RPC s Credentialing Programs for Clinical Trials

Similar documents
Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

QA for Clinical Dosimetry with Emphasis on Clinical Trials

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Catharine Clark NPL, Royal Surrey County Hospital and RTTQA

The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom

Level of Accuracy Practically Achievable in Radiation Therapy. David Followill and RPC staff August 6, 2013

SBRT Credentialing: Understanding the Process from Inquiry to Approval

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Reference Photon Dosimetry Data for the Siemens Primus Linear Accelerator: Preliminary Results for Depth Dose and Output Factor

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

EORTC Member Facility Questionnaire

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

International Practice Accreditation

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Clinical Trial Credentialing:

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

IAEA-CN THE ESTRO-EQUAL RESULTS FOR PHOTON AND ELECTRON BEAMS CHECKS IN EUROPEAN RADIOTHERAPY BEAMS*

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

BELdART-2: Moving towards safer radiotherapy. Steven Lelie 1,2, Wouter Schroeyers 1, Brigitte Reniers 1, Sonja Schreurs 1

Credentialing for Clinical Trials -IGRT. Evidence Based Radiation Oncology. Levels of Clinical Evidence. Why Credentialing?

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Implementation of an Anthropomorphic Phantom for the Evaluation of Proton Therapy Treatment Procedures

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Future upcoming technologies and what audit needs to address

Leila E. A. Nichol Royal Surrey County Hospital

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

IAEA Support to Medical Physics in Africa and Latin America: achievements & challenges

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised April 2014

Verification of Advanced Radiotherapy Techniques

3D DOSIMETRY IN END-TO-END DOSIMETRY QA

doi: /j.ijrobp

Activity report from JCOG physics group

Prostate Phantom. Guidelines for Planning and Treating the IMRT Prostate Phantom. Revised March 2014

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Transperineal Interstitial Permanent Prostate Brachytherapy (TIPPB) Quality Assurance Guidelines

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

EVALUATION OF INTENSITY MODULATED RADIATION THERAPY (IMRT) DELIVERY ERROR DUE TO IMRT TREATMENT PLAN COMPLEXITY AND IMPROPERLY MATCHED DOSIMETRY DATA

Out-of-field dosimetry in radiotherapy for input to epidemiological studies. Roger Harrison

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

IAEA activities in Medical Physics

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Brachytherapy Planning and Quality Assurance

Neutron-Gamma Mixed field Dosimetry on a Child phantom under Therapeutic Proton Irradiation using TL Dosimeters

Small field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Development and evaluation of an end-to-end test for head and neck IMRT with a novel multiple-dosimetric modality phantom

Follow this and additional works at: Part of the Medicine and Health Sciences Commons

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Response evaluation of CaSO4:Dy; LiF:Mg,Ti and LiF:Mg,Ti microdosimeters using liquid water phantom for clinical photon beams dosimetry

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

Development and Implementation of an Anthropomorphic Head & Neck Phantom for the Assessment of Proton Therapy Treatment Procedures

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Quality assurance in external radiotherapy

Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Effective and efficient radiotherapy dosimetry audit: Where to next?

SBRT of Lung & Liver lesions using Novalis IGRT System. Patrick Silgen, M.S., DABR Park Nicollet Methodist Hospital

Dosimetric Analysis Report

INTRODUCTION. Material and Methods

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

For Protocol Amendment 3 of: NRG-BR001, A Phase 1 Study of Stereotactic Body Radiotherapy (SBRT) for the Treatment of Multiple Metastases

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 4, FALL 2003

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

Presented by: Rebecca M. Howell PhD, DABR, FAAPM. Results from Voluntary Independent External Peer Review of Beam Output

Discuss the general planning concepts used in proton planning. Review the unique handling of CTV / ITV / PTV when treating with protons

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Credentialing for the Use of IGRT in Clinical Trials

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Zakithi Msimang SAAPMB/SARPA 2011

Audits for advanced treatment dosimetry

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Radiotherapy physics & Equipments

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Development of a modified head and neck quality assurance phantom for use in stereotactic radiosurgery trials

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

Proton Stereotactic Radiotherapy: Clinical Overview. Brian Winey, Ph.D. Physicist, MGH Assistant Professor, HMS

Flattening Filter Free beam

Transcription:

RPC s Credentialing Programs for Clinical Trials July 19, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff Mission The mission of the Radiological Physics Center is to assure NCI and the Cooperative Groups that institutions participating in clinical trials deliver prescribed radiation doses that are clinically comparable and consistent. Now 42 years of experience of building an infrastructure, establishing communications with institutions, developing relationships with study groups and QA offices, and adding value to the clinical trials program

RPC Programs Assurance of constancy of basic machine calibration Assurance of validity of treatment planning data Assurance of consistency of treatment records Credentialing of advanced technology procedures Assurance of Constancy of Basic Machine Calibration RPC monitors 1,768 institutions, of which ~1,600 are in the US US Machines & Facilities Increase from 1,338 in 2005 (32%) Number of radiation beams has increased more rapidly Machines Year Facilities

Improvements to Annual TLD Audits Monitor ~ 14,000 beams/yr Review of instructions Conversion from TLD to OSL Verification of Standard Output Photon and electron beams from conventional linear accelerators CyberKnife TomoTherapy Gamma Knife Protons

TLD vs OSL! LiF:Mg,Ti (TLD-100) capsules Disposable One reading Temperature and weight control. 3 dosimeters per point 6 min reading time Dosimeter cost per check $2.40 (Al 2 O 3 :C) nano dots Reusable (dose limit ~ 10Gy) Re-readable No temp/weight ctrl, light tightness 2 dosimeters per point, ~ 2 min reading time Dosimeter cost per check $1.00 Equipment OSL TLD

Distribution of TLD results Photons beams within 7% Number of beams: 3051 Avg. RPC/Inst.: 0.999 Stdev.: 1.6% Electrons beams within 7% Number of beams 4310 Avg. RPC/Inst: 0.998 Stdev.: 1.7% Institutions with One or More Unacceptable TLD Measurements Fraction of institutions 25% 20% 15% 10% 5% 0% 2000 2001 2002 2003 2004 2005 2006 2007 2008 Year

Data for other machines TLD measurements in proton beams Proton TLD Frequency Distribution 25 Protons: 109 measurements Photons: > 6,000 measurements 20 15 10 Frequency (%) 5 0 <0.94 0.94 0.95 0.96 0.97 0.98 0.99 1 1.01 1.02 1.03 1.04 1.05 1.06 >1.06 RPC/Institution

Web-Based Facility Questionnaire RPC Phantoms Pelvis (10) Spine (3) Thorax (13) H&N (31) TPC Houston: Apr. 20, 2010 SRS Head (4) Liver (2)

Number of Phantoms Mailed per Year 450 400 350 Spine SRS Head Liver Prostate Lung H&N 300 250 200 150 Phantoms Mailed 100 50 0 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Year 16

Primary PTV OAR Good Agreement Secondary PTV Measurement Plan Phantom Results Comparison between institution s plan and delivered dose. Phantom H&N Prostate Spine Lung Liver Irradiations 752 174 19 174 23 Pass 585 143 13 124 12 Pass % 78% 82% 68% 71% 52% Criteria 7%/4mm 7%/4mm 5%/3mm 5%/5mm 7%/4mm Year introduced 2001 2004 2009 2004 2005

Phantom notes Lung phantoms: Passing rate same for static vs. moving irradiations Spine phantoms: Lengthy waiting list. 4 new phantoms under construction Proton therapy facilities Presently 7 clinically-active US proton therapy centers!2 new centers expected to open this year, perhaps 5 more in next 2 years Several trials in development to allow protons NCI has provided funds for a consultant to refine visit procedures and lead visits to 5 centers during 2010

Proton Facility Approval NCI Guidelines mandate Questionnaire - sent to facilities by QARC Completed by 4 centers TLD monitoring Mailed to 7 US centers + 1 Japanese center On-site dosimetry review visits 2 visits completed (initial level of approval) 3 visits under way, to be completed this year Anthropomorphic phantoms Modifications to existing phantoms Proton Beam Monitoring 1.200 1.150 1.100 1.050 1.000 0.950 0.900 1/1/06 7/2/06 12/31/06 7/2/07 12/31/07 7/1/08 12/30/08 7/1/09 12/30/09 7/1/10

TLD: Output and Depth Dose Measurements Most measurements at mid-sobp ± 2 cm TLD: Output and Depth Dose Measurements Recent measurements at mid-sobp and ~distal 90%

Visits - Review of Institution Procedures and Records Beam measurements & QA: Profiles - lateral and depth Dose/MU reproducibility Annual QA Review of treatment planning Planning procedures Optimization Prescription CT procedures Scanning protocols CT # scaling CT # to RLSP conversion Visits: Measurements on Site CT # and conversion to RLSP Imaging system quality, dose and alignment Anatomical phantom Contouring Planning Dosimetry Beam measurements - representative fields for pituitary, spine, lung, prostate Depth dose Dose/MU Lateral profiles (deferred) Recommendations

Phantoms Existing pelvis phantom was modified Irradiated at 2 facilities Lung phantom modifications underway Materials tested Dosimetry insert constructed Evaluation of phantom underway Brain Phantom Selected Phantom Lab Alderson phantom Materials fall on CT#-RLSP curve Contains realistic bony anatomy Inserts with target and dosimetry will be constructed

Next Steps Continue to focus on approving proton centers Continue development work on phantoms Funding received from NCI through the MGH grant Supports a consultant 0.25 FTE Scheduling visits to 3 additional centers Goal is to have at least 5 proton centers approved by end of 2010 International Participation RPC has audited international institutions that are members of US study groups, as part of routine audits In 2007, RPC was approached by EORTC to consider offering TLD audits to EORTC members, at cost Following agreement among RPC, EORTC and NCI, EORTC began recommending RPC s TLD service to their members Subsequent meetings between RPC, EORTC, and other groups have been held to discuss expanding auditing procedures RPC now auditing 134 non North-American institutions Including 95 EORTC members

International Clinical Trials RTOG (and several other study groups) are expanding trials to international participation Through agreements with EORTC, RPC will make phantoms available to international participants in NCI-sponsored clinical trials EORTC staff trained to load/unload dosimeters Proposal for international workshops in development Meeting scheduled at IAEA in November to coordinate QA oversight Irradiation of RPC Phantoms Through various arrangements, 25 international institutions have already irradiated RPC phantoms Arrangements are being discussed for providing phantoms to additional institutions in Europe, the Middle East, Australasia and Latin America Through agreement with the RTOG and NCI, international non-member institutions participating in RTOG trials will meet the same QA requirements as member institutions

Supported by NCI grants CA10953 and CA81647