lok-bar to reduce X-ray scattering and absorption in RapidArc â treatment planning and dose delivery

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

Dosimetric Comparison of Intensity-Modulated Radiotherapy versus 3D Conformal Radiotherapy in Patients with Head and Neck Cancer

Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy

A dosimetric evaluation of VMAT for the treatment of non-small cell lung cancer

162 Popescu et al.: Couch gantry arc in partial breast 162

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)

Prostate Phantom. Guidelines for Planning and Treating the IMRT Prostate Phantom. Revised March 2014

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Baotian Huang 1, Lili Wu 1, Peixian Lin 2 and Chuangzhen Chen 1*

Abdulhamid Chaikh 1,2, Jacques Balosso 1,2. Introduction

The effect of body contouring on the dose distribution delivered with volumetric-modulated arc therapy technique

Volumetric Modulated Arc Therapy in a Large Body Habitus Patient with Left Breast Cancer: A Dosimetric Study

Radiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

Comparison of VMAT-SABR treatment plans with flattening filter (FF) and flattening filter-free (FFF) beam for localized prostate cancer

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Additional Questions for Review 2D & 3D

Editorial Process: Submission:11/14/2017 Acceptance:07/31/2018

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

RESEARCH ARTICLE. Aydin Cakir 1, Zuleyha Akgun 2 *, Merdan Fayda 1, Fulya Agaoglu 1. Abstract. Introduction

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical

Rectal dose and toxicity dosimetric evaluation for various beam arrangements using pencil beam scanning protons with and without rectal spacers

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

2013 American College of Radiology /13/$36.00

3D ANATOMY-BASED PLANNING OPTIMIZATION FOR HDR BRACHYTHERAPY OF CERVIX CANCER

Dose prescription, reporting and recording in intensity-modulated radiation therapy: a digest of the ICRU Report 83

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times

Optimization of RapidArc for Head-and-Neck Radiotherapy. Jessica Emily Salazar. Department of Medical Physics Duke University.

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

Normal tissue dose in pediatric VMAT Piotr Zygmanski

Range Uncertainties in Proton Therapy

Taeryool Koo 1, Jin-Beom Chung 2*, Keun-Yong Eom 1,2, Jin-Yong Seok 2, In-Ah Kim 1,2 and Jae-Sung Kim 1,2

Research Article An IMRT/VMAT Technique for Nonsmall Cell Lung Cancer

Transcription:

Chinese Journal of Cancer Original Article Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment Suresh Rana 1 and ChihYao Cheng 2 Abstract The volumetric modulated arc therapy (VMAT) technique, in the form of RapidArc, is widely used to treat prostate cancer. The full-single arc (f-sa) technique in RapidArc planning for prostate cancer treatment provides efficient treatment, but it also delivers a higher radiation dose to the rectum. This study aimed to compare the dosimetric results from the new partial-single arc (p-sa) technique with those from the f-sa technique in RapidArc planning for prostate cancer treatment. In this study, 10 patients with lowrisk prostate cancer were selected. For each patient, two sets of RapidArc plans (f-sa and p-sa) were created in the Eclipse treatment planning system. The f-sa plan was created using one full arc, and the p-sa plan was created using planning parameters identical to those of the f-sa plan but with anterior and posterior avoidance sectors. Various dosimetric parameters of the f-sa and p-sa plans were evaluated and compared for the same target coverage and identical plan optimization parameters. The f-sa and p-sa plans showed an average difference of ±1% for the doses to the planning target volume (PTV), and there were no clear differences in dose homogeneity or plan conformity. In comparison to the f-sa technique, the p-sa technique reduced the doses to the rectum by approximately 6.1% to 21.2%, to the bladder by approximately 10.3% to 29.5%, and to the penile bulb by approximately 2.2%. In contrast, the dose to the femoral heads, the integral dose, and the number of monitor units were higher in the p-sa plans by approximately 34.4%, 7.7%, and 9.2%, respectively. In conclusion, it is feasible to use the p-sa technique for RapidArc planning for prostate cancer treatment. For the same PTV coverage and identical plan optimization parameters, the p-sa technique is better in sparing the rectum and bladder without compromising plan conformity or target homogeneity when compared to the f-sa technique. Key words Prostate cancer, RapidArc, partial arc, volumetric modulated arc therapy (VMAT), planning technique Prostate cancer is the second most commonly diagnosed cancer among men in the United States after skin cancer [1]. Radiotherapy is one option for the management of prostate cancer. In recent years, the volumetric modulated arc therapy (VMAT) technique has been widely used to treat prostate cancer because VMAT allows the delivery of a conformal dose distribution to the PTV while minimizing the doses to nearby critical structures [2]. Furthermore, VMAT requires Authors Affiliations: 1 Department of Medical Physics, ProCure Proton Therapy Center, 5901 West Memorial Road, Oklahoma City, OK 73142, USA. 2 Department of Radiation Oncology, Vantage Oncology, San Fernando Valley Region, West Hills, CA 91307, USA. Corresponding Author: Suresh Rana, Department of Medical Physics, ProCure Proton Therapy Center, 5901 West Memorial Road, Oklahoma City, OK 73142, USA. Email: suresh.rana@gmail.com. doi: 10.5732/cjc.013.10077 a smaller number of monitor units (MUs) to deliver a given fraction size, and treatment can be completed in a shorter treatment time than that required for intensity-modulated radiation therapy (IMRT) [2-4]. RapidArc (Varian Medical Systems, Palo Alto, CA) is one such VMAT technique that can deliver treatments over one or several continuous arcs with the simultaneous adjustment of dose rate, gantry rotation speed, and multi-leaf collimator (MLC) field aperture [2,3]. Previous studies on RapidArc planning for prostate cancer treatment have mostly focused on comparing the dosimetric quality of treatment techniques, such as IMRT vs. RapidArc [5-11] and single arc (SA) vs. double arc (DA) [8-11] in RapidArc planning. The RapidArc treatment planning requires a trade-off between target coverage and the sparing of critical structures. Treatment planners can modify the plans by varying the weight factor for each target or critical structure during the optimization process. Additionally, dose-volume parameters can also be varied to meet the acceptable 546 CACA Chinese Anti-Cancer Association

dosimetric criteria. However, plan optimization may not produce the optimal plan, and the treatment planner may need to repeat the optimization. For example, if the treatment plan requires a reduction in the dose to the rectum, the planner will need to re-optimize the plan using either different beam parameters or an increased weight factor for the rectum, which may reduce the target coverage. Thus, treatment planning can require a trial-and-error process to find an optimal plan. Sze et al. [9] reported that although the SA technique for RapidArc planning for prostate cancer treatment could provide treatment efficiency, which is important for busy clinics with high patient throughput, it also delivers a higher dose to the rectum. It is essential to find more efficient methods for RapidArc planning using the SA technique while minimizing the radiation dose to critical structures such as the rectum and bladder. In this study, we investigated the feasibility of RapidArc planning using SA with anterior and posterior avoidance sectors on prostate cancer planning. The dosimetric quality of the new partial-single arc (p-sa) technique was compared with that of the full-single arc (f-sa) technique for the same target coverage and identical plan optimization parameters. Patients and Methods Patient selection We randomly selected 10 cases from the database of low-risk prostate cancer treated with external beam radiation therapy at West Hills Radiation Therapy Center, Vantage Oncology, California, USA between January 2012 and January 2013. Computed tomography (CT) simulation All patients underwent standard CT simulation, maintaining full bladder during the simulation process, and were immobilized in a Vac-Lok system (CIVCO Medical Solutions, Kalona, Iowa, USA). CT scans of 512 512 pixels and 0.25 cm slices were acquired using a GE LightSpeed CT Scanner (GE Healthcare, Milwaukee, WI, USA). After the CT simulation, Digital Imaging and Communications in Medicine (DICOM) CT images were transferred to the Varian Eclipse treatment planning system (TPS) for contouring and planning preparation. Contouring The clinical target volume (CTV) comprised of prostate and proximal seminal vesicles were contoured by a radiation oncologist on the axial CT images. The rectum, bladder, and femoral heads, defined as organs at risk (OARs), were delineated based on the axial CT images. The planning target volume (PTV) was generated from the CTV by a uniform expansion of 5 mm in all directions. dose of 1.8 Gy in 44 fractions. The planning parameters were set up using Varian standard scale in the Eclipse TPS (version 11.0.21) with Varian Clinac ix 6 MV X-ray beams (Varian Medical Systems, Palo Alto, CA, USA). For each patient, two sets of RapidArc plans (f-sa and p-sa) were created, and the isocenter was placed at the center of the PTV for both plans. First, the f-sa plan was created using one full arc in an anti-clockwise direction (arc angle: 1 359 ; collimator angle: 170 ) (Figure 1A). Then, the p-sa plan was created using parameters identical to those of the f-sa plan but with an anterior avoidance sector of 30 and a posterior avoidance sector of 60 (Figure 1B). Specifically, in the p-sa plan, the beam-on fraction was in the arc sections from 30 to 165 and from 195 to 330. Optimization Ten sets of plans (f-sa and p-sa) were inversely optimized using the Varian Eclipse Progressive Resolution Optimizer (PRO, version 11.0.21). To make fair comparisons between the f-sa and p-sa plans, a volumetric dose optimization template (Table 1) was created to ensure that at least 95% of the PTV received the prescription dose in 44 fractions while keeping the dose to OARs below the planning limits. For the rectum, the percent volume receiving 60 Gy, 65 Gy, 70 Gy, and 75 Gy (V 60Gy, V 65Gy, V 70Gy, and V 75Gy, respectively) was restricted to 50%, 35%, 25%, and 15%, respectively. For the bladder, the V 65Gy, V 70Gy, V 75Gy, and V 80Gy was restricted to 50%, 35%, 25%, and 15%, respectively. The mean dose to the femoral heads was limited to less than 30 Gy. No modifications of the dosevolume constraints or weightings were made during the optimization processes for either set of plans. Calculation and normalization The doses from optimized f-sa and p-sa plans were calculated with the Anisotropic Analytical Algorithm (AAA), version 11.0.21, in the Eclipse TPS, and the dose calculation grid was set to 2.5 mm for all cases. The calculated f-sa and p-sa plans were then normalized such that the prescribed dose covered at least 95% of the PTV. Evaluation The dose-volume histograms (DVHs) of normalized f-sa and p-sa plans were generated in the Eclipse TPS. For the PTV, the minimum dose, mean dose, maximum dose, conformity index (CI, defined in equation 1), and homogeneity index (HI, defined in equation 2) were compared. CI = V 95% (1), V PTV where V 95% is the total volume of the isodose cloud receiving 95% of the prescription dose, and V PTV is the volume of the PTV. Dose prescription and planning The total dose prescribed to the PTV was 79.2 Gy with a daily HI = D 5% D 95% (2), Chin J Cancer; 2013; Vol. 32 Issue 10 547

Full-single arc A B Arc angle: 1 0 359 0 Partial-single arc Figure 1. A transversal view of the RapidArc plan for prostate cancer using two planning techniques in the Eclipse treatment planning system (Varian Standard Scale). A, full-single arc (f-sa) with continuous beam-on time from arc angle 1 to 359. B, partial-single arc (p- SA) with beam-on time from arc angle 30 to 165 and from arc angle 195 to 330. The p-sa technique includes a posterior avoidance sector (60 ) and an anterior avoidance sector (30 ). PTV, planning target volume. Arc angle: 195 0 330 0 Table 1. Dose-volume constraints and weightings used for the optimization in RapidArc planning for prostate cancer treatment using the full-single arc (f-sa) and partial-single arc (p-sa) techniques Structure Optimization objective Volume (%) Dose (Gy) Weighting PTV Upper 0 81.5 250 Lower 100 80.5 250 Rectum Upper 0 78.0 85 Upper 15 7 85 Upper 35 6 85 Upper 50 5 85 Bladder Upper 0 78.0 80 Upper 15 75.0 80 Upper 35 65.0 80 Upper 50 6 80 Femoral heads Upper 0 55.0 80 Upper 10 5 80 PTV, planning target volume. Optimization objective corresponds to a point in the dose-volume data space. The upper and lower objectives represent the maximum and minimum limits, respectively, to the corresponding dose-volume histogram. 548 Chin J Cancer; 2013; Vol. 32 Issue 10 Chinese Journal of Cancer

where D 5% and D 95% are doses covering 5% and 95% of the PTV, respectively. For the rectum and bladder, the V 70Gy, V 50Gy, V 40Gy, V 20Gy, and the mean dose were compared between treatments. Additionally, the mean doses to the femoral heads and penile bulb, the integral dose, and MU values were compared for each set of plans. Dosimetric analysis For comparative purposes, the f-sa plans were used as the standard, and the average difference (D avg ) in the corresponding dosimetric parameter (for example, mean dose, V 70Gy, integral dose, and so on) between the f-sa and p-sa plans of the same case was calculated using equation 3. [ ] 1 (f-sa) D avg (X)= n -(p-sa) n 100 10 10 (f-sa) n=1 n (3), Where X is the corresponding dosimetric parameter in the f-sa and p-sa plans for the n th case. In equation 3, the D avg is expressed as a percentage and averaged over all 10 cases in this study. For a given dosimetric parameter in equation 3, a positive D avg implies a higher dosimetric value in the f-sa plans compared with the p-sa plans, and a negative D avg implies a higher dosimetric value in the p-sa plans compared with the f-sa plans. The statistical analysis was performed using the paired two-sided Student t test in a Microsoft Excel spreadsheet, and a P value < 5 was considered significant. Results Table 2 shows the results of the dosimetric parameters for the f-sa and p-sa plans, and the D avg of dosimetric parameters of the PTV, rectum, bladder, femoral heads, penile bulb, the integral dose, and MUs are shown in Figure 2. The results presented in Table 2 and Figure 2 are averages from the 10 analyzed cases. Patient characteristics The median age of the 10 patients was 69 years (range, 58 82 years). Their Gleason scores ranged from 6 to 7, and their prostatespecific antigen (PSA) levels ranged from 1.8 ng/ml to 12.7 ng/ml. The clinical stages of the 10 cases ranged from T1a to T2a. The average PTV, the average volumes of the rectum, bladder, femoral heads, and penile bulb were (125.3 ± 14.6) cm 3 (range, 101.3 139.8 cm 3 ), (86.0 ± 31.4) cm 3 (range, 49.6 159.1 cm 3 ), (171.9 ± 86.9) cm 3 (range, 103.4 349.6 cm 3 ), (379.7 ± 71.2) cm 3 (range, 257.6 515.8 cm 3 ), and (6.4 ± 2.6) cm 3 (range, 3.9 13.4 cm 3 ), respectively. Doses to the PTV In comparison to the p-sa technique, the f-sa technique produced a higher minimum dose to the PTV, with a D avg of 0.7%, Table 2. Comparison of dosimetric parameters for the f-sa and p-sa plans in RapidArc planning for prostate cancer treatment Structure Parameter f-sa p-sa P PTV Min dose (Gy) 73.5 ± 1.0 72.9 ± 1.0 0.131 Mean dose (Gy) 80.9 ± 0.6 81.0 ± 0.3 0.791 Max dose (Gy) 83.9 ± 0.6 84.4 ± 0.7 09 CI 1.27 ± 5 1.26 ± 4 0.557 HI 1.04 ± 1 1.04 ± 1 0.699 Rectum Mean dose (Gy) 42.3 ± 7.4 38.1 ± 6.2 <01 V 70Gy (%) 21.4 ± 8.3 18.7 ± 4.0 0.135 V 50Gy (%) 48.3 ± 9.8 38.1 ± 7.7 <01 V 40Gy (%) 57.8 ± 10.4 48.1 ± 9.8 <01 V 20Gy (%) 67.6 ± 12.3 63.5 ± 11.9 02 Bladder Mean dose (Gy) 36.7 ± 11.3 30.3 ± 8.8 <01 V 70Gy (%) 14.4 ± 7.7 12.7 ± 6.3 30 V 50Gy (%) 31.4 ± 15.0 23.1 ± 10.1 04 V 40Gy (%) 44.0 ± 18.1 30.6 ± 11.8 01 V 20Gy (%) 67.2 ± 22.1 54.5 ± 17.6 <01 Femoral heads Mean dose (Gy) 13.7 ± 3.0 18.0 ± 3.4 01 Penile bulb Mean dose (Gy) 22.7 ± 6.5 22.1 ± 5.8 0.166 Monitor unit (MUs) 475 ± 28 516 ± 35 28 Integral dose [(cm 3 Gy) 10 6 ] 1.1 ± 0.2 1.2 ± 0.2 <01 Min, minimum; Max, maximum; CI, conformity index; HI, homogeneity index; V ngy, percentage volume irradiated by n Gy or more of a certain structure. The values are presented as mean ± standard deviation (SD) of the 10 analyzed cases. The P values were obtained from paired two-sided Student t tests; a P value < 5 was considered significant. Chin J Cancer; 2013; Vol. 32 Issue 10 549

A 4.0 3.0 2.0 1.0-1.0-2.0-3.0 Min dose Mean dose Max dose CI HI B 3 25.0 2 15.0 1 5.0-5.0-1 D 2 1-1 -2-3 -4-5 -6-7 8 V 70 Gy V 50 Gy V 40 Gy V 20 Gy Mean dose C 4 35.0 3 25.0 2 15.0 1 5.0 V 70 Gy V 50 Gy V 40 Gy V 20 Gy Mean dose Mean FH dose Mean PB dose Integral dose Monitor units Figure 2. Average difference (D avg ) of dosimetric parameters between the f-sa and p-sa plans. A, the dose to the PTV, conformity index (CI), and homogeneity index (HI); B, the dose to the rectum; C, the dose to the bladder; and D, the doses to the femoral heads (FH) and penile bulb (PB), the integral dose, and monitor units. The error bars represent the standard deviations. The values are averaged over the 10 analyzed cases. The is defined in equation 3 (Methods and Materials). V ngy, percentage volume irradiated by n Gy or more of a certain structure. but lower mean and maximum doses to the PTV, with D avg of 0.1% and 0.7%, respectively. Statistical significance was obtained for the maximum dose to the PTV (P = 09) but not for the minimum (P = 0.131) and mean doses to the PTV (P = 0.791). Dose coverage and homogeneity of the PTV The CI was slightly higher in the f-sa plans, indicating that the f-sa technique has the potential to produce less conformal plans than the p-sa technique; however, the D avg was only 0.5% (P = 0.557). Both techniques produced an identical average HI value (1.04), and the D avg was very small (D avg = -0.1%, P = 0.699). Doses to OARs and MU difference The dose to the rectum was always higher in the f-sa plans than in the p-sa plans. Specifically, the f-sa technique produced higher values of V 70Gy (D avg = 8.6%, P = 0.135), V 50Gy (D avg. = 21.2%, P < 01), V 40Gy (D avg = 16.9%, P< 01), and V 20Gy (D avg = 6.1%, P = 02), and mean dose (D avg = 9.7%, P < 01). Similar to dosimetric results of the rectum, the f-sa technique resulted in higher radiation exposure to the bladder, and the p-sa technique was better in sparing of the bladder, showing statistical significance at high, medium, and low dose levels. Specifically, the f-sa technique produced higher values of V 70Gy (D avg = 10.3%, P = 30), V 50Gy (D avg = 25.0%, P = 04), V 40Gy (D avg = 29.5%, P = 01), V 20Gy (D avg = 18.8%, P < 01), and mean dose (D avg = 17.0%, P < 01). In comparison to the f-sa plans, the dose to the femoral heads was significantly higher in the p-sa plans (D avg = 34.4%, P = 01). A cumulative DVH for case # 8 is presented in Figure 3, which clearly shows reduced doses to the bladder and rectum but an increased dose to the femoral heads from the p-sa technique compared with the f-sa technique for the same PTV coverage. The p-sa technique also resulted in a greater number of MUs (D avg = 9.2%, P = 28) and a higher integral dose (D avg = 7.7%, P < 01). In contrast, the mean dose to the penile bulb was lower in the p-sa plans than in the f-sa plan (D avg = 2.2%, P = 0.166). Discussion In this study, we investigated the dosimetric quality of two treatment techniques (f-sa vs. p-sa) in RapidArc planning for the same PTV coverage and identical plan optimization parameters. The dosimetric analysis was performed for the PTV, rectum, bladder, femoral heads, and penile bulb from the DVHs generated in the Eclipse TPS. The dosimetric results obtained from both techniques were within the tolerance limits. The f-sa and p-sa plans had a D avg of ± 1% for the doses to the PTV, and there were no clear differences in dose homogeneity and plan conformity, as indicated by a small D avg (within ± 0.5%). However, in comparison with the f-sa technique, 550 Chin J Cancer; 2013; Vol. 32 Issue 10 Chinese Journal of Cancer

100 Ratio of total structure volume (%) 80 60 40 20 0 Femoral heads Femoral heads 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 Dose (cgy) Figure 3. Dose-volume histogram of case # 8 for organs at risk, such as the rectum, bladder, and femoral heads, and the PTV created by the f-sa and p-sa techniques in RapidArc planning for prostate cancer treatment. the p-sa technique was better in sparing of the rectum and bladder at high, medium, and low dose levels in this study. This was mainly due to the use of anterior and posterior avoidance sectors to prevent the direct beam entrance to certain parts of the bladder and rectum, respectively, thus resulting into lower doses to the bladder and rectum. The D avg for the rectum ranged from 6.1% to 21.2%, whereas the D avg for the bladder ranged from 10.3% to 29.5%. For both the rectum and bladder, a greater difference between f-sa and p-sa plans was observed at the medium dose levels of V 40Gy and V 50Gy (D avg : 16.9% to 29.5%) when compared with the high dose level at V 70Gy (D avg : 8.6% to 10.3%) and low dose level at V 20Gy (D avg : 6.1% to 18.8%). In contrast to the dosimetric results for the rectum and bladder, the femoral heads in the p-sa plans received a higher mean dose mainly due to the spread of lateral dose distributions by the anterior and posterior avoidance sectors used in the p-sa technique. Although we could not find data in the literature that were suitable for direct comparison against our dosimetric data for the f-sa and p-sa techniques in RapidArc planning, it is relevant to mention studies performed by other researchers on RapidArc planning for prostate cancer treatment. Yoo et al. [8] have investigated the dosimetric impact of SA and DA techniques on prostate cancer involving seminal vesicles and lymph nodes. They reported that the DA technique produced a lower maximum dose to the PTV as well as lower doses to the rectum and bladder compared with the SA technique [8]. In contrast, Sze et al. [9] have shown that the SA technique produced a lower dose at a high dose level (V 70Gy ) as well as at a low dose level (V 20Gy ) but a higher dose at a medium dose level (V 40Gy ) for the bladder when compared with the DA technique. Furthermore, Sze et al. [9] have found that the DA technique produced lower doses to the rectum compared to the SA technique. In contrast, Guckenberger et al. [10] have shown that the DA technique yielded a higher dose to the rectum compared with the SA technique, whereas Wolff et al. [11] have found no significant difference in plan quality between the DA and SA plans. Despite the inconsistencies observed among the results of previous studies [8-11], a common finding was that SA achieved better treatment efficiency with dosimetric outcome within tolerable limits. The dosimetric results of the p-sa technique found in this study suggest that the p-sa could provide an alternative option for clinics that currently use the f-sa technique in RapidArc planning for prostate cancer treatment. The p-sa technique showed the possibility of reducing radiation exposure to the rectum, bladder, and penile bulb without compromising the plan conformity and target homogeneity; however, a higher dose to the femoral head and higher values of MUs and integral dose from p-sa technique should also be noted. Furthermore, the dosimetric results presented in this study showed that both the f-sa and p-sa techniques can meet the Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) criteria [12]. Although the p-sa technique showed the possibility of dose escalation for prostate cancer patients by reducing the doses to the rectum and bladder, clinical data, such as normal tissue toxicities, associated with different VMAT planning techniques remain to be reported. One limitation of this study was that we used the same plan optimization parameters (Table 1), which were based on the experience of a single treatment planner. During the plan optimization process in Eclipse TPS, a treatment planner has the flexibility of adjusting the plan optimization parameters to generate an optimum treatment plan. For example, this study showed that the p-sa plans provided a slightly higher dose to the femoral heads, but the stricter dose constraints placed on the femoral heads can force the TPS to reduce the dose to the femoral heads, decrease dose homogeneity across the PTV, and reduce target coverage. Thus, a different set of plan optimization parameters may produce slightly different dosimetric results. We also did not investigate the dosimetric quality of the DA technique. A DA plan generally has more control points and could provide a higher degree of modulation, which may result in better plan quality. In the future, we aim to perform a dosimetric and Chin J Cancer; 2013; Vol. 32 Issue 10 551

radiobiological modeling study to compare f-sa and p-sa techniques with DA techniques. Several researchers have documented the inadequacy of AAA to calculate the dose accurately when inhomogeneous media are involved along the photon beam path [13-17]. Because the same algorithm was used for all dose calculations in this study, the limitation of AAA in dealing with inhomogeneities did not influence the dosimetric comparison between the f-sa and p-sa plans; however, the use of a more accurate dose calculation algorithm, such as Acuros XB (available in the Eclipse TPS), could further improve the dose calculation accuracy of the dosimetric results [15-17]. References [1] Howlader N, Noone AM, Krapcho M, et al. SEER cancer statistics Review. National Cancer Institute, Bethesda, MD, 2009. [2] Ling CC, Zhang P, Archambault Y, et al. Commissioning and quality assurance of RapidArc radiotherapy delivery system. Int J Radiat Oncol Biol Phys, 2008,72:575-581. [3] Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys, 2008, 35: 310-317. [4] Rana SB. Volumetric intensity modulated arc therapy in lung cancer: current literature review. Clin Cancer Investig J, 2013, 2:9-13 [5] Zhang P, Happersett L, Hunt M, et al. Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases. Int J Radiat Oncol Biol Phys, 2010, 76:1456-1462. [6] Palma D, Vollans E, James K, et al. Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys, 2008, 72:996-1001. [7] Shaffer R, Morris WJ, Moiseenko V, et al. Volumetric modulated Arc therapy and conventional intensity-modulated radiotherapy for simultaneous maximal intra prostatic boost: a planning comparison study. Clin Oncol (R Coll Radiol), 2009, 21:401-407. [8] Yoo S, Wu QJ, Lee WR, et al. Radiotherapy treatment plans with RapidArc for prostate cancer involving seminal vesicles and lymph nodes. Int J Radiat Oncol Biol Phys, 2010, 76:935-942. [9] Sze HC, Lee MC, Hung WM, et al. RapidArc radiotherapy planning for prostate cancer: single-arc and double-arc techniques vs. intensity-modulated radiotherapy. Med Dosim, 2012, 37:87-91. [10] Guckenberger M, Richter A, Krieger T, et al. Is a single arc Conclusions The preliminary results presented in this study showed that it is feasible to use the p-sa technique in RapidArc planning for prostate cancer treatment. For the same PTV coverage and identical plan optimization parameters, the p-sa technique delivers a higher dose to the femoral heads but reduces the doses to the rectum, bladder, and penile bulb without compromising the plan conformity and target homogeneity when compared with the f-sa technique. Received: 2013-04-24; revised: 2013-06-13; accepted: 2013-06-13. sufficient in volumetric-modulated arc therapy (VMAT) for complexshaped target volumes? Radiother Oncol, 2009, 93: 259-265. [11] Wolff D, Stieler F, Welzel G, et al. Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. Radiother Oncol, 2009, 93:226-233. [12] Marks LB, Yorke ED, Jackson A, et al. Use of normal tissue complication probability models in the clinic. Int J Radiat Oncol Biol Phys, 2010, 76(3 Suppl):S10-9. [13] Robinson D. Inhomogeneity correction and the analytic anisotropic algorithm. J Appl Clin Med Phys, 2008; 9: 112-122. [14] Rana SB. Dose prediction accuracy of anisotropic analytical algorithm and pencil beam convolution algorithm beyond high density heterogeneity interface. South Asian J Cancer, 2013, 2:26-30. [15] Bush K, Gagne IM, Zavgorodni S, et al. Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations. Med Phys, 2011, 38:2208-2221. [16] Rana S, Rogers K. Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes. J Med Phys, 2013, 38:9-14. [17] Han T, Mourtada F, Kisling K, et al. Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom. Med Phys, 2012, 39:2193-2202. 552 Chin J Cancer; 2013; Vol. 32 Issue 10 Chinese Journal of Cancer