Venous stenosis or occlusion is a frequent finding

Similar documents
Accepted Manuscript. S (19) Reference: HRCR 678. To appear in: HeartRhythm Case Reports

Subcutaneous ICD Emerging Role of Sudden Cardiac Death Prevention

INNOVATIONS IN DEVICE THERAPY:

Girish M Nair, Seeger Shen, Pablo B Nery, Calum J Redpath, David H Birnie

What You Should Know About Subcutaneous and Transvenous ICD

EBR Systems, Inc. 686 W. Maude Ave., Suite 102 Sunnyvale, CA USA

SUBCUTANEOUS IMPLANTABLE CARDIOVERTER DEFIBRILLATORS

file://c:\documents and Settings\admin\My Documents\CV\92.htm

Patients with hypertrophic cardiomyopathy (HCM) are at

This is What I do to Improve CRT Response for CRT Non-Responders

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

GDT1000 SENSING ACUTE STUDY

Cardiac Devices CRT,ICD: Who is and is not a Candidate? Who Decides

1546 SASAKI S et al. Circ J 2018; 82: ORIGINAL ARTICLE doi: /circj.CJ Primary Japanese Experience

A Square Peg in a Round Hole: CRT IN PAEDIATRICS AND CONGENITAL HEART DISEASE

Implantation of a biventricular implantable cardioverter-defibrillator guided by an electroanatomic mapping system

Response of Right Ventricular Size to Treatment with Cardiac Resynchronization Therapy and the Risk of Ventricular Tachyarrhythmias in MADIT-CRT

Selecting the Best ICD for your Patient-SICD v. TV. Martin C. Burke DO, FACOI CorVita Science Foundation & Academic Medical Center, Amsterdam

Supplemental Material

POLICIES AND PROCEDURE MANUAL

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

Oversensing of atrial fibrillatory waves in a subcutaneous implantable cardioverter-defibrillator

The subcutaneous implantable cardioverter defibrillator review of the recent data

Pediatric pacemakers & ICDs:

Dialysis-Dependent Cardiomyopathy Patients Demonstrate Poor Survival Despite Reverse Remodeling With Cardiac Resynchronization Therapy

A Prospective Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations: The PropR Study

Early Experience with the Subcutaneous ICD

Anodal Capture in Cardiac Resynchronization Therapy Implications for Device Programming

New generations pacemakers and ICDs: an update

2010 Canadian Cardiovascular Society/ Canadian Heart Rhythm Society Training and Maintenance of Competency in Adult Clinical Cardiac

12 Lead ECG Skills: Building Confidence for Clinical Practice. Presented By: Cynthia Webner, BSN, RN, CCRN-CMC. Karen Marzlin, BSN, RN,CCRN-CMC

How to Approach the Patient with CRT and Recurrent Heart Failure

TWIDDLER S syndrome is characterized by coiling of the pacemaker lead due

ECG. Prepared by: Dr.Fatima Daoud Reference: Guyton and Hall Textbook of Medical Physiology,12 th edition Chapters: 11,12,13

Subcutaneous Implantable Cardioverter Defibrillator (S-ICD)

INTRODUCTION TO ECG. Dr. Tamara Alqudah

MEDICAL POLICY POLICY TITLE T-WAVE ALTERNANS TESTING POLICY NUMBER MP

Electrocardiographic Eligibility for Subcutaneous Implantable Cardioverter Defibrillator: Evaluation during Bicycle Exercise

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Pacing in patients with congenital heart disease: part 1

Successful treatment of tachycardia-induced cardiomyopathy secondary to dual atrioventricular nodal nonreentrant tachycardia using cryoablation

Need to Know: Implantable Devices. Carolyn Brown RN, MN, CCRN Education Coordinator Emory Healthcare Atlanta, Georgia

Relax and Learn At the Farm 2012

Cardiac implantable electronic devices (CIEDs) in children include pacemakers and implantable cardioverter defibrillators (ICDs).

The EFFORTLESS SICD Registry. The EFFORTLESS SICD Registry. SICD Implant 11/14/2016

Introduction to Electrocardiography

Map-Guided Ablation of Non-ischemic VT. Takashi Nitta Cardiovascular Surgery, Nippon Medical School Tokyo, JAPAN

How do I convert my CRT Non Responder into Responder?

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

12 Lead ECG Interpretation

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

The Role of Ventricular Electrical Delay to Predict Left Ventricular Remodeling With Cardiac Resynchronization Therapy

MEDICAL POLICY SUBJECT: IMPLANTABLE CARDIOVERTER DEFIBRILLATOR

ECG INTERPRETATION MANUAL

James H. Baker II, MD St. Thomas Heart Nashville, TN

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

12 LEAD EKG BASICS. By: Steven Jones, NREMT P CLEMC

Ablative Therapy for Ventricular Tachycardia

HISTORY. Question: What category of heart disease is suggested by this history? CHIEF COMPLAINT: Heart murmur present since early infancy.

Implantable cardioverter defibrillator, Inappropriate shock, Lead failure

Update on Device Innovation (S-ICD, Wearable, Leadless)

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

1328 OKAMURA H et al.

Clinical Cardiac Electrophysiology

Qu attendre de la technologie pour un meilleur suivi? (traitement) D Gras, MD, Nantes, France

Is This Thing Working?

Sudden Cardiac Death What an electrophysiologist thinks a cardiologist should know

Exercise stress test reveals ineligibility for subcutaneous implantable cardioverter

2992 YOSHITAKE T et al. Circ J 2018; 82: ORIGINAL ARTICLE doi: /circj.CJ

Upgrade to Resynchronization Therapy. Saeed Oraii MD, Cardiologist Interventional Electrophysiologist Tehran Arrhythmia Clinic May 2016

Pacemaker System Malfunction Resulting from External Electrical Cardioversion: A Case Report

PVCs: Do they cause Cardiomyopathy? Raed Abu Sham a, M.D.

Comparison of clinical trials evaluating cardiac resynchronization therapy in mild to moderate heart failure

Summary, conclusions and future perspectives

Electrocardiogram ECG. Hilal Al Saffar FRCP FACC College of medicine,baghdad University

Cardiac Rhythm Management Coder 2018

BASIC CONCEPT OF ECG

Valie-Asr Avenue,Adj to mellat Tehran , Iran.

Cardiovascular Implantable Electronic Device Leads & Arteriovenous Hemodialysis Access

NOVEL DEVICE TECHNOLOGIES

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Declaration of conflict of interest

How to treat Cardiac Resynchronization Therapy complications? C. Leclercq Departement of Cardiology Centre Cardio-Pneumologique Rennes, France

Subcutaneous implantable cardioverter-defibrillator (S-ICD)

Cardiac Resynchronization ICD Therapy: What is New?

Thelearningcurveassociatedwiththe introduction of the subcutaneous implantable defibrillator

Recent Advances in Pacing and Defibrillation Harish Doppalapudi, MD

DECLARATION OF CONFLICT OF INTEREST. None to declare

Advances in Ablation Therapy for Ventricular Tachycardia

The Electrocardiogram part II. Dr. Adelina Vlad, MD PhD

Shock Reduction Strategies Michael Geist E. Wolfson MC

Defibrillation threshold testing should no longer be performed: contra

Tachycardia Devices Indications and Basic Trouble Shooting

20 ng/ml 200 ng/ml 1000 ng/ml chronic kidney disease CKD Brugada 5 Brugada Brugada 1

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

REtrive. REpeat. RElearn Design by. Test-Enhanced Learning based ECG practice E-book

CLINICAL CARDIAC ELECTROPHYSIOLOGY Maintenance of Certification (MOC) Examination Blueprint

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

THE CARDIOVASCULAR SYSTEM

Transcription:

CLINICAL STUDY Candidacy for a Subcutaneous Implantable Cardioverter Defibrillator in Patients with Cardiac Resynchronization Therapy Surface Electrocardiogram Screening on the Assumption of the Concomitant Use of the Subcutaneous Implantable Cardioverter Defibrillator and Biventricular Pacing Mihoko Kawabata, 1 MD, Masahiko Goya, 1 MD, Yoshihide Takahashi, 1 MD, Shingo Maeda, 1 MD, Atsuhiko Yagishita, 1 MD, Yasuhiro Shirai, 1 MD, Masakazu Kaneko, 1 MD, Shinya Shiohira, 1 MD and Kenzo Hirao, 1 MD Summary In patients requiring an implantable cardioverter defibrillator (ICD), the combined use of a prior pacemaker and a subcutaneous ICD (S-ICD) could be an alternative treatment option to implantation of new leads or upgrading of pacemakers to an ICD if vascular access is limited. Here, we assessed the prevalence of S-ICD s eligibility according to surface electrogram screening in those receiving cardiac resynchronization therapy (CRT). S-ICD s eligibility was assessed in patients with a CRT pacemaker or a CRT defibrillator using the S-ICD template screening tool. Eligibility was defined as fulfillment of the template in both supine and upright positions in one or more leads during biventricular pacing. Among 44 patients (34 men, age: 67 ± 12), 36 (82%) were found to be eligible. The T/QRS amplitude ratio in lead II was significantly lower in those who were eligible (0.31 ± 0.16 versus 0.44 ± 0.18 in the ineligible group, P = 0.04). The lead position, underlying disease, and other electrocardiographic findings were not different between those who were eligible and those who were not. The majority of patients with biventricular pacing were eligible for S-ICD based on current screening tests and may benefit from this treatment. Further study is required. (Int Heart J Advance Publication) Key words: Cardiac implantable electronic devices, Combining therapy, Electrocardiographic screening tool, Venous stenosis or occlusion, Previously-implanted transvenous leads, Chronic heart failure Venous stenosis or occlusion is a frequent finding in patients with previously implanted transvenous leads, 1-3) making it difficult to implant new leads. Physicians may resort to implanting epicardial leads if venous access is unavailable. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a recent development, but they are already widely used. Their effectiveness and safety have been shown in large registries. 4,5) S-ICD implantation is less invasive than that of conventional ICDs and is particularly useful for patients with congenitally complex cardiac anatomy or those without venous access. 6) One disadvantage, though, is that S-ICDs cannot provide pacing therapy lacking transvenous leads. There have been several case reports of patients with previous transvenous or epicardial pacemakers, in whom S-ICD was newly implanted and used together, 7-13) as well as of prior cardiac resynchronization therapy (CRT) with an S-ICD. 7,14) In clinical settings, the number of such patients whose venous access cannot be secured, resulting in no choice other than the concomitant use of pacemakers and S-ICDs, might increase in the future. The purpose of our study was to go beyond case reporting and assess the proportion of current CRT recipients who are eligible for S-ICD implantation in a moderate-sized patient population. We used surface electrocardiogram (ECG) screening tests to test for S-ICD eligibility as is the current standard. Methods Study population: We assessed consecutive patients that had previously received CRT pacemakers (CRT-Ps) or CRT defibrillators (CRT-Ds), who attended routine followup at the pacemaker/icd device clinic in our hospital between February 2016 and March 2017. Demographic data, clinical characteristics, medications, and ultrasound characteristics were obtained from clinical records. ECG parameters were collected from the most recent 12-lead surface ECG. The study complied with the Declaration of Helsinki. The use of routinely collected anonymous data was ap- From the 1 Heart Rhythm Center, Tokyo Medical and Dental University, Tokyo, Japan. This work was supported by a program for women researchers from the Tokyo Medical and Dental University, Japan, through 2015 and 2017. Address for correspondence: Mihoko Kawabata, MD, Heart Rhythm Center, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan. E-mail: mihoko_kawabata.cvm@tmd.ac.jp Received for publication September 24, 2017. Revised and accepted November 28, 2017. Released in advance online on J-STAGE August 11, 2018. doi: 10.1536/ihj.17-550 All rights reserved by the International Heart Journal Association. 1

2 Kawabata, ET AL IntHeartJ Advance Publication Figure 1. Surface electrocardiogram lead positions during screening for S-ICDs. 15) This figure shows the location of the surface electrodes and S-ICD sensing vectors in the conventional left parasternal and right parasternal configuration. Left-sided parasternal position. LL: in the fifth intercostal space along the left midaxillary line, LA: 1 cm lateral to the left sternal border and 1 cm above the xiphoid process, and RA: 14 cm cranial to electrode LA on the left parasternal line. Electrodes RA and LA on the right-sided parasternal position. LA: 1 cm lateral to the right sternal border and 1 cm above the xiphoid process, RA: 14 cm superior to electrode LA. A ground electrode was placed on a soft tissue location on the right lower extremity. RA indicates right arm; LA, left arm; LL, left leg; and G, ground. proved by the local ethics committee and was deemed not to require formal patient consent. Screening for S-ICD eligibility: The Boston Scientific ECG screening tool was used to determine the eligibility for S-ICD in 2 different postures, supine, and upright, during biventricular pacing. As recommended by Boston Scientific, ECG recordings simulating the 3 sensing vectors of the S-ICD were analyzed. 15) The left leg (LL) electrode was placed in the fifth intercostal space along the left midaxillary line, the left arm (LA), 1 cm lateral to the left sternal border and 1 cm above the xiphoid process, and the right arm (RA), 14 cm cranial to the LA electrode (Figure 1). A ground electrode was placed on a soft tissue location on the right lower extremity. The bipolar vector lead I was derived from RA and LA, lead II from RA and LL, and lead III from LA and LL, corresponding to the alternate, secondary, and primary sensing vectors of the S- ICD, respectively. A patient was considered a candidate for S-ICD implant if at least one lead satisfied the S-ICD screening template in both supine and upright positions. The screening protocol was repeated after moving the sternal electrodes (electrodes RA and LA) to the right parasternal line, with electrode LA at 1 cm lateral to the right sternal border and 1 cm above the xiphoid process and electrode RA at 14 cm superior to electrode LA, if the screening failed with the sternal electrodes placed along the left parasternum. Surface 12-lead ECG analysis: We measured the QRS and the T-wave axes in the patient s most recent 12-lead surface ECG. The angle between the 2 axes was evaluated as the absolute value of the minor angle. Leads I, II, and avf were analyzed because these leads mimic the 3 sensing vectors of the S-ICD. The T/QRS amplitude ratio in each of the 3 leads was collected. All ECGs were analyzed by 2 independent electrophysiologists. Reasons for failure were recorded for every single analyzed vector and categorized into high T-wave voltage, high/low QRS complex voltage, and wide QRS complex. The lead positions of CRT: The position of the RV lead, apex, or septum, was assessed using the procedure record and the patient s most recent chest X-ray. The position of the LV lead was categorized using chest X-rays. In the posteroanterior view (Figure 2A), the semielliptic shape outlined by the cardiac silhouette was divided into 3 parts along the major axis: the base, the middle, and the apex. In the lateral view (Figure 2B), the semicircle whose straight edge was in the head-tail direction of the body and whose arc was outlined by the posterior cardiac silhouette was divided into 3 pie-shaped parts at intervals of 60 : anterior, lateral, and posterior. The position of the LV lead tip was expressed combining the bidirectional assessments (anterior base, lateral base, etc.) (Figure 2C). Statistical analysis: Normally distributed continuous variables were expressed as the mean ± standard deviation, and as numbers, and percentages for categorical variables. The differences between the continuous variables were assessed using Student s t-test. Categorical variables were compared using the χ 2 test, or Fisher s exact test when the data are very unequally distributed among the cells of the Table resulting in the expected values in any of the cells of the contingency table being below 5. A multivariable logistic regression analysis was performed to identify the independent clinical predictors of S-ICD s ineligibility. Statistical significance was defined as P < 0.05. SPSS statistical software (v22, SPSS Inc., Chicago, IL, USA) was used for all statistical analyses. Results Study population: A total of 44 consecutive patients (34 men, age: 67 ± 12) were included, comprising 19 patients with dilated cardiomyopathy (DCM), 8 patients with ischemic heart disease, 6 patients with sarcoidosis, 6 patients with valve disease, 2 patients with hypertrophic cardiomyopathy (HCM), and 3 miscellaneous cases. There were 34 patients (77%) with CRT-Ds, whose indication for ICD implantation was primary prevention in 82% and secondary prevention in 18% of the patients. The RV lead was positioned at the apex in 38 patients and along the septum in 6. The LV lead was positioned in the antero-base in 4 patients, in the antero-mid in 6, in the antero-apex in 1, in the lateral base in 4, in the lateral mid in 10, in the lateral apex in 8, in the postero-mid in 5, and in the postero-apex in 6 (Figure 2 C). Patients characteristics are summarized in the Table. Prevalence of S-ICD s unsuitability: Overall, a total of 8 (18%) patients were ineligible for S-ICD implantation according to the surface ECG screening criteria during CRT. The 8 patients were distributed over all 6 underlying disease categories (Figure 3), and there was no statistically significant difference in the distribution (P = 0.39). Among a total of 264 sensing vectors (44 patients 3 vectors 2 positions), 108 (41%) were considered ineli-

IntHeartJ Advance Publication CONCOMITANT USE OF S-ICDs AND CRT 3 Figure 2. The position of the LV lead. A: In the posteroanterior view of chest X-rays, the semielliptic shape outlined by the cardiac silhouette (indicated by the blue line) was divided into 3 parts along the major axis: the base, the middle, and the apex. The red arrow shows the tip of the LV lead. B: In the lateral view of chest X-rays, the semicircle whose straight edge was in the head-tail direction of the body and whose arc was outlined by the posterior cardiac silhouette (indicated by the blue line) was divided into 3 pie-shaped parts at intervals of 60 : anterior, lateral, and posterior. The red arrow shows the tip of the LV lead. C: The position of the LV lead was divided into 9 parts by the combination of the bidirectional assessments with the number of patients in each position. gible by the screening test. The secondary sensing vector was the most frequently ineligible one (49%), followed by the alternate vector (39%) and the primary sensing vector (35%). The main reason for failure was the high T-wave voltage (76% of sensing vectors), followed by the wide QRS complex (13%), low QRS complex voltage (5.5%), and high QRS complex voltage (5.5%). Figure 4 shows an example of a record that was ineligible because of a wide QRS complex in 2 vectors using the left parasternal placement of sternal electrodes. In 5 out of the 8 patients who were ineligible for S- ICD implantation, the screening test was performed again after switching electrode placement from the conventional left parasternal position to the right parasternum. However, ECG eligibility did not improve in any patient. Predictors of eligibility in patients with CRT: The clinical characteristics of the patients who were eligible and ineligible in the left parasternal electrode placement screening were compared (Table). The T/QRS amplitude ratio in lead II was significantly higher in those who were ineligible than in those who were eligible. There was a tendency for a higher T/QRS amplitude ratio in lead avf and more septal RV lead in the ineligible group, although it did not reach statistical significance. Other baseline characteristics were similar between the groups. In multivariate analysis assessing the T/QRS amplitude ratio in

4 Kawabata, ET AL IntHeartJ Advance Publication Table. Patients Characteristics. Total (n = 44) Eligible (n = 36) Ineligible (n = 8) P value Age (years) 67 ± 11 66 ± 12 70 ± 10 0.45 Male 34 (77%) 27 (75%) 7 (88%) 0.66 Height (m) 1.63 ± 0.10 1.63 ± 0.10 1.63 ± 0.11 1.0 Weight (kg) 60 ± 13 59 ± 13 65 ± 14 0.30 BMI (kg/m 2 ) 22.5 ± 4.1 22.1 ± 4.0 24.3 ± 4.6 0.16 CRT-P/CRT-D 9/35 5/31 4/4 0.04 Primary/secondary prevention 28/7 25/6 3/1 0.60 Hypertension 14 (32%) 10 (28%) 4 (50%) 0.21 Ischemic heart disease 8 (18%) 7 (19%) 1 (13%) 0.55 Medication Beta-blockers 38 (86%) 32 (89%) 6 (75%) 0.30 Antiarrhythmic drugs 32 (73%) 26 (72%) 6 (75%) 0.63 12-lead ECG QRS width (ms) 157 ± 18 158 ± 15 154 ± 27 0.57 QTc interval 501 ± 28 500 ± 29 506 ± 26 0.60 QRS axis (degree) -24 ± 101-31 ± 97 7 ± 123 0.35 T-wave axis (degree) 55 ± 57 54 ± 60 63 ± 47 0.69 The angle between QRS and T-axes (degree) 148 ± 43 145 ± 48 160 ± 18 0.15 T/QRS amplitude in lead I 0.32 ± 0.30 0.33 ± 0.32 0.29 ± 0.23 0.70 T/QRS amplitude in lead II 0.33 ± 0.17 0.31 ± 0.16 0.44 ± 0.18 0.04 T/QRS amplitude in lead avf 0.31 ± 0.17 0.29 ± 0.15 0.42 ± 0.23 0.056 UCG LVEF (%) 33 ± 11 33 ± 12 36 ± 12 0.46 LVDd (mm) 65 ± 10 66 ± 10 63 ± 10 0.43 Xp CTR (%) 54 ± 7 53 ± 7 54 ± 4 0.74 Lead position RV lead (apex/septum, n) 38/6 33/3 5/3 0.06 LV lead in PA view (base/mid/apex, n) 8/21/15 7/16/13 1/5/2 0.65 LV lead in lateral view (ant/lat/post, n) 11/22/11 10/17/9 1/5/2 0.63 LV lead (A-b/A-m/A-a/L-b/L-m/L-a/P-b/P-m/P-a, n) 4/4/0/6/10/5/1/8/6 4/3/0/5/7/4/1/7/5 0/1/0/1/3/1/0/1/1 0.94 Values are shown as the mean ± SD, or n (%). A- indicates antero; -a, apex; -b, base; BMI, body mass index; CRT-P/-D, cardiac resynchronization therapy-pacemaker/defibrillator; CTR, cardiothoracic ratio; ECG, electrocardiogram; L-, latero; LV, left ventricle; LVDd, left ventricular internal dimension in diastole; LVEF, left ventricular ejection fraction; -m, mid; P-, postero; PA, posteroanterior; QTc, corrected QT; RV, right ventricle; UCG, ultrasound cardiography; and Xp, X-ray photograph. leads II and avf and septal RV lead, no variables remained as independent predictors. In a 69-year-old woman with cardiac sarcoidosis (Amplia MRI Quad CRT-D with AdaptivCRT Algorithm, Medtronic Inc., Minneapolis, MN, USA), the ECG screening satisfied S-ICD s eligibility during the RBBB pattern (QRS width 130 ms in 12-lead ECG), but not during the LBBB pattern (QRS width 161 ms) (Figure 5). There were 3 patients in whom pacemakers or ICDs with RV leads had been upgraded to CRT-Ps or CRT-Ds. When screening was compared between RV and biventricular pacing, the results were varied: one was eligible in both modes; in another, eligible only in RV pacing; and in the third, eligible only in biventricular pacing. Discussion In this study, based on our single-center experience, S-ICD screening failure occurred in 18% of the current CRT recipients during biventricular pacing. The secondary sensing vector was the one most frequently ineligible. Combination therapy with S-ICDs and pacemakers: S- ICDs are usually not indicated in patients who need antibradycardia pacing because no intracardiac leads are placed. On the other hand, they are suited for patients who have limited venous access. It has been reported that venous occlusion is observed in 26-33% of patients with previous transvenous leads of ICDs or pacemakers. 1-3) Prior to our study, there have been some reports of patients with previous transvenous or epicardial pacemakers in whom S-ICD was newly implanted and used together, 7-14) but the clinical experience is still limited. The pooled cohort of the 2 largest S-ICD trials, the Food and Drug Administration-mandated U.S. Investigational Device Exemption (IDE) Registry and the Evaluation of FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD (EFFORTLESS S-ICD) registry, excluded patients with unipolar pacemakers or implanted devices that revert to unipolar pacing and included only 19 individuals who had a bipolar pacemaker prior to S-ICD implantation. However, no further details were given regarding those patients. 16) In the previous case reports, appropriate sensing by the S-ICD was confirmed during ventricular pacing. It was recommended that bipolar and not unipolar pacing should be used to minimize the pacing artifact on the S-ICD electrograms 8) and the detection rate of the S- ICD should be programmed at more than twice the upper pacing rate of the pacemaker. 9) van Gelder, et al. reported

IntHeartJ Advance Publication CONCOMITANT USE OF S-ICDs AND CRT 5 Figure 3. The prevalence of S-ICD according to the underlying diseases. There were no significant differences in the prevalence of S-ICD s unsuitability among the underlying diseases. Figure 4. Example of surface electrocardiographic screening in a patient with DCM. The left ECG shows the 12- lead ECG and the right ECGs show the screening vectors of leads I through III in supine and upright positions. an inappropriate shock due to triple counting caused by a wide-paced QRS complex with double R-wave counting and additional T-wave sensing in a patient with an S-ICD and a pacemaker, which was corrected by implantation of a second CS lead and bifocal pacing. 14) Extensive testing to prevent such adverse events is warranted.

6 Kawabata, ET AL IntHeartJ Advance Publication Figure 5. Example of ECG screening in a patient with cardiac sarcoidosis using Amplia MRI Quad CRT-D with AdaptivCRT Algorithm (Medtronic Inc.). The screening test changed from appropriate (A) to inappropriate (B) along with the change of morphologies of QRS complexes. In both panels, the left ECG shows the 12-lead ECG and the right ECGs show the screening vectors of leads I through III in supine and upright positions.

IntHeartJ Advance Publication CONCOMITANT USE OF S-ICDs AND CRT 7 Surface ECG screening test during pacing therapy compared to that during intrinsic rhythm: Currently, a surface ECG screening test is performed prior to the implantation of S-ICDs to exclude patients who might receive inappropriate shocks. Recently, a high-pass filter was introduced to improve the sensing algorithm. However, the current clinical screening test criteria have not been changed. It is expected that new screening criteria will be introduced in the near future. In this study, we were limited to assessments based on the screening test in current use. The reported prevalence of the ineligibility for S-ICD implantation in patients without pacing therapy ranges from 7 to 16%. An R/T ratio of less than 3 in the lead with the largest T-wave, T-wave inversion, QRS duration, and low BMI were reported as predictors of failed screening for the S-ICD. 15,17-19) Ip, et al. reported that the ineligibility for S-ICD implantation in patients who have existing transvenous pacing devices was 42% during ventricular pacing. They included 25 patients with CRT devices, who were less likely to be ineligible compared to those with RV pacing alone (20% versus 54%, P < 0.01). They also showed that patients that were paced from the RV septum were less likely to be ineligible compared to those paced from the apex (33% versus 63%, P < 0.01). 20) Compared to these reports, our study found an ineligibility of 18% during CRT, which was roughly similar to the rate in those without pacing therapy 15,17-19) and those during CRT. 20) We could not find a significant relation between the lead positions of CRT and the results of the screening test. In the previous studies assessing those without pacing therapy, the least favorable sensing vector was the alternate vector. 15) On the contrary, the secondary sensing vector was the least favorable during biventricular pacing in our study. We also found that the T/R ratio in lead II, whose vector was similar to the secondary sensing vector, was significantly higher in those who failed the screening test. The difference in the vector of depolarization and repolarization between intrinsic beats and biventricular paced beats might cause this discrepancy. However, there were no significant differences in other electrocardiographic data or lead positions between those that were eligible and those that were ineligible during CRT. Right parasternal electrode positioning was previously reported to improve the eligibility for S-ICD in patients without pacing therapy. 15) This was not the case in our study. There were no patients in whom right parasternal screening test improved eligibility, although 3 out of 8 were not retested in the right parasternum. T-wave oversensing accounts for the majority of inappropriate shocks in the S-ICD system, ranging from 39 to 73% of all inappropriate shocks. 16,21) In our study, during CRT, the main reason for failure was also the high T- wave voltage, although the wide QRS complex also caused ineligibility in 13% of sensing vectors. In this study, we had a few cases in which ECG screening was conducted during both RV and biventricular pacing, or during both RBBB and LBBB pattern QRS complexes, showing varying results. Ip, et al. reported that 12 patients who were screened during biventricular pacing were not screened during RV pacing. 20) Although we did not screen ECG in multiple pacing modes of CRT in other patients, it is possible that an adjustment in the pacing mode for each patient would increase the number of patients who are eligible, allowing the combination of CRT and S-ICD. In the AdaptivCRT Algorithm, which chooses the most proper pacing mode automatically, the morphologies in all pacing modes should be evaluated during preoperative screening. If there are pacing modes that are ineligible, devices need to be programmed not to switch the pacing mode automatically. For patients who require the 2 devices, adjusting both to prevent exacerbation of heart failure and inappropriate shock delivery is essential. Further study is needed. Limitations: Our study has several limitations. The major limitation is the small sample size. The underlying heart diseases were also limited, including no congenital heart disease. 22) The external validity of our study is limited to the patient population that we studied. Any assessment of eligibility for S-ICD is affected by the population under consideration. The values of subgroup analysis based on the etiology or the lead positions were limited because of the small study population. As we discussed above, the sensing algorithm in S- ICD technology has been improving. Newer ECG screening methods may improve the rate of eligibility for S-ICD implantation. When a pacemaker is combined with an S-ICD, the assumption is that both the stimulated and the native heartbeats would be observed, necessitating both morphologies to be evaluated in the ECG screening beforehand. However, we did not assess the native heartbeats in this study because the higher ventricular pacing rate is set as the objective during CRT. We assessed only during the actually used biventricular pacing mode, not during RV pacing. The preimplant screening assumes that vectors suitable at preimplant screening fulfill criteria for the sensing algorithm of the S-ICD when implanted and exclude patients who fail S-ICD candidacy. The defibrillation ability of S-ICD and the interference between the devices were beyond the scope of this study. The lack of data of the real follow-up and the most appropriate device settings is a limitation of this paper, although we believe that our data about the screening test might help in making decisions for this challenging clinical issue. The follow-up and outcome data need further studies in the future. We did not study the eligibility for S-ICD in patients with leadless pacemakers. 23) Conclusion The majority of patients with biventricular pacing were eligible to receive S-ICDs on the basis of currently available screening tests. It may be possible to use an S- ICD together with a CRT-P in such patients, although highly individualized device settings and careful follow-up are necessary. Further study is required.

8 Kawabata, ET AL IntHeartJ Advance Publication Disclosures Conflicts of interest: The authors declare that they have no conflict of interest. Ethical approval: For this type of study formal consent is not required. Acknowledgments We would like to thank Ms. Hiroko Ozaki, for her technical assistance with data collection. References 1. Abu-El-Haija B, Bhave PD, Campbell DN, et al. Venous stenosis after transvenous lead placement: A study of outcomes and risk factors in 212 consecutive patients. J Am Heart Assoc 2015; 4: e001878. 2. Haghjoo M, Nikoo MH, Fazelifar AF, Alizadeh A, Emkanjoo Z, Sadr-Ameli MA. Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade. Europace 2007; 9: 328-32. 3. Oginosawa Y, Abe H, Nakashima Y. The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads. Pacing Clin Electrophysiol 2002; 25: 1605-11. 4. Weiss R, Knight BP, Gold MR, et al. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. Circulation 2013; 128: 944-53. 5. Lambiase PD, Barr C, Theuns DA, et al. EFFORTLESS Investigators. Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S- ICD registry. Eur Heart J 2014; 35: 1657-65. 6. Ishizuka M, Yamamoto Y, Yamada S, et al. Bilateral subclavian vein occlusion in a SAPHO syndrome patient who needed an implantable cardioverter defibrillator. Int Heart J 2016; 57: 380-2. 7. Huang J, Patton KK, Prutkin JM. Concomitant use of the subcutaneous implantable cardioverter defibrillator and a permanent pacemaker. Pacing Clin Electrophysiol 2016; 39: 1240-5. 8. Akin I, Röger S, Borggrefe M, Kuschyk J. Impeding sudden cardiac death despite subcutaneous implantable defibrillator due to fatal crosstalk. J Cardiovasc Electrophysiol 2016; 27: 613-4. 9. Porterfield C, DiMarco JP, Mason PK. Effectiveness of implantation of a subcutaneous implantable cardioverter-defibrillator in a patient with complete heart block and a pacemaker. Am J Cardiol 2015; 115: 276-8. 10. Kuschyk J, Stach K, Tülümen E, et al. Subcutaneous implantable cardioverter-defibrillator: First single-center experience with other cardiac implantable electronic devices. Heart Rhythm 2015; 12: 2230-8. 11. Gemein C, Haj M, Schmitt J. Combining an subcutaneous ICD and a pacemaker with abdominal device location and bipolar epicardial left ventricular lead: First-in-man approach. Europace 2016; 18: 1279. 12. Steinberg C, Chakrabarti S, Krahn AD, Bashir J. Nothing inside the heart - Combining epicardial pacing with the S-ICD. Heart Rhythm Case Rep 2015; 1: 419-23. 13. van Gelder BM, Bracke FA, Simmers T. Inappropriate shock because of triple counting in a patient with a subcutaneous implantable cardioverter defibrillator corrected by initiation of dual site left ventricular pacing. Circ Arrhythm Electrophysiol 2015; 8: 239-40. 14. Erath JW, Sirat AS, Vamos M, Hohnloser SH. Epicardial CRT-Pand S-ICD implantation in a young patient with persistent left superior vena cava. Herzschrittmacherther Elektrophysiol 2016; 27: 396-8. 15. Kawabata M, Goya M, Sasaki T, et al. Surface electrocardiogram screening for subcutaneous implantable cardioverterdefibrillators in Japanese patients with and without Brugada syndrome. Circ J 2017; 81: 981-7. 16. Burke MC, Gold MR, Knight BP, et al. Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE Study and EFFORTLESS Registry. J Am Coll Cardiol 2015; 65: 1605-15. 17. Randles DA, Hawkins NM, Shaw M, Patwala AY, Pettit SJ, Wright DJ. How many patients fulfill the surface electrocardiogram criteria for subcutaneous implantable cardioverterdefibrillator implantation? Europace 2014; 16: 1015-21. 18. Groh CA, Sharma S, Pelchovitz DJ, et al. Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator. Heart Rhythm 2014; 11: 1361-6. 19. Olde Nordkamp LR, Warnaars JL, Kooiman KM, et al. Which patients are not suitable for a subcutaneous ICD: incidence and predictors of failed QRS-T-wave morphology screening. J Cardiovasc Electrophysiol 2014; 25: 494-9. 20. Ip JE, Wu MS, Kennel PJ, et al. Eligibility of pacemaker patients for subcutaneous implantable cardioverter defibrillators. J Cardiovasc Electrophysiol 2017; 8: 544-8. 21. Kooiman KM, Knops RE, Olde Nordkamp L, Wilde AA, de Groot JR. Inappropriate subcutaneous implantable cardioverterdefibrillator shocks due to T-wave oversensing can be prevented: Implications for management. Heart Rhythm 2014; 11: 426-34. 22. Numata G, Amiya E, Kojima T, et al. Cardiac resynchronization therapy in patients with Ebstein s anomaly. Int Heart J 2017; 58: 816-9. 23. Tjong FV, Brouwer TF, Smeding L, et al. Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance. Europace 18: 1740-7.