FUNGAL (MOLD) TESTING RESULT REPORT* Cover Page

Similar documents
Analysis Report prepared for Quest Air

MYCOLOGY REPORT. Report: / 3503 Wgaon Wheel, Wichita Falls, TX

A Healthy Home, LLC West Center Dr. Lakewood, CO

AladdinEnvironmentalLLC

DATE: September 15, TO: Sarah Johnston, Director

STC Environmental Services Inc. Environmental Scientists and Engineers

STC Environmental Services Inc. Environmental Scientists and Engineers

RE: Total Airborne Mould Spore Sampling Brookside Junior High 2239 Prospect Road, Hatchet Lake, NS

Mastertech North Jersey

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

DATE: September 12, TO: Curtis Martin, Principal. SUBJECT: Tom Hicks ES - IAQ - Air Test Results - Nurses' Office, Main Admin Office

RLB CIH, LLC. Final Report Microbial Contamination Sampling Taos Recreation Center Taos, New Mexico. March 9, 2007

DATE: February 14, TO: Amy Acosta, Principal

EXPANDED FUNGAL REPORT

March 01, Re: Mold Sampling. Dear Mr. Jon Lewis,

AIRBORNE FUNGAL STRUCTURE SAMPLE ANALYSIS Results reported as Structures per Cubic Meter of Air (structures/m 3 )

MOLD INSPECTION REPORT

DATE: May 23, TO: Tommy Ellington, Executive Director

Certificate of Mold Analysis (941) (941) SAMPLE REPORT

DATE: April 21, TO: Lisa Moore, Executive Director

Certificate of Mold Analysis

Literature Building Mold Sampling Report

Certificate of Mold Analysis

CERTIFICATE OF MOLD ANALYSIS

Certificate of Mold Analysis

Schneider Laboratories Global, Inc

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

AIRBORNE MOLD SPORE ANALYSIS

Certificate of Mold Analysis

Certificate of Mold Analysis

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 01, 2013

1251 Weatherstone Ct. Reston,VA Mold Reduction Report

Certificate of Mold Analysis

Certificate of Mold Analysis

C E R T I F I C A T E O F M O L D A N A L Y S I S

Air Sampling and Analysis for Mold in Hills Building UMass

SanAir Technologies Laboratory. Analysis Report. Hudson Valley Property Inspections, LLC

Environmental Assessment, Timothy Dwight Elementary School 1600 Redding Road, Fairfield, Connecticut

AladdinEnvironmental LLC

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH

INDOOR AIR QUALITY CLEARANCE SAMPLING

No visible mold or water intrusion/damage was found on the day of testing.

SUBJECT: Administration Building - IAQ - Initial Contact report - Room 217, Hallway outside Room 217, Room 201, Room 225, Room 212

C e r t i f i c a te o f m o ld Ana l y s i s

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

Certificate of Mold Analysis

Certificate of Analysis

Certificate of Mold Analysis

Joseph T. Burkeson. Tuesday, November 19th, Total Professional Installation 1293 N. 60th St Tampa Fl, 33619

test address: P R E PAR E D F OR : CalPro Inspection Group Phone Number: (800)

EXPANDED FUNGAL REPORT

C e r t i f i c a t e o f m o l d A n a l y s i s

Regulatory Compliance 245 Albany Avenue Thornwood, New York (914) Indoor Air Quality Screening At. Scarsdale UFSD

Cer tif ica te of mold Anal y sis

FUNGAL PARTICULATE AIR SAMPLING

IAQ & MOLD AIR SAMPLING REPORT

Schneider Laboratories Global, Inc

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

Legally Defensible Strategies for Mold Investigations

Indoor Air Quality Testing. Horry County Schools

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

CITY OF FORT PIERCE HOUSING REHABILATION PROJECT FOR 2802 AVENUE I BID NO ADDENDUM NO. 4

Certificate of Mold Analysis

Based on our review, the following primary chemical constituents were identified for sampling: Acetone Toluene Xylenes Heptane

Certificate of Mold Analysis

EFFECT OF DIFFERENT AIR FLOW RATES ON THE COLLECTION OF ATMOSPHERIC MOLD SPORES OF DIFFERENT SIZES BY A SLIT IMPACTOR

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 25, 2013

Tape Lift and Swab Sampling of Items found at Glenwood Middle School Project #J15-876

Mycotech Biological, Inc.

EDLab. Re: 0 Any Street, # 100 Laboratory Analysis Report Work Authorization #

Certificate of Analysis

Regulatory Compliance 245 Albany Avenue Thornwood, New York (914) Indoor Air Quality Screening At. Scarsdale UFSD

AGENDA REQUEST. November 7, 2016

Certificate of Analysis

EMLab P&K MOLD REPORT Mr. Quality Control 1150 Bayhill Drive Suite 100 San Bruno, CA USA (650)

Introduction: PCR Air Sampling: November 12, Carrie E Tompkins Elementary School PCR Fungi Study:

Mold Technologies Mr. Dennis Ragain 3491 Wildwood Ct. NW Salem, OR USA

Laboratory Report. Prepared Exclusively For:

Chapter 7 Aerobiological Study 7.0 INTRODUCTION 137

Specific fungal exposures, allergic sensitization, and rhinitis in infants

ECS Southeast, LLP. Report for Limited Indoor Air Quality Assessment

CERTIFICATE OF MOLD ANALYSIS PRISTINE INSPECTIONS & TESTING PHONE NUMBER: [

Certificate of Mold Analysis

EMLab P&K MOLD REPORT Mr. Quality Control 1150 Bayhill Drive Suite 100 San Bruno, CA USA (650)

This test report contains the following four sections: Chain of Custody, Data Detail, Frequently Asked Questions, and Glossary.

PRO-TEC MOLD REPORT. Mold Evaluation

SanAir Technologies Laboratory. Analysis Report. Credit Hold Accounts

Interpretation of Biological Data on Indoor Air Quality: Presence Doesn't Equate to Significance

Submitted By: test test Submittal Date: 2/2/2017 1:47:53 PM Sample Date: 2/1/2017 Lab Job No.: Page 1 1

April 28, Town of Wilton Board of Education 395 Danbury Road Wilton, CT 06897

Schneider Laboratories Global, Inc

Berman Inspection, LLC

Occupational Health & Safety, Environmental Consultants Tel. (508) Tel. (800) Fax (508)

Seasonal Periodicities of Fungal Allergens in the Atmosphere of Riyadh

THE USE OF DNA TESTING IN MOULD INVESTIGATIONS ANN DORTE PØRNEKI, M.SC.

Transcription:

FUNGAL (MOLD) TESTING RESULT REPORT* Cover Page RESULT TABLES ANALYTICAL REPORT (Spore trap report) MOLD BRIEF DESCRIPTIONS (In a separate file) Verified By: Wei Cohen, B.S. Approved By: Jian (Young) Bao, Ph. D. Certified by NY Sate Health Dept. Fungal Detail Report Cover Sheet (MB v06) Page 1 of 5

Mold Report: Microscopic Examination for Spore Trap Sample Sample Number Sample Location Sample Volume (L) Analytical Sensitivity(Counts/M ) M1 Outdoor M2 Living Rm M DinningRm Raw ct. Spores/M Raw ct. Spores/M Raw ct. Spores/M Raw ct. Spores/M M4 MstBedRm Agrocybe 8 05 114 - Alternaria - Arthrobotrys - Ascospores* 4 152 1 N - Aspergillus/Penicillium* 7 267 120 4571 O 15 571 Arthrinium N - Basidiospores* 7 267 2 76 E - Bipolaris - 114 - Chaetomium - 1 D - Cladosporium 0 114 45 1714 E 22 8 Cercospora - 1 T - Curvularia - 2 76 E - Epicoccum 1 2 76 C - Fusarium - 1 T - Ganoderma E - Myxomycetes 2 76 2 76 D 8 05 Nigrospora - Oidium - Pithomyces 7 267 1 - Stachybotrys - 1 2 76 Torula - Ulocladium 1 1 - Rust spores - Other Spores - 2 76 - Hyphae 11 419 7 267 2 76 Total 2971 7429 1867 Background Plant Pollen 2 76 2 76 Fiber Glass Insect Fragment 1-2 76 - Skin Fragments (1-5)** Total Background (1-5)** 1-1 2 2 *Aspergillus and Pneicillium spores (may include others, eg Paecilomyces ), are small and roundish with little differential traits by no-viable sampling methods. Most of basidiospores are from "mushroom", while ascospores from fungal fruit bodies. ** Skin fragment or Total background are scaled based on its density from lowest (#1) to highest (#5) on the trap slide. The scale 5 means having overloaded particulates, prohibiting counting fungal spores. Please visit: www.mbfocuslab.com. Jan (Young) Bao, Ph. D. (Lab Director) MB Focus Lab, Ver.MBST.0 Page 2 of 5

M2 Living Rm Agrocybe 0.08 05 - Aspergillus/Penicillium* 7 267 High Chaetomium 1.0 - High** Cladosporium 0 114 1.5 Medium Epicoccum 0.01 - Myxomycetes 0.02 76 - Stachybotrys 1.0 - High** Ulocladium 0.01 - Hyphae 11 0.6 419 Low 0 6 from zero ("-"). 2. The ratio of spores in cubic meter air is <1/ of outdoor control baseline, the probability of indoor source is low for this type of mold spore ("Low").. The spore number ratio is between 1/ to times of outdoor control baseline. The source is considered as indeterminate for this type of spore ("Undetermined"). 4. The spore number ratio is >, the spore type is considered as high probability of MB Focus Lab, Ver.MBST.0 Page of 5

M DinningRm Agrocybe 0.08 05 - Aspergillus/Penicillium* 0.07 267 - Chaetomium 0.0 Cladosporium 0.0 0 114 - Epicoccum 0.01 - Myxomycetes 0.02 76 - Stachybotrys 0.0 Ulocladium 0.01 - Hyphae 0.0 11 419-0 Significant Indoor-source Mold Was Not Indicated from This Sample. from zero ("-"). 2. The ratio of spores in cubic meter air is <1/ of outdoor control baseline, the probability of indoor source is low for this type of mold spore ("Low").. The spore number ratio is between 1/ to times of outdoor control baseline. The source is considered as indeterminate for this type of spore ("Undetermined"). 4. The spore number ratio is >, the spore type is considered as high probability of MB Focus Lab, Ver.MBST.0 Page 4 of 5

M4 MstBedRm Agrocybe 0.08 05 - Aspergillus/Penicillium* 7 267 2.1 Medium Chaetomium 0.0 Cladosporium 0 0.7 114 Low Epicoccum 0.01 - Myxomycetes 2 76 4.0 High Stachybotrys - 2.0 High** Ulocladium 0.01 - Hyphae 0.0 11 419-0 6 from zero ("-"). 2. The ratio of spores in cubic meter air is <1/ of outdoor control baseline, the probability of indoor source is low for this type of mold spore ("Low").. The spore number ratio is between 1/ to times of outdoor control baseline. The source is considered as indeterminate for this type of spore ("Undetermined"). 4. The spore number ratio is >, the spore type is considered as high probability of MB Focus Lab, Ver.MBST.0 Page 5 of 5