Joseph T. Burkeson. Tuesday, November 19th, Total Professional Installation 1293 N. 60th St Tampa Fl, 33619

Similar documents
Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis (941) (941) SAMPLE REPORT

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Analysis

Certificate of Analysis

CITY OF FORT PIERCE HOUSING REHABILATION PROJECT FOR 2802 AVENUE I BID NO ADDENDUM NO. 4

Certificate of Analysis

C E R T I F I C A T E O F M O L D A N A L Y S I S

test address: P R E PAR E D F OR : CalPro Inspection Group Phone Number: (800)

C e r t i f i c a te o f m o ld Ana l y s i s

C e r t i f i c a t e o f m o l d A n a l y s i s

CERTIFICATE OF MOLD ANALYSIS

Cer tif ica te of mold Anal y sis

Certificate of Mold Analysis

Berman Inspection, LLC

Analysis Report prepared for Quest Air

CERTIFICATE OF MOLD ANALYSIS PRISTINE INSPECTIONS & TESTING PHONE NUMBER: [

Certificate of Mold Analysis

A Healthy Home, LLC West Center Dr. Lakewood, CO

Certificate of Analysis

Mastertech North Jersey

PRO-TEC MOLD REPORT. Mold Evaluation

Certificate of Analysis

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

March 01, Re: Mold Sampling. Dear Mr. Jon Lewis,

Analysis Report prepared for Mold-Spec

MOLD INSPECTION REPORT

Certificate of Analysis

FUNGAL (MOLD) TESTING RESULT REPORT* Cover Page

Schneider Laboratories Global, Inc

This test report contains the following four sections: Chain of Custody, Data Detail, Frequently Asked Questions, and Glossary.

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

1251 Weatherstone Ct. Reston,VA Mold Reduction Report

Air Sampling and Analysis for Mold in Hills Building UMass

AIRBORNE FUNGAL STRUCTURE SAMPLE ANALYSIS Results reported as Structures per Cubic Meter of Air (structures/m 3 )

Legally Defensible Strategies for Mold Investigations

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

INDOOR AIR QUALITY CLEARANCE SAMPLING

This test report contains the following four sections: Chain of Custody, Data Detail, Frequently Asked Questions, and Glossary.

Tape Lift and Swab Sampling of Items found at Glenwood Middle School Project #J15-876

Indoor Air Quality Testing. Horry County Schools

Submitted By: test test Submittal Date: 2/2/2017 1:47:53 PM Sample Date: 2/1/2017 Lab Job No.: Page 1 1

Comments: Your Results

Facts about Stachybotrys chartarum and Other Molds

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH

MYCOLOGY REPORT. Report: / 3503 Wgaon Wheel, Wichita Falls, TX

AIRBORNE MOLD SPORE ANALYSIS

Schneider Laboratories Global, Inc

MSES consultants, inc.

AladdinEnvironmentalLLC

DATE: September 15, TO: Sarah Johnston, Director

MSES consultants, inc.

EXPANDED FUNGAL REPORT

DATE: May 23, TO: Tommy Ellington, Executive Director

RE: Total Airborne Mould Spore Sampling Brookside Junior High 2239 Prospect Road, Hatchet Lake, NS

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 01, 2013

Schneider Laboratories Global, Inc

MOLD SCREEN CHECK SAMPLE LAB REPORT

EDLab. Re: 0 Any Street, # 100 Laboratory Analysis Report Work Authorization #

Mold Technologies Mr. Dennis Ragain 3491 Wildwood Ct. NW Salem, OR USA

DATE: September 12, TO: Curtis Martin, Principal. SUBJECT: Tom Hicks ES - IAQ - Air Test Results - Nurses' Office, Main Admin Office

RLB CIH, LLC. Final Report Microbial Contamination Sampling Taos Recreation Center Taos, New Mexico. March 9, 2007

EMLab P&K MOLD REPORT Mr. Quality Control 1150 Bayhill Drive Suite 100 San Bruno, CA USA (650)

WHAT DOES MOLD MEAN? J&M Environmental Control Group 14 Monarch Bay Plaza, #470 Monarch Beach, CA 92629

Environmental Assessment, Timothy Dwight Elementary School 1600 Redding Road, Fairfield, Connecticut

SanAir Technologies Laboratory. Analysis Report. Hudson Valley Property Inspections, LLC

EXPANDED FUNGAL REPORT

Analysis Report prepared for. Better Air

MSES consultants, inc.

DATE: April 21, TO: Lisa Moore, Executive Director

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 25, 2013

FUNGAL PARTICULATE AIR SAMPLING

Literature Building Mold Sampling Report

DATE: February 14, TO: Amy Acosta, Principal

STC Environmental Services Inc. Environmental Scientists and Engineers

SUBJECT: Administration Building - IAQ - Initial Contact report - Room 217, Hallway outside Room 217, Room 201, Room 225, Room 212

EMLab P&K MOLD REPORT Mr. Quality Control 1150 Bayhill Drive Suite 100 San Bruno, CA USA (650)

MOLDS IN THE INDOOR ENVIRONMENT: Implications for Children s Health. Eugene C. Cole, DrPH Brigham Young University

IAQ & MOLD AIR SAMPLING REPORT

ENVIRONMENTAL ANALAYISIS ASSOCIATES, INC. BIOAEROSOL ANALYSIS METHOD GUIDE #2 January, Daniel M. Baxter

Antelope Valley College Joel I. Berman, CIH, CSP, CIAQM, CAC February 26 and 27, 2014

STC Environmental Services Inc. Environmental Scientists and Engineers

Mould Allergy. Patient Information

Mycotech Biological, Inc.

Transcription:

Tuesday, November 19th, 2013 Total Professional Installation 1293 N. 60th St Tampa Fl, 33619 Mold Sample Survey 37612 Oak Terrace, St Petersburg, FL 33703 On Friday, November 15th, 2013 I performed a Mold Sample Survey on the residence listed above. As part of the survey I searched for known Red Flags associated with mold contamination due to a plumbing leak associated with a garden tub in the master bathroom, which include. 1. Looking for signs of moisture intrusion No Current moisture intrusion detected 2. Moisture meter testing of the existing sheetrock wall - Normal Readings less than 10% No visual signs of mold were present as the tub and associated sheetrock had already been removed. As part of the survey I also conducted (3) air sample tests using standard Z-5 canisters. The areas tested included (1) exterior control and (2) interior space samples, one for the master bathroom & one in the general living area near the return duct for the HVAC System. The results listed in the attached Pro-Lab report dated November 18 th, 2013 detail an elevated mold condition within the dwelling. I suggest the following standard remediation protocol prior to construction which is consistent with EPA Guidelines. Cleanup Protocol General clean up, remove the currently stored building materials. Wet vacuum (in the case of porous materials, some mold spores/fragments will remain in the material but will not grow if the material is completely dried). Damp-wipe surfaces with plain water or with water and detergent solution; scrub as needed. High-efficiency particulate air (HEPA) vacuum after the material has been thoroughly dried. Dispose of the contents of the HEPA vacuum in well-sealed plastic bags. Professional duct cleaning by a licensed contractor. Personal Protective Equipment (PPE) - Minimum: Gloves, N-95 respirator, goggles/eye protection Containment - No containment is required since the contaminated material had already been removed prior to air testing. Clearance Testing - Performed once the remediation protocol is complete. Yours truly, Joseph T. Burkeson Joseph T. Burkeson, Florida Licensed Mold Assessor #MRSA208.

SQUARE-ONE INSPECTION SERVICE 11705 BOYETTE RD SUITE 4 RIVERVIEW, FL 33569 Certificate of Mold Analysis Prepared for: SQUARE-ONE INSPECTION SERVICE Phone Number: (813)864-7697 Fax Number: (813)671-6011 Project Name: Charles Jones Test Location: 37612 OAK TERRACE SAINT PETERSBURG, FL 33703 Chain of Custody #: 713430 Received Date: November 15, 2013 Report Date: November 18, 2013 John D. Shane Ph.D., Technical Manager Currently there are no Federal regulations for evaluating potential health effects of fungal contamination and remediation. This information is subject to change as more information regarding fungal contaminants becomes available. For more information visit http://www.epa.gov/mold or www.nyc.gov/html/doh/html/epi/mold.shtml. This document was designed to follow currently known industry guidelines for the interpretation of microbial sampling, analysis, and remediation. Since interpretation of mold analysis reports is a scientific work in progress, it may as such be changed at any time without notice. The client is solely responsible for the use or interpretation. PRO-LAB/SSPTM Inc. makes no express or implied warranties as to health of a property from only the samples sent to their laboratory for analysis. The Client is hereby notified that due to the subjective nature of fungal analysis and the mold growth process, laboratory samples can and do change over time relative to the originally sampled material. PRO-LAB/SSPTM Inc. reserves the right to properly dispose of all samples after the testing of such samples are sufficiently completed or after a 7 day period, whichever is greater. For more information please contact PRO-LAB at (954) 384-4446 or email info@prolabinc.com Page 1 of 6

0 Prepared for : SQUARE-ONE INSPECTION SERVICE Test Address : Charles Jones 37612 OAK TERRACE SAINT PETERSBURG, FL 33703 ANALYSIS METHOD Spore trap analysis Spore trap analysis Spore trap analysis INTENTIONALLY BLANK LOCATION MASTER BATH LIVING AREA OUTDOOR CONTROL COC / LINE # 713430-1 713430-2 713430-3 SAMPLE TYPE & VOLUME Z5-25L Z5-25L Z5-25L SERIAL NUMBER Z769934 Z769951 Q103364 COLLECTION DATE Nov 14, 2013 Nov 14, 2013 Nov 14, 2013 ANALYSIS DATE Nov 18, 2013 Nov 18, 2013 Nov 18, 2013 CONCLUSION ELEVATED ELEVATED CONTROL IDENTIFICATION Raw Spores Percent Raw Spores Percent Raw Spores Percent Count per m 3 of Total Count per m 3 of Total Count per m 3 of Total Chaetomium 17 6 1 1 <1 Cladosporium 1 <1 2 <1 27 1,100 44 Ganoderma 1 <1 Nigrospora 1 <1 1 2 Other Ascospores 1 <1 6 2 10 Other Basidiospores 1 <1 12 4 19 Penicillium/Aspergillus 1,748 70,000 99 1,349 54,000 99 14 560 22 Pithomyces 2 <1 Smuts, myxomycetes 2 3 Stachybotrys 1 <1 TOTAL SPORES 1,767 70,760 100 1,358 54,360 100 62 2,500 100 MINIMUM DETECTION LIMIT * 1 1 1 BACKGROUND DEBRIS Light Moderate Light Cellulose Fiber 16 6 16 6 Fiberglass 2 4 160 Plant Fragments 5 200 3 120 Pollen 1 Raw Count Spores per m 3 Percent of Total OBSERVATIONS & COMMENTS Pen/asp spores too heavy for accurate count. Counts are estimated. Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is Heavy or Too Heavy for Accurate Count. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. * Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample. NA = Not Applicable. Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted. Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional. CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s). ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium. NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth. UNUSUAL means that the presence of current or former growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated with one or more of the types of mold/fungi identified in the analyzed sample. NORMAL means that no presence of current or former growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested. Page 2 of 6

Chain of Custody # 713430 Master Bath Outdoor Control Stac hy botry s Sm uts, m y x om y c etes Penic illium /As pergillus 560 70000 Other Basidiospores 4 Other Ascospores 2 Nigros pora Clados porium 1100 Chaetom ium 6 1 10 100 1000 10000 100000 Spores per cubic meter Page 3 of 6

Chain of Custody # 713430 Living Area Outdoor Control Sm uts, m y x om y c etes Pithom y c es Penic illium /As pergillus 560 500 Other Basidiospores 4 Other Ascospores 2 Nigros pora Ganoderm a Clados porium 1100 Chaetom ium 1 10 100 1000 10000 100000 Spores per cubic meter Page 4 of 6

Identification Outdoor Habitat Indoor Habitat Possible Allergic Potential Not an opinion or interpretation Chaetomium Cladosporium Ganoderma Nigrospora Ascospores Basidiospores Penicillium/Aspergillus Pithomyces Growing on dung, dead leaves, wood. The most common spore type reported in the air worldwide. Found on dead and dying plant litter, and soil. Common everywhere growing on hardwood trees. Commonly found everywhere. Grows on decaying plant material Common everywhere. Constitutes a large part of the airspora outside. Can reach very high numbers in the air outside during the spring and summer. Can increase in numbers during and after rainfalls. Commonly found everywhere, especially in the late summer and fall. These spores are from Mushrooms. Common everywhere. Normally found in the air in small amounts in outdoor air. Grows on nearly everything. Commonly seen everywhere growing dead leaves, soil and grasses. Cellulose substrates, especially wallboard, cardboard and wood. Not normally seen growing indoors unless the building material has been wetted. Unusual / Not Normal to be growing indoors. Commonly found on wood and wallboard. Commonly grows on window sills, textiles and foods. None known. None known. Does not normally grow on building materials, but occasionally can be found growing on wallboard. Very few of this group grow inside. The notable exception is Chaetomium, Ascotricha and Peziza. Mushrooms are not normally found growing indoors, but can grow on wet lumber, especially in crawlspaces. Sometimes mushrooms can be seen growing in flower pots indoors. Wetted wallboard, wood, food, leather, etc. Able to grow on many substrates indoors. Not normally found growing indoors, sometimes on wallboard., Type III (hypersensitivity pneumonitis) Little known for most of this group of fungi. Dependent on the type (see Chaetomium and Ascotricha). Some allergenicity reported. Type I (hay fever, asthma) and Type III (hypersensitivity pneumonitis). allergies and Type III (hypersensitivity pneumonitis) None known. Comments Chaetomium is a water-indicating mold. Spores of this type of mold should not be observed in significantly higher numbers in the air above background/control. If growth and/or significantly higher than backgroud/control spore numbers are reported, corrective action should be considered to reduce the source of water, moisture levels and/or spore numbers in the living space. A very common and important allergen source both outdoors and indoors. Very distinctive spore that is easy to identify. Among the group of Mushrooms (Basidiomycetes) are dry rot fungi Serpula and Poria that are particularly destructive to buildings. This is a combination group of Penicillium and Aspergillus and is used when only the spores are seen. The spores are so similar that they cannot be reliably separated into their respective genera.

Identification Outdoor Habitat Indoor Habitat Possible Allergic Potential Not an opinion or interpretation Smuts don`t normally grow indoors, but can occasionally be Smuts, myxomycetes Commonly found everywhere, found on things brought from espcially on logs, grasses and outside and stored in the house. weeds. Myxomycetes can occasionally grow indoors, but need lots of water to be established. Stachybotrys Grows in the soil and decaying plant material. Wallboards and other paper products that are wetted. Needs high water content in the substrate to grow. Not normally seen growing indoors unless the building material has been wetted. Unusual / Not Normal to be growing indoors. Comments Smuts and myxomycetes are a combined group of organisms because their spores look so similar and cannot be reliably distinquished from each other. Wet spored mold that generally must be dried out and disturbed before spores can be found in the air. Spores of this type of mold should not be observed in significant numbers in the air above background/control. If growth and/or significantly higher than background/control spore numbers are reported, corrective action should be considered to eliminate the water source, reduce moisture levels and/or spore numbers in the living space.