Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device

Similar documents
Patient. Device Clinician. Safety & efficacy

Concurrent Use Of Metered Dose Inhalers Without Spacer And Dry Powder Inhalers By Asthmatic Children Adversely Affect Proper Inhalation Technique

Beclometasone dipropionate (BDP) Prophylactic management of mild, moderate or severe asthma in adults

Ivax Pharmaceuticals UK Sponsor Submission to the National Institute for Health and Clinical Excellence

Your Inhaler Devices & You

What you need to know about inhalers and how to use them Henry Chrystyn PhD, FRPharmS and David Price MA, MRCGP, DRCOG

An update on inhalation devices

Inhalation Therapy. Inhalation Therapy

CLINICAL RELEVANCE OF IN VITRO PARTICLE SIZING DATA. Steve Newman, PhD Nottingham, UK November 2006

NOVOLIZER BUDESONIDE. Corticosteroids for the treatment of chronic asthma in children under the age of 12 years

AEROSOL THERAPY: THE PRACTICALITIES

BUDESONIDE AND FORMOTEROL (SYMBICORT ): Α A REVIEW

L. Borgström*, E. Bondesson*, F. Morén**, E. Trofast*, S.P. Newman +

Advanced Inhaler Technique. Learning Outcomes. Disclosure 1.1. Belgian Chocolate, French Champagne and Inhaled Medication: Too Good To Waste?

The clinical effectiveness and costeffectiveness. treatment of chronic asthma in children under the age of 12 years

Higher lung deposition with Respimat Soft Mist Inhaler than HFA-MDI in COPD patients with poor technique

ADDITIONAL TECHNOLOGIES FOR PRESSURIZED METERED DOSE INHALERS. Steve Newman Scientific Consultant Nottingham, UK

Inh l a t a i tional D i ev ces for the Ou O t u pat p ie i nts Dr Sunil Sharma Senior Resident

Correspondence: C-G. Löfdahl Dept of Respiratory Medicine and Allergology University Hospital S Lund Sweden.

Improvement of drug delivery with a breath. inhaler technique. actuated pressurised aerosol for patients with poor (1P7%)).

L. Thorsson, S. Edsbäcker, T-B. Conradson

On completion of this chapter you should be able to: discuss the stepwise approach to the pharmacological management of asthma in children

The inhaled route is preferred for the

Pulmonary deposition of inhaled drugs

Dr Christopher Worsnop

measured Improvement in am PEFR FP vs BUD gave +11l/min FP vs BDP gave nonsignificant improvement in PEFR +3l/min FP: BUD ratio 1.

Use of Respimat Soft Mist Inhaler in COPD patients

Online supplementary material

Scintigraphic comparison of budesonide deposition from two dry powder inhalers

AllergyANDClinical Immunology

Device Design Similarity

Study No.: Title: Rationale: Phase: Study Period: Study Design: Centres: Indication: Treatment: Objectives: Primary Outcome/Efficacy Variable:

Paediatric pulmonary drug delivery: considerations in asthma treatment

Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers

Asthma in Day to Day Practice

The Novolizer s : overcoming inherent problems of dry powder inhalers

Metered Dose Inhalers (MDIs) In Vitro Measures to Confirm Patient Perceptions: HFA vs. CFC

Study designs and PD/Clinical endpoints to demonstrate therapeutic equivalence: European Views

The ideal inhaler: design and characteristics to improve outcomes

The problem with critical and non-critical inhaler errors

Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability

Diagnosis, Assessment, Monitoring and Pharmacological Treatment of Asthma

THE NEW ZEALAND MEDICAL JOURNAL

I. Subject: Medication Delivery by Metered Dose Inhaler (MDI)

Bioequivalence of Inhaled Corticosteroids. -with emphasis on Pharmacokinetic Tools.

GMMMG Asthma Formulary Inhaler Options August 2017

Supplementary Medications during asthma attack. Prof. Dr Finn Rasmussen PhD. DrMedSc. Near East University Hospital North Cyprus

Treatment. Assessing the outcome of interventions Traditionally, the effects of interventions have been assessed by measuring changes in the FEV 1

Budesonide treatment of moderate and severe asthma in children: A doseresponse

Tips on managing asthma in children

Practical Problems With Aerosol Therapy in COPD. Joseph L Rau PhD RRT FAARC

Alvesco: a once-daily steroid for asthma prophylaxis

This clinical study synopsis is provided in line with Boehringer Ingelheim s Policy on Transparency and Publication of Clinical Study Data.

Using an Inhaler and Nebulizer

Nebulizer versus inhaler with spacer for beta-agonist treatment in acute bronchospastic disease

How can I benefit most from my COPD medications?

W e have shown in a previous meta-analysis of placebo

A multitude of devices

NEBULIZERS, METERED DOSE INHALERS, AND DRY POWDER INHALERS

DR REBECCA THOMAS CONSULTANT RESPIRATORY PHYSICIAN YORK DISTRICT HOSPITAL

International Journal of Medical Research & Health Sciences

Greater Manchester Asthma Management Plan 2018 Inhaler therapy options for adult patients (18 and over) with asthma

Delay Between Actuation and Shaking of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler

COPD Device Workshop. Summary. Role of inhaler device in COPD. Why use inhaler device in COPD?

Respiratory Care 2. Clinical Skills School of Medicine 2015/16

Potency ratio fluticasone propionate (Flixotide Diskus)/budesonide (Pulmicort Turbuhaler)

2008 IPAC-RS Conference Doing the Right Thing Science, Quality and Patient Focus

University of Groningen. Technology in practice Lexmond, Anne

GINA. At-A-Glance Asthma Management Reference. for adults, adolescents and children 6 11 years. Updated 2017

Equivalence Evaluation of Valved Holding Chambers (VHCs) with Albuterol Pressurized Metered Dose Inhaler (pmdi)

Clinical effect of Diskus dry-powder inhaler at low and high inspiratory flow-rates in asthmatic children

COMPARISON OF THE RESPIRABLE FRACTION FROM THREE DIFERENT DPI DEVICES

10/18/2012. Penn State University Children s Hospital JODIE STABINSKI CRNP MSN AE-C

COMMITTEE ON MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) DRAFT

How to Use Inhaled Medications for Asthma and COPD

12/18/2017. Disclosures. Asthma Management Updates: A Focus on Long-acting Muscarinic Antagonists and Intermittent Inhaled Corticosteroid Dosing

Inhaled therapy in elderly COPD patients; time for re-evaluation?

Pharmacokinetics, pharmacodynamics, and the delivery of pediatric bronchodilator therapy

Guideline topic: Pharmacological management of asthma Evidence table 4.11b: Add-on drugs for inhaled steroids: Long acting or oral B2 agonists

This clinical study synopsis is provided in line with Boehringer Ingelheim s Policy on Transparency and Publication of Clinical Study Data.

Public Assessment Report for paediatric studies submitted in accordance with Article 45 of Regulation (EC) No1901/2006, as amended.

Is the correct use of a dry powder inhaler (Turbohaler) age dependent?

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients

Dual-Controller Asthma Therapy: Rationale and Clinical Benefits

THE CHALLENGES OF COPD MANAGEMENT IN PRIMARY CARE An Expert Roundtable

Abstract Background Theophylline is widely used in the treatment of asthma, and there is evidence that theophylline has antiinflammatory

Novolizer Technical Aspects

Aerosol Delivery Devices

BEDFORDSHIRE AND LUTON JOINT PRESCRIBING COMMITTEE

Effect of particle size of bronchodilator aerosols on lung distribution and pulmonary function in patients

Achieving asthma control: the key role of inhalers

Type of intervention Treatment. Economic study type Cost-effectiveness analysis.

International co-ordinating investigator Dr Dencho Osmanliev, St Sofia, Pulmonary Dept, 19 D Nestorov Str, Sofia, 1431, Bulgaria.

Dry Powder Inhaler. Developing an Efficient. 3M Conix DPI. White Paper / Spring Proven Solutions that Enable Your Success

The optimal particle size for beta-adrenergic aerosols in mild asthmatics*

the use of inhaled corticosteroids for at least 3 months preceding the study;

Cost effectiveness of fluticasone and budesonide in patients with moderate asthma Steinmetz K O, Volmer T, Trautmann M, Kielhorn A

Small Volume Nebulizer Treatment (Hand-Held)

21/03/2011 AEROSOL DEPOSITION AND THE ASSESSMENT OF PULMONARY DRUG DELIVERY. Fundamentals of aerosols

Common Inhaled Asthma Medications Dose Comparison and Tips for Use

Transcription:

European Review for Medical and Pharmacological Sciences 2001; 5: 7-16 Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device D. DONNELL 3M Health Care, 3M House, Morley Street, Loughborough (UK) Abstract. Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike dry powder inhalers, does not rely on the patient s inspiratory effort to aerosolise the dose of medication. Due to its simple operation, the Autohaler is suitable for patients unable to operate a conventional MDI efficiently, including the elderly, children, patients with arthritis and patients with low inspiratory flow rates. The mandatory replacement of chlorofluorocarbon propellants with non-ozone-depleting propellants has given the opportunity to improve drug delivery characteristics of MDIs. Recently, a formulation of beclomethasone dipropionate in hydrofluoroalkane-134a (HFA- BDP), has been developed in a conventional MDI that delivers most of the emitted dose to the lung. Drug deposition studies show that the HFA-BDP formulation in the Autohaler device has a similar lung deposition pattern to drug delivered from the MDI, when used correctly, and dose delivery is consistent across a wide range of inspiratory flow rates. Furthermore, HFA-BDP Autohaler has similar clinical benefits to CFC- BDP Autohaler but at less than half the dose. HFA-BDP Autohaler offers a useful CFC-free delivery option for patients challenged by the conventional MDI device. Key Words: Corticosteroids, Inhaler devices, Autohaler. Introduction Recognition that asthma is a chronic inflammatory disorder of the lungs has led management guidelines to recommend the first-line use of inhaled corticosteroids 1. By reducing airway inflammation and airway hyper-reactivity, inhaled corticosteroids effectively control asthma symptoms and improve lung function 2. Inhaled therapy offers a major advantage over oral corticosteroid administration in that medication can be delivered via an inhaler device directly to the site of action with less risk of unwanted systemic effects 3. However, successful asthma management relies on patients to administer their treatment correctly on a regular basis. Lack of patient compliance or faulty inhaler technique can ultimately lead to poor control of asthma symptoms and potentially fatal acute exacerbations 4. This article reviews the issues encountered during the clinical use of each type of inhaler device, with particular regard to drug delivery and ease of use, and considers the role of a breath-actuated inhaler containing beclomethasone dipropionate (QVAR Autohaler aerosol, 3M Pharmaceuticals). Metered Dose Inhalers Since their introduction in the late 1950s, press and breathe metered dose inhalers (MDIs) have revolutionised the treatment of asthma and are the most commonly prescribed method of delivering inhaled corticosteroids. MDIs are compact, portable, pressurised systems that deliver multiple doses of drug formulated in liquid propellant. Upon actuation, a regulated measure of medication is released and the propellant aerosolises the drug component into particles suitable for inhalation, through the mouth. Drug delivery into the lung is influenced by the complex interaction between the physical characteristics of the aerosol spray, airflow, 7

D. Donnell airway morphology and pathology, as well as inhalation technique 3. Correct MDI use requires several co-ordinated manoeuvres, but with estimates of misuse ranging from 12% to 89%, it is evident that many patients find this difficult to achieve 5,6. The most common problem is synchronising the actuation of the inhaler device with slow inspiration 7. Poor coordination can result in medication being released either too early or too late in the inspiration cycle, or in the extreme, one action being performed without the other 5,8. Other types of problems encountered with MDIs include inhaling too rapidly 9, inadequate duration of breath holding 3, and the cold-freon effect, where the patient stops inhaling as soon as the cold propellant spray hits the back of the throat 10. Physical incompetence with a MDI is a particular concern for the elderly and arthritic, who often lack the hand strength and finger dexterity necessary to actuate a MDI device 11,12. The most obvious consequence of variability of drug delivery resulting from a faulty inhaler technique is sub-optimal corticosteroid therapy and an increased risk of losing control of asthma symptoms or experiencing asthma exacerbations 13. To improve drug deposition in the lung and overcome the difficulties with co-ordination, several devices have been developed, including spacer attachments for MDIs and a range of dry powder inhalers. Another solution has been the introduction of a breath-actuated MDI, and more recently, with the mandatory replacement of chlorofluorocarbon (CFCs) propellants, the development of a non-cfc breathactuated MDI containing beclomethasone dipropionate (QVAR Autohaler aerosol). Metered Dose Inhalers Plus Spacer Immediately following actuation of the conventional MDI in the mouth, the combination of high propellant velocity (> 30 m/sec) and initially large-sized aerosol particles (mass median aerodynamic diameter > 10 µm) increase the likelihood of drug deposition in the oropharynx, rather than drug reaching the site of action within the lungs 14. The attachment of a spacer device or holding chamber to the MDI compels patients to inhale at some distance from the actuator, thereby allowing time for the spray front to slow down and larger particles to deposit on the chamber walls. By this function, oropharyngeal deposition of corticosteroids is reduced, limiting local side effects such as oral candidiasis and dysphonia 15, but it is debatable as to whether or not spacers improve drug delivery to the airways 16,17. Inconsistency between studies is confounded by the observation that spacers offer no additional benefit to patients demonstrating a good inhaler technique 18. Furthermore, electrostatic charge in plastic spacers tends to retain drug particles on the inner walls of the device thereby reducing drug availability 19. Although co-ordination is less of a concern with spacer devices, other problems of misuse give rise to irregular drug delivery, such as prolonged duration between aerosol discharge and inhalation, and speed of inspiration 20,21. In addition, compliance with add-on spacer devices may be undermined by patient unwillingness to use them in public, their bulkiness making transportation an encumbrance and the need to clean and replace them regularly 22,23. Nevertheless, add-on spacer devices are particularly useful in delivering inhaled medication in young children under 5 years who would otherwise require treatment by oral or nebulised solutions. Dry Powder Inhalers Designed as breath-actuated devices to overcome the need to include chlorofluorocarbon (CFC) propellants in the formulation, dry powder inhalers (DPIs) have some inherent problems of their own. In DPIs, the corticosteroid drug is in the form of microfine particles loosely held in aggregates. The airstream created during inspiration is not only required to release the dose from the device but is essential in aerosolising the particles into a respirable size range. Consequently, both the emitted dose and the particle size distribution are subject to individual variation dependent upon the patient s inspiratory effort 24,25. In clinical practice, this can translate into less lung deposition in a patient with severe airflow obstruction and limited ability to inspire than in a patient able to generate greater inspiratory flow rates 26. 8

Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device Considering DPIs require the patient to produce sufficient inspiratory flow to ensure drug delivery into the bronchopulmonary tree, they may be regarded as having breathdependent delivery. Another potential concern inherent in DPIs, is the susceptibility of powders to become more cohesive at high humidity, thereby reducing drug output 27. However, the problem of inconveniently having to load each dose in earlier single-dose DPI devices has been overcome by the introduction of several multidose devices 28. The Breath-Actuated Autohaler Device Design of the Autohaler device Another innovation to eliminate the need to co-ordinate manual actuation and inhalation has been the development of a breathactuated MDI, the Autohaler 29. To prime the Autohaler, the patient simply lifts a lever on the top of the actuator body, which applies pressure on the canister via a spring mechanism (Figure 1). The canister is blocked from moving under this pressure by the triggering mechanism resting on a vane located behind the mouthpiece. When the patient inhales through the mouthpiece, the vane rotates, activating the triggering mechanism and releasing the drug. Importantly, however, because the Autohaler device uses a pressurised propellant system, dose delivery is actuated with an inspiratory flow of 30 L/min or more 29,30. Dose delivery does not alter with increasing inspiratory effort. A further design feature of the Autohaler is the audible click on actuation that serves to reassure the patient that the medication has been dispensed. More recently, the mandatory replacement of chlorofluorocarbon propellants has initiated reformulation of conventional and breathactuated MDIs and presented an opportunity to improve their performance, by delivering more corticosteroid drug in the lungs and less in the oropharynx. With these concepts in mind, new formulations of beclomethasone dipropionate in hydrofluoroalkane-134a, a nonozone depleting propellant, have been developed both in conventional (HFA-BDP; QVAR, 3M Pharmaceuticals) and breath-actuated Autohaler devices (HFA-BDP Autohaler; QVAR Autohaler, 3M Pharmaceuticals). Figure 1. Breath-actuated pressurised inhaler (Autohaler, 3M Pharmaceuticals). Inhalation technique Not having to synchronise actuation and inhalation, administration from the Autohaler is simplified and allows patients to focus on inhalation manoeuvres necessary to optimise drug delivery, such as slow and deep inhalation and breath holding. The breath-actuated mechanism of the Autohaler is triggered early in the inspiratory cycle at low inhalation flow rates of approximately 30 L/min 29,30. Since drug deposition of a pressurised aerosol appears to be greatest when actuation occurs in the early phase of inspiration 31, the Autohaler should enhance pulmonary delivery in patients who have difficulty synchronising actuation with inhalation. Indeed, drug deposition in the lungs from the Autohaler is equivalent to that obtained with a correctly used conventional press and breathe MDI 32. 9

D. Donnell Recently a formulation of HFA-BDP (QVAR ; 3M Pharmaceuticals) has been introduced that, compared with CFC-BDP, has a smaller particle size and a softer, warmer, slower spray, resulting in improved lung deposition (50-60% vs. < 10%) and reduced oropharyngeal deposition (30% vs. > 90%) 33. HFA-BDP has also been developed in the Autohaler device (HFA-BDP Autohaler; QVAR Autohaler ; 3M Pharmaceuticals). Lung deposition from the HFA-BDP Autohaler provides similar lung deposition as an optimally used conventional HFA-BDP press and breathe inhaler (56% vs. 58%; Table I) and dose delivery is consistent across a wide range of inspiratory flows (26-137 L/min) 33. A pharmacokinetic study in children with asthma, using activated oral charcoal to block gut absorption, has shown the early systemic bioavailability (as C max ) of HFA-BDP Autohaler 200 µg was 1.5-fold greater than CFC-BDP 400 µg plus a large volume spacer 34. This suggests that the relative lung dose in children is 3-fold higher with the HFA-BDP Autohaler 200 µg than the CFC-BDP 400 µg via a spacer. Ease of use Due to its simple operation, the Autohaler offers a useful alternative to conventional MDIs with add-on spacer devices or dry powder inhalers for patients with inadequate inhaler technique. The use of the Autohaler has been tested in a number of patient populations, including first-time and previous users of inhalers, the elderly, children, patients with arthritis and patients with low inspiratory flow rates 35-45. Operating the Autohaler device In a study involving subjects who had never previously used any type of inhaler, after following the written instructions provided with the Autohaler, 63% of individuals were able to operate the inhaler efficiently 35. When additional verbal instruction was provided, 91% of the group could use the device correctly. This was in contrast to the situation with a conventional press and breathe MDI, where only 39% of subjects could operate the inhaler competently after reading written instructions, and only 50% of subjects were proficient after receiving additional verbal instruction. Among asthma patients with a poor conventional inhaler technique, a correct Autohaler technique was demonstrated in 43% of users after reading written instruction alone and in 82% of users after receiving verbal explanation 36. In another study, patients were asked about the ease of use of the Autohaler, and 74% found the device easy to use and 76% expressed it was easier to use than other inhaler types 37. Elderly and subjects with limited manual dexterity Adequacy of Autohaler inhalation technique compared with a conventional MDI and a dry powder inhaler in elderly and/or arthritic subjects has been investigated in several studies 38-40. Two studies involving elderly populations found more patients successfully demonstrated a correct inhaler technique for the breath-actuated inhaler than for either the conventional MDI or Rotahaler, a dry powder inhaler 38,39. Similarly, a study comprising patients with limited manual dexterity found 70% of the group could use the Autohaler easily, in comparison with 54% for the Rotahaler and 46% for the Diskhaler (both dry powder inhalers), and 40% for the conventional MDI 40. Children Following instruction, children aged 3 to 13 years have been able to demonstrate an effective Autohaler technique 41-43. After demon- Table I. Deposition * as a function of HFA-BDP inhaler co-ordination. Time to actuate (sec) Lung (%) Mouth (%) Autohaler 0.2 56 29 MDI co-ordinated 0.4 58 26 MDI early 0.5 34 57 MDI late 2.5 32 24 * As a percentage of the ex-actuator dose. Data derived from reference 33. 10

Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device stration with a placebo inhaler device, 20% of a group of 3 to 6 year olds had a satisfactory Autohaler technique and after further instruction, this increased to 75%, emphasising the importance of adequate training. 41 Among a group of children with asthma aged between 4 and 13 years hospitalised with acute exacerbations, 99% of Autohaler actuations were successful compared with 74% of actuations from a dry-powder device 42. Patients with low inspiratory airflow Because the Autohaler is activated at low inspiratory flow rates it can be used in patients with relatively severe airflow obstruction. Two clinical studies have shown patients with severe airflow limitation (defined as forced expiratory volume at 1 second [FEV 1 ] of 1 L and a peak expiratory flow [PEF] of 200 L/min) were able to activate the Autohaler device 44,45. In one study 29 of 30 patients (97%) were able to actuate the Autohaler 44, while in the other study 151 of 156 patients (96.8%) actuated the device on the first or second attempt 45. Patient preference Many patients who had previously experienced co-ordination difficulties or had functional limitations with conventional MDIs expressed a preference for the Autohaler device. The results of a comparison of a conventional MDI with and without a spacer and the Turbuhaler, a dry powder inhaler, were that most patients found the Autohaler easier to use on a regular basis 30,35,38,40. Clinical efficacy: the Autohaler device versus conventional MDIs The therapeutic equivalence of the bronchodilatory action of beta-agonists such as salbutamol and pirbuterol when delivered from the Autohaler or a conventional MDI has been demonstrated in two clinical studies, involving adults or children 46,47. Similar improvements in lung function (FEV 1, forced expiratory flow rate between 25% and 75% of vital capacity [FEFR 25-75 ], and forced vital capacity [FVC]) of adult asthmatics after treatment with pirbuterol were observed when medication was inhaled from the Autohaler or an optimally operated conventional MDI 46. Also, in children aged between 6 and 14 years correctly using either device, the bronchodilatory effect of salbutamol given via the Autohaler was similar if not greater than the effect following administration from the MDI 47. The clinical response to inhaled corticosteroids from different delivery devices is confounded by many factors 2. To allow correct interpretation and comparison of the therapeutic effect of beclomethasone dipropionate delivered from the Autohaler device or a conventional MDI, a randomised, double-blind, double-dummy, crossover design was used 2,48. Also, patients included in the study were stable on inhaled corticosteroid therapy and demonstrated a proficient MDI inhalation technique. Each inhaler device was used for two weeks and patients maintained the same dose of medication throughout the study. Data revealed that treatment with beclomethasone dipropionate was clinically equivalent when delivered by the Autohaler or a conventional MDI used efficiently, as measured by lung function (FEV 1 and PEF), subjective symptom score and bronchodilator requirement. An HFA-BDP formulation in a conventional MDI (QVAR, 3M Pharmaceuticals) that significantly reduces oropharyngeal deposition and improves drug delivery to all inflammatory sites throughout the bronchopulmonary tree, has shown therapeutic equivalence to CFC-BDP but at half the nominal dose 49. The HFA-BDP formulation in the Autohaler has a similar lung deposition pattern to the HFA-BDP MDI 33, and has demonstrated similar clinical benefits to CFC- BDP Autohaler but at less than half the dose 50. In a double-blind, double dummy, randomised, parallel group study, HFA-BDP Autohaler 400 µg daily was shown to be as equally effective as CFC-BDP Autohaler 1000 µg daily in controlling asthma symptoms and lung function in patients with moderate persistent asthma (Figure 2) 50. Furthermore, there was no difference between treatment groups in airway hyperresponsiveness and serum markers of inflammation. Clinical efficacy: the Autohaler device versus DPIs Therapeutic response to drug delivery from the Autohaler has also been compared 11

D. Donnell Figure 2. Asthma symptom score, lung function and airway hyperresponsiveness in patients with moderate asthma after treatment with HFA-BDP Autohaler 400 µg daily or CFC-BDP Autohaler 1000 µg daily for 10 weeks 50. Symptom score: Assessed as the mean of the overall daytime symptom score, graded from 0 for none to 5 for incapacitating symptoms. PEF a.m.: Peak expiratory flow rate, measured in the morning as the best of three attempts. FEV 1 : Forced expiratory volume in the first second (± SD). PC 20 FEV 1 : Provocative histamine concentration causing a 20% fall in FEV 1 values (geometric mean ± SEM). with that from dry powder inhalers. A randomised, double-blind crossover study in children with asthma demonstrated similar improvements in lung function (PEF) after salbutamol was delivered from either inhaler device, but more children were able to activate the Autohaler more consistently than the Rotahaler 42. Clinical response to inhaled corticosteroid delivered from either the Autohaler or Turbuhaler devices was studied in a randomised, open-label crossover study in adult patients with stable asthma symptoms. 51 Overall therapeutic equivalence of asthma control (FEV 1, morning and evening PEF, and night-time symptoms) was demonstrated using an equivalent dose of inhaled corticosteroid from each device. However, a greater proportion of patients was confident in dose delivery from the Autohaler device as perceived by feeling and hearing dose release. Unlike the immediate symptomatic relief from inhaled bronchodilators providing reassurance of dose delivery, no such perception is apparent for inhaled corticosteroids where compliance to regular prophylactic therapy is essential for maintaining asthma control. These findings have implications for patient compliance, as confidence in inhaler use and dose delivery may affect long-term compliance to inhaled corticosteroid therapy. Interestingly, a retrospective analysis of asthma-related prescribing patterns showed the mean daily inhaled corticosteriod dose prescribed from the Autohaler was lower at 569 µg/day compared with the Diskhaler (638 µg/day), conventional MDI (665 µg/day) and Turbuhaler (990 µg/day) devices 52. This may reflect the consistency of dose delivery to the target organ for patients using the Autohaler. The 12

Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device introduction of the HFA-BDP Autohaler has offered a further opportunity to lower daily inhaled corticosteroid doses without compromising asthma control in comparison with the dose of budesonide delivered by the Turbuhaler device (BUD-TH). Asthma patients symptomatic on their current inhaled steroid dose were randomised to receive daily doses of HFA-BDH Autohaler 400 µg or BUD-TH 800 µg (mild-tomoderate asthma), or HFA-BDH Autohaler 800 µg or BUD-TH 1,600 µg (moderate-to-severe asthma) in line with Global Initiative Guidelines for Asthma (GINA) 53. In both treatment groups, HFA-BDP Autohaler at half the daily dose of BUD-TH produced equivalent improvement in control of asthma (Figure 3), but gave significantly greater improvement in patients with severe symptoms (Figure 4). While the pharmacokinetic and biochemical parameters of BUD and BDP are diverse, the efficacy results may partly be attributed to the lung deposition pattern of HFA-BDP Autohaler producing greater drug penetration into the lung periphery 33. Cost-effectiveness Ever growing pressure for cost containment in healthcare expenditure has focussed attention on the economic burden of managing chronic diseases such as asthma. Although suboptimal therapy with conventional MDIs has well-documented clinical consequences, such patients may also incur higher medical costs through more frequent physician-visits or hospitalisations, or increased use of medication for symptomatic relief 54. A recent retrospective cost analysis using data from a pharmacy and medical claims database indicated that the total cost savings associated with the use of the Autohaler device as opposed to a conventional MDI ranged from 8.7% to 11.7% 55. Cost effectiveness can also be considered in respect to drug utilisation, where compared to a conventional MDI, the Autohaler has been shown to reduce drug usage by 23% 54. Conclusion Selection of the most appropriate inhaler device for an individual patient must necessarily be based on clinical indications, patient preference and ability to use the inhaler, therapeutic response and cost. Although, the con- Figure 3. Mean change from baseline in morning PEF after 3 and 8 weeks of treatment with HFA-BDP Autohaler 800 µg/day or budesonide Turbuhaler 1600 µg/day 53. 13

D. Donnell Figure 4. Mean change from baseline in asthma symptoms (% days without symptoms) after treatment with HFA-BDP Autohaler 800 µg/day or budesonide Turbuhaler 1600 µg/day 53. ventional MDI is the most frequently prescribed inhaler for delivering inhaled corticosteroids, some patients have difficulty in synchronising the actuation of the device with inspiration, and require an alternative delivery method. The breath-actuated Autohaler is a compact, multidose inhaler device that, unlike dry powder inhalers, does not rely on the patient s inspiratory effort to aerosolise the dose of medication. Due to its simple operation, the Autohaler is suitable for patients unable to operate a conventional MDI efficiently, including the elderly, children, patients with arthritis and patients with low inspiratory flow rates. The mandatory replacement of chlorofluorocarbon propellants with non-ozone-depleting propellants has given the opportunity to improve drug delivery characteristics of MDIs. Recently, a formulation of beclomethasone dipropionate in hydrofluoroalkane-134a (HFA-BDP) has been developed in a conventional MDI that delivers most of the emitted dose to the lungs. Drug deposition studies show that the HFA-BDP formulation in the Autohaler device has a similar lung deposition pattern to drug delivered from the MDI, when used correctly. However the advantage is that dose delivery is consistent across a wide range of inspiratory flows rates. HFA-BDP Autohaler offers the patient all the therapeutic benefits associated with using an extra-fine aerosol but in addition its design provides a useful delivery option for patients challenged by other inhaler systems. References 1) GLOBAL INITIATIVE FOR ASTHMA GUIDELINES. Asthma Management and Prevention. National Institutes of Health. National Heart, Lung, and Blood Institute: 1998. 2) BARNES P, P EDERSEN S, BUSSE WW. Efficacy and safety of inhaled corticosteroids: New developments. Am J Respir Crit Care Med 1998; 157: S1-S53. 3) NEWMAN SP, PAVIA D, CLARKS SW. How should a pressurized beta-adrenergic bronchodilator be inhaled? Eur J Respir Dis 1981; 62: 3-20. 4) HARTERT TV, WINDOM HH, PEEBLES RS et al. Inadequate outpatient medical therapy for patients with asthma admitted to two urban hospitals. Am J Med 1996; 100: 386-394. 14

Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device 5) CROMPTON GK. Problems patients have using pressurised aerosol inhalers. Eur J Respir Dis 1982; 63: 101-104. 6) EPSTEIN SW, MANNING CPR, ASHLEY MJ et al. Survey of the clinical use pressurised aerosol inhalers. Can Med Ass J 1979; 120: 813-816. 7) MCFADDEN ER. Improper patient techniques with metered dose inhalers: Clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995; 96: 278-283. 8) COADY TJ, STEWART CJ, DAVIES HJ. Synchronization of bronchodilator. Practitioner 1976; 217: 273-275. 9) GOODMAN DE, ISRAEL E, JOHNSON R et al. Adequacy of patient technique during administration of bronchodilator medication by metered dose inhaler (MDI). Am Rev Respir Dis 1992; 145 (Suppl): A422. 10) NEWMAN SP, WEISZ AWB, TALAEE Net al. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax 1991; 46: 712-716. 11) ALLEN SC, PRIOR A. What determines whether an elderly patient can use a metered dose inhaler correctly? Br J Dis Chest 1986; 80: 45-49. 12) ARMITAGE JM, WILLIAMS SJ. Inhaler technique in the elderly. Ageing 1988; 17: 275-278. 13) REED CE. Aerosol glucocorticoid treatment of asthma. Am Rev Respir Dis 1990; 141: S82-S88. 14) NEWMAN SP. Aerosol physiology, deposition, and metered dose inhalers. Allergy Proc 1991; 12(1): 42-45. 15) KIM CS, ELDRIDGE MA, SACKNER MA. Oropharyngeal deposition and delivery aspects of metered-dose inhaler aerosols. Am Rev Respir Dis 1987; 135(1): 157-164. 16) PEDERSEN S. Aerosol treatment of bronchoconstriction in children with or without a tube spacer. N Engl J Med 1983; 308: 1328-1330. 17) DOLOVICH M, RUFFIN R, NEWHOUSE MT. Clinical evaluation of a simple demand inhalation MDI aerosol delivery device. Chest 1983; 84: 37-41. 18) LEE H AND EVANS HE. Evaluation of inhalation aids of metered dose inhalers in asthmatic children. Chest 1987; 91: 366-369. 19) KENYON CJ, THORSSON L, BORGSTROM L et al. The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients. Eur Respir J 1998; 11: 606-612. 20) HINDLE M, CHRYSTYN H. Relative bioavailability of salbutamol to the lung following inhalation using metered dose inhalation methods and spacer devices. Thorax 1994; 49: 549-553. 21) O CALLAGHAN C, CANT M, ROBERTSON C. Delivery of beclomethasone dipropionate from a spacer device: What dose is available for inhalation. Thorax 1994; 49: 961-964. 22) SHIM C. Inhalation aids of metered dose inhalers. Chest 1987; 91: 315-316. 23) BRITISH GUIDELINES ON ASTHMA MANAGEMENT 1995. Review and Position Statement. Thorax 1997; 52 (Suppl 1): S1-S21. 24) ROSS DL, SCHULTZ RK. Effect of inhalation flow rate on the dosing characteristics of dry powder inhaler (DPI) and metered dose inhaler (MDI) products. J Aerosol Med 1996; 9: 215-225. 25) SMITH KJ, CHAN H-K, BROWN KF. Influence of flow rate on aerosol particle size distributions from pressurized and breath-actuated inhalers. J Aerosol Med 1998; 11: 231-245. 26) NEWMAN SP, HOLLINGWORTH A, CLARK AR. Effect of different modes of inhalation on drug delivery from a dry powder inhaler. Int J Pharm 1994; 102: 127-132. 27) PLOMB A, FONTEIJN PB, ANDERSSON JAR. Effect on relative humidity on particle size distribution from Turbohaler. In: Newman SP, Moren F, Crompton GK, eds. A new concept in inhalation therapy. Medicom. The Netherlands: 100-103. 28) HANNEMANN LA. What is new in asthma: new dry powder inhalers. J Pediatr Health Care 1999; 13: 159-165. 29) BAUM EA, BRYANT AM. The development and laboratory testing of a novel breath actuated pressurized inhaler. J Aerosol Med 1988; 3: 219-220. 30) MARSHIK PL, LARSEN JS, LEACH CL et al. A novel breath actuated device (Autohaler ) consistently actuates during the early phase of inspiration. J Aerosol Med 1995; 8: 187-195. 31) NEWMAN SP, PAVIA D, CLARKE SW. Improving the bronchial deposition of pressurized aerosols. Chest 1981; 80 (Suppl): 909-911. 32) NEWMAN SP, WEISZ AWB, TALAEE N et al. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax 1991; 46: 712-716. 33) LEACH C. Effect of formulation parameters on hydrofluoroalkane-beclomethasone dipropionate drug deposition in humans. J Allergy Clin Immunol 1999; 104: S250-S252. 34) AGERTOFT L, PEDERSEN S, HARRISON L. Lung deposition and basic pharmacokinetic parameters of beclomethasone dipropionate in asthmatic children after inhalation from a HFA-pMDI (Autohaler) and a CFC-pMDI with spacer. Am J Respir Crit Care Med 1999; 159 (Pt 2): A120. 35) CROMPTON G, DUNCAN J. Clinical assessment of a new breath-actuated inhaler. The Practitioner 1989; 233: 268-269. 36) LE COCGUIC Y, ZUREIK M. Assessment of inhaler technique in everyday use of a breath-actuated metered dose inhaler (Autohaler 3M). Rev Pneumol Clin 1997; 52: 1-7. 37) BRONSKY EA, MALDEN D, PUJET JC et al. Ease-of-use study of pirbuterol acetate in the Autohaler actu- 15

D. Donnell ator in three countries: the United States, Germany and France. J Asthma 1993; 30: 439-443. 38) CHAPMAN KR, LOVE L, BRUBAKER H. A comparison of breath-actuated and conventional metered-dose inhaler techniques in elderly subjects. Chest 1993; 104: 1322-1337. 39) DIGGORY P, B AILEY R, VALLON A. Effectiveness of inhaled bronchodilator delivery systems for elderly patients. Age Aging 1991; 20: 379-382. 40) ARTHUR V, PUSHKIN S, EMERY P. Inhaler use in patients with arthritic hands. Clin Trials Meta- Analysis 1992; 28: 23-28. 41) VAN BEVER HP, VAN ASSCHE M. Teaching paediatric asthma patients to use a breath actuated inhaler. Eur Respir J 1996; 9: 229s. 42) RUGGINS NR, MILNER AD, SWARBRICK A. An assessment of a new breath actuated inhaler device in acutely wheezy children. Arch Dis Child 1993; 68: 477-480. 43) PEDERSEN S, MORTENSEN S. Use of different inhalation devices in children. Lung 1990; (Suppl): 653-657. 44) WALLACE WAH, LENNY J, COOKSEY E et al. Ability of patients with severe airflow limitation to trigger a new breath actuated inhaler. Thorax 1989; 44: 341P. 45) FERGUSSON RJ, LENNEY J, MCHARDY GJR, CROMPTON GK. The use of a new breath-actuated inhaler by patients with severe airflow obstruction. Eur Respir J 1991; 4: 172-174. 46) SCHECKER MH, WILSON AF, MUKAI DS et al. A device for overcoming discoordination with metereddose inhalers. J Allergy Clin Immunol 1993; 92: 783-789. 47) NGANTHAVEE W, VICHYANOND P, V ISITSUNTHORN Net al. A comparative study of the efficacy and administering technique of salbutamol delivered from conventional metered-dose inhaler and breath-actuated device in asthmatic children. Abstract presented at the joint meeting of the American Academy of Allergy, Asthma and Immunology (AAA&I), The American Association of Immunologists (AAI) and Clinical Immunology Society (CIS). San Francisco, CA, USA: 1997. 48) WOODMAN K, BREMNER P, B URGESS C et al. A comparative study of the efficacy of beclomethasone dipropionate delivered from a breath activated and conventional metered dose inhaler in asthmatic patients. Curr Med Res Opin 1993; 13: 61-69. 49) BUSSE W et al. Efficacy response of inhaled beclomethasone in asthma is proportional to dose and is improved by formulation with a new propellant. J Allergy Clin Immunol 1999; 105: 1215-1222. 50) MAGNUSSEN H. Equivalent asthma control after dose reduction with HFA-134a beclomethasone solution aerosol. Respir Med 2000; 94: 549-55. 51) TOWN GI, EPTON MJ, MARTIN IR et al. Comparative asthma control and certainty of dose delivery with two breath-actuated asthma inhalers. Eur J Clin Res 1994; 5: 161-169. 52) FROST GD, PENROSE A, HALL Jet al.asthma-related prescribing patterns with four different corticosteroid inhaler devices. Respir Med 1998; 92: 1352-1358. 53) WORTH H. A comparison of HFA-BDP Autohaler with budesonide Turbuhaler in asthma control of adult patients with mild to moderately severe disease. Resp Med 2000; 94 (Suppl D) S27-30. 54) KELLOWAY S, WYATT R. A cost-effectiveness analysis of breath-actuated metered-dose inhalers. Man Care Interface 1997; 99-106. 55) LANGLEY PC. The technology of metered dose inhalers and treatment costs in asthma: a retrospective study of breath actuation versus traditional press-and-breathe inhalers. Clin Therapeutics 1999; 21: 236-253. 16